The Jumbo rear panel includes:<br />
• (12A/B) Triple track power terminals (all output same voltage)<br />
• (13) Remote control connector<br />
• (14) Emergency stop terminals<br />
• (15) Brake terminals<br />
• (16A) Forward terminals<br />
• (16B) Reverse terminals<br />
• (17) Timer terminals<br />
Any simple contact—like a 17100 track contact or a simple switch—can<br />
be connected to the function terminals (14 through 17) to control any of<br />
the special functions.<br />
The operating capabilities, both manual and automatic, of the Jumbo are<br />
quite numerous. Here are some basic examples:<br />
• Train mass simulation<br />
For this "momentum" simulation, set the drive voltage control (1) to “3”.<br />
Press the Emergency Stop key (4). Set the acceleration control (5) to a<br />
middle position, for example, to “3”.<br />
If you now press a direction key (2A or 2B), you will see that the voltage<br />
does not increase quickly, but quite slowly. The locomotive also starts<br />
moving slowly, just like it does on a real train with a heavy load.<br />
If you turn the control (5) to higher numbers the voltage will increase at a<br />
slower rate. Once the train reaches the speed set with the drive voltage<br />
control, you can bring it to a stop using either the Brake (3) or Emergency<br />
Stop (4) touch key.<br />
The acceleration setting is also in effect when you use the drive voltage<br />
control (1). When you turn the control quickly to a high setting, for<br />
example, to “6”, the voltage increases slowly, according to the pre-set<br />
acceleration rate.<br />
• Automatic slow track<br />
When the train passes over the 17100 track contact (see Page 111), the<br />
timer function of the Jumbo is activated. The train slows according to the<br />
deceleration setting and is held at the minimum drive voltage setting until<br />
the selected timed period is complete. Then the<br />
train accelerates according to the acceleration<br />
setting until the speed reaches the maximum drive<br />
voltage setting.<br />
This circuit can also be used to automatically slow<br />
trains on downhill grades.<br />