HMW-<strong>2230</strong> T6<br />

Powered by:<br />

<strong>MTU</strong> 16V 4000 G83<br />

2,228 <strong>kW</strong> at 60 Hz<br />

Generating Set Performance<br />

60 Hz<br />

SERVICE<br />

Rated output<br />

Active power output *<br />

Rated speed<br />

Standard Voltage<br />

Voltage available<br />

kVA<br />

<strong>kW</strong><br />

r.p.m.<br />

V<br />

V<br />

P.R.P<br />

(1)<br />

2.600<br />

2,080<br />

1,800<br />

480<br />

480/277 - 440/254<br />

Performance data refers to Standard Reference Conditions of ISO 8528 : + 25 °C , 100 m ALT, relative humidity 30 %<br />

During running-in period the output increases by approx. 5 % which is taken into consideration at delivery.<br />

Power reduction acc. to DIN ISO 3046. Standard values: Above 100 m ALT approx. 1 % per 100 m. Above 25 °C (77 °F) approx. 4 % per 10 °C (50 °F).<br />

* Considering cos phi= 0,8<br />

Standby<br />

(2)<br />

2.785<br />

2,228<br />

Prime Mover Performance<br />

1.800 r.p.m.<br />

SERVICE<br />

Rated output<br />

Manufacturer<br />

Engine model<br />

4 stroke <strong>Diesel</strong> Engine - Injection type<br />

Aspiration type<br />

Cylinders, number and arrangement<br />

Bore x stroke<br />

Total displacement<br />

Cooling system<br />

Lube oil <strong>spec</strong>ifications<br />

Compression ratio<br />

Specific fuel consumption (P.R.P)<br />

Specific oil consumption (at full load)<br />

Lube oil maximum capacity<br />

Total coolant capacity<br />

Speed governor<br />

Air filter<br />

<strong>kW</strong><br />

2,280<br />

<strong>MTU</strong><br />

16V 4000 G83<br />

DIRECT<br />

2,508<br />

TURBOCHARGED AND AFTERCOOLED<br />

16 - V<br />

mm 170 x 210<br />

L<br />

76.3<br />

WATER<br />

SAE 15 W 40<br />

16.5 : 1<br />

g / <strong>kW</strong>h<br />

208<br />

%<br />

1.0<br />

L<br />

240<br />

L<br />

Type<br />

Type<br />

P.R.P<br />

(1)<br />

175<br />

Electronic, system MDEC<br />

DRY<br />

Standby<br />

(2)<br />

(1) Prime Power (P.R.P.) - ISO 8528: prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year,<br />

between stated maintenance intervals. The permissible average power output during a 24 hours period shall not exceed 80% of the prime power. 10% overload available for governing<br />

purposes only.<br />

(2) Max Stand-by power (ISO 3046 Fuel Stop power): power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100%<br />

loads 25 h per year - 90% loads 200 h per year No overload available. Applicable in case of failure of the main in areas of reliable electrical network.<br />

Synchronous Generator *<br />

Poles<br />

Winding connections (standard)<br />

Frame mounting<br />

Insulation<br />

Enclosure (according to IEC-34-5)<br />

Exciter system<br />

Voltage regulator<br />

Steady voltage precision<br />

*Alternator used by Gensets meet the requirements of following Standard: BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.<br />

Nº<br />

class<br />

4<br />

Star - serie<br />

SAE 0 - 21”<br />

H<br />

IP 23<br />

Self-regulating Brushless<br />

A.V.R (Electronic)<br />

within ± 1.5% from no load to full loading with cosφ=0.8÷1


HMW <strong>2230</strong> T6 - 2,228 <strong>kW</strong> at 60 Hz<br />

Generating Set Installation Data<br />

EXHAUST SYSTEM<br />

Max. exhaust temperature at full load<br />

Exhaust gas flow<br />

Maximum allowed back pressure<br />

Recommended exhaust pipe size for L= 5 m<br />

AIR REQUIREMENT<br />

Air requirement for combustion<br />

at 100% load / rated speed<br />

ELECTRIC STARTING SYSTEM<br />

Starting motor output<br />

Minimum recommended battery capacity<br />

Auxiliary voltage<br />

LIQUID CAPACITY<br />

Lube oil system including sump, filters, etc.<br />

FUEL TANK CAPACITY<br />

Open Skid Genset<br />

Soundproofed<br />

º C<br />

º F<br />

m 3 /s<br />

mbar<br />

mm<br />

m 3 /min<br />

ft 3 /min<br />

<strong>kW</strong><br />

CV<br />

Ah<br />

Vcc.<br />

L<br />

1,800 r.p.m.<br />

480<br />

896<br />

7.6<br />

85<br />

-<br />

180<br />

6,356.7<br />

-<br />

-<br />

-<br />

24V<br />

300<br />

L<br />

999<br />

L<br />

999<br />

Generating Set transport data<br />

WEIGHT AND DIMENSIONS OPEN SKID GENSET<br />

Length<br />

Width<br />

Height<br />

Shipping volume seaworthy (Standard supplier)<br />

Dry weight (with standard accessories)<br />

m - ft<br />

m - ft<br />

m - ft<br />

m 3 - ft 3<br />

kg - lb<br />

5.85<br />

1.8<br />

2.40<br />

-<br />

-<br />

-<br />

19.18<br />

5.9<br />

7.87<br />

25.27 - 890.58<br />

-<br />

WEIGHT AND DIMENSIONS SOUNDPROOFED CONTAINER 40''<br />

Length<br />

Width<br />

Height<br />

Shipping volume seaworthy (Standard supplier)<br />

Dry weight (with standard accessories)<br />

Sound level at 7m<br />

* Weights and dimmensions approximate. To consult in factory.<br />

m - ft<br />

m - ft<br />

m - ft<br />

m 3 - ft 3<br />

kg - lb<br />

dB(A)<br />

12.19<br />

2.44<br />

2.59<br />

67.4<br />

17,700<br />

-<br />

-<br />

-<br />

-<br />

-<br />

39.99<br />

7.97<br />

8.49<br />

39,021<br />

70 -