29.10.2012 Views

00559 Interim PDF Edition - Champex-Linden

00559 Interim PDF Edition - Champex-Linden

00559 Interim PDF Edition - Champex-Linden

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Jumbo<br />

at<br />

Work<br />

0 10 20 30<br />

V<br />

4 6<br />

2 8<br />

0<br />

10<br />

A<br />

A 12 B<br />

+ 0-24V -<br />

Eingang: 230V~ 50Hz<br />

Ausgang: 22Veff 160VA<br />

TRANSFORMATOR<br />

IP20<br />

IP40<br />

13<br />

Vor Anschluss der<br />

Fernbedienung<br />

Brücke zwischen<br />

den Buchsen<br />

entfernen<br />

14 15 A 16 B 17<br />

Bedienungsanleitung<br />

Sicherheitshinweise beachten<br />

MADE IN GERMANY by STEGER<br />

Art.Nr. 31-002 SER.-Nr. 93.10.1500<br />

The Jumbo rear panel includes:<br />

• (12A/B) Triple track power terminals (all output same voltage)<br />

• (13) Remote control connector<br />

• (14) Emergency stop terminals<br />

• (15) Brake terminals<br />

• (16A) Forward terminals<br />

• (16B) Reverse terminals<br />

• (17) Timer terminals<br />

Any simple contact—like a 17100 track contact or a simple switch—can<br />

be connected to the function terminals (14 through 17) to control any of<br />

the special functions.<br />

The operating capabilities, both manual and automatic, of the Jumbo are<br />

quite numerous. Here are some basic examples:<br />

• Train mass simulation<br />

For this "momentum" simulation, set the drive voltage control (1) to “3”.<br />

Press the Emergency Stop key (4). Set the acceleration control (5) to a<br />

middle position, for example, to “3”.<br />

If you now press a direction key (2A or 2B), you will see that the voltage<br />

does not increase quickly, but quite slowly. The locomotive also starts<br />

moving slowly, just like it does on a real train with a heavy load.<br />

If you turn the control (5) to higher numbers the voltage will increase at a<br />

slower rate. Once the train reaches the speed set with the drive voltage<br />

control, you can bring it to a stop using either the Brake (3) or Emergency<br />

Stop (4) touch key.<br />

The acceleration setting is also in effect when you use the drive voltage<br />

control (1). When you turn the control quickly to a high setting, for<br />

example, to “6”, the voltage increases slowly, according to the pre-set<br />

acceleration rate.<br />

• Automatic slow track<br />

When the train passes over the 17100 track contact (see Page 111), the<br />

timer function of the Jumbo is activated. The train slows according to the<br />

deceleration setting and is held at the minimum drive voltage setting until<br />

the selected timed period is complete. Then the<br />

train accelerates according to the acceleration<br />

setting until the speed reaches the maximum drive<br />

voltage setting.<br />

This circuit can also be used to automatically slow<br />

trains on downhill grades.<br />

89

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!