23.10.2013 Views

MOULDED POLYESTER ENCLOSURES MINIPOL SYSTEM

MOULDED POLYESTER ENCLOSURES MINIPOL SYSTEM

MOULDED POLYESTER ENCLOSURES MINIPOL SYSTEM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MOULDED</strong> <strong>POLYESTER</strong> <strong>ENCLOSURES</strong> <strong>MINIPOL</strong> <strong>SYSTEM</strong>


SHOCKPROOF<br />

Can take hits up to<br />

20 Joules,<br />

IK 10 according to<br />

UNE-EN 50102<br />

IEC 62262 standards<br />

SELF EXTINGUISHABLE<br />

Does not feed the flames<br />

Hot wire test: 960 °C according<br />

to UNE-EN 60695-2-1/0<br />

IEC 60695-2-10<br />

standards<br />

THERMIC CLASS<br />

-50…+150 °C<br />

E150°, according to UNE 21305<br />

EN-HD 566S1 and IEC 60085<br />

standards<br />

HALOGENFREE<br />

Does not issue toxic<br />

gases<br />

NON-HYGROSCOPIC<br />

Does not absorb damp or water<br />

DISTRIBUTION BOXES<br />

THE <strong>MINIPOL</strong> RANGE<br />

The enclosures are in comformity with requirements of standard EN 50298.<br />

CERTIFICATES<br />

UL, CSA, KEMA<br />

COLOUR<br />

RAL 7035<br />

LGAI - Laboratori General d’ Assaig i Investigacions<br />

DEGREE OF PROTECTION<br />

IP 66 according to<br />

UNE 20324, EN 60529<br />

IEC 62262 standards<br />

DOUBLE INSULATION<br />

Protection from electric shock<br />

according to UNE 60439-1<br />

and IEC 60439-1 standards<br />

U = 690 V<br />

i<br />

CORROSION-RESISTANT<br />

Resistant to climatic-changes<br />

and ultra-violet rays<br />

Does not requir<br />

any finishing<br />

EASY and FAST FITTING<br />

No special tool is needed


POF<br />

TF-MIP<br />

FP<br />

MOUNTING<br />

FLEXIBILITY<br />

There are possible to fit horizontally<br />

or vertically, obtaining a lot of combinations.<br />

- set of adjustable moulded brakets<br />

(4 pcs)<br />

- wall fixing set directly to the wall<br />

with 4 pcs wall-plug<br />

- pole mounting with bridle or band<br />

CLOSING PLATES (U)<br />

COUPLING PIECES (UM)<br />

MODULAR MOUNTING PANEL<br />

and INNER DOOR (CH)<br />

Mounting panel and inner door<br />

maintain IP 20 degree of protection<br />

when the external door is open.<br />

STRUCTURE OF <strong>MINIPOL</strong> <strong>ENCLOSURES</strong><br />

EASY TO MACHINE<br />

Vertical patterns in the interior of the doors,<br />

which enables the correct fitting of devices.<br />

INNER DOOR (PI)<br />

There is possible to fit devices<br />

on the lockable inner door.<br />

PROTECTIVE EDGE at the<br />

BOTTOM and on TOP<br />

Single-block body, with even walls<br />

optimisin the space and resistance.<br />

SPECIALIZATION<br />

It is possible to pre-machining by<br />

request and to ask for personalized<br />

colours. The colouring agent added<br />

to the material before pressure.<br />

EASY FITTING<br />

Quick fixture guides in the back.<br />

Permits fitting without drilling.<br />

VARIOUS CLOSING <strong>SYSTEM</strong>S<br />

All of the basic closing and locking<br />

system provide that the locks can be<br />

personalized to customer demand.


