Dimensional Drawings<br />
Directional valve: See subplate dimensioned drawing for the dimensions of the connection layout.<br />
Interface S16<br />
DIN 24340 - A 16 / ISO 4401<br />
Tightening torque:<br />
M 15 DIN 912 - 10.9 = 17.6 Nm<br />
M 15 DIN 912 - 10.9 = 13 Nm<br />
M 10 DIN 912 - 10.9 = 62 NM<br />
El. connection<br />
11 and 13<br />
Solenoid can<br />
be rotated 90 o<br />
M 5<br />
Pilot valve<br />
S6 VH...<br />
∼190 AC version<br />
∼1188 DC version<br />
M6<br />
M10<br />
Main valve<br />
S16<br />
Section C-D<br />
Section A-B<br />
Screw not required for<br />
“internal control oil<br />
return“ version<br />
Screw not required for<br />
“internal control oil feed“<br />
version<br />
Pilot valve in connection P<br />
(depends on symbol and control type)<br />
6 Design subject to change without notice<br />
7500901.06.12.08