OutLIne SPeCIfICAtIOnS DC1<br />

WARehOuSe<br />

• 10.8 m or 12.2 m clear height,<br />

steel frame<br />

• General column bay spacing of<br />

approximately 12 x 22 m<br />

• 1 no. electrical loading dock per<br />

1,000 m² warehouse area<br />

• 1 no. level access doors per unit<br />

(4.0 m x 4.5 m)<br />

• floor loading capacity of 5,000 kg/m2 and a maximum rack leg load of<br />

7,000 kg/m2 • Average floor flatness of class 4<br />

(neB 2747)<br />

• heating with individual gas units<br />

to possible 13 °C with outside<br />

temperature -10 °C<br />

• energy efficient t5 lighting:<br />

average lighting level 200 Lux in<br />

warehouse and average lighting<br />

level in order-picking area of<br />

250 Lux measured +1.0m<br />

-<br />

ffL<br />

• fire alarm and evacuation alarm,<br />

inclusive a fire alarm panel, fire<br />

hoses, emergency lighting as per<br />

regulations<br />

• Certified eSfR K14 roof-net sprinkler<br />

system in warehouse<br />

• Insulation value of 2.5 for the roof<br />

and façade (Rc = 2.5 m² K/W)<br />

Distribution Center 1<br />

• Battery charge area with battery<br />

charge electrical connection points<br />

(1 per 1,000 m² warehouse area)<br />

• Optional Rail Connection<br />

• Optional mezzanine along front<br />

elevation, approx. 12 m deep, level<br />

+5.25 m. floor loading capacity of<br />

500 kg/m²<br />

OffICe<br />

• Main office pod in 2 levels, mechanical<br />

ventilation<br />

• Central gas heating to 21 °C with<br />

outside temperature of -10 °C<br />

• top cooling in offices<br />

• Minimum lighting to 400 Lux on 1 m<br />

with fully-recessed fluorescent fixtures<br />

with low brightness louvers<br />

• Ceramic floor tile in reception area<br />

• Pantry with sink, fridge, kitchen<br />

block (one per floor)<br />

• Male and female toilet facilities on<br />

each floor<br />

• Power at perimeter and in wall<br />

ducts, with vacant provision for<br />

phone and data cabling<br />

• false ceiling<br />

No warranties or representations, expressed or implied, are made as to the accuracy or completeness of the information<br />

contained herein. All sizes are approximate. <strong>Prologis</strong> makes no commitment to update the information contained herein, and<br />

may make changes to these materials at any time without notice.<br />

• fire alarm and evacuation alarm,<br />

fire hoses, emergency lighting as<br />

per regulations<br />

SIte exteRIOR<br />

• 2 m high security fence with 2<br />

manually operating sliding gates<br />

(width 10 m)<br />

• Loading pit is suitable for incoming<br />

and outgoing standard european<br />

trucks according to eVO advice,<br />

semi-hardened fire road at rear of<br />

building<br />

• Landscaping: as required. non<br />

paved areas sown in with grass.<br />

Shrubs around office block<br />

• Paving with heavy-duty 100 mm<br />

concrete slabs in truck zone,<br />

80 mm concrete slabs in passenger<br />

vehicle areas<br />

• Ample car parking and truck<br />

parking on site (as per drawing)<br />

SuStAInABILItY<br />

• Air-tightness of building<br />

• Optional solar or photovoltaic<br />

panels on roof and/or wind energy<br />

• BReeAM certification<br />