Applications<br />
Motor monitoring with PTC in the<br />
winding:<br />
• For long starting and braking<br />
operations<br />
• For high switching frequencies<br />
• For increased ambient temperatures<br />
• When the cooling medium flow<br />
is restricted<br />
• For AC drive operation<br />
Highlights<br />
• All products are PTB-ATEX<br />
certified<br />
• Wire breakage and short circuit<br />
in the sensor circuit are displayed<br />
• Versions with hard-gold-plated<br />
<strong>relay</strong>s which are electronics<br />
compatible<br />
• Favorably priced compact device<br />
(A1 + 11 jumpered)<br />
• Either screw or cage clamp terminal<br />
connection system<br />
SIMIREL –<br />
<strong>3RN1</strong> <strong>thermistor</strong> <strong>motor</strong> <strong>protection</strong><br />
<strong>relay</strong>: Today, <strong>motor</strong> <strong>protection</strong> is so simple<br />
The power and lifetime of <strong>motor</strong>s is essentially limited by the winding temperature. Motor<br />
manufacturers integrate PTC sensors in the <strong>motor</strong> winding if more stringent requirements prevail – e. g.<br />
for high ambient temperatures or where cooling is restricted. The <strong>thermistor</strong> <strong>motor</strong> <strong>protection</strong> devices<br />
operate according to the closed-circuit principle, detect these limit temperatures and switch the output<br />
<strong>relay</strong> contacts.<br />
SIMIREL <strong>relay</strong>s<br />
Electrical Engineering from A to Z
SIMIREL <strong>3RN1</strong> <strong>thermistor</strong> <strong>motor</strong> <strong>protection</strong> for PTC <strong>thermistor</strong> temperature sensors<br />
Screw connection<br />
Thermistor <strong>motor</strong> <strong>protection</strong><br />
<strong>relay</strong>s for PTC <strong>thermistor</strong>s<br />
(type A PTCs)<br />
• Monostable version<br />
(closed-circuit principle),<br />
trips when the control<br />
voltage fails<br />
• All <strong>relay</strong>s (with<br />
AC/DC 24 V)<br />
have electrical<br />
isolation<br />
• 22.5 mm wide<br />
RESET Contacts Power supply<br />
voltage V s<br />
50/60 Hz V AC<br />
Order No.<br />
Compact evaluation devices, 1 LED<br />
Terminal A1 is connected to the<br />
common of the changeover contact<br />
Auto<br />
1 CO<br />
24 AC/DC<br />
230 AC<br />
<strong>3RN1</strong>0 00-1AB00<br />
<strong>3RN1</strong>0 00-1AM00<br />
Standard evaluation devices, 2 LEDs<br />
Short-circuit detection in the sensor circuit<br />
Holding on supply failure fct.<br />
Holding on supply failure fct.,<br />
short-circuits in the sensor circuit are<br />
displayed<br />
Holding on supply failure fct.<br />
short-circuits and wire<br />
breakage in the sensor circuit are detected<br />
Auto<br />
Manual/Remote 1)<br />
Manual/Remote 1)<br />
Manual/Auto/Remote<br />
Manual/Auto/Remote<br />
Manual/Auto/Remote<br />
1 NO + 1 NC<br />
2 CO<br />
1 NO + 1 NC<br />
2 CO<br />
1 NO + 1 NC<br />
2 CO<br />
2 CO<br />
2 CO, hard-gold-plated<br />
2 CO<br />
2 CO, hard-gold-plated<br />
24 AC/DC<br />
230 AC<br />
24 AC/DC<br />
230 AC<br />
24 AC/DC<br />
110/230 AC<br />
24 AC/DC<br />
230 AC<br />
24 AC/DC<br />
110/230 AC<br />
24 AC/DC<br />
230 AC<br />
24 AC/DC<br />
24 AC/DC<br />
24–240 AC/DC<br />
24–240 AC/DC<br />
<strong>3RN1</strong>0 10-1CB00<br />
<strong>3RN1</strong>0 10-1CM00<br />
<strong>3RN1</strong>0 10-1BB00<br />
<strong>3RN1</strong>0 10-1BM00<br />
<strong>3RN1</strong>0 11-1CB00<br />
<strong>3RN1</strong>0 11-1CK00<br />
<strong>3RN1</strong>0 11-1BB00<br />
<strong>3RN1</strong>0 11-1BM00<br />
<strong>3RN1</strong>0 12-1CB00<br />
<strong>3RN1</strong>0 12-1CK00<br />
<strong>3RN1</strong>0 12-1BB00<br />
<strong>3RN1</strong>0 12-1BM00<br />
<strong>3RN1</strong>0 12-1GB00<br />
<strong>3RN1</strong>0 13-1BB00<br />
<strong>3RN1</strong>0 13-1BW10<br />
<strong>3RN1</strong>0 13-1GW10<br />
1) Reset by either pressing the RESET button or interrupting the power supply voltage<br />
Price category 101<br />
www.siemens.com/simirel<br />
Automation and Drives<br />
Partner des Elektro-Großhandels<br />
Werner-von-<strong>Siemens</strong>-Str. 50<br />
D-91050 Erlangen, Germany<br />
<strong>Siemens</strong> AG<br />
The information provided in this brochure contains merely general descriptions<br />
or characteristics of performance which in case of actual use do not always apply<br />
as described or which may change as a result of further development of the<br />
products. An obligation to provide the respective characteristics shall only exist<br />
if expressly agreed in the terms of contract.<br />
© <strong>Siemens</strong> AG 2003<br />
Subject to change without prior notice 07/03<br />
Order No. E20001-A660-M102-X-7600<br />
Printed in Germany<br />
DISPO 18101<br />
21C7977 EGCD.52 3.05 SB 070325.0