Introduction<br />
Welcome to the First Edition of Tyco Safety <strong>Product</strong>s’ C•<strong>CURE</strong> Control <strong>Catalogue</strong> for product available from our Letchworth UK<br />
Distribution Centre. We aim to make your product range as comprehensive as possible to ensure you never need go anywhere<br />
else. To meet this goal, our product specialists, with your help, have selected the most appropriate, cost effective product range.<br />
Please note that not all of the C•<strong>CURE</strong> <strong>Product</strong> range is stock coded/held at Letchworth or listed in ADT’s S & I documents.<br />
In line with our ISO 9000 accreditation, only those products that meet the highest quality criteria have been included.<br />
We have also included certain parts that are available from software house but not held in the U.K.<br />
Our warehouse is one of the largest Fire & Security product distribution centres in<br />
Europe. Our goal is to despatch product on the same day as we receive your<br />
order. Our warranty and service returns policy is second to none. We recognise<br />
that your business is highly dependant on excellence in customer service and to<br />
help achieve this we offer extended warranty from many of our suppliers. Full<br />
credit is also available on a “No Question – No Fuss” basis for any new inwarranty<br />
product returned to the distribution centre.<br />
Our training department offers comprehensive sales, design and engineering training on our<br />
complete range of products. We recommend you take advantage of this free of charge<br />
service. As always, training can be undertaken any time, anywhere to suit your business<br />
needs. Contact our telephone Help Line for further information.<br />
Tyco Safety <strong>Product</strong>s’ Web site contains an endless supply of product related<br />
information. It is regularly updated and features many aids to the selling process<br />
including presentation material, independent product test results and detailed<br />
technical information.<br />
Our web site can be found at www.tycosafetyproducts-europe.com.<br />
To enhance customer specifications and quotations we also provide a series of product<br />
datasheets which can give our clients an opportunity to read more about the product.<br />
We are positive that together we can help grow your business and we look forward to<br />
working with you in the future.<br />
For further details on this catalogue, contact our customer telephone Help Line<br />
on 01932 743 327.<br />
1
Table Of Contents<br />
CONTENT<br />
C•<strong>CURE</strong> 800<br />
3<br />
6<br />
7<br />
8<br />
9<br />
Index Intro<br />
PC Hardware<br />
Core Systems<br />
Software Upgrade<br />
Redundant Systems<br />
11<br />
20<br />
22<br />
26<br />
31<br />
34<br />
37<br />
38<br />
47<br />
48<br />
50<br />
52<br />
56<br />
58<br />
59<br />
Software Options<br />
C•<strong>CURE</strong> Central<br />
ID Badging<br />
I Star<br />
apC®/8X<br />
apc Lite<br />
Power Supplies<br />
Cards & Readers<br />
Card Buraeu<br />
Locks<br />
Ancillaries<br />
Post SalesSupport and Training<br />
BSIA Information<br />
CAD Symbols<br />
Glossary of Terms<br />
2
C•<strong>CURE</strong> 800 Integrated Security Management System<br />
C•<strong>CURE</strong> 800<br />
Introduction<br />
C•<strong>CURE</strong> is a scalable, single platform security management<br />
solution that enables seamless integration of various<br />
technologies including RFID Asset Management, CCTV<br />
Monitoring, Paging and Photo Imaging management.<br />
The C•<strong>CURE</strong> 800 utilised the Microsoft ® Windows ® NT/2000<br />
32- Bit operating system which allows running multiple<br />
applications simultaneously and sharing information with other<br />
systems over an enterprise-wide network<br />
C•<strong>CURE</strong> 800 utilises a Windows Graphical User Interface (GUI)<br />
allowing intuitive navigation among interactive applications<br />
modules. The Windows operating system provides numerous<br />
performance advantages such as use of industry standard<br />
computer hardware and communications devices, true real time<br />
and multi-user, multi-tasking operating system designed to run<br />
multiple applications simultaneously without compromising the<br />
security monitoring environment. Open platform with full<br />
connectivity to standard network topologies and a highly<br />
secure operating environment. At the core of the C•<strong>CURE</strong> 800<br />
is a powerful, 4GL relational database engine providing<br />
maximum flexibility in data storage, manipulation and retrieval.<br />
This makes the C•<strong>CURE</strong> 800 a powerful security information<br />
management tool.<br />
C•<strong>CURE</strong> 8000 represents a major extension to the C•<strong>CURE</strong><br />
platform by introducing the next generation in a scalable,<br />
security management solution for large installations. It<br />
seamlessly integrates numerous applications including access<br />
control and alarm monitoring, email, embedded broadcast<br />
paging, RFID asset tracking, Digital and CCTV, elevator control<br />
and photo imaging. The C•<strong>CURE</strong> 800 platform provides<br />
interoperability with third party applications and systems<br />
through open database connectivity (ODBC) links. The optional<br />
Bi-directional Serial Interface, and licensed application<br />
programming interface (API) C•<strong>CURE</strong> 8000’s Graphical User<br />
Interface (GUI) allows intuitive navigation among interactive<br />
application modules.<br />
The Windows NT/2000 operating system provides performance<br />
advantages such as the use of industry standard computer<br />
hardware and communication devices, true real-time, multi-user,<br />
multi-tasking operating system with full connectivity to standard<br />
network topologies and highly secure<br />
operating environment. Please note that<br />
Windows95 and Windows 98 are no longer<br />
supported by C•<strong>CURE</strong> 800 or C•<strong>CURE</strong><br />
8000.<br />
Note: It is recommended that customers use the most<br />
current firmware release for each panel and software<br />
release. The latest versions are backward compatible<br />
with the software versions listed.<br />
C•Cure 800/8000 is a scalable security management solution suitable for large and small installation alike. With its open<br />
architecture, it seamlessly integrates numerous applications.<br />
Features<br />
• Global/local anti-passback<br />
• Massaging to WAP phones<br />
• CCTV<br />
• Remote administration and monitoring<br />
• Access control and alarm monitoring<br />
• Email & paging<br />
• Elevator control<br />
• Guard Tours<br />
• Escort Management<br />
Enhancements<br />
• Integrated digital video<br />
• ERP System integration<br />
• Management (AC, heat, etc)<br />
• Visitor Management<br />
3
C•<strong>CURE</strong> 800/8000 Configuration Matrix<br />
8000 8000 Plus<br />
Model Model Model Model Model Model Enterprise Enterprise<br />
1 5 10 20 30 40 Server Server<br />
C•<strong>CURE</strong> 800<br />
No. of Online Readers 32 64 128 256 512 1000 2500 *<br />
No. of Online Inputs 128 256 512 1024 2500 5000 10000 *<br />
No. of Online Outputs 128 256 512 1024 2500 5000 10000 *<br />
No. of addressable controllers No limit* No limit* No limit* No limit* No limit* No limit* No limit* No limit*<br />
(dial-up or network)<br />
No. of Cardholders 10K 40K 40K 250k 250k 250k 500k 500k<br />
No. of Assets 10K 40K 40Kk 250K 250K 250K 500K 500K<br />
No. of Simultaneous Client 2 3 4 8 16 64 128 128<br />
PCs included with server<br />
No. of Client PCs definable 999 999 999 999 999 999 999 999<br />
on server<br />
Image/Capture & Display YES YES YES YES YES YES YES YES<br />
Sentinel Required YES YES YES YES YES YES YES YES<br />
C•<strong>CURE</strong> ID Badging Client Optional Optional Optional Optional Optional Optional Optional Optional<br />
Vision Badging Client No Optional Optional Optional Optional Optional Optional Optional<br />
VisionOne Optional Optional Optional Optional Optional Optional Optional Optional<br />
Unlimited E-mail recipient YES YES YES YES YES YES YES YES<br />
Paging-Single Subscriber YES YES YES YES YES YES YES YES<br />
Unlimited Paging recipients Optional Optional Optional Optional Optional Optional YES YES<br />
iSTAR Intrusion Zones/Keypad Optional YES YES YES YES YES YES YES<br />
Commands<br />
Guard tour Optional Optional Optional Optional Optional Optional Optional Optional<br />
Central Monitoring Optional Optional Optional Optional Optional Optional Optional Optional<br />
Bi-Directional Serial interface Optional Optional Optional Optional Optional Optional Optional Optional<br />
with Stentofon Intercom<br />
Bi-Directional Serial Interface Optional Optional Optional Optional Optional Optional Optional Optional<br />
with Radionics Receivers<br />
Bi-directional Serial Interface Optional Optional Optional Optional Optional Optional Optional Optional<br />
C•<strong>CURE</strong> NetVue Software Optional Optional Optional Optional Optional Optional Optional Optional<br />
Asset management software Optional Optional Optional Optional Optional Optional Optional Optional<br />
C•<strong>CURE</strong> Central replication Optional Optional Optional Optional Optional Optional Optional Optional<br />
option<br />
Enhanced Reporting Optional YES YES YES YES YES YES YES<br />
Area Lockout Optional Optional Optional Optional Optional Optional Optional Optional<br />
N-man Rule and Occupancy YES YES YES YES YES YES YES YES<br />
Wild Card in search YES YES YES YES YES YES YES YES<br />
Expiring Clearances YES YES YES YES YES YES YES YES<br />
Enhanced Password Protection 3 YES YES YES YES YES YES YES YES<br />
NEW FOR C•<strong>CURE</strong> 800 version 8.1<br />
Field Audit Trail of personnel data YES YES YES YES YES YES YES YES<br />
Advanced Door Monitoring Optional Optional Optional Optional Optional Optional Optional Optional<br />
Muster/De-muster YES YES YES YES YES YES YES YES<br />
Carpool anti-passback Optional Optional Optional Optional Optional Optional Optional Optional<br />
Cardhold Access Events YES YES YES YES YES YES YES YES<br />
Bi-Directional Serial interface<br />
with Inovonics Optional Optional Optional Optional Optional Optional Optional Optiona<br />
NEW FOR iSTAR version 3.0<br />
DHCP support on iSTAR YES YES YES YES YES YES YES YES<br />
Dual Network support on iSTAR YES YES YES YES YES YES YES YES<br />
C•<strong>CURE</strong> 800/8000 is designed for unlimited expansion. The often-stated 3,000 reader and 32,000 input/output<br />
handling are testing limits only and do not represent expansion restrictions. System performance will vary depending upon<br />
specific hardware configuration including a number of communication lines/ports, download/upload frequency, etc.<br />
Note: The enhanced password protection feature is a no-charge feature but must be ordered as a licensed option to the C•<strong>CURE</strong>800.<br />
4
Software : Firmware Table<br />
C•<strong>CURE</strong> 800/8000 apC apC/L apC/L apC/8X apC/8X iSTAR<br />
Version Flash Flash Version<br />
V.3.20 7.4Y 10.4Y 10.4Y 8.4Y 8.4Y NA<br />
V3X with dialup 7.7F 10.7F 10.7F 8.7F 8.7F NA<br />
C•<strong>CURE</strong> 800<br />
V3.x with RM LCD<br />
Messages<br />
7.7F 10.7F 10.7F 8.7F 8.7F NA<br />
V3.X with<br />
elevators<br />
7.7F 10.7F 10.7F 8.7F 8.7F NA<br />
V4.X 7.7F 10.7F 10.7F 8.7F 8.7F NA<br />
V5.0 7.7F 10.7F 10.7F 8.7F 8.7F 1.2<br />
V5.1.1 7.7H 1 10.7H 1 10/7H 1 8.7H 1 8.7H 1 1.2.1 2<br />
V5.2.0 7.7H 10.7H 10.7H 8.7H 8.7H 1.3.0<br />
V6.0.1 7.7H 10.7H 10.7H 8.7H 8.7H 1.3.0<br />
V7.0.1 7.7M 10.7M 10.7M 8.7M 8.7M 2.0<br />
