15.10.2013 Views

Electrochemistry from a single source - Filter

Electrochemistry from a single source - Filter

Electrochemistry from a single source - Filter

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Electrochemistry</strong> <strong>from</strong> a <strong>single</strong> <strong>source</strong><br />

The new electrochemistry range combines the<br />

know-how of the POLYMETRON, HACH and<br />

CONTRONIC brands with the high quality standards<br />

and services of LANGE. We can provide you<br />

with the made-to-measure solution for your application<br />

(pollution, temperature, pressure, ex zone,<br />

CIP, immersion/insertion fitting). With integrated<br />

self-monitoring and temperature measurement, of<br />

course.<br />

One of the results of the continuous improvement<br />

of our proven measurement technology is the LDO<br />

optical oxygen sensor.<br />

Information<br />

>><br />

ELECTROCHEMISTRY ONLINE<br />

Overview<br />

We supply<br />

Oxygen: With an optical sensor -<br />

no more calibrations, changes of<br />

membranes or electrolyte, no toxic<br />

risk <strong>from</strong> H2S pH/redox: Combination, self-cleaning<br />

and solid state electrodes<br />

Conductivity: Conductive or inductive<br />

electrodes for strongly polluted media<br />

All parameters are also available for the<br />

laboratory.


HACH ELECTROCHEMISTRY SP510<br />

ONLINE<br />

Wasserhärte-Monitor<br />

pH/redox<br />

Electrodes and transmitters for pH/redox potential<br />

Application MONEC<br />

9135<br />

MONEC<br />

8930<br />

ANALON<br />

pH10<br />

MONEC<br />

8965 ex<br />

Potable water and (industrial) wastewater 8350/8351 8350/8351 8350 8350/8351<br />

Strongly adhering media (e.g. lime milk) 8346 8346 8346<br />

Ultrapure water, low-ion potable water 8362 8362 8362<br />

Transmitter<br />

2-wire version (explosion-proof) <br />

2 channels <br />

Modbus, Profibus <br />

Second analogue output (0/4-20 mA) <br />

Temperature output <br />

Relay contacts (max. 4) <br />

Measuring range 0...14 pH / -1,500...1,500 mV <br />

Power supply (V AC) 24/95-265 24/110/220/240 24/115/230 15.5...32<br />

Dimension of field enclosure, IP 65 (HxWxD) (mm) 144x144x150 144x144x150 237x220x108 165x165x93<br />

Control panel mounting (HxWxD) (mm) 144x144x150 144x144x150 96x96x145<br />

Sensor 8350 8351 8346 8362<br />

Combined pH electrode 0...14 pH<br />

Redox electrode -1,500...1,500 mV<br />

Antimony ring electrode 5.5...14 pH<br />

Platinum ring electrode -1,500...1,500 mV<br />

Solid state electrode, ultrapure water 2...12 pH<br />

Immersion sensor <br />

Insertion sensor <br />

Max. pressure/temperature 10 bar/110 °C 10 bar/110 °C atm/80 °C atm/80 °C<br />

standard<br />

optional


NO.0251<br />

xx<br />

Monat 2002<br />

>><br />

ELECTROCHEMISTRY ONLINE<br />

Conductivity<br />

Electrodes and transmitters for conductivity<br />

Application MONEC<br />

9125<br />

MONEC<br />

8920<br />

MONEC<br />

8921<br />

ANALON<br />

Cond10<br />

MONEC<br />

8964 ex<br />

Potable water, (industrial) wastewater, conductive 8311/12/8394 8311/12/8394 RET5, M5 8311/12<br />

Potable water, (industrial) wastewater, inductive 8398 8398<br />

Ultrapure water 8310/8394 8310/8394 8310/94<br />

Transmitter<br />

2-wire version (explosion-proof) <br />

Resistance measurement <br />

Concentration measurement <br />

2 channels <br />

Modbus, Profibus <br />

Second analogue output (0/4-20 mA) <br />

Temperature output <br />

Relay contacts (max. 4) <br />

Measuring range 0.01 µS/cm...2,000 mS/cm <br />

Power supply (V AC) 24/95-265 24/110/ 24/110/ 24/115/230 15.5...32 V<br />

220/240 220/240<br />

Dimension of field enclosure, IP 65 (HxWxD) (mm) 144x144x150 144x144x150 144x144x150 237x220x118 165x165x96<br />

Control panel mounting (HxWxD) (mm) 144x144x150 144x144x150 144x144x150 96x96x145<br />

