<strong>Evaporative</strong><br />

Condensers


CONTENTS<br />

1 Product introduction<br />

2 Unique Features<br />

4 CXV-T: Induced Draft Combined Flow Condensers<br />

6 CXVB: Induced Draft Combined Flow Condensers<br />

8 pc2: Induced Draft Counterflow Condensers<br />

10 vca: Forced Draft Counterflow Condensers<br />

12 Series V: Forced Draft Counterflow Condensers<br />

14 Seismic Certification<br />

15 Containerized for export<br />

16 product comparison table


<strong>BAC</strong> offers the most complete line of evaporative condenser<br />

products in the world. With over 70 years of experience designing<br />

and manufacturing evaporative <strong>condensers</strong>, we have a unit to<br />

meet your application.<br />

T h e B e s t S t o p f o r . . .<br />

Over 70 years of experience<br />

Capacities ranging from 7 to 2,506 ammonia tons in a single unit<br />

Factory assembled accessories that reduce field labor<br />

The largest variety of footprints and air inlet configurations<br />

T h e O N L Y S t o p F o r . . .<br />

Guaranteed seismic performance through shake table testing<br />

IBC certified units verify functionality after an event through shake table testing<br />

Unique patented coil technologies for the CXVB and CXV-T Condensers


E v a p o r a t i v e C o n d e n s e r<br />

Unique Features<br />

CXV-T CXVB PC2<br />

Flow and<br />

Fan System<br />

Model<br />

Combined Flow,<br />

Induced Draft,<br />

Axial Fan<br />

Combined Flow,<br />

Induced Draft,<br />

Axial Fan<br />

Counterflow,<br />

Induced Draft,<br />

Axial Fan<br />

Cataloged<br />

Capacity<br />

Range<br />

645 - 1,888 Nominal Tons* 75 - 1,287 Nominal Tons* 41 - 2,506 Nominal Tons*<br />

Unique Features<br />

• Lowest refrigerant<br />

charge per ton<br />

• Lowest cost for large<br />

projects<br />

• Fewer piping<br />

connections<br />

• Layout flexibility<br />

• Easy maintenance<br />

• Lowest refrigerant<br />

charge per ton<br />

• Less piping<br />

connections<br />

• Layout flexibility<br />

• Shake table tested up<br />

to an S DS<br />

of 2.40g at<br />

grade<br />

• Easy maintenance<br />

• Replacement of<br />

existing installations<br />

• Redundant fan option<br />

on 12’ x 18’ units<br />

• Winter dry operation<br />

• Shake table tested up<br />

to an S DS<br />

of 3.75g at<br />

grade<br />

• Export units<br />

*Nominal Tons (R-717) at 96.3˚F CT, 20˚F SST, 78˚F EWB<br />

2


VCA VC1 Low Profile VCL<br />

Model<br />

Counterflow,<br />

Forced Draft,<br />

Axial Fan<br />

Counterflow,<br />

Forced Draft,<br />

Centrifugal Fan<br />

Counterflow,<br />

Forced Draft,<br />

Centrifugal Fan<br />

Flow and<br />

Fan System<br />

87 - 1,433 Nominal Tons* 7 - 1,140 Nominal Tons* 11 - 212 Nominal Tons*<br />

Catalogued<br />

Capacity<br />

Range<br />

• Easiest motor access<br />

• Independent fan<br />

drives<br />

• Pre-assembled<br />

platforms<br />

• 24’ long coils for<br />

reduced piping<br />

• Seismic rating<br />

up to 1.6g<br />

• Low sound by design<br />

• Indoor and outdoor<br />

installations<br />

• Split coils for multiple<br />

compressors (optional)<br />

• Copper connections<br />

(optional)<br />

• Export units<br />

• Low sound by design<br />

• Easily hidden<br />

• Indoor and outdoor<br />

installations<br />

• Single piece shipping<br />

and rigging<br />

Unique Features<br />

*Nominal Tons (R-717) at 96.3˚F CT, 20˚F SST, 78˚F EWB<br />

3


CXV-T<br />

The CXV-T is perfect for applications where size matters. The CXV-T’s superior<br />

performance, layout flexibility, and large capacity (645 - 1,888 R-717 tons) make this<br />

unit ideal for large tonnage projects. By employing <strong>BAC</strong>’s patented Advanced Coil<br />

and Combined Flow Technologies, these units provide value to both the installing<br />