V7.1.0 7.7N 10.7N 10.7N 8.7M 8.7N 2.1<br />
V7.2.0 7.7P 10.7P 10.7P 8.7P 8.7P 2.2<br />
V8.0 7.7R 10.7R 10.7R 8.7R 8.R 3.0<br />
V8.1 7.75 10.75 10.78 8.75 8.75 3.1<br />
5
C•<strong>CURE</strong> 800/8000 Minimum Hardware and Software Requirements<br />
C•<strong>CURE</strong> 800/8000 Server WITHOUT Enhancing Reporting Option<br />
C•<strong>CURE</strong> 800<br />
Processor<br />
Model Number 1 and 5<br />
400 MHz Intel Pentium III or higher<br />
Model Number 10 and 20<br />
600 MHz Intel Pentium III or higher<br />
Model Number 30 and 40<br />
1.10 GHzIntel Pentium III or higher<br />
Model 8000 and 8000 Plus<br />
1.5 GHz Intel Pentium III or higher<br />
Free Hard Disk Space<br />
2.0 GB<br />
Memory<br />
Model Numbers 1 through 20<br />
256 MB RAM<br />
Model Numbers 30 through 8000 plus 512 MB RAM<br />
C•<strong>CURE</strong> 800/8000 Server WITH Enhancing Reporting Option<br />
Processor<br />
Model Number 1 and 5<br />
600 MHz Intel Pentium III or higher<br />
Model Number 10 and 20<br />
1.0 GHz Intel Pentium III or higher<br />
Model Number 30 and 40<br />
1.5 GHz Intel Pentium III or higher<br />
Model 8000 and 8000 Plus<br />
2.0 GHz Intel Pentium III or higher<br />
Free Hard Disk Space<br />
Memory<br />
Model Numbers 1 through 40<br />
Model 8000 and 8000 Plus<br />
3.0GB<br />
512MB RAM<br />
1 GB RAM<br />
Network Card<br />
10bT<br />
CD-ROM Drive<br />
10X<br />
Monitor/Video Adaptor board 17” SVGA (1024 x768)<br />
Operating System<br />
Windows® 2000 Professional, Windows 4.0 (Service Pack 5), XP<br />
Mouse<br />
PS/2 bus type<br />
Ports<br />
2 serial, 1 parallel<br />
Modem<br />
56.6 KBPS<br />
*Windows 2000 Professional or Server requires more memory and hard disk space than Windows NT, which should be taken into consideration when specifying minimum hardware<br />
requirements. C•<strong>CURE</strong> 800 servers to be connected to C•<strong>CURE</strong> Central have additional requirements. See page 36 for details.<br />
With today’s pace of technology, Software House must continue to dedicate resources to meeting today’s requirements, and<br />
the future needs of the worldwide market. As a robust security application, C•<strong>CURE</strong> 800 leverages the important features<br />
that can only be found with Windows NT or Windows 2000. Therefore, Windows 95 is no longer supported with C•<strong>CURE</strong><br />
800/8000 v8.0. We will continue to support MS Windows NT Workstation and MS Windows 2000 Professional as the primary<br />
client only platforms.<br />
Dell GX270 PC<br />
Tyco Safety <strong>Product</strong>s can supply a Del GX270C to the following specification under part number 636.006.067:-<br />
Dell GX270PC<br />
Intel Pentium 4 2.26GHz/533MHz front<br />
side bus, 512K advanced transfer cache.<br />
Microsoft Windows® 2000 Professional<br />
SP3<br />
Small Mini Tower (SMT) Chassis<br />
512NB RAM<br />
40GB IDE Hard Drive<br />
48x/24x CD-RW Read 512Mb RAM Write<br />
drive<br />
On-board speaker<br />
Dimensions<br />
Vertical: 7.1” width x 17.6” depth x 16.7”<br />
height<br />
Horizontal: 16.7” width x 17.6” depth<br />
x 7.1” height<br />
I/O Ports<br />
8 USB 2.0 ports (2 front, 6 back)<br />
2 serial port<br />
1 parallel port<br />
2 PS/2 ports, keyboard and mouse<br />
Microphone, stereo in, stereo out (back)<br />
& stereo out (front)<br />
1 RJ45 Network port<br />
Drive Bays<br />
Two internal 1” hard drive<br />
Two external 3.5”<br />
Two external 5.25”<br />
Power Supply<br />
GX270: 250 watts<br />
Expansion Slots<br />
Four PCI Slots: three 4.2” x 11” and one<br />
4.2” by 9”. One full height 8XAGP slot
C•<strong>CURE</strong> 800 Software Only<br />
C•<strong>CURE</strong> 800 Core System<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
Description<br />
CC800-1S-NV C•<strong>CURE</strong> 800 Model 1 System Software Only 1 Includes server<br />
software and 2 C•<strong>CURE</strong> Client licenses. No badging included.<br />
CC800-1ID<br />
C•<strong>CURE</strong> 800 Model 1 System Software Only 1. Includes server<br />
software and 2 C•<strong>CURE</strong> client licenses. C•<strong>CURE</strong> ID badging soft<br />
ware license included.<br />
CC800-1S<br />
Special C•<strong>CURE</strong> 800 Model 1 System Software Only - includes<br />
server software and 2 C•<strong>CURE</strong> client licenses. VisionOne license<br />
included (image capture/display/import, single-sided badge<br />
printing, and 3 badge layouts).<br />
CC800-5S<br />
C•<strong>CURE</strong> 800 Model 5 System Software Only - includes servers soft<br />
ware and 3 C•<strong>CURE</strong> client licenses<br />
CC800-10S<br />
C•<strong>CURE</strong> 800 Model 10 System Software Only - includes server soft<br />
ware and 4 C•<strong>CURE</strong> client licenses<br />
CC800-20S<br />
C•<strong>CURE</strong> 800 Model 20 System Software Only - includes server soft<br />
ware and 9 C•<strong>CURE</strong> client licenses<br />
CC800-30S<br />
C•<strong>CURE</strong> 800 Model 30 System Software only - includes server soft<br />
ware and 16 C•<strong>CURE</strong> client licenses<br />
CC800-40S<br />
C•<strong>CURE</strong> 800 Model 40 System Software Only- includes server soft<br />
ware and 64 C•<strong>CURE</strong> client licenses<br />
CC800ESS-S<br />
C•<strong>CURE</strong> 800 Model Enterprise System Software Only - includes<br />
server software and 128 C•<strong>CURE</strong> client licenses and Broadcast<br />
Messenger software<br />
CC800ES PLUS - S<br />
C•<strong>CURE</strong> 800 Model Enterprise Plus System Software Only<br />
includes server software and 128 C•<strong>CURE</strong> client licenses and<br />
Broadcast Messenger software, and enhanced reader capability.<br />
IMPORTANT NOTE: One set of English language manuals is provided with each application. The Getting Started Guide and Installation Guide,<br />
in English language manuals is provided with each application. The Getting Started and Installation Guide, in English language, are supplied<br />
on the application software CD.<br />
7
Software Model Upgrades<br />
Software Model Information Chart<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
Description<br />
CC800-1-5-SU-NV Upgrade Model 1 System Software to Model 5 5<br />
(VisionOne license not renewed). Includes new license only - system<br />
serial number required at time of order<br />
CC800-1-5-SU Upgrade Model 1 System Software to Model 5 5<br />
(VisionOne license renewed). Includes new license only - system<br />
serial number required at time of order<br />
CC800-1-5-SU-FV Upgrade Model 1 System Software to Model 5 5<br />
(also includes an upgrade form Vision One to the complete Vision<br />
package CC800-VSS). Includes new license only - system serial<br />
number required at time of order.<br />
CC800-1-5-SU-ID Upgrade Model 1 System Software to Model 5 5<br />
(Includes an upgrade from Vision One to the C•<strong>CURE</strong> ID Badging<br />
package CC800-IDS) Includes new license only.<br />
CC800-1-10-SUNV<br />
Upgrade Model 1 System Software to Model 10 5 (Vision One license<br />
not renewed). Includes new license only.<br />
CC800-1-10-SUFV<br />
Upgrade Model 1 System Software to Model 10 5 (Includes an<br />
Upgrade from VisionOne to the complete Vision package CC800-<br />
CC800-1-10-SU<br />
CC800-1-10-SU-ID<br />
CC800-5-10-U<br />
VSS). Includes new license only.<br />
Upgrade Model 1 System Software to Model 10 5 (VisionOne license<br />
renewed). Includes new license only.<br />
Upgrade Model 1 System Software to Model 10 5 (Includes an<br />
upgrade from VisionOne to the C•<strong>CURE</strong> ID badging package<br />
CC800-IDS). Includes new license only.<br />
Upgrade Model 5 System Software to Model 10 5 Includes<br />
new license only - system serial number required at time of order.<br />
CC800-5-20-SU Upgrade Model 5 System Software to Model 20 5 Includes<br />
CC800-5-30-SU<br />
CC800-50-40-SU<br />
CC800-10-20-SU<br />
new license only - system serial number required at time of order<br />
Upgrade Model 5 System Software to Model 30 5 Includes new license<br />
only - system serial number required at time of order.<br />
Upgrade Model 5 System Software to Model 40 5 Includes<br />
new license only - system serial number required at time of order<br />
Upgrade Model 10 Server System to Model 20 5 Includes new license<br />
only - system serial number required at time of order .<br />
CC800-10-30-SU Upgrade Model 10 System Software to Model 30 5<br />
CC800-10-40-SU<br />
CC800-20-30-SU<br />
CC800 -20-40-SU<br />
CC800-30-40-SU<br />
CC800-40-8000-SU<br />
CC800-502000LIC<br />
CC800020-2000LIC<br />
Includes new license only - system serial number required at time of order.<br />
Upgrade Model 10 System Software to Model 40 5 Includes<br />
new license only - system serial number required at time of order.<br />
Upgrade Model 20 System Software to Model 30 5 Includes<br />
new license only.<br />
Upgraded Model 20 System Software to Model 40 5 Includes<br />
new license only - system serial number required at time of order.<br />
Upgrade Model 30 System Software to Model 40 5 Includes<br />
new license only -s system serial number required at time of order.<br />
Upgrade Model 40 System Software4r to C-Cure8000 5 includes<br />
new license only - system serial number required at time of order.<br />
C-Cure 800 Model 30 System Software Only 5 - includes server soft<br />
ware and 16 C-Cure licenses<br />
Additional 20 Windows 2000 server client access licenses<br />
5<br />
C•<strong>CURE</strong> product certification required. Does not include on-site installation support. Training requisites must be met prior to purchases.<br />
Upgrade charge covers software only.<br />
8
C•Cure 800/8000 Redundant Systems<br />
C•<strong>CURE</strong> 800<br />
C•<strong>CURE</strong> 800 can optionally be configured to support a highavailability<br />
clustering solution for Windows 2000 and their<br />
applications. This ‘redundant’ solution is achieved by enabling<br />
two fully functioning Windows 2000 servers to act as hot<br />
spares for each other in the event of a server failure. Should a<br />
server fail, applications/services, data and users form the failed<br />
server are all migrated to the mirrored server.<br />
A redundant system requires a considerable amount of disk<br />
space, memory and RAM. Significantly more complex than<br />
simply ‘doubling’ the standard system, the redundant system<br />
is an extremely high-end system with the following<br />
specifications<br />
Typical Redundant System PC Specification<br />
Redundant Standard C•<strong>CURE</strong> 800<br />
Systems<br />
Server<br />
(minimum requirements)<br />
Servers provided 2 high end servers 1 desktop<br />
Minimum RAM 512MB 256MB<br />
Minimum Hard Disk 18 GB 10GB<br />
. Space<br />
Minimum Processor Pentium IV 2.2 GHz Pentium IV minimum 2.2 GHz<br />
High speed fail over Yes No<br />
. support<br />
A single, redundant sample system includes:<br />
2 High End Servers<br />
Minimum RAM<br />
Minimum Hard Disk<br />
Minimum Processor<br />
Operating System<br />
CD-ROM<br />
Backup Device<br />
Warranty on CPU Hardware<br />
Network<br />
Failover Software<br />
RAID (on-board)*<br />
Dell 2600 series<br />
512 MB<br />
18 GB<br />
Pentium IV, 2.2 GHz or Xeon 1.4 GHz<br />
Windows 2000 Server<br />
24X minimum<br />
Tape or CDRW<br />
From Dell, 3 years, Next Business Day<br />
Legato’s Co-Standby Server 2000<br />
RAID 0 on Drive 0<br />
RAID 5 on Drives 1,2,3<br />
Application Package:<br />
Co-Standby Server by Legato registration/software<br />
C•<strong>CURE</strong> 800/8000 software and redundant license<br />
Sentinel (software key)<br />
