4 Table of Contents WAGO-I/O-SYSTEM 750<br />

750-495 3-Phase Power Measurement Module<br />

5.3.2 Definition of Input Data Words .......................................................... 42<br />

5.4 Process Image Descriptions .................................................................... 46<br />

5.4.1 Collection AC Measured Values (010) .............................................. 47<br />

5.4.2 Collections for Harmonics Analysis (020, 021, 022) ......................... 48<br />

5.4.3 Building-up the Measured Values ...................................................... 50<br />

5.5 Collections of Measured Values ............................................................. 51<br />

5.5.1 Collection 010 – AC Measured Values .............................................. 51<br />

5.5.2 Collection 020 – Harmonics Analysis on L1 ..................................... 56<br />

5.5.3 Collection 021 – Harmonics Analysis on L2 ..................................... 57<br />

5.5.4 Collection 022 – Harmonics Analysis on L3 ..................................... 58<br />

5.6 Examples of Calculating the Measured Values from the Process Values59<br />

6 Mounting ..................................................................................................... 63<br />

6.1 Mounting Sequence ................................................................................. 63<br />

6.2 Inserting and Removing Devices ............................................................ 64<br />

6.2.1 Inserting I/O Module .......................................................................... 64<br />

6.2.2 Removing the I/O Module .................................................................. 65<br />

7 Connect Devices ......................................................................................... 66<br />

7.1 Connecting a Conductor to the CAGE CLAMP ® ................................... 66<br />

7.2 Voltage Measurement ............................................................................. 67<br />

7.3 Current Measurement .............................................................................. 68<br />

7.3.1 Current Measurement on a Motor ...................................................... 68<br />

7.3.2 Current Transformers ......................................................................... 69<br />

7.3.3 ‘Rogowski’ Coils ................................................................................ 71<br />

7.3.4 Additional Measuring Instruments in a Current Path ......................... 71<br />

7.4 Power Measurement ................................................................................ 72<br />

8 Commissioning ........................................................................................... 73<br />

8.1 Configuration with WAGO-I/O-CHECK ............................................... 74<br />

8.1.1 “Application“ Tab .............................................................................. 77<br />

8.1.2 "Phase L1”, “Phase L2”, “Phase L3” Tabs ........................................ 79<br />

8.1.3 “Neutral Conductor” Tab ................................................................... 81<br />

8.1.4 “I/O Module“ Tab............................................................................... 82<br />

8.1.5 “Energy“ Tab ...................................................................................... 85<br />

8.1.6 "Factory Settings" Tab ....................................................................... 87<br />

8.2 Displaying the Measured Values via WAGO-I/O-CHECK .................... 89<br />

9 Diagnostics .................................................................................................. 98<br />

10 Appendix ..................................................................................................... 99<br />

10.1 Examples of CSV Data Files ................................................................... 99<br />

10.1.1 Snapshot ............................................................................................. 99<br />

10.1.2 Measurement Recording ................................................................... 103<br />

10.2 Factory Settings ..................................................................................... 104<br />

10.3 Register Assignment ............................................................................. 106<br />

10.4 Parameter Assignment .......................................................................... 112<br />

List of Figures .................................................................................................... 119<br />

List of Tables ...................................................................................................... 120<br />

Manual<br />

Version 1.0.0