VISION CT12-105X Manual - Fusion Power System
VISION CT12-105X Manual - Fusion Power System
VISION CT12-105X Manual - Fusion Power System
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Battery voltage(V)<br />
(V/12V)<br />
15.6<br />
15.0<br />
14.4<br />
13.8<br />
13.2<br />
Capacity(%)<br />
Life(years)<br />
12.0<br />
9.6<br />
O<br />
Discharge characteristic (20 C)<br />
0<br />
1 2 3 5 10 20 30 60 2 3 5 10 20<br />
min h<br />
Discharge time<br />
(V/8V)<br />
10.4<br />
10.0<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
9.6<br />
9.2<br />
8.8<br />
Relationship between<br />
charging voltage andtemperature<br />
(V/6V)<br />
7.8<br />
7.5<br />
7.2<br />
6.9<br />
6.6<br />
(V/4V)<br />
5.2<br />
5.0<br />
4.8<br />
4.6<br />
4.4<br />
(V/CELL)<br />
2.6<br />
2.5<br />
2.4<br />
2.3<br />
2.2<br />
CYCLE USE<br />
STAND BY USE<br />
-10 0 10 20 30 40 50 60<br />
o<br />
Ambient temperature( C)<br />
Life characteristics ofstandby use<br />
0<br />
0 2 4 6 8 10 12<br />
Life(year)<br />
15<br />
10<br />
5<br />
0<br />
Testing conditions:floating voltage: 2.27 to2.30V/Cell<br />
o o<br />
ambient temperature: 20 C(68 F)<br />
Temperature effects on float life<br />
2.30V/Cell<br />
10 20 30 40 50<br />
o<br />
Temperature( C)<br />
THE INTERNATIONAL CERTIFICATION NETWORK<br />
ISO9001:2000<br />
MH25860<br />
Capacity(%)<br />
G4M19906-9202-E-16<br />
Charged<br />
Volume<br />
<strong>CT12</strong>-<strong>105X</strong> 12V105Ah<br />
(%) (XCA) (V)<br />
Charge characteristic curve<br />
Constant voltage charge characteristic<br />
o<br />
(0.25CA, 20 C)<br />
140<br />
120 0.25<br />
15.0<br />
CHARGED VOLUME<br />
100<br />
0.20<br />
14.0<br />
CHARGE VOLTAGE<br />
80<br />
60<br />
0.15<br />
13.0<br />
40<br />
0.10<br />
12.0<br />
20<br />
0.05<br />
11.0<br />
CHARGING CURRENT<br />
0 0<br />
0 2 4 6 8 10 12 14 16 18 2 0<br />
Charging time (hours)<br />
Capacity(%)<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
Current<br />
Voltage<br />
o<br />
40 C<br />
Shenzhen Center <strong>Power</strong>Tech. Co., Ltd.<br />
Center <strong>Power</strong> IndustrialPark, TongfuIndustrial District DapengTown, 518120 Shenzhen, China<br />
Tel: (+86-755) 8431 8088 Fax: (+86-755) 84318038 E-mail: sales@vision-batt.com<br />
Copy Right ShenzhenCenter <strong>Power</strong> Technology Co., Ltd (Edition 2003-9)<br />
Page 2 of 2<br />
Capacity (%)<br />
Self-discharge characteristic<br />
o<br />
30 C<br />
o<br />
20 C<br />
40 0 2 4 6 8 10 12 14 1 6 18 20<br />
Storage time: months<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Cycle service lifein relation to<br />
depth of discharge<br />
100% D.O.D. 50% D.O.D. 30% Depth of discharge<br />
0 200 400 600 800 1000 1200 1400<br />
Number of cycles(cycles)<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
Temperature effects on capacity<br />
0. 1C<br />
0.2C<br />
1. 0C<br />
2. 0C<br />
0<br />
-20 -10 0 10 20 30 40 50<br />
o<br />
Temperature( C)<br />
www.vision-batt.com