*RAID (Redundant Array of Independent Disks) previously an option are now standard on all bundled redundant systems.<br />
NOTE: All dealers must complete training on redundant systems prior to purchasing. Please contact our Training Department for more information.<br />
9
C•<strong>CURE</strong> 800 Redundant Systems<br />
Software Only Redundant Security Management System<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
CC800-20RDS<br />
CC800-30RDS<br />
CC800-40RDS<br />
CC8000ES-RDS<br />
CC8000ESPLUS-RDS<br />
Description<br />
C•<strong>CURE</strong> 800 Model 20 Redundant System Software Only<br />
(2 copies) Includes server software, 8 C•<strong>CURE</strong>4 Client licenses each.<br />
Requires CC8-VIN2K for redundancy (purchased separately).<br />
C•<strong>CURE</strong> 800 Model 30 Redundant SYstem Software Only<br />
(2 copies) Includes servers software 16C•<strong>CURE</strong> Client licenses each. Requires CC8-VIN2K for<br />
redundancy (purchased separately)<br />
C•<strong>CURE</strong> 800 Model 40 Redundancy System Software Only<br />
(2 copies) Includes server software, 64 C•<strong>CURE</strong>Client licenses each. Requires CC8VIN2K for<br />
redundancy purchased Separately)<br />
C•<strong>CURE</strong> 8000 Enterprise Redundancy System Software Only<br />
(2 copies) Incudes server software, 128 C•<strong>CURE</strong>Client licenses each and Broadcast Messenger<br />
Software. Requires CC*-VIN2K for redundancy (purchased separately)<br />
C•<strong>CURE</strong> 8000 Enterprise PLUS Redundant System Software Only<br />
(2 copies) Includes server software, 128 C•<strong>CURE</strong> Client licenses each, and Broadcast<br />
Messenger Software and enhanced reader capacity. Requires CC9-VIN2K for redundancy<br />
(purchased separately)<br />
Redundant Security Management Systems Upgrades *<br />
Model Number<br />
CC800-20RDS-UPG<br />
CC800-30RDS-UPG<br />
CC800-40RDS-UPG<br />
CC8000ES-RDS-UPG<br />
CC8000PL-RDS-UPG<br />
CC8-VIN2K<br />
CC800-XTAPE<br />
Description<br />
Upgrade an existing C•<strong>CURE</strong> 800 Model 20 System to a Redundant<br />
System Software Only Includes license and the second sentinel.<br />
Requires CC8-VIN2K for redundancy (purchased separately.)<br />
Upgrade an existing C•<strong>CURE</strong> 800 Model 30 System to a Redundant<br />
System Software Only. Includes license and the second sentinel.<br />
Requires CC8-VIN2K for redundancy (purchased separately.)<br />
Upgrade an existing C•<strong>CURE</strong> 800 Model 40 System to a Redundant<br />
System Software Only. Includes license and the second sentinel.<br />
Requires CC8-VIN2K for redundancy (purchased separately.)<br />
Upgrade an existing C•<strong>CURE</strong> 8000 Enterprise System to a<br />
Redundant System Software Only. Includes license and the second<br />
sentinel and Broadcast Messenger license. Requires CC8VIN2K for redundancy (purchased<br />
separately).<br />
Upgrade an existing C•<strong>CURE</strong>8000 PLUS Enterprise System to a<br />
Redundant System Software Only. Includes license and the second sentinel and a<br />
Broadcast Messenger license. Requires CC*-VIN2K for redundancy (purchased separately.)<br />
Hot redundancy software (Co-StandbyServer) to achieve redundancy on<br />
Windows 2000 Servers<br />
DDT4, External tape Backup Controller/Cables<br />
*<br />
All redundant systems (bundled, upgrades, and software only) are shipped with the required license patch turning the redundant option on.<br />
10
C•<strong>CURE</strong> 800 Software Enhancement Upgrades for Model 1<br />
Keypad Commands/Enhanced Intrusion Zones on iSTAR<br />
The Keypad Commands/Enhanced Intrusion Zones optional allows a C•<strong>CURE</strong> 800 Model 1 customer to add this advanced<br />
iSTAR based feature set to the base C•<strong>CURE</strong>800 configuration<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
CC800-IZKP<br />
iSTAR<br />
Description<br />
C•<strong>CURE</strong> 800 Keypad Commands/Enhanced Intrusion Zones for<br />
Includes licensing to enable the use of keypad commands and enhanced intrusion zone functionality<br />
with the iSTAR Intelligent Network Controller on a C•<strong>CURE</strong> 800 Model 1 configuration. System serial<br />
number, fax number and contact name are required at time of order.<br />
Enhanced Reporting<br />
The Enhanced Reporting option allows a C•<strong>CURE</strong> 800 Model 1 customer to add the functionality of increased report<br />
generation and formatting to the base C•<strong>CURE</strong> 800 configuration.<br />
Model Number<br />
CC800-RPTG<br />
Description<br />
C•<strong>CURE</strong>800 Enhanced Reporting option Includes licensing to enable the use of<br />
enhanced reporting on a C•<strong>CURE</strong> 800 Model 1 configuration. Generation of pre-packed reports does<br />
not require a Crystal reports license. Generation of custom reports by the end user does not<br />
require the user to acquire a separate Crystal reports v8.5 standard or Developer’s License. System<br />
serial number, fax number and contact name are required at time of order<br />
11
C•<strong>CURE</strong> 800<br />
C•<strong>CURE</strong> 800 Software Options<br />
Bi-directional Serial Interface<br />
C•<strong>CURE</strong> 800 provides third party device integration via<br />
bi-directional serial interface. The interface has been<br />
implemented to receive messages form third party devices and<br />
interpret them for C•<strong>CURE</strong>800. The messages are translated as<br />
C•<strong>CURE</strong>800 journal messages or as C•<strong>CURE</strong>800 events. The<br />
interface has been designed to communicate with he C•<strong>CURE</strong><br />
800 driver via RS-232 serial port or remotely though TC P/IP via<br />
a qualified terminal server. (Lantronix UDS-10 and SYSTECH<br />
models 3182, 3184, 3282 and 3284). The bi-directional<br />
interface provides output messages to third party devices by<br />
the use of action activation.<br />
The bi-directional interface is available with templates for use<br />
with an intercom or intrusion detection system, as well as a<br />
powerful user configurable option allowing interaction with<br />
many ASCII serial interface devices. The current templates for<br />
the bi-directional interface are for the Radionics 66500 and<br />
6600 intrusion alarm receivers and the Zenitel Stentofon<br />
AlphaCom M intercom system.<br />
Model Number<br />
CC800-Stent<br />
CC800-RAD2<br />
CC800-GPSERV<br />
Description<br />
Input/output serial interface option for Zenitel Stentofon AlpCom M<br />
Intercom<br />
Radionics bi-directional serial interface option. Includes licensing to<br />
enable communication with Radionics 6500 and D6600 receivers using the SIA protocol.<br />
* Requires running current MPU firmware 7.80 or higher on a D6510 MPU Card or any revision<br />
firmware on a D6511 MPU Card and be using the 6500 handler. 1.34 (for 7.80 and 7.82 D6510<br />
MPU) or 1.41 (for 8.00, 8.03 D6510 MPU, or any revision on a D6511 MPU card).<br />
General Purpose serial interface option - user configurable<br />
Central Monitoring<br />
The Central Monitoring option of C•<strong>CURE</strong>800 allows customers to monitor multiple C•<strong>CURE</strong> servers form one guard station<br />
with their existing C•<strong>CURE</strong> 800 system. Central Monitoring requires version 6.0.1 or higher, plus licensing for each server.<br />
12<br />
Model Number<br />
Description<br />
CENTMON-1S Central Monitoring Option - Software Only -<br />
Includes licensing to enable simultaneous alarm event monitoring of one regional C•<strong>CURE</strong> 800/8000<br />
server. System serial number, fax number and contact name are required at time of order.<br />
Notes<br />
• C•<strong>CURE</strong> 800 Central Monitoring is an option to provide centralised alarm event management for regional servers running either<br />
the C•<strong>CURE</strong> 800 or C•<strong>CURE</strong> 8000 system software.<br />
• Requires C•<strong>CURE</strong> 800 v 6.0.1 or higher on each server. System serial number is required for each server for proper licensing at<br />
time of order.
C•<strong>CURE</strong> 800 Software Options<br />
Guard Tour<br />
The Guard Tour option of the C•<strong>CURE</strong> 800 allows customers to set up pre-determined Guard Tours for security guards<br />
to follow in order to better automate their security processes. Guard Tour requires C•<strong>CURE</strong> 800/8000 version 6.0.1<br />
or higher.<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
CC800-GT<br />
Description<br />
C•<strong>CURE</strong> 800 Guard Tour Option-<br />
Includes licensing to enable Guard Tour for 1 C•<strong>CURE</strong> 800 /8000<br />
server.<br />
Broadcast Messenger Option<br />
The Broadcast Messenger provides C•<strong>CURE</strong> 800 users the ability to send a page via a modem to a paging service to an<br />
unlimited number of subscribers. The Broadcast Messenger is included with C•<strong>CURE</strong> 800 and 8000 plus and is an option<br />
for other C•<strong>CURE</strong> 800 Models.<br />
Model Number<br />
CC800-BM<br />
Description<br />
C•<strong>CURE</strong> 800 Broadcast Messenger Software Option Provides ability<br />
to send a page via modem a paging service such as Sky Page or via<br />
serial port to local paging terminal such s Motorola PeopleFinder for<br />
an unlimited number of subscribers.<br />
13
C•<strong>CURE</strong> 800 Software Options<br />
C•<strong>CURE</strong> NetVue<br />
C•<strong>CURE</strong> NetVue is an option within C•<strong>CURE</strong> 800/8000 that provides seamless integration with digital video management<br />
systems, such as American Dynamics’, Intellex, Nice Systems, Nice Vision, Pro and Harmony, and Loronix CCTV ware.<br />
Please provide system serial number, fax number and contact name at time of order.<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
Description<br />
CC800-NETVUEI C•<strong>CURE</strong> NetVue interface to Intellex (version 3.0)<br />
Includes licensing to enable C•<strong>CURE</strong> Netvue for 1<br />
C•<strong>CURE</strong> 800/8000 server and unlimited number of Intellux. This<br />
option requires C•<strong>CURE</strong> 800 v7.0 or higher<br />
CC8000-NETVUEN<br />
C•<strong>CURE</strong> NetVue interface to Nice System’s NiceVision<br />
(version 2.2) Includes licensing to enable C•<strong>CURE</strong> NetVue for 1<br />
C•<strong>CURE</strong> 800.8000 server and unlimited number of Nice Vision. This<br />
option requires C•<strong>CURE</strong> 800 V.7.0 or higher<br />
CC8000-NETVUENH<br />
C•<strong>CURE</strong> NetVue interface to Nice System’s NiceVision<br />
PRO (version 6.2) or Nice harmony (version 6.2)<br />
Includes licensing to enable C•<strong>CURE</strong> NetVue for 1 C•<strong>CURE</strong> 800/8000<br />
Server and unlimited number of Nice Vision PRO, or nice Harmony<br />
system. This option requires C•<strong>CURE</strong> 800 v8.0 or higher.<br />
CC8000-NETVUEL C•<strong>CURE</strong> NetVue interface to Loronix (version 4.0)<br />
Includes licensing to enable C • <strong>CURE</strong> NetVue for 1 C•<strong>CURE</strong><br />
800.8000 server and unlimited number of Loronix systems. This<br />
option requires C•<strong>CURE</strong> 800 v. 8.0 or higher.<br />
14
C•<strong>CURE</strong> 800 Software Options<br />
C•<strong>CURE</strong> NetVue - Quick Reference Chart<br />
C•<strong>CURE</strong> 800<br />
Intellex Loronix Nice<br />
Vendor Hardware DV8000 and CCTVware - Remote NiceVision,<br />
models supported DV16000 and Enterprise NiceVision Harmony<br />
and Nice Vision Pro<br />
Vendor Software V2.4 and V3.0 V4.0 NiceVision V2.0<br />
Version(s) Harmony & Pro V6.2<br />
supported<br />
Model Number CC800-NETVUEI CC800-NETVUEL CC800-NETVUEN<br />
