<strong>Deka</strong> ordnance batteries outrank the<br />

requirements for power and reliability.<br />

■ Specially designed to meet military specifications.<br />

Certificate of compliance available on request.<br />

■ Available wet or dry.<br />

■ Up to 750 CCA and 230 min. reserve capacity<br />

■ Maintenance-free types feature calcium grids<br />

with microporous polyethylene envelope<br />

separators and double glass-mat insulation.<br />

■ Screw-in vents are submersible to 4-feet<br />

underwater and make battery maintainable<br />

in case of accidental overcharging.<br />

■ Full-frame compu-cast grids, heavy-duty<br />

plates, high density oxide and pure,<br />

demineralized electrolyte prevent internal<br />

shorts and withstand high cycling service<br />

for longest battery life.<br />

■ Durable ribbed polypropylene case<br />

provides protection in abusive applications.<br />

■ Special leak resistant cover keeps battery<br />

compartments clean and dry up to a 45° tilt.<br />

■ Anchor lock elements resist vibration<br />

damage for longer service life.<br />

■ Most models include handles for ease<br />

of transportation and installation.<br />

■ Over 250 quality control<br />

checks assure reliability<br />

and long service life.<br />

■ Made in the U.S.A.…<br />

Your assurance of quality.<br />

GROUP<br />

NO.<br />

TYPE<br />

NO.<br />

FOOTNOTES<br />

FOOTNOTES:<br />

6 - Black cover / Brown case<br />

11- Low maintenance-low antimony grids<br />

12- Hybrid construction<br />

17- <strong>Inc</strong>ludes handle<br />

PERFORMANCE LEVEL<br />

CCA<br />

@ 0°F<br />

RESERVE<br />

CAPACITY<br />

VOLTS<br />

20 AH<br />

RATE<br />

ORDNANCE<br />

QTS.<br />

OF<br />

ACID<br />

APPROXIMATE<br />

WEIGHT<br />

WET DRY L W H<br />

DISTRIBUTED BY:<br />

MAXIMUM OVERALL DIMENSIONS<br />

(in inches and mm)<br />

2HN 2HND 12,21,25,32 400 75 45 12 2.9 ––– 25.0 10 1 ⁄4 260 5 1 ⁄4 133 9 229<br />

4HN 4HND 11,17,21,25,32 235 28 21 24 2.9 ––– 27.5 10 1 ⁄4 260 5 1 ⁄4 133 9 229<br />

6TL 6TMF 6,17,21,25,30 750 230 120 12 7.6 73.0 52.0 11 1 ⁄4 286 10 1 ⁄2 267 9 229<br />

– All batteries manufactured in polypropylene cases except where noted.<br />

– Maintenance-free batteries have microporous, polyethylene envelope separators.<br />

“ P O W E R E D F O R P E R F O R M A N C E ” ®<br />

2HND – dry ordnance battery<br />

4HND – dry ordnance battery<br />

6TMF – wet maintenance-free ordnance battery<br />

21- Anchor lock elements<br />

25- With individual vent caps<br />

30- Available dry-add “D” suffix to part number<br />

32- Available dry charged only<br />

LEAD<br />

Pb<br />

RECYCLE<br />

RETURN<br />

ORDNANCE BATTERIES<br />

Lyon Station, PA 19536-0147 • Phone: 610-682-6361 • Fax: 610-682-4781<br />

Order Department Hotline: 610-682-4231<br />

www.dekabatteries.com • e-mail: eastpenn@eastpenn-deka.com


The<br />

® Ordnance Battery<br />

Calcium Maintenance-Free Advantage<br />

Many battery manufacturers market hybrid batteries as their maintenance-free line.<br />

A hybrid battery is made with one calcium and one low antimony plate. These designs may<br />

have low initial cost, but are vastly inferior in performance when compared to genuine calcium<br />

technology. All <strong>Deka</strong> Maintenance-Free Ordnance batteries are engineered with pure<br />

calcium grids. They contain no antimony, ensuring longest optimal performance.<br />

CCs LOSS PER CYCLE<br />

Water Loss Rate on SAE J240b Life<br />

0.60<br />

0.50<br />

0.40<br />

Hybrid<br />

0.30<br />

0.20<br />

Calcium<br />

0.10<br />

0.00<br />

0 1000 2000 3000 4000 5000 6000 7000 8000<br />

CYCLES<br />

CHART A<br />

Advantage #1 - DECREASED WATER LOSS<br />

Chart A clearly shows the dramatic difference in the<br />

rate of water loss between <strong>Deka</strong> Calcium Maintenance-<br />

Free Ordnance and hybrid batteries. As a hybrid<br />

battery cycles, antimony transfers from the positive<br />

to the negative plate. This antimony buildup actually<br />

decreases the voltage, which causes the battery to<br />

gas and lose water.<br />

<strong>Deka</strong> pure calcium batteries create no harmful<br />

antimony, and therefore use less water as they cycle.<br />

Advantage #2 - SUPERIOR RESERVE CAPACITY<br />

Chart B compares the percent of reserve capacity retained while in stock,<br />

without recharging. Over a 12-month period, the <strong>Deka</strong> Calcium Maintenance-<br />

Free Ordnance battery retains more than 80 percent of its rated capacity,<br />

while the hybrid design loses over 60 percent. In fact, after 12 months<br />

without charging, many hybrid batteries will not hold a charge.<br />

Calcium maintenance-free batteries recharge easily, with no capacity loss.<br />

Advantage #3 - LOWER STAND LOSS<br />

Another factor to consider when comparing batteries is the specific gravity<br />

and open circuit voltage loss per day. Every battery suffers some stand loss<br />

from self-discharge. The lower the stand loss, the more powerful the battery.<br />

As illustrated in Chart C, <strong>Deka</strong> Calcium Maintenance-Free Ordnance batteries<br />

experience dramatically lower stand loss than hybrid designs.<br />

Percent of Reserve<br />

Capacity Retained<br />

After Stand Test<br />

(No Boost) 72°F - 365 Days<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

00%<br />

CHART B<br />

Calcium<br />

Hybrid<br />

Specific Gravity<br />

Loss Per Day<br />

72°F - 365 Days<br />

.00032<br />

.00028<br />

.00024<br />

.00020<br />

.00016<br />

.00012<br />

.00008<br />

.00004<br />

.00000<br />

CHART C<br />

Calcium<br />

Hybrid<br />

Specific Gravity (SpG)<br />

Rise During Recharge<br />

1230<br />

1180<br />

1160<br />

SpG<br />

CHART D<br />

1 2 3 4 5 6<br />

HOURS<br />

Hybrid<br />

Calcium<br />

Advantage #4 - RECHARGEABILITY<br />

<strong>Deka</strong> Calcium Maintenance-Free Ordnance<br />

batteries recharge as well as or better than<br />

hybrid designs. In fact, as Chart D shows,<br />

a <strong>Deka</strong> Calcium Maintenance-Free battery<br />

starting at a lower specific gravity has virtually<br />

the same state of charge as a hybrid battery<br />

after six hours of charging.<br />

Conclusion<br />

<strong>Deka</strong> Calcium Maintenance-Free Ordnance<br />

batteries simply perform better in every<br />

significant test. When performance matters,<br />

depend on <strong>Deka</strong>.<br />

E.P.M. Form No. 0226 Rev. 7/08<br />

© 2008 by EPM Printed in U.S.A.<br />

All data subject to change without notice.<br />

No part of this document may be copied or reproduced, electronically<br />

or mechanically, without written permission from the company.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!