contractor and the owner, providing the lowest energy consumption, lowest refrigerant<br />

charge, and lowest installation costs possible.<br />

Multi-cell CXV-T Installation Showing Simplified Piping<br />

4 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


Note: Do you have concerns for<br />

staying under the 10,000 lb NH 3<br />

PSM<br />

threshold? Consider the CXV-T.<br />

i n d u s t r y l e a d i n g p e r f o r m a n c e<br />

99Highest capacity per footprint in the industry<br />

9<br />

9 Patented Combined Flow Technology provides the highest capacity at<br />

the lowest refrigerant charge in the industry<br />

c o s t e f f e c t i v e i n s t a l l a t i o n<br />

99Dual air inlets allow for simple steel design and layout flexibility<br />

99Fewer coil connections save piping, welding, and valves<br />

99Flexibility of coil connection location simplifies piping<br />

99Low operating weight reduces crane and steel sizing<br />

99Single fan and motor reduces wiring and controls<br />

99Built-in alignment guides allow for fast rigging<br />

Modular Assembly<br />

s e r v i c e a b i l i t y<br />

99Spacious plenum with an optional dry internal walkway<br />

9<br />

99Oversized hinged access doors on each end wall<br />

99Motor removal davit system (optional)<br />

9 Extended lubrication lines and internal ladder (optional)<br />

D u r a b l e c o n s t r u c t i o n<br />

CXV-T with Full Sound Attenuation<br />

99Scale reducing technology increases system efficiency<br />

99Coils fabricated to ASME B31.5 standards<br />

99Durable materials of construction:<br />

• Hot-dip galvanized (G-235) steel construction standard<br />

• All stainless steel construction available<br />

Perimeter Handrails with Ladder<br />

P R O D U C T M A N U A L : E v a p o r a t i v e C o n d e n s e r s 5


CXVB<br />

Improving on an already successful product, <strong>BAC</strong> is proud to announce the CXVB.<br />

With 33% more capacity and an upgraded feature set, the CXVB, with its patented<br />

coil-fill technology sets the standard for heat rejection technology.<br />

A CXV Installation Showing Simplified Piping<br />

6 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


Note: Patented coil-fill technology only<br />

available from <strong>BAC</strong>.<br />

T E C H N O L O G Y — L E A D E R S H I P<br />

99Patented Combined Flow Technology provides the highest capacity at<br />

the lowest refrigerant charge in the industry<br />

99Air and water flow in a parallel path therefore eliminating scale<br />

producing “hot spots” on the coil<br />

99Increased heat rejection occurs as the water flows over the fill therefore<br />

lowering spray water temperatures<br />

99Meets wind and seismic requirements of the 2009 International<br />

Building Code through shake table testing. Rated to withstand a<br />

seismic event up to 2.4g<br />

99Premium efficient motors are standard and ready for VFD’s now or later<br />

Operating Charge<br />

Operating Charge<br />

CXV<br />

Others<br />

Others<br />

I N S T A L L A T I O N E F F I C I E N C Y<br />

99Coil-fill technology lowers installation and operating costs<br />

• Significantly lower refrigerant charge<br />

• Fewer coil connections and valves<br />

• Lower weights mean support steel can be reduced<br />

• Less overall piping connections and fewer supports<br />

99Pre-assembled platform package reduces installation time (optional)<br />

99Single point wiring simplifies field installation (optional)<br />

S E R V I C E — M A I N T E N A N C E<br />

Easily Accessible Spray Water Distribution<br />

99Oversized doors for access to the internal walkway<br />

9<br />

9 Spacious interior provides easy access to the cold water basin,<br />

drift eliminators, coils, and drive system<br />

99Extended lubrication lines, internal walkway, and ladder (standard)<br />

99A water distribution system that makes service of the nozzles,<br />

spray branches, and headers possible without the need for tools<br />

99Motor davit system to facilitate motor removal (optional)<br />

I N D U S T R I A L G R A D E C O N S T R U C T I O N<br />

99Materials of Construction:<br />

• Hot dip galvanized (G-235) steel construction standard<br />

• TriArmor ® Corrosion Protection System encapsulates the hygienic<br />

cold water basin with three barriers of protection (optional)<br />

99Fully welded, not bolted, stainless steel basins (optional)<br />

99All coils are fabricated to ASME B31.5 standards<br />

Pre-Assembled Platforms<br />

P R O D U C T M A N U A L : E v a p o r a t i v e C o n d e n s e r s 7


PC2<br />

The PC2 is <strong>BAC</strong>’s newest evaporative condenser, complementing and completing<br />