MSRP $2,500 $5,000 $5,000<br />
<strong>Product</strong> Code B B B<br />
C•<strong>CURE</strong>800 DV16000 V7.0 and V8.0 and up Nice Vision - V7.0<br />
Version Supported up; DV8000 V7.2 and up; Harmony &<br />
and up<br />
Pro-V8.0 and up<br />
Area Lockout<br />
Allows users to deny personnel or personnel groups access from an area for a specified period of time. A user can<br />
configure lockouts for a single area or for area groups. The lockout timer starts when the personnel enter or exit the<br />
Lockout area. Utilised in conjunction with the iSTAR Intelligent Network Controller.<br />
Model Number<br />
CC800-ARALK<br />
Description<br />
Area Lockout option<br />
Includes licensing to enable the Area Lockout feature in all Models of C•<strong>CURE</strong> 800/8000 utilising the<br />
iSTAR Intelligent Network Controller .System serial number, fax number and contact name are required<br />
at time of order.<br />
Enhanced Password Protection<br />
The Enhanced Password Protection feature allows greater network security by increasing password administration and<br />
authentification.<br />
Model Number<br />
CC800-PSWRD<br />
Description<br />
C•<strong>CURE</strong> Enhanced Password Protection Option<br />
Includes licensing to enable the use of enhanced password protection feature used in conjunction with<br />
Windows 2000 and NT. Requires IT administrator to set up network permissions synchronised with the<br />
C•<strong>CURE</strong> 800 installation.<br />
15
C•<strong>CURE</strong> 800 Software Options<br />
Advanced Door Monitoring<br />
Advanced Door Monitoring adds up for monitoring doors, including lock sensor status inputs and various lock release<br />
devices such as:<br />
C•<strong>CURE</strong> 800<br />
• Fire Alarm<br />
• Crash Bar<br />
• Key Override<br />
• Power Failure<br />
The enhancement supports multiple release devices per door as well as multiple DSM and RTE inputs per door.<br />
Model Number<br />
CC800-ENHDOOR<br />
Description<br />
C•<strong>CURE</strong> 800 Advanced Door Monitoring Option<br />
System Serial number, fax number and contact name are required at time of order.<br />
Carpool Anti-passback<br />
Carpool anti-passback enforces anti-passback on a group of individuals configured as a carpool group. It allows users to<br />
change the passback information in multiple personnel records from a single card read. A user can designate carpool<br />
areas that enforce anti-passback for a specified group when a single specified card is read at the carpool area reader. The<br />
user can then grace the cardholders in this group.<br />
Model Number<br />
CC800-CRPL<br />
Description<br />
C•<strong>CURE</strong> 800 Carpool Anti-passback<br />
System serial number, fax number and contact name are required at time of order.<br />
16
C•<strong>CURE</strong> 800 Software Options<br />
C•<strong>CURE</strong> 800 Configuration (CF) Import/Export Tool<br />
Configuration (CF) Import/Export Tool allows users to design and enter some configuration data into a Microsoft Excel<br />
spreadsheet. This tool permits users to :<br />
C•<strong>CURE</strong> 800<br />
• Export configuration data from an existing C•<strong>CURE</strong> 800/8000<br />
• Create new configuration data without an existing C•<strong>CURE</strong> 800/8000<br />
• Import configuration data into C • <strong>CURE</strong> 800/8000<br />
Model Number<br />
CC800-CFTOOL<br />
Description<br />
C•<strong>CURE</strong> 800 Configuration Import/Export Tool<br />
This product is delivered on a separate CD. It requires one CFIE license per each C•<strong>CURE</strong> 800 system<br />
to be configured with CF Import/Export too.<br />
CC800-CFIE License for utilisation of CF Import/Export tool on each C•<strong>CURE</strong> 800.<br />
Requires CC800-CFTOOL<br />
17
Asset Management System<br />
C•<strong>CURE</strong> 800<br />
Radio Frequency Identification (RFID)<br />
Asset Management RFID Systems can be integrated with the C•<strong>CURE</strong> 800 Access Control System by utilising the Asset<br />
Manager option of the C•<strong>CURE</strong> 800. The RFID systems can be physically connected to the C•<strong>CURE</strong> 800 through a<br />
Weigand interface to a standard Software House RM board. The System comprises badges and tags of various types in<br />
conjunction with a receiver and transmit antennas. The antennas are available in various form factors allows the system<br />
to be configurable to meet many security and physical environmental requirements .<br />
Tyco Safety <strong>Product</strong>s do not stsock a RFID product at this time.NSL items such as PARSEL and WaveTrend should be<br />
considered.<br />
Model Number<br />
CC800-AMGR<br />
Description<br />
C•<strong>CURE</strong> 800 Asset Management Software Option<br />
Includes licensing to enable Asset management for 1 C•<strong>CURE</strong> 800/8000 server. System serial number,<br />
fax number and contact name are required at time of order.<br />
Visitor Management<br />
STOPwares PassagePoint Software<br />
C•<strong>CURE</strong> 800 supports visitor management using a third-party solution provided by STOPware, inc. With STOPware’s<br />
Passage Point TM , the front desk personnel can track visitors as they enter and exit the facility. With the optional Intranet<br />
module, employees can pre-register visitors utilising a web browser interface. By combining PassagePoint with the<br />
C•<strong>CURE</strong> 800 Integration Add-on license, front desk personnel can additionally issue access cards and search the C•<strong>CURE</strong><br />
cardholder directory.<br />
PassagePoint v4.0 Software Only<br />
Model Number<br />
CC800-STP41<br />
Description<br />
PassagePoint Professional v4.0 License<br />
Visitor badging & lobby security software<br />
PassagePoint Add-ons and Modules<br />
Model Number<br />
CC800-ST42<br />
Annual Software Support & Maintenance Plan<br />
Model Number<br />
CC800-STP60<br />
Description<br />
C•<strong>CURE</strong> 800 Integration Add-on License<br />
Link visitors to cardholders and activate access cards<br />
CC800-ST43<br />
PassagePoint Photo Capture Add-on License<br />
Capture, store and print visitor photos<br />
CC800-ST44<br />
PassagePoint Intranet/Internet Module License<br />
Pre-register visitors and groups via a web browser<br />
Description<br />
End User Priority Support for Passage Point<br />
Updates and new releases plus dedicated technical support via phone and Internet<br />
*<br />
Prices are per workstation. For volume pricing (20 seats or more)<br />
**<br />
Prices are per server, unlimited web user connections<br />
18
Integrated Security Management GUI<br />
C•<strong>CURE</strong> 800<br />
Integrated Security Management System GUI<br />
The C•<strong>CURE</strong> 800 - AEGIS Option enhances the overall<br />
C•<strong>CURE</strong> 800 user interface by allowing features such as<br />
CCTV, alarm and intercom systems to be combined<br />
graphically with the access control system to form a truly<br />
integrated security system. The application had a modular<br />
AEGIS Software<br />
Model Number<br />
CC800-AGS-SA<br />
AEGIS FIS<br />
CC800-AGS-FIS<br />
CC800-AGS-F-CC1A<br />
CC800-AGS-F-CC1B<br />
CC800-AGS-F-DV1<br />
CC800-AGS-F-CC3<br />
CC800-AGS-F-DV4<br />
CC800-AGS-F-IC3<br />
AEGIS NIS<br />
CC800-AGS-NIS<br />
CC800-AGS-N-CC1A<br />
CC800-AGS-N-CC1B<br />
CC800-AGS-N-DV1<br />
CC800-AGS-N-CL<br />
CC800 -AGS-N-CC3<br />
CC800-AGS-N-DV4<br />
CC800-AGS-N-IC2<br />
Software Upgrades<br />
CC800-AGS-SO-SU<br />
CC800-AGS-FUN-SU<br />
Description<br />
architecture allowing significant flexibility in system design,<br />
distributed processing and salability. AEGIS provides a<br />
consistent, simple user interface, where functions can be<br />
performed by point-and-click operation.<br />
AEGIS with C•<strong>CURE</strong> 800 support-standalone, no integration<br />
AEGIS with C•<strong>CURE</strong> 800 support - standalone, non-networked<br />
system.<br />
AD1024 CCTV option for CC800-AGS-FIS<br />
AD168/MP48 CCTV otion for CC800-AS-FIS<br />
Intellex DVR option for CC800-AGS-FIS<br />
Pelco 6800 CCTV option for CC800-AGS-FIS<br />
Firstline DVR option for CC800-AGS-FIS<br />
TOA VS900 Intercom option for CC800-AGS-NIS<br />
AEGIS with C•<strong>CURE</strong>800 support - networked integration system<br />
AD1024 CCTV option for CC800-AGS-NIS<br />
AD168/MP48 CCTV option for CC800-AGS NIS<br />
Intellux DVMS option for CC800-AGS-NIS<br />
Client Software (each workstation)<br />
Pelco 6800 CCTV option for CC800-AGS-NIS<br />
Firstline DVMS option for CC800-AGS-NIS<br />
TOA VS900 Intercom option for CC800-AGS-NIS<br />
Upgrade from SASS to FIS<br />
Upgrade from FIS to NIS<br />
19
C•<strong>CURE</strong> CENTRAL Web-based Security Management<br />
Centralised Photo Image Management<br />
Automated Database Recovery<br />
C•<strong>CURE</strong> 800<br />
Note: Only C•<strong>CURE</strong> central trained branches will be supplied with these products.<br />
Web browser access to centralised database of cardholder records<br />
Centralised personnel and cardholder administration<br />
Seamless integration with the C•<strong>CURE</strong> 800 system<br />
Sophisticated reporting capabilities for personnel and clearance information including scheduled<br />
and custom reports.<br />
Database independent, supporting Microsoft SQL Server 2000 in the first release<br />
Enables a single card to be valid across the entire enterprise of C•<strong>CURE</strong> 800 systems<br />
Scalable system to meet the needs of any enterprise<br />
Encrypted communications with Secure Sockets Layer (SSL) to enhance data security<br />
Filter Replication - provides faster selected replication of personnel data to servers<br />
Support for up to unlimited C•<strong>CURE</strong> 800 servers and 250,000 cardholders<br />
MS Windows 2000 support<br />
Intel Pentium IV processor support<br />
Allows C•<strong>CURE</strong> Central and C•<strong>CURE</strong>800 to run on one physical machine<br />
C•<strong>CURE</strong> Central allows users to administer personnel over a<br />
network of C•<strong>CURE</strong>800/8000 systems from a web browser<br />
application anywhere in the world. C•<strong>CURE</strong> Central uses<br />
central database to store personnel data from all servers in the<br />
C•<strong>CURE</strong> Central Network.<br />
C•<strong>CURE</strong> Central provides users with ability to manage<br />
centrally card enrolment in an enterprise access control<br />
system. Card holder updates are automatically distributed to<br />
all servers in the C•<strong>CURE</strong> Central Network. The platform<br />
independent architecture of C•<strong>CURE</strong> Central supports the<br />
industry standard network protocol, TCP/IP, which allows<br />
seamless integration with other systems and components<br />
that may already exist within an enterprise’s network.<br />
The C•<strong>CURE</strong> Central Client provides security in the form<br />
of authentication via a login username and password. All<br />
transactions between the browser client and the web server<br />
are encrypted via Secure Sockets Layer (SSL). In addition,<br />
public key encryption is used between the C•<strong>CURE</strong> Central<br />
server and the local C•<strong>CURE</strong> system servers to enhance data<br />
security.<br />
20
C•<strong>CURE</strong> CENTRAL Web-based Security Management<br />
C•<strong>CURE</strong> Central Minimum Hardware and Software Requirements<br />
C•<strong>CURE</strong> 800<br />
C•<strong>CURE</strong> Central Server<br />
Processor<br />
Pentium III 1.4GHz<br />
RAM<br />
512 MB<br />
Hard Disk Space<br />
Two 18 GB, 10000 RPM SCSI<br />
