Battery voltage(V)<br />

(V/12V)<br />

15.6<br />

15.0<br />

14.4<br />

13.8<br />

13.2<br />

Capacity(%)<br />

Life(years)<br />

12.0<br />

9.6<br />

O<br />

Discharge characteristic (20 C)<br />

0<br />

1 2 3 5 10 20 30 60 2 3 5 10 20<br />

min h<br />

Discharge time<br />

(V/8V)<br />

10.4<br />

10.0<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

9.6<br />

9.2<br />

8.8<br />

Relationship between<br />

charging voltage andtemperature<br />

(V/6V)<br />

7.8<br />

7.5<br />

7.2<br />

6.9<br />

6.6<br />

(V/4V)<br />

5.2<br />

5.0<br />

4.8<br />

4.6<br />

4.4<br />

(V/CELL)<br />

2.6<br />

2.5<br />

2.4<br />

2.3<br />

2.2<br />

CYCLE USE<br />

STAND BY USE<br />

-10 0 10 20 30 40 50 60<br />

o<br />

Ambient temperature( C)<br />

Life characteristics ofstandby use<br />

0<br />

0 2 4 6 8 10 12<br />

Life(year)<br />

15<br />

10<br />

5<br />

0<br />

Testing conditions:floating voltage: 2.27 to2.30V/Cell<br />

o o<br />

ambient temperature: 20 C(68 F)<br />

Temperature effects on float life<br />

2.30V/Cell<br />

10 20 30 40 50<br />

o<br />

Temperature( C)<br />

THE INTERNATIONAL CERTIFICATION NETWORK<br />

ISO9001:2000<br />

MH25860<br />

Capacity(%)<br />

G4M19906-9202-E-16<br />

Charged<br />

Volume<br />

<strong>CT12</strong>-<strong>105X</strong> 12V105Ah<br />

(%) (XCA) (V)<br />

Charge characteristic curve<br />

Constant voltage charge characteristic<br />

o<br />

(0.25CA, 20 C)<br />

140<br />

120 0.25<br />

15.0<br />

CHARGED VOLUME<br />

100<br />

0.20<br />

14.0<br />

CHARGE VOLTAGE<br />

80<br />

60<br />

0.15<br />

13.0<br />

40<br />

0.10<br />

12.0<br />

20<br />

0.05<br />

11.0<br />

CHARGING CURRENT<br />

0 0<br />

0 2 4 6 8 10 12 14 16 18 2 0<br />

Charging time (hours)<br />

Capacity(%)<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

Current<br />

Voltage<br />

o<br />

40 C<br />

Shenzhen Center <strong>Power</strong>Tech. Co., Ltd.<br />

Center <strong>Power</strong> IndustrialPark, TongfuIndustrial District DapengTown, 518120 Shenzhen, China<br />

Tel: (+86-755) 8431 8088 Fax: (+86-755) 84318038 E-mail: sales@vision-batt.com<br />

Copy Right ShenzhenCenter <strong>Power</strong> Technology Co., Ltd (Edition 2003-9)<br />

Page 2 of 2<br />

Capacity (%)<br />

Self-discharge characteristic<br />

o<br />

30 C<br />

o<br />

20 C<br />

40 0 2 4 6 8 10 12 14 1 6 18 20<br />

Storage time: months<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Cycle service lifein relation to<br />

depth of discharge<br />

100% D.O.D. 50% D.O.D. 30% Depth of discharge<br />

0 200 400 600 800 1000 1200 1400<br />

Number of cycles(cycles)<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

Temperature effects on capacity<br />

0. 1C<br />

0.2C<br />

1. 0C<br />

2. 0C<br />

0<br />

-20 -10 0 10 20 30 40 50<br />

o<br />

Temperature( C)<br />

www.vision-batt.com