NETWORK MODULE<br />

FOR CKS, CKV & CKX SERIES<br />

POWER PROCESSING AMPLIFIERS<br />

<strong>NC</strong>-<strong>NXS</strong> Full NexSys ® Functions & Control<br />

Product Information<br />

The <strong>NC</strong>-<strong>NXS</strong> is the ‘central’ NexSys interface module that supports all<br />

NexSys functions, including Load, AC and Line-Level Output <strong>Audio</strong><br />

Return Monitoring, Amplifier ID, Module ID, and NexSys-initiated<br />

Sequential Turn-On/Off. It fits in the Network bay located on the rear<br />

panel of <strong>Crest</strong> <strong>Audio</strong> CKS, CKV & CKX Series Power Processing<br />

amplifiers.<br />

CLASS 2<br />

WIRING MAY<br />

BE USED<br />

Output<br />

–<br />

+<br />

+<br />

A<br />

B<br />

– Signal<br />

Ground<br />

Lift<br />

Jumper<br />

Architects and Engineers Specifications - <strong>NC</strong>-<strong>NXS</strong>.<br />

The module shall plug into <strong>Crest</strong> <strong>Audio</strong> CKS or CKV Power Processing amplifiers in the<br />

Network bay. The module shall provide a 5mm 3-pin Phoenix connector for connection to a<br />

NexSys data bus and another for “daisy-chaining” to other amplifiers. Two rotary switches<br />

shall assign the module a NexSys data bus address.<br />

The <strong>NC</strong>-<strong>NXS</strong> requires both an <strong>NC</strong>-IPN (or any other programmable<br />

Input Processor <strong>NC</strong> Module) and a compatible Power/Output <strong>NC</strong><br />

Module. Connection to the NexSys data bus is via two 5mm three-pin<br />

Phoenix connector. Data bus address selection is via two recessed rotary<br />

switches. A Data LED indicates data signal presence.<br />

Firmware is upgradable thru the NexSys system.<br />

Features<br />

• Microprocessor-based NexSys network interface • Provides for all NexSys functions<br />

• NexSys-downloadable firmware permits easy future upgrade path • Data signal present LED<br />

• Twisted-pair data bus connection via two 5mm 3-pin Phoenix connectors • Monitoring of amplifier status<br />

• Level, load and line monitoring • Computer sequential turn-on/off (STO) control<br />

<strong>NC</strong>-<strong>NXS</strong> connections<br />

+<br />

--<br />

Designed & manufactured in the USA by:<br />

Model<br />

Name<br />

CKV 100<br />

CKV 200<br />

CKV 400<br />

CKV 800<br />

CKV 1600<br />

CKV 2400<br />

Network<br />

Output Power<br />

@70.7V<br />

50W<br />

100W<br />

200W<br />

400W<br />

800W<br />

1200W<br />

+ – + –<br />

NexSys Bus<br />

Data<br />

<strong>Crest</strong> <strong>Audio</strong> Inc.<br />

100 Eisenhower Dr.<br />

Paramus, New Jersey 07652 USA<br />

Model<br />

Name<br />

CKS 100<br />

CKS 200<br />

CKS 400<br />

CKS 800<br />

CKS 800-2<br />

CKS 1200-2<br />

CKS 1600-2<br />

--<br />

+<br />

2<br />

3<br />

4<br />

5<br />

6<br />

1<br />

7<br />

Output Power<br />

@8Ω/Ch.<br />

8<br />

F<br />

9<br />

Hi<br />

E<br />

D<br />

A<br />

50W<br />

100W<br />

200W<br />

400W<br />

400W<br />

600W<br />

800W<br />

Address<br />

C<br />

B<br />

2<br />

3<br />

4<br />

5<br />

6<br />

1<br />

7<br />

8<br />

F<br />

9<br />

Lo<br />

E<br />

D<br />

A<br />

C<br />

B<br />

Power<br />

Processing<br />

Modules<br />

Model<br />

<strong>NC</strong>-<strong>NXS</strong><br />

N-Coder<br />

Data<br />

Port<br />

A green LED shall indicate when data is being sent from or received by the module. The<br />

module shall require a Power/Output module which, by definition, provides the power supply<br />

required for the Network module. The module shall be fully compatible with <strong>NC</strong>-STI,<br />

<strong>NC</strong>-SAC, and <strong>NC</strong>-SLM Power/Output modules. The module shall be designated the <strong>Crest</strong><br />

<strong>Audio</strong> model <strong>NC</strong>-<strong>NXS</strong>.


BLOCK DIAGRAM<br />

NexSys<br />

Bus<br />

Conn.<br />

ADDRESS<br />

SWITCH<br />

NexSys<br />

SPECIFICATIONS<br />

<strong>NC</strong>-<strong>NXS</strong> Network Module<br />

PORT<br />

Full NexSys Functions & Control<br />

Microcomputer<br />

AMP STATUS<br />

FLASH<br />

Connectors: Two 5mm 3-pin Phoenix<br />

NexSys network connectors<br />

Controls: Two NexSys network address dials<br />

Indicators: Data present LED<br />

v. 2.1 4/7/97<br />

*A3300028*<br />

I/F<br />

ADC<br />

Internal<br />

Module Bus<br />

CONTROL OPTIONS<br />

VU<br />

LOAD SIGNALS<br />

LINE SIGNALS<br />

The <strong>NC</strong>-<strong>NXS</strong> microprocessor-based network<br />

interface provides for all NexSys functions,<br />

including:<br />

• Monitoring of amplifier status, level, load;<br />

• Line monitoring;<br />

• Sequential turn-on/off (STO) control.<br />

Refer to specific module data sheets for more<br />

information.<br />

<strong>Crest</strong> <strong>Audio</strong> reserves the right to make improvements in manufacturing or design which may affect specification. <strong>Crest</strong> <strong>Audio</strong> specification literature is available in electronic form to qualified users.<br />

Contact <strong>Crest</strong> <strong>Audio</strong> Inc. for more information. NexSys is a registered trademark of <strong>Crest</strong> <strong>Audio</strong> Inc. ©1996 <strong>Crest</strong> <strong>Audio</strong> Inc.<br />

<strong>Crest</strong> <strong>Audio</strong> Inc.<br />

100 Eisenhower Dr., Paramus NJ 07652 USA<br />

TEL: 201.909.8700 FAX: 201.909.8744<br />

http://www.crestaudio.com<br />

Printed in USA