Monitor<br />
17”, 1024 X 768 PIXELS; 16 bit colour<br />
Ports<br />
2 serial, 1 parallel<br />
Video Adapter<br />
SVGA<br />
Network Adapter<br />
10 Base T or 100 Base Ethernet<br />
Operating System Windows NT 4.0 Service Pack 6a or higher, or Windows 2000<br />
Server Pack 1 or higher<br />
DBMS<br />
Microsoft SQL Server 2000 Service Pack 2 or higher or Oracle 8i<br />
C•<strong>CURE</strong> Central Client<br />
C•<strong>CURE</strong> Central Client<br />
Web Browser<br />
Internet Explorer<br />
v5.5 or higher<br />
Monitor 17”, 1024 x 768<br />
pixels; 16 bit colour<br />
Note: The C•<strong>CURE</strong> 800/8000 Nodes must be at v6.0.1 or higher.<br />
C•<strong>CURE</strong> Central System<br />
Model Number<br />
CCENT-U1<br />
CCCENT-U5<br />
CCCENT-S<br />
CC800-CCCR<br />
Description<br />
C•<strong>CURE</strong> Central Additional User License<br />
Includes license to add 1 additional simultaneous C•<strong>CURE</strong> Central User<br />
C•<strong>CURE</strong> Central Additional 5 User License<br />
Includes license to add 5 additional simultaneous C•<strong>CURE</strong> Central Users<br />
C•<strong>CURE</strong> Central Enterprise System - Software Only<br />
Includes C•<strong>CURE</strong> Central licensing for unlimited C•<strong>CURE</strong> 800/8000<br />
servers, and 2 simultaneous C•<strong>CURE</strong> Central Users.<br />
C•<strong>CURE</strong> Central Replication Option<br />
for all C•<strong>CURE</strong> 800/8000 Models.<br />
Note:<br />
Every C•<strong>CURE</strong> 800/8000 server must have the CC800-CCCR C•<strong>CURE</strong> Central option in order to be a node of the C•<strong>CURE</strong> Central Server. C•<strong>CURE</strong> Central has been successfully<br />
tested to support up to 10 C•<strong>CURE</strong> 800/8000 servers with 250,000 total cardholder records. However, as with all of our systems, C•<strong>CURE</strong> Central is designed<br />
for unlimited expansion and information on larger installations can be provided by your Area Sales Manager. All C•<strong>CURE</strong> Certified integrators and dealers must complete<br />
training on C•<strong>CURE</strong> Central prior to purchase. C•<strong>CURE</strong> Central installation requires network configuration and a review of each C•<strong>CURE</strong> 800/8000 database for initial<br />
installation. See additional Support Services for C•<strong>CURE</strong> Central on page 79.<br />
21
C•<strong>CURE</strong> 800 Badging Solutions<br />
C•<strong>CURE</strong> 800<br />
C•<strong>CURE</strong> 800 provides fully integrated photo imaging and<br />
badging applications that run on any C•<strong>CURE</strong> 800/8000<br />
Client supporting Windows NT or 2000. With the release of<br />
C•<strong>CURE</strong> 800v7.2, we now support a new badging option<br />
called C•<strong>CURE</strong> ID. C•<strong>CURE</strong> ID is a high performance,<br />
cost-effective system for any size organisation to produce<br />
permanent and temporary access badges. C•<strong>CURE</strong> ID<br />
allows the user to design professional quality badges,<br />
including text, logos, multiple colours, graphics, photos,<br />
C•<strong>CURE</strong> ID allows us to take advantage of opportunities not previously available:<br />
barcodes and signatures. C•<strong>CURE</strong> ID can be seamlessly<br />
integrated with C•<strong>CURE</strong> 800 and is designed to eventually<br />
replace both C•<strong>CURE</strong> Vision and VisionOne with similar<br />
feature set and superior usability.<br />
All existing Vision and VisionOne installations will seamlessly<br />
transition to C•<strong>CURE</strong> ID.<br />
1) Since the C•<strong>CURE</strong> Vision product is a 3rd party solution, we are limited to delivering only the new features the vendor<br />
offers. With C•<strong>CURE</strong> ID, we have the flexibility of adding new cutting-edge features including the V8.0 feature of enrolling<br />
biometric credentials through C•<strong>CURE</strong> ID.<br />
2) C•<strong>CURE</strong> ID eliminates the need for any external software licensing.<br />
C•<strong>CURE</strong> 800 IDS Badging<br />
Application Features No Badging C•<strong>CURE</strong> ID<br />
Configuration Features<br />
Capture Portraits No Yes<br />
Import Portraits Yes Yes<br />
Display Portraits Yes YES<br />
Display Signature YES YES<br />
Display Fingerprint NO NO<br />
Bundled Offering NO YES<br />
Signature Capture NO YES<br />
Cropping NO YES<br />
Device Setup NO YES<br />
Integrated Iris Control (Brightness) NO YES<br />
Synchronised Flash/Lighting NO YES 1<br />
Integrated Zoom NO YES 2<br />
Automatic Directory Tree for Images NO YES<br />
Choose Image Format NO YES<br />
Software Controlled Camera (CC800-VA2) NO YES<br />
Use of Multiple Images in Badge & Sheet NO YES<br />
Any device with TWAIIN or Video for<br />
interface NO YES<br />
Support for FlashBus, Flash 3D, and<br />
FlashPoint 128 NO YES 3<br />
1<br />
Synchronised flash feature is not available with the FlashPoint 3D Plus board. Flood lighting is recommended.<br />
2<br />
C•<strong>CURE</strong> ID displays entire capture area during capture. Panning of images is therefore not necessary.<br />
3<br />
Flashsbus MV Lite/Plus and Flash3D Lite/Plus are supported. The PRO versions of these boards are not supported.<br />
Plain white plastic cards are available for ID production testing - order in multiples of 100- 662.001.850.<br />
22
C•<strong>CURE</strong> 800 Badging Solutions continued<br />
C•<strong>CURE</strong> 800<br />
Application Features No Badging C•<strong>CURE</strong> ID<br />
Badge Layout Features<br />
Create/Edit Layout (WYSIWYG drawing<br />
environment) NO YES<br />
Application Features No Badging C•<strong>CURE</strong> ID<br />
Full Access to text properties NO YES<br />
Full Access to layout properties NO YES<br />
Rainbow Images NO YES<br />
Image “ghosting” and “see through” NO YES<br />
Zoom up to 300% for precise object<br />
alignment NO NO<br />
Create borders of text and image objects NO YES<br />
Create “on-the-fly” text and data strings NO YES<br />
Tool bar for quick access to badge design<br />
tools NO YES<br />
“Size to fit” and “maintain aspect ration” NO YES<br />
Data expressions for text NO YES<br />
Specify location of badging images YES YES<br />
Send Data To Badge Preview NO YES<br />
PRINTING FEATURES<br />
Badge Printing NO YES<br />
Double-Sided Printing NO YES<br />
Magnetic Encoding NO YES<br />
1D Barcode Support NO YES<br />
Batch Mode Printing NO YES<br />
2D Barcode Support NO YES<br />
CMI SecurCode Barcode Support NO NO<br />
Print to (pre-printed) badge forms NO YES<br />
Design Multi-Badge Sheet Layouts NO YES<br />
Specify Starting Position for Printing NO YES<br />
Specify Number Of Badges Held in<br />
Print Queue NO YES<br />
Sheet Layout NO YES<br />
Specify Alternate Resolutions NO YES<br />
Specify Offset Origin NO YES<br />
LANGUAGES<br />
Support Multiple Languages YES FUTURE<br />
NETWORK<br />
Stand-ALONE YES YES<br />
Shared Resources Across Multiple<br />
Workstations<br />
Note: Batch mode printing will work is Sheet Printing is enabled in this version.<br />
Special Note regarding Badging Support:<br />
Software House no longer offers the VisionOne and Vision badging options. The migration to the C•<strong>CURE</strong> ID badging solution was announced in<br />
November 2002 (TAB 2002-34), and again with the release of C•<strong>CURE</strong> 800 v 8.0 in January 2003.<br />
The C•<strong>CURE</strong> ID badging solution has been adopted by over 700 end-users since its launch in July 2002. The adoption rate of C•<strong>CURE</strong> ID confirms the<br />
products functionality and value over Vision or VisionOne (Imageware (ITC) products)-for example, C•<strong>CURE</strong> ID released in January 2003, with C•<strong>CURE</strong><br />
800 v8.0, allows the enrollment of biometric based credentials.<br />
Through the adoption of the C•<strong>CURE</strong> ID product Software House is able to add additional functionality to badging such as biometric enrollment, USB and<br />
IP camera support without additional cost to the customer.<br />
As of this release, users will be expected to upgrade from either VisionOne or Vision to the C•<strong>CURE</strong> ID badging solution. The Vision and Vision One<br />
badging solutions will be put into maintenance mode with no futurer releases planned after v8.0.<br />
As of April 2003, the upgrade cost from VisionOne to C•<strong>CURE</strong> ID in C•<strong>CURE</strong> 800 v 8.0 will be waived. The upgrade costs will be waived again with<br />
C•<strong>CURE</strong> 800 v8.1. Upgrading from Vision to C•<strong>CURE</strong> ID has been no cost since v7.2 of C•<strong>CURE</strong> 800 released in July 2002.<br />
EXISTING VISION CUSTOMERS: If you are currently a Vision customer using the CCD-2000 camera and are migrating to C•<strong>CURE</strong> ID, there will be a patch<br />
issued that will enable the camera to work with C•<strong>CURE</strong> ID that wil be released with C. <strong>CURE</strong> 800 v8.1.1. For Curent Vision owners, additional C•<strong>CURE</strong><br />
Vision licenses are available only with the following versions of C•<strong>CURE</strong> 800/8000:<br />
* English v7.2 and 8.0 * Japanese: v6.0<br />
* French, German, Spanish: 7.04, and 5.14 * Simplified Chinese: v8.06<br />
* Check: v 7.05 * Traditional: v8.07<br />
* Dutch: V7.0.12<br />
23
C•<strong>CURE</strong> ID Integrated Badging Management Solution<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
CC800-1ID<br />
CC800-IDS<br />
CC800/VCB-3DPLUS<br />
CC800-VA2<br />
CC800/CC<br />
CC800-311<br />
Description<br />
C•<strong>CURE</strong> 800 Model System Software Only with C•<strong>CURE</strong> ID<br />
Badging software license.<br />
Includes server software and 2 C•<strong>CURE</strong> Client Licences.<br />
C•<strong>CURE</strong> ID Software License<br />
Includes client license for complete C•<strong>CURE</strong> ID option which includes signature capture.display, twosided<br />
badge layouts, and batch mode printing, unlimited badge layouts, and batch mode printing.<br />
FlashPoint 3Dx Plus ViCapture Board<br />
Note: requires C•<strong>CURE</strong> 800 v5.1.1 or higher<br />
Camera & Cable: high image quality<br />
Supports software controlled iris and lens. Includes TWAIN driver software and cables.<br />
Camera & Cable for FlashPoint cards with CC800-VA2 camera<br />
Spare.<br />
Video Y Cable<br />
Required for Live Video Window Only (compatible with FlashPoint £Sx Plus and FlashPoint128)<br />
CC800/TWN<br />
FLASHBUS MV lite (TWAIN interface)<br />
CC800/SVC<br />
‘S’ Video Camera<br />
Includes lens and power supply<br />
200-301 6 foot ‘S’ Video cable for CC800/SVC camera<br />
Accessories<br />
CC800/CS<br />
CC800/FLO<br />
CC800-DIGI9101<br />
Cameral Stand<br />
Flood lighting option (120V AC)<br />
Digi International Watchport V/USB camera<br />
Software and documentation English only<br />
24
Video Equipment & Printers<br />
C•<strong>CURE</strong> 800<br />
A wide range of image capture and card<br />
printing products are detailed below. These<br />
provide all that is necessary for the capturing of<br />
images, designing ID and printing cards (via<br />
the access control software module)<br />
<strong>Product</strong> Codes<br />
636.006.184<br />
Ultra Magicard Rio ID printer with Windows 95<br />
and NT drivers.<br />
636.006.185<br />
Dye film type LC3/CYMCKO full colour film (350<br />
images)<br />
636.006.186<br />
Dye film type LCB/D resin black/OP Protective<br />
overcoat (600 images)<br />
636.006.187<br />
Cleaning Kit - 10 cards and 1 Pen<br />
662.001.850<br />
Plain White plastic cards - order in multiples of<br />
