Parameter to VDI 3267<br />
Type designation S 16 VH S 16 Y<br />
General parameters<br />
Designation<br />
Directional control valve<br />
Type<br />
Spool-type valve<br />
Symbol<br />
See type key<br />
Mounting type<br />
Flange<br />
Line connector<br />
Subplate<br />
Weight of valve<br />
[kg]<br />
1 actuator 9.7<br />
2 actuators 10,3<br />
Weight of subplate [kg]<br />
G 3/4 9.0<br />
G 1 9.0<br />
Weight ofdouble-throttle<br />
non-return valve [kg] 1.7<br />
Mounting position<br />
any<br />
Ambient temperature<br />
range ϑ u [°C] –20 to +50<br />
Nominal size 16<br />
Type description S 16 VH S 16 Y<br />
Hydraulic parameters<br />
Operating pressure<br />
range p [bar]<br />
X = extern 315<br />
Port P, A, B: X = intern 315 -<br />
Port T: X = extern 315<br />
Y = intern 160 -<br />
Control pressure 1) 8.5 1) 8.5<br />
to to<br />
p St [bar] 2) 315 315<br />
Control volume V St [cm 3 ]<br />
Symbol<br />
019, 020 8.4<br />
005, 008,<br />
009, 011 4.2<br />
013 4.9<br />
Temperature of<br />
max.<br />
pressure medium ϑ m [°C] +70<br />
Viscosity<br />
range ν [mm 2 /s] 12 to 500<br />
Flow valume Q [l/min] see characeristic<br />
curves<br />
1) V St min 10 bar for symbol 013<br />
2) For symbols 011 and 013 the control pressure is<br />
achieved by the precharge cartridge valve in P.<br />
Electrical parameters<br />
Operation<br />
VH<br />
Switching time 3) t e [ms] 50<br />
(pilot valve) t a [ms] 30<br />
No. of switchings/h approx. 15 000<br />
Rated voltage VU N [V] Standard voltages<br />
Connector input DC 24 AC 230 V<br />
40 ... 60 HZ<br />
± 10% + 5%/-10 %<br />
Special voltages on<br />
request<br />
Operation<br />
VH<br />
Current P 20 [W] 27<br />
draw<br />
P 20 [VA] ∼ -<br />
Duty cycle ED rel [%] 100<br />
Degree of protectionfor solenoid<br />
and elictrical connection to<br />
DIN 40 050 IP 65<br />
Electrical connection:<br />
see Type keys<br />
3) The main valve switching time is dependant on the<br />
control oil supply.<br />
Characteristic curves<br />
Pilot cartridge in P<br />
For all symbols apart from 013<br />
Symbol<br />
7500901.06.12.08 Design subject to change without notice<br />
3