MIP-MS<br />

Flat door<br />

M=<br />

S=<br />

/PT<br />

Height<br />

(300, 400, 500, 600, 800)/3 = 300 mm, 4 = 400 mm etc.)<br />

Width<br />

(250, 300, 40, 500, 600)/25 = 250 mm, 3 = 300 mm etc.)<br />

Depth does not marked<br />

at 300 mm height is 140 mm depth<br />

at 400 mm and 500 mm height is 200 mm depth<br />

at 600 mm heigth is 230 mm depth<br />

at 800 mm height is 300 mm depth<br />

Transparent door<br />

For example: MIP-43/PT = an enclosure, 400 mm height, 300 mm width,<br />

200 mm depth, with a tansparent door<br />

Flat door (without marking)<br />

/3P Three point closing device,<br />

with 1 pc double bit DIN 3.0 mm,<br />

with swing lock, with double winged handle<br />

/ EKDB Three point closing device,<br />

with swing door, with 1 pc double bit<br />

DIN 3.0 mm, with swing lock, with sunke swinging handle<br />

Double winged handle with simple lock bolt<br />

/CH... Modular mounting plate with different number of devices<br />

BASIC TYPES<br />

MIP-<br />

325<br />

43<br />

44<br />

54<br />

64<br />

65<br />

86<br />

Transparent door<br />

325/PT<br />

43/PT<br />

44/PT<br />

54/PT<br />

64/PT<br />

65/PT<br />

86/PT<br />

EXPLANATION OF THE TYPE-SYMBOLS<br />

MIP = <strong>MINIPOL</strong> Product range<br />

43/3P<br />

44/3P<br />

54/3P<br />

64/3P<br />

65/3P<br />

86/3P<br />

43/PT/3P<br />

44/PT/3P<br />

54/PT/3P<br />

64/PT/3P<br />

65/PT/3P<br />

86/PT/3P<br />

Supplied with all the accessories enabling it to be fixed to a wall.<br />

43/EKDB<br />

44/EKDB<br />

54/EKDB<br />

64/EKDB<br />

65/EKDB<br />

86/EKDB<br />

43/PT/EKDB<br />

44/PT/EKDB<br />

54/PT/EKDB<br />

64/PT/EKDB<br />

65/PT/EKDB<br />

86/PT/EKDB


DIMENSIONS OF THE <strong>ENCLOSURES</strong> [mm]<br />

DIMENSIONS OF TRANSPARENT DOORS [mm]<br />

COUPLING PIECES<br />

A B C D E F G<br />

MIP-325 300 250 140 276 212 120 110<br />

MIP-43 400 300 200 370 262 180 170<br />

MIP-44 400 400 200 370 362 180 170<br />

MIP-54 500 400 200 470 362 180 170<br />

MIP-64 600 400 230 570 362 210 200<br />

MIP-65 600 500 230 570 462 210 200<br />

MIP-86 800 600 300 770 562 280 270<br />

A B E F<br />

MIP-325 220 115 35 75<br />

MIP-43 281 141 52 80<br />

MIP-44 281 221 52 90<br />

MIP-54 381 221 52 90<br />

MIP-64 481 221 52 90<br />

MIP-65 481 321 52 90<br />

MIP-86 681 421 52 90<br />

For vertical fitting<br />

UM-420V - for 250 mm width<br />

UM-430V - for 300 mm width<br />

UM-440V - for 400 mm and more width<br />

For horizontal fitting<br />

UM-430H - for 300 mm height<br />

UM-440H - for 400 mm and more height<br />

CLOSING PLATES<br />

U-402 - for 250 mm<br />

U-403 - for 300 mm<br />

U-404 - for 400 mm and 500 mm


ASSEMBLING POSSIBILITIES<br />

UM-420V UM-430V UM-440V UM-440V UM-440V Vertical coupling pieces<br />

DIMENSIONS OF INNER DOORS [mm]<br />

Type: PI<br />

Horizontal coupling pieces<br />

UM-430H (2 pcs)<br />

UM-440H (2 pcs)<br />

UM-440H (2 pcs)<br />

UM-440H (2 pcs)<br />

UM-440H (2 pcs)<br />

A B<br />

MIP-43 366 258<br />

MIP-44 366 358<br />

MIP-54 466 358<br />

MIP-64 566 358<br />

MIP-65 566 658<br />

MIP-86 766 658


PBP<br />

PBM<br />

PBM-/B<br />

PBR<br />

Adjustable base plate kit (4 pcs)<br />

BASE PLATES<br />

Polyester, PBP - (type of box)<br />

- thickness: 4 mm<br />

Metal, coloured, PBM - (type of box)<br />

- thickness: 2 mm<br />

Metal, with surface treatment, PBM- / B (type of box)<br />

- thickness: 2 mm<br />

- colour: RAL 2000<br />

Perforated mounting plate, PBR- (type of box)<br />

(TELEQUICK)<br />

- thickness: 2 mm<br />

Fitting clips for PBR<br />

Clip M4, Clip M5, Clip M6.<br />

A B C D<br />

PBP/325 ( for MIP-325) 268 213 248 175<br />

PBP/43 ( for MIP-43) 358 260 338 222<br />

PBP/44 ( for MIP-44) 358 360 338 322<br />

PBP/54 ( for MIP-54) 458 360 438 322<br />

PBP/64 ( for MIP-64) 558 360 538 322<br />

PBP/65 ( for MIP-65) 558 460 538 422<br />

PBP/86 ( for MIP-86) 754 556 734 518<br />

For enclosures: MIP-325 MIP-43 MIP-44 MIP-54 MIP-64 MIP-65 MIP-86<br />

Type of kit: - PDP-200 PDP-200 PDP-200 PDP-230 PDP-230 PDP-300<br />