100 for testing printing and/or standard ID<br />
cards.<br />
25
C•<strong>CURE</strong> 800 Typical Controller Network<br />
C><strong>CURE</strong> 800 Typical System Schematic<br />
Controller Networks<br />
C•<strong>CURE</strong> 800<br />
C.<strong>CURE</strong> 800<br />
Model X<br />
apC/L<br />
LAN/WAN Belden 9842<br />
RS232 to 485<br />
Convertor<br />
apC/L apC/8x apC/L<br />
apC/8x<br />
NOTES:<br />
UDS10<br />
apC/8x apC/8x<br />
When a controller is wired directly into a PC serial<br />
port, only 1 apC/8x or apC/L can be connected.<br />
Maximum cable distance PC to controller is 15<br />
metres (serial)when set to RS232<br />
Up to 10 apC controllers on one comms line<br />
Belden 9842 (RS485)<br />
Maximum distance from convertor to last controller<br />
in the line is 1,200 metres<br />
Up to 6 apC controllers on a UDS10 comms line<br />
(still 1200m) when the UDS10 is set to RS485.<br />
Only one apC can be connected to a UDS10<br />
when set to RS232
iSTAR TM Intelligent Network Controller<br />
(Up to 16 doors per controller)<br />
C•<strong>CURE</strong> 800<br />
iSTAR is an Ethernet-ready embedded control panel for<br />
enterprise-wide security management. iSTAR operates with<br />
Software House’s RM Reader Services as well as industry<br />
standard Wiegand readers. Intended for use by both<br />
corporate security and information technology managers,<br />
the iSTAR controller represents a new way to organise and<br />
deploy security management solutions by seamlessly<br />
integrating with an existing network infrastructure.<br />
Designed with the network in mind, the iSTAR controller<br />
enables integration of various event management<br />
applications into one single embedded controller.<br />
At the heart of iSTAR is the General Controller Module<br />
(GCM). The GCM integrates Microsoft’s Windows® CE<br />
operating system, Motorola’s Power PC TM processor,<br />
network and communication ports, expandable memory and<br />
a PC Card type III slot. The GCM also supports up to two<br />
Access Control Modules (ACM) for versatile reader system<br />
integration. ase event-directed actions can be downloaded<br />
to the controller from the C•<strong>CURE</strong> 800/8000 database and<br />
journal host. Communications among multiple iSTARS can<br />
point-to-point via TCP/IP over Ethernet. Remote dial-up is<br />
also an option as a secondary back-up communications<br />
path. The advantaged access control networking allows<br />
ISTAR controllers to efficiently communicate directly to one<br />
another without host polling or intervention.<br />
Note: C•<strong>CURE</strong> 800/8000 v.5.2 or higher and complete training is required; all dealers<br />
must complete training on iSTAR system prior to purchasing.<br />
Ethernet Ready- Direct Ethernet connection with each<br />
iSTAR retaining a unique IP address. ISTAR can be<br />
deployed in clusters. A cluster can incorporate multiple<br />
panels employed over a WAN, allowing the cluster to<br />
include controllers in geographically disparate locations.<br />
Embedded Operating System. - Microsoft Windows CE<br />
and Motorola Power PC processor broaden application<br />
support and enhance speed.<br />
Seamless Integration - DHCP allows for automatically<br />
obtaining IP addresses: the C•<strong>CURE</strong> 800/8000 host networks<br />
for initial database set-up, managing peripheral<br />
hardwdare, generating activity reports, and managing<br />
multi-cluster events.<br />
Wide Range of Alarm Monitoring - Supports 2 ACMs,<br />
each providing 16 supervised inputs and 8 relay outputs<br />
(readers); i/8 and R/8 allow each additional input and output<br />
modules.<br />
Advanced Clustering for Unmatched Event Control and<br />
monitoring - Distributed management is supported<br />
through communications within a cluster.<br />
Database Backup on Power Failure - Eliminates the need<br />
to re-download entire database after power loss.<br />
Anti-Passback within A Cluster - stops or restricts access<br />
of personnel attempting to utilise the same security<br />
badge.<br />
Password Protected Web Based Diagnostics - Remote<br />
diagnostics utilising any networked computer, Web<br />
browser, and known iSTAR IP address.<br />
Expandable On-Board memory - On board memory<br />
options supporting expanded databases/events and<br />
future add-on functionality. 32Mb and 64Mb SIMM field<br />
upgradeable configurations available.<br />
Secure Communications - Industry tested encryption and<br />
multi-key authentication for enhanced security.<br />
System for the Future - Easily upgradeable flash ROM<br />
with future releases and iSTAR specific extended applications<br />
such as enhanced Intrusion Zones and Keyboard<br />
Commands.<br />
Worldwide Compliance - FCC, CE, C-TCK, UL 294 and UL<br />
1076.<br />
27
iSTAR TM Intelligent Network Controller<br />
C•<strong>CURE</strong> 800<br />
iSTAR vs. apC Comparisions<br />
iSTAR TM<br />
• Embedded Ethernet -DHCP support for automatically<br />
obtaining IP address (new with v3.0)<br />
• Supports secondary communication paths - dialup,<br />
serial (utilising RAS) or Ethernet (new with v3.0)<br />
• Peer-to-per with master/slave designations<br />
(advanced clustering)<br />
• Global anti-passback support<br />
• Asynchronous communication with the host<br />
• 32 MB RAM (field upgradeable)<br />
• 64 MB RAM (field upgradeable )<br />
• 8 to 16 reader support<br />
apC ® 8X<br />
• For Ethernet integration, optional terminal server<br />
available for networking<br />
• Serial and dialup communication support<br />
• Client/server host dependent<br />
• Local anti-passback support (all readers must be<br />
on same apC)<br />
• Synchronous communication with the host<br />
• 4 MB RAM maximum (factory upgradeable)<br />
• 8 reader support<br />
• Max. 192 inputs (all supervised), 177 outputs per<br />
controller<br />
• Configuration set up and diagnostics via a web<br />
browser on any LAN networked computer<br />
• PCMCIA Card add-on peripherals*<br />
• Max. 128 inputs (of which, 120 are supervised),<br />
192 outputs per panel<br />
• apC diagnostic tool via serial connection<br />
• External modem optional<br />
• Automatic fall back to dialup communications if<br />
network goes down<br />
(C•<strong>CURE</strong> 800/8000 v5.2 or higher required for<br />
automatic fallback to dialup communications.)<br />
• Enhanced Intrusion Zones and Keyboard Commands<br />
28
iSTAR Intelligent Network Controller<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
STAR008W-16<br />
STAR008W-32<br />
STAR008W-64<br />
STAR016W-16<br />
STAR016W-32<br />
STAR016W-64<br />
Description<br />
16MB RAM General Controller Module with one Access Control<br />
Module for up to 8 readers (Wiegand or RM)<br />
32 MB RAM General controller Module with one Access Control<br />
Module for up to 8 readers (Wiegand or RM)<br />
64 MB RAM General Controller Module with one Access Control<br />
Module for up to 8 readers (Wiegand or RM)<br />
16MB RAM General Controller Module with two Access Control<br />
Module for up to 16 readers (Wiegand or RM)<br />
32 MB RAM General Controller Module with two Access Control<br />
Module for up to 16 readers (Wiegand or RM)<br />
64 MB RAM General Controller Module with two Access Control<br />
Module for up to 16 readers (Wiegand or RM)<br />
Additional Board, Memory Upgrades & Replacement Parts<br />
Model Number<br />
STAR-ACM8-W<br />
STAR-32MU<br />
STAR-64MU<br />
STAR-32MU<br />
STAR-64MU<br />
STAR-AP<br />
STAR-PS<br />
STAR-RB<br />
STAR-TB<br />
AS0063ISTR<br />
Description<br />
Add-on Access Control Module (ACM)<br />
Includes 1 x 32 MB DRAM and 32 MB flash ROM<br />
Upgrade to 32 MB<br />
Includes 1 x 32 MB DRAM and 32 MB flash ROM<br />
Upgrade to 64MB<br />
Includes 1 x 64 MB DRAM and 64 MB flash ROM<br />
Upgrade to 32 MB<br />
Includes 1 x 32 MB DRAM and 32 MB flash ROM<br />
Upgrade to 64MB<br />
Includes 1 x 64 MB DRAM and 64 MB flash ROM<br />
Adapter plate kit to mount one GCM and one * reader ACM in an<br />
existing apC/8X enclosure<br />
Includes 60 wat power supply, LED board and wiring for enclosure door, manuals and mounting<br />
hardware.<br />
Replacement Power Supply, 12V-60 Watt<br />
Replacement iSTAR Relay Board for legacy STAR-ACM8 or<br />
current STAR-ACM8-W<br />
Replacement ACM interface board with cable assembly<br />
iSTAR Power Supply cable (spare)<br />
to be used with an external power supply. See apS on page 56<br />
STARGC-16MB<br />
General Controller Module, with ACM interface board and 16 MB<br />
RAM and 16 MB flash ROM.<br />
Enclosure not included.<br />
STARGC-32MB General Controller Module, with ACM interface board and 32<br />
MB RAM and 32 MB flash ROM<br />
STARGC-64MB<br />
Enclosure not included.<br />
General Controller Module, with ACM interface board and 64MB<br />
RAM and 64MB flash ROM<br />
Enclosure not included.<br />
29
iSTAR Power Consumption Chart<br />
iSTAR Power Consumptions<br />
Circuit Boards<br />
C•<strong>CURE</strong> 800<br />
iSTAR GCM boards<br />
290 mA<br />
iSTAR ACM boards<br />
150 mA<br />
RM4 board<br />
75 mA<br />
Active Relay<br />
25 mA<br />
i/8 option board 120 mA<br />
R/8 option board 100 mA + active relays<br />
Readers<br />
Indala ASR-101,103,105,110,112<br />
Indala PR5, 10, 12<br />
Indala ASR-120-122<br />
Indala PR20-22<br />
Sensor Eng WR1, WR2<br />
Hughes MiniProx<br />
Hughes ProxPro<br />
Hughes MaxiProx<br />
3rd Party Options<br />
150mA<br />
130mA<br />
350mA<br />
350mA<br />
30mA<br />
60mA<br />
100mA<br />
200mA<br />
PCMCIA Modems<br />
Hayes Accure v.90/K56<br />
PCMCIA Ethernet<br />
Linksys PCM100<br />
220mA<br />
260mA<br />
apS Standby Power Example<br />
iSTAR with 1 ACM board 440 (290 + 150)<br />
8 RM4 boards 600 (75 *8)<br />
8 Indala ASR-101 readers 1,200 (150*8)<br />
PCMCIA modem 220<br />
Total mA required 2,460mA<br />
30
apC®/8X Advanced Processing Controller<br />
(Up to 8 readers per controller)<br />
KEY<br />
Proximity Reader<br />
Magnetic Lock<br />
Egress Button<br />
Sounder<br />
Keyswitch for over-ride of maglock<br />
from secure side if required<br />
ARM-1 Relay Module<br />
RM-4 Reader Personality Module<br />
RM-4K Reader & PIN Module<br />
RM-4W Reader & PIN Module (wiegand burst)<br />
See typical door schematic for more details<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
*12Volt d.c.<br />
1 Amp PSU<br />
**<br />
RM-4<br />
NOTES<br />
RM-4K required for keypad with matrix/row & column output<br />
RM-4W required for keypad with wiegand 8 burst<br />
Standard ‘ADT’ C.<strong>CURE</strong> 800 Schematic<br />
apC/8x with RM-4s<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
*12Volt d.c.<br />
1 Amp PSU<br />
8 outputs strobe,<br />
sounder etc. CCTV<br />
switch (requires<br />
PSU feed?)<br />
***<br />
Output<br />
Module<br />
**<br />
Input<br />
Module<br />
***<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
*12Volt d.c.<br />
1 Amp PSU<br />
8 inputs<br />
contacts etc.<br />
RM-4W<br />
C•<strong>CURE</strong> 800<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
*12Volt d.c.<br />
1 Amp PSU<br />
RM-4<br />
apC/8x<br />
**<br />
Star Coupler<br />
Secure side of the<br />
door<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
*12Volt d.c.<br />
1 Amp PSU<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
*12Volt d.c.<br />
1 Amp PSU<br />
** **<br />
RM-4K<br />
RM-4<br />
* Local door PSU should be selected based on the local lock<br />
power and RM-4 reader requirements<br />
** Power & date from apC to RM-4 + I/O boards is via Belden<br />
9841 (Comms) + Belden 8760 (Power)<br />
*** Local power may be required to support relay requirements<br />
etc.