Sensor 8398 8310/1/2 RET5-EL M5-EL 8394<br />

2-electrode system, 0.01 µS/cm...200 µS/cm K=0.01 K=0.01<br />

2-electrode system, 0.1 µS/cm...2 mS/cm K=0.1<br />

2-electrode system, 1 µS/cm...20 mS/cm K=1<br />

5-electrode system, 0.01 mS/cm...500 mS/cm K=1 K=1<br />

Inductive, 0.1 mS/cm...2,000 mS/cm K=2.35<br />

Immersion sensor <br />

Insertion sensor <br />

Max. pressure/temperature 18 bar/140 °C 10 bar/125 °C 4 bar/100 °C 3,5 bar/60 °C 25 bar/150 °C<br />

standard<br />

optional


DOC033.52.00261.Jul03<br />

>><br />

Electrodes and transmitters for O 2<br />

Application OXISTAT<br />

9181<br />

ELECTROCHEMISTRY ONLINE<br />

Oxygen<br />

DR. BRUNO LANGE<br />

GMBH & CO. KG<br />

Willstätterstraße 11<br />

D-40549 Düsseldorf<br />

Tel. +49 (0) 211 5288-0<br />

Fax +49 (0) 211 5288-210<br />

kundenservice@drlange.de<br />

www.drlange.de<br />

ANALON<br />

DO 10<br />

LANGE UK LTD<br />

Lennox Road<br />

Basingstoke<br />

Hampshire, RG22 4AP<br />

Tel. +44 (0)1256 333 403<br />

Fax +44 (0)1256 330 724<br />

info@drlange.co.uk<br />

www.drlange.com<br />

SC100 OXISTAT<br />

9182<br />

Potable water and (industrial) wastewater 9181 D05 LDO<br />

Ultrapure water, low-ion potable water 9182<br />

Transmitter<br />

2 channels <br />

Modbus, Profibus <br />

Second analogue output (0/4-20 mA) <br />

Relay contacts (max. 4) <br />

Measuring range of dissolved O2 (mg/l) 0.1-20 0.1-20 0.05-20 0.005-2<br />

Power supply (V AC) 24/95-265 115/230 100/240 24/95-265<br />

Dimension of field enclosure, IP 65 (HxWxD) (mm) 144x144x150 237x220x108 144x144x150 144x144x150<br />

Control panel mounting (HxWxD) (mm) 144x144x150 96x96x145 144x144x150 144x144x150<br />

Sensor 9181 DO 5 LDO 9182<br />

Optical sensor <br />

1-year warranty on sensor cap <br />

No toxic risk <strong>from</strong> H2S <br />

Refill electrolyte not necessary not necessary <br />

Self-cleaning <br />

Calibration in factory, service life <br />

No flow needed around the electrode <br />

Immersion sensor <br />

Insertion sensor / free outflow <br />

standard<br />

optional


DOC033.52.00261.Jul03<br />

Keeping you fully informed<br />

For more information about LANGE electrochemistry or any of our products<br />

please complete this faxback form and fax it to us (please tick).<br />

My parameter(s): pH/Temperature Conductivity<br />

Oxygen Redox potential<br />

My application(s): Wastewater Potable water<br />

Industry Ultrapure water<br />

Insertion fitting Immersion fitting<br />

Model: Online instrument Laboratory<br />

instrument<br />

FAX RESPONSE<br />

>><br />

Power supply: _______________________________________<br />

Measuring range(s): _______________________________________<br />

Pressure / Temperature: _______________________________________<br />

Other characteristics: _______________________________________<br />

_______________________________________<br />

Name _______________________________________<br />

Company _______________________________________<br />

Dept. _______________________________________<br />

Street _______________________________________<br />

Postcode/Town _______________________________________<br />

Phone _______________________________________<br />

Fax _______________________________________<br />

Mail _______________________________________<br />

ELECTROCHEMISTRY ONLINE<br />

Overview<br />

DR. BRUNO LANGE<br />

GMBH & CO. KG<br />

Willstätterstraße 11<br />

D-40549 Düsseldorf<br />

Tel. +49 (0) 211 5288-0<br />

Fax +49 (0) 211 5288-210<br />

kundenservice@drlange.de<br />

www.drlange.de<br />

FAX<br />

International<br />

+49 (0) 211/ 52 88-175<br />

UK 012 56 / 33 07 24<br />

I am also interested in the determination of:<br />

LANGE UK LTD<br />

Lennox Road<br />

Basingstoke<br />

Hampshire, RG22 4AP<br />

Tel. +44 (0)1256 333 403<br />

Fax +44 (0)1256 330 724<br />

info@drlange.co.uk<br />

www.drlange.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!