Construction details<br />

Specific plastic material<br />

The manifolds are made with a <strong>specifically</strong> selected polymer <strong>for</strong> heat<strong>in</strong>g and cool<strong>in</strong>g system applications. The basic characteristics <strong>for</strong> this use are:<br />

- high stra<strong>in</strong> resistance while ma<strong>in</strong>ta<strong>in</strong><strong>in</strong>g good ultimate elongation<br />

- good resistance to crack propagation<br />

- very low moisture absorption, <strong>for</strong> constant mechanical behaviour<br />

- high abrasion resistance due to medium constant flow<br />

- per<strong>for</strong>mance stability to temperature changes<br />

- compatibility with the glycols and additives used <strong>in</strong> the circuits<br />

These basic material characteristics, comb<strong>in</strong>ed with the appropriate shap<strong>in</strong>g of the most highly stressed areas, enable a comparison with the<br />

metals typically used <strong>in</strong> the construction of distribution manifolds.<br />

Return manifold<br />

The return manifold is equipped with built-<strong>in</strong> shut-off valves. Us<strong>in</strong>g<br />

the shut-off valve with a manual knob, the flow rate to the s<strong>in</strong>gle<br />

circuits can be reduced so much as to shut off the circuit<br />

completely. The valve is equipped with a sta<strong>in</strong>less steel control<br />

stem <strong>in</strong> a s<strong>in</strong>gle piece, with a double O-r<strong>in</strong>g seal. The rubber<br />

obturator is specially shaped to m<strong>in</strong>imize the losses of head and<br />

the noise produced by the flow of the medium, prevent<strong>in</strong>g the seal<br />

seat from possibly stick<strong>in</strong>g.<br />

The valves are fitted to accommodate thermo-electric actuator <strong>in</strong> order<br />

to automate their action upon receiv<strong>in</strong>g a signal from an ambient<br />

thermostat.<br />

Flow manifold<br />

The flow manifold is equipped with flow meters and built-<strong>in</strong> flow rate<br />

balanc<strong>in</strong>g valves.<br />

Us<strong>in</strong>g the balanc<strong>in</strong>g valve with the special tapered obturator, the<br />

flow rate to the s<strong>in</strong>gle circuits can be adjusted accurately as<br />

required, with the sett<strong>in</strong>g be<strong>in</strong>g read off the s<strong>in</strong>gle flow meter with a<br />

scale of 1-4 l/m<strong>in</strong>. This simplifies and speeds up the operation of<br />

calibrat<strong>in</strong>g the circuit, with no need <strong>for</strong> reference graphs. After<br />

balanc<strong>in</strong>g, the valve can be locked <strong>in</strong> position by means of its<br />

tamper-proof cover.<br />

This valve makes it possible to seal off the s<strong>in</strong>gle circuit should this<br />

be necessary.