apC®/8X Advanced Processing Controller<br />
(Up to 8 readers per controller)<br />
The apC/8X Advanced Processing Controllers are intelligent access control and alarm monitoring panels which serve as the<br />
basic building block for all Sensormatic ACD propriety security management systems. Many innovative design features make<br />
the apC/8X more reliable, easier to service and less expensive to own than other intelligent field panels.<br />
C•<strong>CURE</strong> 800<br />
The CMOS Motorola 68000 16-bit processor gives the apC/8X maximum flexibility in card population and in utilising its<br />
numerous firmware features. The apC/8X is available with up to 512K of ROM which is used to store the panel’s program and<br />
4 Megabyte of static RAM which is used to store the “local” access control database, input/output configurations, and off-line<br />
transactions. The panel’s CMOS static RAM consumes minimal power for data storage, allowing longer on-board memory<br />
preservation.<br />
The CMOS Motorola 68306 16-bit processor gives the apC/8X maximum flexibility in card population and in utilising its<br />
numerous firmware features. The apC/8X is available with up to 4MB static RAM and 4MB EPROM and FLASH ROM. The<br />
panel’s CMOS static RAM consumes minimal power for data storage, allowing longer on-board memory preservation. The<br />
FLASH ROM makes firmware updates quick and easy.<br />
The apC/8X supports optional add-on modules. The modular design along with its innovative firmware make the apC/8X a<br />
powerful and flexible platform for a wide variety of access control, alarm monitoring and integrated security applications.<br />
Multiple card technologies and card formats can be used on he same apC/8X, making it ideal for single and multiple tenant<br />
applications and for retrofit of existing systems. The apC/8X bus architecture reduces wiring requirements and overall<br />
installation costs.<br />
32
apC®/8X Advanced Processing Controller<br />
(Up to 8 doors per controller)<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
apC/8X Base Configurations<br />
AS0100-004<br />
AS0100-008<br />
AS0100-016<br />
AS0100-004NPS<br />
AS0100-004NPS<br />
AS0100-004MB<br />
AS0100-008MB<br />
Description<br />
apC/8X Readers 1MB Memory, FLASH ROM<br />
with Enclosure and power supply<br />
apC/8X Readers 2MB Memory, FLASH ROM<br />
with Enclosure and power supply<br />
apC/8X Readers 4MB Memory, FLASH ROM<br />
with Enclosure and power supply<br />
apC/8X 1MB FLASH, Enclosure, No power supply or cable<br />
apC/8x 1MB FLASH Enclosure, No power supply or cable<br />
apC/X 1 MB Panel motherboard only<br />
apc/8X 2MB Panel motherboard only<br />
AS0100-016MB<br />
apc/8X 4MB Panel motherboard only<br />
Model Number<br />
apC/8X Memory Upgrades<br />
RAAS0100-1MU<br />
RAAS0100-2MU<br />
RAAS0100-3MU<br />
RAAS0100-4MU<br />
RAAS0100-5MU<br />
RAAS0100-6MU<br />
FW-APC<br />
FW-APC8X<br />
FW-DPC<br />
FW-APCL<br />
Description<br />
apC/8X Upgrade from 256K to 1 MB<br />
apC/8X Upgrade from 256K to 2 MB<br />
apC/8X Upgrade from 256K to 4 MB<br />
apC/8X Upgrade from 1MB to 2 MB<br />
apC/8X Upgrade from 1MB to 4 MB<br />
apC/8X Upgrade from 2MB to 4 MB<br />
Firmware Upgrade Kit for apC (current firmware)<br />
(EPROM)<br />
Firmware Upgrade Kit for apC/8X (current firmware)<br />
(Flash)<br />
Firmware Upgrade Kit for dpC (current firmware)<br />
(EPROM)<br />
Firmware Upgrade Kit for apC/L (current firmware)<br />
(Flash)<br />
Model Number<br />
apC Memory Upgrades<br />
RAAS0032-1MU<br />
RAAS0032-2MU<br />
RAAS0032-3MU<br />
Description<br />
apC/8X Upgrade from 128K to 256K<br />
apC/8X Upgrade from 128K to 1MB<br />
apC/8X Upgrade from 256K to 1 MB<br />
33
apC/8X Advanced Processing Controller<br />
apC®/8X Optional Modules<br />
C•<strong>CURE</strong> 800<br />
Model Number<br />
Input and Output Modules<br />
AS0015-00<br />
AS0074-000<br />
AS0073-000<br />
AS0016-00<br />
Star Coupler Modules<br />
AS0020-00<br />
AS0020-01<br />
AS0054-00<br />
AS00540-01<br />
General Options<br />
AS002<br />
Description<br />
apC/I32 32 supervised input module for dpC, apC, apC/8X and<br />
iSTAR<br />
Eight output reader bus module - requires 12Volt dc supply and<br />
enclosure<br />
Eight input reader bus module<br />
apC/8X R48, 48 output relay board for dpC, apC, apC/8X and<br />
iSTAR<br />
apC/8X Star Coupler module (8 readers, 8 in/8 out)<br />
apC/8X Mini-Star Coupler (8 readers)<br />
Wiegand/proximity Star Coupler base module (4 reader/4 input)<br />
Wiegand/proximity Star Coupler extension module (4reader/4<br />
input)<br />
Redundant communications converter - RS232 to dual RS485<br />
Host side)<br />
apC®/8X Spare/Miscellaneous Parts<br />
Model Number<br />
AS0100CAB<br />
AS0060-00<br />
KT0074-000<br />
KT0073-000<br />
PL-0140-000<br />
PL-0140-001<br />
Description<br />
apC/8X power supply cable: apC to apC power supply (spare)<br />
apC/8X power supply w/cable (spare)<br />
Output module connector kit (spare kit)<br />
Input module connector kit (spare kit)<br />
apC connectors (spare)<br />
apC connector kit, includes tamper and power (spare)<br />
34
apc®/L Advanced Processing Controller<br />
The apC/L is an intelligent access control and alarm monitoring control panel which serves as a basic building block for all of<br />
the C•<strong>CURE</strong> 800 security management systems. It is a two-door version panel making it an economical solution for parking<br />
garages, small office buildings, retail outlets and apartment complexes, or for remote site monitoring. Like the apC/8X, the<br />
apC/L has many innovative design features which make it more reliable, easier to service, and less expensive to own than<br />
other intelligent field panels.<br />
C•<strong>CURE</strong> 800<br />
The CMOS Motorola 68306 16-bit processor gives the apC/L maximum flexibility in card population and in utilising its<br />
numerous firmware features. It is available with 512KB static RAM that consumes minimal power for data storage, allowing up<br />
to 80 hours of on-board memory preservation. It supports optical input and output modules that can be added to provide more<br />
flexibility for a variety of access control, alarm monitoring, and integrated security applications.<br />
Multiple card reader technologies and card formats can be used on the same apC/L. This makes it ideal for single and<br />
multiple tenant applications and for retrofitting existing systems. In addition, the bus architecture reduces wiring requirements<br />
and overall installation costs.<br />
The apC/L offers advanced technology, flexibility, and low ownership cost.<br />
Features<br />
• Fast Stand-alone processing<br />
• 255 time commands for automatic input, output, and reader mode control<br />
• Support for magnetic tape,Wiegand, and proximity card technologies<br />
• Card, keypad, or car and keypad access support<br />
• Reader-by-reader support for variable card formats, site codes, company codes, and card<br />
technologies<br />
• Class A, 2-wire supervised input capability with optional input modules FLASH memory<br />
• Internal activation and expiration dates for cardholders<br />
• Real time full-year clock and calendar<br />
• Dynamic memory allocation between card and events storage<br />
• Communications between host and apC/L through network connection (via comor network ports) or<br />
dial-up mode<br />
• Up to 80 hours on board memory retention in case of power failure<br />
• Battery backup option<br />
apC ® /L Memory<br />
The apC/L event storage capacity is automatically adjusted according to the memory required for storing cardholder<br />
information. Increasing the number of cardholder records stored decreases the number of events (transactions) that can be<br />
held.<br />
Adding optional features may reduce the number of cardholder records and event storage space as the record size increases.<br />
apC ® /L 2-Door Advanced Processing Controller<br />
Model Number<br />
AS0101-003<br />
AS0101-003MB<br />
FW-APCL<br />
AS0101-600<br />
AS0101-501<br />
Description<br />
apC/L202F, 2 readers, 512K Memory FLASH with transformer<br />
apC/L2F motherboard only, 512K Memory FLASH (spare)<br />
Firmware Upgrade Kit for apC/L (Flash)<br />
Battery and cable for apC/L<br />
apC/L XFR 18 VAC Wall Transformer<br />
35
apC/L Typical Schematic 1<br />
KEY<br />
Proximity Reader<br />
Magnetic Lock<br />
Egress Button<br />
Keyswitch for over-ride of maglock<br />
from secure side if required<br />
RM-4 Reader Personality Module<br />
See typical door schematic for more details<br />
RM-4 **<br />
8 outputs strobe,<br />
sounder etc. CCTV<br />
switch<br />
Output<br />
Module**<br />
*12Volt d.c.<br />
1 Amp PSU<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
C•<strong>CURE</strong> 800<br />
Standard C.<strong>CURE</strong> 800 Schematic<br />
apC/L<br />
RM-4 **<br />
apC/L<br />
Secure side of the<br />
door<br />
* Local door PSU should be selected based on the local lock<br />
power and RM-4 reader requirements<br />
** RM-4 & I/O PCBs require an enclosure - we recommend part<br />
number 662.003.102<br />
Input<br />
Module**<br />
8 inputs<br />
contacts etc.<br />
Cable Schedule<br />
Network apC/L to apC Belden 9842<br />
apC to RM-4 Belden 9841 + 8760<br />
RM-4 to Reader Belden 9536<br />
RM-4 to Breakglass to Lock * Belden 8760<br />
RM-4 to Sounder/Egress Button/Door Contact Belden 8761 per device<br />
RM-4K to Reader Belden 9536<br />
RM-4K to Keypad 12 core screened<br />
* Lock cable type subject to volt drop AND consider keyswitch for Lock over-ride from unsecure side
apc®/L Advanced Processing Controller<br />
Reader<br />
C•<strong>CURE</strong> 800<br />
Sounder<br />
RM4-K<br />
apC/L Typical System Schematic<br />
Cable Schedule<br />
Network apC/L to apC Belden 9842<br />
apC to RM-4 Belden 9841+ 8760<br />
RM-4 to Reader Belden 9536<br />
RM-4 to Breakglass to Lock * Belden 8760<br />
RM-4 to Sounder/Egress Button/Door Contact Belden 8761 per device<br />
RM-4K to Reader Belden 9536<br />
RM-4K to Keypad 12 core screened<br />
* Lock cable type subject to volt drop AND consider keyswitch for Lock over-ride from unsecure side<br />
To next apC<br />
apC/L<br />
Secure Area<br />
12Vd.c. 3<br />
Amp PSU<br />
From apC//PC To next apC<br />
apC/L<br />
240Vd.c. Unswitched<br />
Fuse Spur<br />
RM-4<br />
RM-4K<br />
Door<br />
Contact<br />
12Vd.c. 3<br />
Amp PSU<br />
Reader<br />
Egress<br />
Button<br />
Breakglass<br />
Box<br />
Double<br />
Maglock<br />
Reader &<br />
Keypad<br />
RM-4K personality module used where 3x4 matrix keypad is required<br />
Unswitched<br />
Fuse Spur<br />
Note: RM-4 & RM-4K are supplied<br />
as PCBs & require enclosure<br />
Maglock<br />
Mini Trunking<br />
Door<br />
Control<br />
Keypad &<br />
Reader<br />
Egress<br />
Break<br />
Glass<br />
RM-4
Power Supplies<br />
Part Numbers<br />
C•<strong>CURE</strong> 800<br />
Stock Code<br />
<strong>Product</strong> Description<br />
662.008.105 12Vdc 10A(8 lock outputs) - Specified where an apC-8x is<br />
designed with a central lock PSU. Note MAX of 1 Amp (12Vdc)<br />
per lock. Not required for where all the doors have local power<br />
supplies.<br />
603.001.183 12Vdc 4 Amp power supply for use with ap C/L RM-4 and local<br />
door ancillaries<br />
659.001.022 12 Vdc 1 Amp power supply in metal housing<br />
PS-1270<br />
12 Volt dc 7 Ah battery<br />
38
C•<strong>CURE</strong> 800<br />
Card Readers, Access Cards and Accessories<br />
Access Control Readers<br />
Software House offers a wide range of<br />
access control card readers and card<br />
reader accessories to work with its apC<br />
family and iSTAR access control<br />
devices.<br />
The RM Series Cards Readers offer<br />
you a choice of three access control<br />
technologies - Proximity, Wiegand and<br />
magnetic Stripe using the same<br />
attractive housing. This universal<br />
design lets you mix and match different<br />
technologies on the same system while<br />
maintaining an consistent appearance.<br />
All RM Series readers come with three<br />
separate LEDs (red, green, amber),<br />
which indicate a range of conditions.<br />