Adjustable and hinged base plate kit<br />

DIMENSIONS [mm]<br />

For enclosures:<br />

MIP-325 MIP-43 MIP-4 MIP-54 MIP-64 MIP-65 MIP-86<br />

Type of kit:<br />

- PGD-43 PGD-44 PGD-54 PGD-64 PGD-65 PGD-86


MODULAR CHASSIS OF DEVICE<br />

CH - type chassis for installation of modular switchgear<br />

- Assembly and wiring can install out of enclosure<br />

- Installation can be found in the enclosure<br />

- Mounting rails can be fitted in 7 different depths<br />

- The sunk base plates allow to use non-modular devices too.<br />

PARTS OF CHASSIS<br />

- Side frame (1)<br />

- DIN rail for modular devices (2)<br />

- Holder for rail or plates (3)<br />

- Holder for mounting plates (4)<br />

- Front plate / cover plate (5) Type-symbol:<br />

- Base plate (6) Type-symbol: PB<br />

Example: CH 69/3:<br />

Number of moduls 3×23 in 3 lines, 23 moduls by lines.<br />

CC


In case of opened door the front plates provide IP 2X degree of protection too.<br />

The different arrangements can be formed according to space requirement of cables and<br />

devices.<br />

F<br />

R<br />

O<br />

N<br />

T<br />

P<br />

L<br />

A<br />

T<br />

E<br />

S<br />

For MIP-43 MIP-44 MIP-54 MIP-64 MIP-65 MIP-86<br />

enclosures: /CH24/2 /CH36/2 /CH54/3 /CH54/3 /CH69/3 /CH116/4<br />

Chassis:<br />

Number of 24 36 54 54 69 116<br />

modules:<br />

Number of<br />

lines:<br />

B<br />

A<br />

S<br />

E<br />

P<br />

L<br />

A<br />

T<br />

E<br />

S<br />

ARRANGEMENTS OF THE FRONT PLATES<br />

SETTING-IN OF THE CHASSIS IN MIP TYPES<br />

CH24 CH36 CH54 CH54 CH69 CH116<br />

2x12 2x18 3x18 3x18 3x23 4x29<br />

SETTING-IN OF THE FRONT AND BASE PLATES IN THE CHASSIS<br />

for enclousures<br />

300 mm 400 mm 500 mm 600 mm<br />

width width width width<br />

for 202 mm CC-400/ CC-400/ CC-400/ CC-500/ CC-600/<br />

hight 202 202 202 202 202<br />

for 178 mm CC-300/ CC-400/ CC-400/ CC-400/ CC-600/<br />

hight 178 178 178 178 178<br />

for 152 mm CC-400/ CC-400/ CC-400/ CC-500/ CC-600/<br />

hight 152 152 152 152 152<br />

for 202 mm PB-400/ PB-400/ PB-400/ PB-500/ PB-600/<br />

hight 202 202 202 202 202<br />

for 178 mm PB-300/ PB-400/ PB-400/ PB-400/ PB-600/<br />

hight 178 178 178 178 178<br />

for 152 mm PB-400/ PB-400/ PB-400/ PB-500/ PB-600/<br />

hight 152 152 152 152 152


OTHER ACCESSORIES<br />

LOCKS<br />

1 PDB - DIN 3.0 lock with double bit<br />

EKD - double handle<br />

2 LLT - triangular key<br />

PTT - lock with triangular head, 11 mm<br />

3 PCM - double handle with key lock<br />

PCM/3P - double handle with key lock, three point close<br />

4 EC -stainless steel padlock<br />

5 PCC - stainless steel padlock<br />

6 EKDB - sunk handle for different locks<br />

CPI-DE - swing lock for inner doors<br />

CPL-LL - key lock for inner doors<br />

DP - outlet of condensation water<br />

DVG - ventillation device


APPLICATIONS<br />

A system of enclosures made of hot moulded fibreglass reinforced polyester (GRP) with a high<br />

pressure technology. They are halogen free.<br />

The enclosures of the <strong>MINIPOL</strong> System is a multipurposly usable product-family. Enclosures are<br />

mountable on wall, on console and on the pick of pole.<br />

High degree of protection (IP 66) meets the requirement of outdoor application. They can be used<br />

in all kids of communication, electrical, pneumatical and hydraulical installation.<br />

Rated insulation voltage of the enclosures is 690 V 50 Hz.<br />

The base is made in one piece, garanteeing optimal avaibililty in the interior and increasing the<br />

impact resistance. They offer optimal security for humans and animals because of the double<br />

insulation characteristics.<br />

The enclosures are available with flat or transparent doors in 7 different size from 300×250×140<br />

mm up to 800×600×300 mm. They are symmetrical and reversible in many cases. The wide range<br />

of accessories gives an extra using possibility to the <strong>MINIPOL</strong> range.

Hooray! Your file is uploaded and ready to be published.