<strong>BAC</strong>’s already impressive array of products. The breadth of its tonnage range,<br />

41 – 2,506 ammonia tons, makes it an excellent choice for either replacement<br />

opportunities or new construction/expansion projects.<br />

PC2 During Shake Table Testing<br />

8 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


Note: Earthquake concerns?<br />

The PC2 has been shake table<br />

verified up to 3.75g.<br />

C O N F I D E N C E — R E L I A B I L I T Y<br />

99Meets wind and seismic requirements of the 2009 International<br />

Building Code through shake table testing<br />

99Bearings selected for a minimum life of L 10<br />

100,000 hours<br />

9<br />

9 Premium efficient motors are standard and ready for VFD’s now or later<br />

99Dual fan option is available on the popular 12’ x 18’ footprint –<br />

<strong>BAC</strong> exclusive!<br />

99Redundant pump option for peace of mind<br />

I N S T A L L A T I O N E F F I C I E N C Y<br />

Two Fans on 12’ x 18’ Footprints (Optional)<br />

99<strong>BAC</strong>’s InterLok System aligns the coil casing and the basin to<br />

expedite rigging<br />

9<br />

99Single piece lift for most units<br />

99Containerized units available<br />

99Footprints that mount on most existing steel supports<br />

99Single point wiring simplifies field installation (optional)<br />

9 Pre-assembled platform package reduces installation time (optional)<br />

S E R V I C E — M A I N T E N A N C E<br />

99Air inlet louvers are sectioned for easy removal and easy<br />

access to all basin components<br />

99External motor adjustment with included wrench<br />

99A water distribution system that makes service of the nozzles, spray<br />

branches, and headers possible without the need for tools<br />

99Quick release tooless strainer<br />

Single Piece Lift<br />

D u r a b l e C o n s t r u c t i o n<br />

99Materials of Construction:<br />

• Hot dip galvanized (G-235) steel construction standard<br />

• TriArmor ® Corrosion Protection System encapsulates the hygienic<br />

cold water basin with three barriers of protection (optional)<br />

99Fully welded, not bolted, stainless steel basins (optional)<br />

99All coils are fabricated to ASME B31.5 standards<br />

Pre-Assembled Platforms<br />

P R O D U C T M A N U A L : E v a p o r a t i v e C o n d e n s e r s 9


VCA<br />

When your application calls for a workhorse, turn to the VCA. The VCA incorporates<br />

features which benefit the installer, operator, end-user, and owner. With a tonnage<br />

range of 87 - 1,433 ammonia tons and compliance with the wind and seismic<br />

requirements of the 2009 International Building Code, the VCA is the industry leader in<br />

the forced draft, axial fan category.<br />

VCA During Installation<br />

10 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


Note: If access is a concern, the<br />

VCA has oversized doors as standard.<br />

P E A C E O F M I N D — F L E X I B I L I T Y<br />

99Independent fan motors are standard on every VCA model providing<br />

redundancy and options for capacity control<br />

• For replacement opportunities where existing wiring must remain,<br />

the VCA can be supplied with a dual motor option<br />

99Meets wind and seismic requirements of the 2009 International<br />

Building Code through shake table testing<br />

99Bearings selected for a minimum life of L 10<br />

94,000 hours<br />

99Premium efficient motors are standard and ready for VFD’s now or later<br />

I N S T A L L A T I O N E F F I C I E N C Y<br />

Shake Table Testing<br />

99<strong>BAC</strong>’s InterLok System aligns the coil casing and the basin to<br />

