77.6 m Tokyo International Airport Tower at Haneda in 1993, as shown in Figure 15. The<br />

1400 shallow circular cylindrical vessels <strong>with</strong> 60 cm diameter and 12.5 cm height had injection<br />

taps and handles to serve as projections and 4 conical dents on the upside and base. These projections<br />

and dents provide additional stiffness for stacking the polyethylene vessels. During an actual<br />

storm, data revealed that the 22.7 kg TSD application raised the damping ratio to 1%, peaking at<br />

7.6% as the rms acceleration grew (Tamura et al. 1996).<br />

Figure 15: Tokyo International Airport<br />

Tower (TIAT) at Haneda and views <strong>of</strong><br />

TLD units . installed (taken from Tamura<br />

et al. 1996).<br />

6.3 m<br />

Air traffic control room<br />

<strong>Mitigation</strong> <strong>of</strong> <strong>Motions</strong> <strong>of</strong> <strong>Tall</strong> <strong>Buildings</strong> <strong>with</strong> <strong>Specific</strong> <strong>Examples</strong> <strong>of</strong> Recent Applications 18<br />

TLD<br />

0.6 m<br />

77.6 m<br />

0.6 m<br />

22 m<br />

0.125 m