Ball Float Steam Traps for Pressures up to 32 bar - Filter
Ball Float Steam Traps for Pressures up to 32 bar - Filter
Ball Float Steam Traps for Pressures up to 32 bar - Filter
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FT44 DIN specification<br />
Steel flanged<br />
DN80 and DN100<br />
DN15 – DN50<br />
Sizes and pipe connections<br />
DN15, 20, 25, 40, 50, 80 and 100 flanged BS 4504 PN40,<br />
BS 1560 class 150 or 300<br />
DN15 - 50 horizontal / vertical connection<br />
DN80 - 100 horizontal<br />
Materials<br />
Body/cover Steel DIN 17245 GS-C25N<br />
Bolting<br />
DN15 - 50<br />
DN80 - 100<br />
Steel<br />
Steel<br />
DIN 17240 21 Cr MoV57 and<br />
24 Cr Mo5<br />
BS 4439 B7 and<br />
BS 3692 2H<br />
Gasket Rein<strong>for</strong>ced exfoliated graphite<br />
Internals Stainless steel<br />
Body and cover from TÜV approved foundry.<br />
Limiting conditions (ISO 6552)<br />
Body design conditions PN40<br />
PMA - Maximum allowable pressure 40 <strong>bar</strong> g<br />
TMA - Maximum allowable temperature 400°C<br />
Cold hydraulic test pressure 60 <strong>bar</strong> g<br />
Maximum differential pressure (D PMX)<br />
FT44-4.5 (4.5 <strong>bar</strong>) FT44-10 (10 <strong>bar</strong>) FT44-14 (14 <strong>bar</strong>)<br />
FT44-21 (21 <strong>bar</strong>) FT44-<strong>32</strong> (<strong>32</strong> <strong>bar</strong>)<br />
B<br />
C<br />
50 000<br />
40 000<br />
30 000<br />
20 000<br />
Capacities<br />
10<br />
0.1 0.2 0.3 0.5 1 2 3 4 5 10 20 <strong>32</strong><br />
Differential pressure <strong>bar</strong> (x 100 = kPa)<br />
Note: Capacity shown above is based on discharge at saturation<br />
temperature. When discharge sub-cooled condensate the air vent<br />
provides extra capacity.<br />
Operating range<br />
0<br />
400<br />
150 300 450 580<br />
752<br />
300<br />
A, B<br />
572<br />
200<br />
100<br />
0<br />
0 10<br />
<strong>Steam</strong><br />
saturation<br />
B<br />
curve<br />
20 30 <strong>32</strong><br />
Pressure <strong>bar</strong> g<br />
392<br />
212<br />
A<br />
<strong>32</strong><br />
40<br />
The product must not be used in red area<br />
A - A Flanged ANSI 300, PN40<br />
B - B Flanged ANSI 150<br />
Size A A A B C D E F Weight (kg)<br />
CI.300 CI.150 PN40<br />
DN15 209 203 150 80 80 215 120 155 10.8<br />
DN20 209 205 150 80 80 225 120 165 10.8<br />
DN25 212 208 160 115 85 282 170 215 15.0<br />
DN40 <strong>32</strong>7 <strong>32</strong>1 230 130 115 337 200 200 33.0<br />
DN50 <strong>32</strong>0 313 230 141 123 347 200 225 43.0<br />
DN80 373 373 373 140 123 340 200 310 95.0<br />
DN100 366 350 350 140 123 390 200 310 97.0<br />
Temperature °C<br />
10 000<br />
5 000<br />
4 000<br />
3 000<br />
2 000<br />
Differential pressure psi<br />
2 3 4 5 10 20 30 50 100 200 400<br />
100 000<br />
Pressure psi g<br />
A<br />
E<br />
D<br />
F<br />
A<br />
E<br />
F<br />
D<br />
F<br />
D<br />
E<br />
FT44 (DN15 - DN50) FT44 (DN80 and DN100)<br />
Dimensions (approximate in millimetres)<br />
Condensate kg / h<br />
1 000<br />
500<br />
400<br />
300<br />
200<br />
100<br />
50<br />
40<br />
30<br />
20<br />
DN40 FT44-21-<strong>32</strong><br />
DN80 & 100 FT44-4.5<br />
DN80 & 100 FT44-10<br />
DN50 FT44-4.5<br />
DN40 FT44-4.5<br />
DN25 FT44-4.5<br />
DN25 FT44-14<br />
DN15 & 20 FT44-4.5<br />
DN15 & 20 FT44-10<br />
DN15 & 20 FT44-14<br />
DN15 & 20 FT44-21<br />
DN15 & 20 FT44-<strong>32</strong><br />
B<br />
C<br />
DN80<br />
DN50 FT44-10<br />
DN40 FT44-10<br />
DN25 FT44-21<br />
& DN100 FT44-21<br />
DN25 FT44-10<br />
FT44<br />
-21-<strong>32</strong><br />
DN25<br />
FT44-<strong>32</strong><br />
60 000<br />
50 000<br />
40 000<br />
30 000<br />
20 000<br />
10 000<br />
5 000<br />
4 000<br />
3 000<br />
2 000<br />
1 000<br />
500<br />
400<br />
300<br />
200<br />
100<br />
50<br />
40<br />
30<br />
Condensate lb / h<br />
Temperature °F<br />
9