expedite rigging<br />

9<br />

99Single point wiring simplifies field installation (optional)<br />

9 Pre-assembled platform packages significantly reduce installation time<br />

S E R V I C E A B I L I T Y<br />

99Two large access doors are standard with every side blow VCA<br />

9<br />

9 Entire drive system is located at the base of the unit for easy and<br />

unrestricted access to the motors, bearings, and fans<br />

99Extended lubrication lines standard<br />

99A water distribution system that makes service of the nozzles, spray<br />

branches, and headers possible without the need for tools<br />

99Multiple access options to meet your service and site requirements<br />

(all OSHA compliant)<br />

Variety of Pre-Assembled Platforms<br />

I N D U S T R I A L G R A D E C O N S T R U C T I O N<br />

99Materials of Construction:<br />

• Hot dip galvanized (G-235) steel construction standard<br />

• TriArmor ® Corrosion Protection System encapsulates the hygienic<br />

cold water basin with three barriers of protection (optional)<br />

99Fully welded, not bolted, stainless steel basins (optional)<br />

99All coils are fabricated to ASME B31.5 standards<br />

Oversized Access Doors as Standard<br />

P R O D U C T M A N U A L : E v a p o r a t i v e C o n d e n s e r s 11


Series V<br />

The VC1, VCL, and VC1-C combine to complete <strong>BAC</strong>’s Series V product line.<br />

Together, they provide solutions to some of the hardest evaporative cooling scenarios.<br />

With both indoor and outdoor applications possible, the VCL also accommodates low<br />

height restrictions. The VC1-C is ideal for exporting, as it fits into standard shipping<br />

containers.<br />

VC1 Installation<br />

VCL Installation<br />

12 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


Note: The VC1 and VCL are great for tight<br />

enclosures and sound sensitive applications.<br />

E a s y M a i n t e n a n c e<br />

99<strong>BAC</strong> 360 TM Spray Nozzles are non-clogging, reducing maintenance<br />

costs and ensuring efficient equipment operation<br />

99Fans, motors, and drive system are located outside of the moist<br />

discharge air stream, protecting them from moisture, condensation,<br />

and icing while facilitating maintenance<br />

99All moving parts are located near the base of the unit, within easy<br />

reach for cleaning, lubrication, or adjustments<br />

F l e x i b l e I n s t a l l a t i o n<br />

External Drive Access<br />

99Low profile VCL fits well into mechanical equipment rooms with low<br />

ceilings and are easily hidden behind louvered walls on buildings<br />

9<br />

external duct work and other sources of external static pressure exist<br />

99VC1, VCL, and VC1-C can accommodate indoor applications<br />

9 Series V models have centrifugal fans, suitable for applications where<br />

E c o n o m i c a l E x p o r t<br />

99VC1-C models are sized specifically to fit into standard dry van<br />

containers, minimizing ocean freight costs for export shipments<br />

R e d u n d a n c y a n d R e l i a b i l i t y<br />

BALTIGUARD Fan System<br />

99Premium efficient/inverter duty motors are standard<br />

9<br />

9 Optional BALTIGUARD TM Fan System provides redundancy and energy<br />

savings by providing a pony motor<br />

L o w S o u n d<br />

99Centrifugal fans have inherently low sound characteristics<br />

9<br />

9 Factory designed sound attenuation is available for both the air intake<br />

and discharge<br />

99Particularly sound sensitive areas can be accommodated by facing the<br />

quiet blank-off panel to the sound sensitive direction<br />

VC1-C Containerized Units<br />

P R O D U C T M A N U A L : E v a p o r a t i v e C o n d e n s e r s 13


IBC<br />

<strong>BAC</strong> is a pioneer in the cooling industry, demonstrating product ruggedness and<br />

reliability through shake table testing by meeting the seismic and wind requirements<br />

of the 2009 International Building Code (IBC). <strong>BAC</strong> chooses to test their products in<br />

actual earthquake simulations. For our complete shake table testing story visit us at:<br />

www.BaltimoreAircoil.com/english/knowledge-center/multimedia<br />

S h a k e T a b l e T e s t i n g<br />

99It is the only way to guarantee functionality after an event.<br />

99Full-size units are tested by an independent laboratory<br />

in accordance with AC 156.<br />

99Tests are conducted on tri-axial shake tables.<br />

99Functional tests are conducted before and after testing to<br />

verify functionality and certify units for a component<br />

importance factor of 1.5.<br />

14 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


Export<br />

P C 2 a n d V C 1 - C , C o n t a i n e r i z e d f o r e x p o r t<br />

5 0 0 T o n s i n a s i n g l e 4 0 ’ S h i p p i n g C o n t a i n e r *<br />

E n g i n e e r e d f o r :<br />

99Lowest shipping costs for the worldwide<br />

export market<br />

99Maximized capacities for assembled<br />

containerized units<br />

99Designed to fit, assembled, in 20’<br />

and 40’ dry van containers<br />

• All VC1-C, PC2 7.4’ x 9’, and PC2 7.4’ x 18’ units are designed to fit assembled<br />

into dry van containers, minimizing ocean freight costs for export shipments.<br />

