Clearances<br />
The horizontal distance between adjacent single axis swing seats at rest, when occupied by the maximum user, shall<br />
be no less than 600 mm when measured 1.5m above the protective surfacing.<br />
The horizontal distance between the supporting structure and the adjacent single axis swing seat, when occupied by<br />
the maximum user, shall not be less than 750 mm when measured at 1.5 m above the protective surfacing.<br />
The horizontal distance between the hangers supporting a single axis swing seat shall be greater than the width of<br />
the seat when occupied by the maximum user, and shall not be less than 500 mm.<br />
The vertical distance between the underside of the occupied seat and the protective surfacing shall not be less than<br />
300 mm.<br />
15.6.2.5.1<br />
The horizontal distance between adjacent to-fro swing seats at rest, when occupied by the maximum user, shall be<br />
no less than 600 mm when measured 1.5 m above the protective surfacing.<br />
15.6.2.5.2<br />
The horizontal distance between the supporting structure and the adjacent to-fro swing seat, when occupied by the<br />
maximum user, shall be not less than 750 mm when measured at 1.5 m above the protective surfacing.<br />
15.6.2.5.3<br />
The horizontal distance between the hangers supporting a to-fro swing seat shall be greater than the width of the seat<br />
when occupied by the maximum user, and shall not be less than 500 mm.<br />
15.6.2.5.4<br />
Figure 1<br />
The vertical distance between the underside of the occupied seat and the protective surfacing shall not be less than<br />
300 mm.<br />
22