Tech News Letter :CCC/June/EDTech/11 Author :<strong>Schneider</strong> Technical Support Team<br />

SUBJECT<br />

Rev : 00 Last Modified On- 04/06/2012<br />

INFORMATION<br />

CONTENTS<br />

TARGTED<br />

AUDIENCE<br />

A new firmware version v4.2 released for the EGX300 gateway.<br />

System Integrator, Panel Builder, Marketing, OEMs, Tech Support, End User.<br />

FAMILY<br />

FAMILY: Power Monitoring Hardware<br />

PRODUCT: EGX300<br />

PICTURE<br />

NEW<br />

EVOLUTION<br />

The PowerLogic EGX300 is an integrated gateway-server that requires only a web<br />

browser and Ethernet network to log and display real-time data and trend plots<br />

from up to 64 PowerLogic system devices, including other gateway devices on the<br />

same network and any other communicating device operating under the Modbus<br />

RS 485 protocol.<br />

Now the new firmware v4.2 has been released with EGX300 improvements and<br />

additional device support.<br />

> Added NaN detection for PM9C real time pages.<br />

> Added the following devices:---<br />

- EM3150, EM3155<br />

- EM3250, EM3255<br />

- EM3550, EM3555<br />

- Acti 9 SmartLink<br />

Please refer to PowerLogic.com or <strong>Schneider</strong> <strong>Electric</strong> website for access to the new<br />

firmware.<br />

<strong>Schneider</strong> <strong>Electric</strong> –Technical Support Team, In-Care@schneider-electric.com 1


SUBJECT<br />

TARGTED<br />

AUDIENCE<br />

CONTENTS<br />

Distributor, Panel Builder, End User, Tech Support.<br />

Range: Micrologic<br />

QUESTION:<br />

What is the meaning of "max. reset table time" and "max. Break time" for the<br />

Micrologic 5.0/6.0/7.0 .<br />

FAQ1<br />

ANSWER:<br />

Max reset table time: It is the time during which a FAULT can appear, before the trip<br />

of the Circuit Breaker.<br />

Max break time: That is the maximum time for the Circuit breaker and the Micrologic<br />

to eliminate the fault.<br />

CONTENTS<br />

Range: Compact NSX<br />

QUESTION:<br />

Is it possible to mount Compact NS motor mechanism over Compact NSX MCCB.<br />

ANSWER:<br />

FAQ2<br />

A Compact NS motor mechanism can only be used on a Compact NS MCCB.<br />

However, Compact NSX motor mechanism may be used on a Compact NSX or NS<br />

MCCB.<br />

Find the answers you need with our new FAQ Technical Knowledge base. Over 1500<br />

regularly updated FAQs available.<br />

http://www.schneider-electric.co.in/sites/india/en/support/faq/faq_main.page<br />

<strong>Schneider</strong> <strong>Electric</strong> –Technical Support Team, In-Care@schneider-electric.com 2


SUBJECT<br />

TARGTED<br />

AUDIENCE<br />

System Integrator, Panel Builder, OEM’s, End User, Tech Support.<br />

CONTENTS<br />

Technote on “To establish the TeSys T communication with M340 PLC on Profibus<br />

using PRM module and do the programming of the TeSys T such as it should go in<br />

fallback mode in case of communication failure between M340 PLC & PRM<br />

module on Profibus network.”<br />

PICTURE<br />

TECHNICAL<br />

NOTE<br />

By referring this technical note, it is easy to configure & establish the communication<br />

between TeSys T & M340 PLC on profibus network. Also by making the custom logic<br />

in Tesys T, it is possible for Tesys T should go in fallback mode in case of<br />

communication failure between M340 PLC & PRM module.<br />

Refer the document for Technote Resolution, stepwise programming for this technical<br />

note and the custom logic made at the below link--<br />

http://www.largedocument.com/4/31d8f752/TeSys_T_as_it_should_go_in_fallback_p<br />

osition_in_case_of_communication_failure_between_M340_PLC_%26_PRM.zip<br />

CUSTOMER<br />

VALUE<br />

Customer can easily configure the Tesys T on profibus network using PRM module<br />

and establish the communication between TeSys T & M340 PLC.<br />

NEWS FLASH:<br />

“Creation of <strong>Schneider</strong> <strong>Electric</strong> Teachers, an NGO to promote voluntary commitment in educational<br />

and professional training programmes in the energy sector.”<br />

For more information, please refer the below webpage on <strong>Schneider</strong> website :-<br />

http://www.schneider-electric.co.in/india/en/press/press-releases/viewer-pressreleases.page?c_filepath=/templatedata/Content/Press_Release/data/en/local/2012/04/20120403_creat<br />

ion_of_schneider_electric_teachers_an_ngo_to_promote_voluntary_co.xml<br />

<strong>Schneider</strong> <strong>Electric</strong> –Technical Support Team, In-Care@schneider-electric.com 3

Hooray! Your file is uploaded and ready to be published.