09.11.2013 Views

Masoneilan_ValVue_OVD_fact_sheet_0712 / PDF 198kb - GE Energy

Masoneilan_ValVue_OVD_fact_sheet_0712 / PDF 198kb - GE Energy

Masoneilan_ValVue_OVD_fact_sheet_0712 / PDF 198kb - GE Energy

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>fact</strong> <strong>sheet</strong><br />

Key Features<br />

• Non-intrusive for normal process operation<br />

• Read-only field device data capability for internet safety<br />

• Configurable schedule for valve monitoring<br />

• Automated data analysis that supports root cause<br />

identification<br />

• HART ® and Foundation ® Fieldbus support for any digital<br />

valve positioner (1)<br />

• Patented data analysis with valve performance<br />

prediction models<br />

• Facilitated planning of shutdowns using built-in reports<br />

• Automatic saving and logging of results into a<br />

database<br />

• Stand-alone implementation or integration<br />

• Data export to Microsoft ® Excel ®<br />

• Historical view of key performance indicators (KPI)<br />

<strong>ValVue</strong> <strong>OVD</strong> Maintenance Dashboard:<br />

• Easily identify troubled valves<br />

• Columns sortable by importance<br />

• NAMUR 107 compliant symbols<br />

• One click to valve data<br />

Communication protocol support<br />

• HART (revision 5,6,7 )<br />

• Foundation Fieldbus (H1, HSE)<br />

External hardware for stand-alone application support<br />

• HART Modem (USB, Serial, Bluetooth)<br />

• MTL Multiplexer<br />

• Foundation Fieldbus PCMCIA card and USB interface<br />

Key performance indicators (KPI) with pass/fail criteria (2)<br />

Valve Friction<br />

Spring Initial<br />

Sprint Final<br />

Spring Rate<br />

Lag<br />

Response Time<br />

Setpoint Offset<br />

Setpoint Error<br />

Position Overshoot<br />

Oscillation Frequency<br />

Digital valve positioners support<br />

• SVI<br />

• SVI II (Standard and Advanced Diagnostics)<br />

• SVI II AP (Standard and Advanced Diagnostics)<br />

• SVi1000<br />

• FVP (Standard and Advanced Diagnostics)<br />

• Fisher ® DVC5000 / DVC6000 (Does not require PD tier) (3)<br />

• Valtek ® Logix Series (3)<br />

• Siemens SIPART (3)<br />

• Most Digital Valve Positioners with HART Command #3<br />

support<br />

• Any Foundation Fieldbus positioner<br />

Integration<br />

• AMS from Emerson Process Management (AMS OPC<br />

server required) (3)<br />

• PRM ® from Yokogawa ® Corporation (3)<br />

(1) Non <strong>GE</strong> <strong>Masoneilan</strong> device must support HART Command #3<br />

(2) Certain KPI require availability of actuator pressure measurement<br />

(3) Non <strong>GE</strong> <strong>Masoneilan</strong> device<br />

Operating System and Host Support<br />

Microsoft ® Windows operating system emerson ® AMS Device Manager yokogawa ® prm<br />

7 XP SP3 Vista SP1 2000 SP4 Server 2003 SP1 10.X 9.X 8.X 7.X 6.X 3.X >=2.20<br />

3 3 3 3 3 3 3 3 3 3 3 3<br />

* <strong>Masoneilan</strong>, <strong>ValVue</strong>, FVP, and SVI are trademarks of the General Electric Company.<br />

© 2012 General Electric Company. All rights reserved.<br />

Other company names and product names used in this document are the registered<br />

trademarks or trademarks of their respective owners.<br />

<strong>GE</strong>A19053 06/2012