B A C q u a l i t y a n d f e a t u r e s a v a i l a b l e a n y w h e r e !<br />

Sequence for Removal and Rigging of a PC2 Containerized Unit<br />

* Nominal Tons (R-22) at 105˚F CT, 40˚F SST, 78˚F EWB<br />

P R O D U C T M A N U A L : E v a p o r a t i v e C o n d e n s e r s 15


Product Comparison<br />

I t e m s s h a d e d i n b l u e a r e B A C e x c l u s i v e f e a t u r e s a n d o p t i o n s<br />

Standard Features CXV-T CXVB PC2 [4] VCA VC1 VC1-C VCL<br />

Axial Fan • • • •<br />

Centrifugal Fan [1] • • •<br />

Large Plenum Area for Access • • •<br />

R-717 Tons 645 - 1,888 75 - 1,287 41 - 2,506 87 - 1,433 7 - 1,140 153 - 333 11 - 212<br />

R-22 Tons 816 - 2,390 105 - 1,815 58 - 3,530 122 - 2,019 10 - 1,608 216 - 469 16 - 299<br />

Shake Table Tested 2.4g 3.75g 1.6g<br />

Premium Efficient Fan Motors • • • • • • •<br />

Construction Options<br />

Welded Stainless Steel Cold Water Basin [3] • •<br />

Water-Contact Stainless Steel Cold Water Basin [3] • • • • • • •<br />

Stainless Steel Construction [3] • • • • • •<br />

Water-Contact Stainless Steel Unit • • • • • •<br />

EVERTOUGH Construction • •<br />

TriArmor ® Corrosion Protection System • • •<br />

Coil Options<br />

Extended Surface Coils • • • • • •<br />

Stainless Steel Coils • • • • • • •<br />

ASME "U" Stamp Coils • • • • • • •<br />

Multiple Circuit Coils • • • • • • •<br />

Options and Accessories<br />

Independent Fan Operation • • •<br />

BALTIGUARD Fan System • • • •<br />

Low Sound Fan • • •<br />

Whisper Quiet Fans<br />

•<br />

Intake Sound Attenuation • • • •<br />

Discharge Sound Attenuation • • • •<br />

Handrails with Ladder [2] • • •<br />

External Access Platform with Ladder [2] • • • • •<br />

Internal Ladder • •<br />

Internal Access Platform • •<br />

Gear Drive<br />

Basinless Unit Construction<br />

•<br />

•<br />

Indoor Applications • • •<br />

Motor Removal System • • •<br />

Single Point Wiring • • •<br />

Redundant Pumps • • •<br />

Top Combined Inlet Shields<br />

•<br />

Note 1: Centrifugal fan units can overcome ESP imposed by duct work or other restrictions. A larger<br />

fan motor may be required. Contact your local <strong>BAC</strong> Representative with any questions.<br />

Note 2: Safety cages available on ladders when required by local safety standards.<br />

Note 3: Seams between the panels inside the cold water basin are welded for CXV, CXV-T, and VCA models.<br />

The basin is leak tested at the factory and welded seams are provided with a five-year leak-proof warranty.<br />

Note 4: Some materials of construction options and accessories were not available during the time of printing.<br />

Contact your local <strong>BAC</strong> Representative for the most current information.<br />

16 Q u e s t i o n s ? C a l l 4 1 0 . 7 9 9 . 6 2 0 0 o r v i s i t W W W . B A L T I M O R E A I R C O I L . C O M


<strong>Evaporative</strong><br />

Condenser Solutions?<br />

V i s i t w w w . B a l t i m o r e A i r c o i l . c o m :<br />

Select a Unit<br />

Request a Quote<br />

Find Your Local Representative<br />

Browse <strong>BAC</strong>’s Knowledge Center<br />

Learn About Parts & Services


BALTIMORE<br />

AIRCOIL COMPANY<br />

COOLING TOWERS<br />

CLOSED CIRCUIT COOLING TOWERS<br />

ICE THERMAL STORAGE<br />

EVAPORATIVE CONDENSERS<br />

HYBRID PRODUCTS<br />

PARTS & SERVICES<br />

w w w . B a l t i m o r e A i r c o i l . c o m<br />

7600 Dorsey Run Road, Jessup, MD 20794 › Telephone: (410) 799-6200 › Fax: (410) 799-6416

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!