NC-NXS - Crest Audio
NC-NXS - Crest Audio
NC-NXS - Crest Audio
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
NETWORK MODULE<br />
FOR CKS, CKV & CKX SERIES<br />
POWER PROCESSING AMPLIFIERS<br />
<strong>NC</strong>-<strong>NXS</strong> Full NexSys ® Functions & Control<br />
Product Information<br />
The <strong>NC</strong>-<strong>NXS</strong> is the ‘central’ NexSys interface module that supports all<br />
NexSys functions, including Load, AC and Line-Level Output <strong>Audio</strong><br />
Return Monitoring, Amplifier ID, Module ID, and NexSys-initiated<br />
Sequential Turn-On/Off. It fits in the Network bay located on the rear<br />
panel of <strong>Crest</strong> <strong>Audio</strong> CKS, CKV & CKX Series Power Processing<br />
amplifiers.<br />
CLASS 2<br />
WIRING MAY<br />
BE USED<br />
Output<br />
–<br />
+<br />
+<br />
A<br />
B<br />
– Signal<br />
Ground<br />
Lift<br />
Jumper<br />
Architects and Engineers Specifications - <strong>NC</strong>-<strong>NXS</strong>.<br />
The module shall plug into <strong>Crest</strong> <strong>Audio</strong> CKS or CKV Power Processing amplifiers in the<br />
Network bay. The module shall provide a 5mm 3-pin Phoenix connector for connection to a<br />
NexSys data bus and another for “daisy-chaining” to other amplifiers. Two rotary switches<br />
shall assign the module a NexSys data bus address.<br />
The <strong>NC</strong>-<strong>NXS</strong> requires both an <strong>NC</strong>-IPN (or any other programmable<br />
Input Processor <strong>NC</strong> Module) and a compatible Power/Output <strong>NC</strong><br />
Module. Connection to the NexSys data bus is via two 5mm three-pin<br />
Phoenix connector. Data bus address selection is via two recessed rotary<br />
switches. A Data LED indicates data signal presence.<br />
Firmware is upgradable thru the NexSys system.<br />
Features<br />
• Microprocessor-based NexSys network interface • Provides for all NexSys functions<br />
• NexSys-downloadable firmware permits easy future upgrade path • Data signal present LED<br />
• Twisted-pair data bus connection via two 5mm 3-pin Phoenix connectors • Monitoring of amplifier status<br />
• Level, load and line monitoring • Computer sequential turn-on/off (STO) control<br />
<strong>NC</strong>-<strong>NXS</strong> connections<br />
+<br />
--<br />
Designed & manufactured in the USA by:<br />
Model<br />
Name<br />
CKV 100<br />
CKV 200<br />
CKV 400<br />
CKV 800<br />
CKV 1600<br />
CKV 2400<br />
Network<br />
Output Power<br />
@70.7V<br />
50W<br />
100W<br />
200W<br />
400W<br />
800W<br />
1200W<br />
+ – + –<br />
NexSys Bus<br />
Data<br />
<strong>Crest</strong> <strong>Audio</strong> Inc.<br />
100 Eisenhower Dr.<br />
Paramus, New Jersey 07652 USA<br />
Model<br />
Name<br />
CKS 100<br />
CKS 200<br />
CKS 400<br />
CKS 800<br />
CKS 800-2<br />
CKS 1200-2<br />
CKS 1600-2<br />
--<br />
+<br />
2<br />
3<br />
4<br />
5<br />
6<br />
1<br />
7<br />
Output Power<br />
@8Ω/Ch.<br />
8<br />
F<br />
9<br />
Hi<br />
E<br />
D<br />
A<br />
50W<br />
100W<br />
200W<br />
400W<br />
400W<br />
600W<br />
800W<br />
Address<br />
C<br />
B<br />
2<br />
3<br />
4<br />
5<br />
6<br />
1<br />
7<br />
8<br />
F<br />
9<br />
Lo<br />
E<br />
D<br />
A<br />
C<br />
B<br />
Power<br />
Processing<br />
Modules<br />
Model<br />
<strong>NC</strong>-<strong>NXS</strong><br />
N-Coder<br />
Data<br />
Port<br />
A green LED shall indicate when data is being sent from or received by the module. The<br />
module shall require a Power/Output module which, by definition, provides the power supply<br />
required for the Network module. The module shall be fully compatible with <strong>NC</strong>-STI,<br />
<strong>NC</strong>-SAC, and <strong>NC</strong>-SLM Power/Output modules. The module shall be designated the <strong>Crest</strong><br />
<strong>Audio</strong> model <strong>NC</strong>-<strong>NXS</strong>.
BLOCK DIAGRAM<br />
NexSys<br />
Bus<br />
Conn.<br />
ADDRESS<br />
SWITCH<br />
NexSys<br />
SPECIFICATIONS<br />
<strong>NC</strong>-<strong>NXS</strong> Network Module<br />
PORT<br />
Full NexSys Functions & Control<br />
Microcomputer<br />
AMP STATUS<br />
FLASH<br />
Connectors: Two 5mm 3-pin Phoenix<br />
NexSys network connectors<br />
Controls: Two NexSys network address dials<br />
Indicators: Data present LED<br />
v. 2.1 4/7/97<br />
*A3300028*<br />
I/F<br />
ADC<br />
Internal<br />
Module Bus<br />
CONTROL OPTIONS<br />
VU<br />
LOAD SIGNALS<br />
LINE SIGNALS<br />
The <strong>NC</strong>-<strong>NXS</strong> microprocessor-based network<br />
interface provides for all NexSys functions,<br />
including:<br />
• Monitoring of amplifier status, level, load;<br />
• Line monitoring;<br />
• Sequential turn-on/off (STO) control.<br />
Refer to specific module data sheets for more<br />
information.<br />
<strong>Crest</strong> <strong>Audio</strong> reserves the right to make improvements in manufacturing or design which may affect specification. <strong>Crest</strong> <strong>Audio</strong> specification literature is available in electronic form to qualified users.<br />
Contact <strong>Crest</strong> <strong>Audio</strong> Inc. for more information. NexSys is a registered trademark of <strong>Crest</strong> <strong>Audio</strong> Inc. ©1996 <strong>Crest</strong> <strong>Audio</strong> Inc.<br />
<strong>Crest</strong> <strong>Audio</strong> Inc.<br />
100 Eisenhower Dr., Paramus NJ 07652 USA<br />
TEL: 201.909.8700 FAX: 201.909.8744<br />
http://www.crestaudio.com<br />
Printed in USA