27/04/04 © Söring Users manual RF-units<br />

Contents<br />

1. Introduction ................................................................................................................. 5<br />

2. Important notes regarding the operation of RF Surgery units ......................... 6<br />

2.1. Operating of RF Surgery Equipment ................................................................................................6<br />

2.2. User instructions ...................................................................................................................................6<br />

2.3. Prescribed safety checks ....................................................................................................................6<br />

2.4. Medical Product Log Book ..................................................................................................................6<br />

2.5.How to keep the instruction manual and the medical product log book .................................7<br />

2.6. Accident and damage report ..............................................................................................................7<br />

2.7 Modifications and repairs.....................................................................................................................7<br />

3. Physiological and physical fundamentals of RF Surgery.................................. 8<br />

3.1. Heating effect of RF currents in biological tissue........................................................................8<br />

3.1.1 Reaction of biological tissue to local overheating ...........................................................................9<br />

3.2 Methods of RF Surgery and electrical Signal Shapes.................................................................12<br />

3.2.1 Cutting ...................................................................................................................................................12<br />

3.2.2. Coagulation .........................................................................................................................................13<br />

3.2.3. Electrodessication..............................................................................................................................13<br />

3.2.5. Bipolar application technique ...........................................................................................................14<br />

3.2.5.1 Bipolar Automatic .........................................................................................................................................14<br />

4. Patient safety............................................................................................................. 15<br />

4.1. Patient placement................................................................................................................................15<br />

4.2. Attachment of patient electrode ......................................................................................................15<br />

4.4. Current carrying cables .....................................................................................................................18<br />

4.5. Dangers from inflammable and explosive media. .......................................................................19<br />

4.6 Instructions for special applications...............................................................................................19<br />

Arrangement of Switches, Sockets and displays of MBC 601.........................................................20<br />

Arrangement of Switches, Sockets and displays of MBC 600.........................................................21<br />

5.1. Description of controls and indicators..........................................................................................22<br />

5.1.1 Description of the Safety Equipment................................................................................................27<br />

5.2 Putting the equipment into operation .............................................................................................28<br />

5.2.1 Description of operational facilities ..................................................................................................28<br />

5.2.2 Preparation of equipment...................................................................................................................28<br />

5.2.3 Switching on the equipment...............................................................................................................28<br />

5.2.4. Adjustment of function fields ............................................................................................................29<br />

6. Accessories (extracts)............................................................................................. 30<br />

7. Cleaning, maintenance, disinfection and sterilization ..................................... 31<br />

8. Technical Data........................................................................................................... 32<br />

9. Technical safety checks.......................................................................................... 35<br />

1 not valid for MBC600<br />