An audible alert can also be set from<br />
the system host. The readers also<br />
provide two supervised inputs and two<br />
outputs.<br />
A keyboard (RM2 series) can also be<br />
added to any RM Series reader for PIN<br />
use. Optionally, a backlit LCD display<br />
(RM2 Series) can be added to any RM<br />
Series Reader. The display shows the<br />
time, date, system conditions, and<br />
various user prompts (in English).<br />
The RM Series Card Readers are<br />
compatible with existing apC/.8Xs and<br />
MRM readers, although it may be<br />
necessary to upgrade the apC/8X<br />
firmware. All RM Series Readers use<br />
the same wire and connectors which<br />
simplifies installation and service.<br />
Access Control Cards<br />
Software House offers a complete line<br />
of access cards for use with its card<br />
reader products. Cards are offered<br />
with sequential numbering which is<br />
either hot-stomped onto the card or<br />
otherwise engraved when appropriate.<br />
Magnetic stripe cards are offered with<br />
encoding either at the factory or by<br />
the user. Magnetic stripe access cards<br />
are available with the Software house<br />
logo. These attractive cards are<br />
offered with special pricing, and can be<br />
printed on the reverse side with your<br />
proprietary text message.<br />
Custom Printing<br />
Contact the Tyco Safety <strong>Product</strong> Card<br />
Bureau for special custom artwork<br />
requirements for access cards with<br />
multi-colour printing and company<br />
Logos. Because custom card orders<br />
have longer lead times, be sure to<br />
order custom cards well in advance of<br />
their anticipated use.<br />
Software House RM Boards & Accessories<br />
Model Number<br />
Proximity Version RM- HID<br />
RM1-PH<br />
RM2-PH<br />
RM2LPH<br />
RM3LPH<br />
Description<br />
RM Series Proximity Reader HID<br />
(26 or 37 bit)<br />
RM Series Proximity Reader HID with keypad<br />
(26 or 37 bit)<br />
RM Series Proximity Reader HID with keypad and LCD<br />
(26 or 37 bit)<br />
RM Series Mullion Proximity Reader HID<br />
(26 or 37 bit)<br />
The RM series readers are supplied with an RM-4 board.<br />
Note: Where local door ower supplies are used for lock switching, the ARM-1 board is required.<br />
39
Software House RM Series Card Readers<br />
Where Weigand boards have been included with apC8 or iSTAR OR an RM-4 is being used. Standard Wiegand or clock and date<br />
readers can be used subject to the format being made available. Alternatively RM-4 PCB’s can be supplied at the door position.<br />
these PCBs required an enclosure.<br />
C•<strong>CURE</strong> 800<br />
The range of HID Proximity or MR Access Mag stripe reader can therefore be connected to the C•<strong>CURE</strong> 800 range of controllers -<br />
system operation being subject to the card format in all cases.<br />
Model Number<br />
Description<br />
662.003.102 ARM-4 enclosure will accept 2 x RM-4 PCB’s.<br />
RM-4<br />
RM Series personality Module with tamper switch 1 PCB ONLY<br />
RM-4K<br />
RM Series Personality Module with Keypad Cable PCB ONLY<br />
Assembly with tamper switch<br />
RM-4W<br />
RM Series Personality Module with tamper switch and support for<br />
keypad data via Wiegand data stream PCB ONLY<br />
KT-0070-000<br />
RM-4 connector kit (Spare kit)<br />
662.003.102 RM-4 connection box - holds 2 x RM-4 PCBs<br />
662.003.101 ARM-1 auxiliary reader relay module for MRM/RM series readers<br />
1<br />
The RM-4 Personality Module connects a Wiegand or Proximity card reader to a dpC or apC controller. The RM-4 is a circuit board only, and must be mounted in an installer<br />
provided enclosure.<br />
RM-4 Wiring Diagram<br />
240 Volt a.c.<br />
Unswitched Fuse<br />
Spur<br />
PSU<br />
ARM-1<br />
Enclosure<br />
RM-4<br />
PCB<br />
Door Contact<br />
Maglock<br />
Breakglass<br />
Box<br />
Egress<br />
Button<br />
Reader<br />
40
Card Readers, Access Cards and Accessories<br />
Typical C•<strong>CURE</strong> 800 RM-4 Door System Schematic<br />
From apC/8x<br />
or RM-4<br />
Unswitched<br />
Fuse Spur<br />
PSU<br />
ARM-1<br />
Maglock<br />
Egress<br />
Secure Area<br />
240Va.c.<br />
Unswitched<br />
Fuse Spur<br />
To next RM-4<br />
Mini Trunking<br />
Reader on outside<br />
of area<br />
Break<br />
Glass<br />
Reader<br />
C•<strong>CURE</strong> 800<br />
PSU<br />
ARM-1<br />
Door Contact<br />
Maglock<br />
RM-4 *<br />
Breakglass<br />
Box<br />
Egress<br />
Button<br />
*RM-4 is supplied as a PCB only.<br />
Use enclosure 662.003.102<br />
RM-4<br />
41
Proximity - HID Cards<br />
Please note that not all HID parts are held in stock at Letchworth. These parts are set-up in JD Edwards to make ordering<br />
through S&I easier.<br />
C•<strong>CURE</strong> 800<br />
HID ProxKey II Fob. With new and repeat<br />
card orders, you must supply card format,<br />
facility code/site code & ID number page.<br />
Note: ID numbers must not be duplicated. Order in<br />
multiples of 100.<br />
HID PROXCARD II (proximity card) - non<br />
printable. With new and repeat card orders,<br />
you must supply card format, facility code/site<br />
code & ID number page.<br />
<strong>Product</strong> Code<br />
662.001.911<br />
HID ProxKey II Fob (keyring styled proximity<br />
fob).<br />
<strong>Product</strong> Code<br />
662.001.912<br />
HID PROXCARD II (proximity card)<br />
Note: ID numbersmust not be duplicated. Orderin<br />
multiples of 100.<br />
HID DuoProx (Proximity and Mag stripe<br />
technology) printable on one side only.<br />
With new and repeat card orders, you must<br />
supply card format, facility code/site code &<br />
ID number page.<br />
<strong>Product</strong> Code<br />
662.001.914<br />
HID Duo Prox<br />
Note: ID numbers must not be duplicated. Order in<br />
multiples of 100.<br />
HID IsoProx II (Photo, Credit card size) -<br />
printable. With new and repeat card orders,<br />
you must supply card format, facility code/site<br />
code & ID number page.<br />
<strong>Product</strong> Code<br />
662.001.915<br />
HID IsoProx II (Photo, Credit Card Size)<br />
Note: ID numbers must not be duplicated.<br />
Order in multiples of 100<br />
Plain white plastic cards are available for ID production testing - order in multiples of 100- 662.001.850<br />
42
HID Proximity Readers<br />
Proxpoint reader - compact design, with LED<br />
and Beeper - Dark grey.<br />
<strong>Product</strong> Code<br />
662.002.311<br />
Proxpoint reader<br />
C•<strong>CURE</strong> 800<br />
HID MiniProx proximity reader (Mullion, Thin<br />
size) Terminal Connections - Dark grey.<br />
<strong>Product</strong> Code<br />
662.002.312<br />
HID MiniProx proximity reader<br />
HID ProxPro proximity reader - Dark grey.<br />
<strong>Product</strong> Code<br />
662.001.315<br />
HID ProxPro proximity reader<br />
HID NT Maxi Prox Extended range reader -<br />
requires UKA-AXC013 24VDC PSU.<br />
<strong>Product</strong> Code<br />
662.002.316<br />
HID NT Maxi Prox Extended range reader<br />
HID ProxPro with Keypad card reader (3*4<br />
Matrix) Dark grey.<br />
<strong>Product</strong> Code<br />
662.002.317<br />
HID ProxPro with Keypad card reader<br />
43
Magnetic Stripe - Readers<br />
<strong>Product</strong> Code<br />
636.002.003<br />
Indoor Swipe Reader with LED Black Die-Casst<br />
Magneto-Resistive. For Use with 3M Hi-Co Tape<br />
C•<strong>CURE</strong> 800<br />
<strong>Product</strong> Code<br />
636.002.015<br />
Outdoor Swipe Reader (Chrome) - 30 to 70c. For<br />
use with 3M Hi-Co Tape<br />
<strong>Product</strong> Codes<br />
636.002.016<br />
Outdoor Swipe Reader (Black Die-Cast - 30<br />
to 70c. For use with 3M Hi-Co Tape.<br />
44
Magnetic Stripe - Cards<br />
<strong>Product</strong> Code<br />
636.001.802<br />
Blank Both Sides Graphics Quality Unencoded<br />
3M Hi-Co PVC Card.<br />
<strong>Product</strong> Code<br />
636.001.803<br />
Blank Graphics Quality Encoded 3M Hi-Co PVC<br />
Card- Includes Return Address on Reverse and<br />
Printed Card Number<br />
<strong>Product</strong> Code<br />
636.001.804<br />
ADT Branded Encoded 3M Hi-Co PVC Card-<br />
Includes Return Address on Reverse and Printed<br />
Card Number<br />
Plain white plastic cards are available for ID production testing - order in multiples of 100- 662.001.850.<br />
45
Verid Biometric Reader<br />
Features<br />
C•<strong>CURE</strong> 800<br />
• Easy Installation, no change to system software<br />
• Fingerprint verification in less than 1 second<br />
• Multiple finger enrollment for some or all users<br />
• Administrator selectable security levels. Option of<br />
individual settings<br />
• Accepts standard format Proximity readers<br />
• Input and output data signals identical on finger match<br />
• Easy to follow LED and user-definable LCD instructions<br />
• Users’ template held Verid’s internal database<br />
• RS485 Network for automatic updates of internal database<br />
• Automatic configuration and database synchronisation of<br />
new units added to a network<br />
The Verid Fingerprint Reader provides Access Control systems with<br />
instant improved security. Installed between existing Mag Stripe +<br />
proximity readers and the door controller. Verid confirms the presence<br />
of the correct person. No changes are needed to the cards, readers or<br />
Access Control system software. The complete verification process and<br />
database are all held within the single wall mounting housing which<br />
contains fixing terminals for the data cables. Two versions of the reader<br />
are available, a verification only unit and an enrollment unit.<br />
Number Of Users<br />
Each Verid unit can store templates on up to 5000 users. Each of the<br />
5000 users can have either one or two fingers registered.<br />
Security Levels - Verid<br />
Each Verid unit can be set into one of 7 security levels. “Levels 1 to 5<br />
(strictest)” - check the fingerprint to differing degrees of accuracy<br />
Additionally, Verid can be set to “PIN Only” (ie no fingerprint checking)<br />
and “Any Fingerprint” (ie the user places a finger on the unit which is<br />
then apparently checked, but will always pass).<br />
Security Levels - User<br />
During the enrollment of each user (and Super user), a security level<br />
can be assigned to that user. The levels that can be assigned to that<br />
user are:<br />
. “Global Setting” - The user will adopt the security setting of the Verid<br />
unit<br />
. “Levels 1 to 5 (Strictest)” - Check the fingerprint to differing degrees<br />
of accuracy<br />
. “Any Fingerprint” - and “PIN Only” can also be assigned to the user<br />
RS485 Network Functions<br />
If a network of Verid units is set up, the following tasks will take place<br />
automatically - normally without any P.C. or user intervention:<br />
. Any users added, deleted or updated will immediately be broadcast<br />
to all other Verid units on the network<br />
. Any new units added to the network will adopt the configuration<br />
(e.g. PIN device and messages) of the other units on the network<br />
. Network address information will be resolved by the Verid units on<br />
the network to avoid duplicate network IDs<br />
Template Management<br />
Once installed, the dedicated RS 485 network will automatically<br />
transfer information on newly enrolled, deleted or updated templates.<br />
Adding new units into the network is also made easy with all new units<br />
automatically adopting the configuration of the other units on the<br />
network. The network architecture is a linear twisted pair, terminated<br />
with 120 Ohm resistors, with no spurs.<br />
Configuration<br />
Verid is supplied in a standard configuration suitable for 26 bit format<br />
Wiegand. These settings can be altered by sending commands via the<br />
RS232 port. The detailed command set is contained in the full Verid<br />
Manual. Alternatively, the configuration can be set using the ‘Verid<br />
Manager’ P.C. software kit., available from TSSI. (Requires a P.C.<br />
running Windows 95 or later).<br />
Technical Specification<br />
Dimensions: 160H x 165W x 60D mm<br />
Power:<br />
10 - 14Vd.c., Max. 500mA<br />
A separate/ancillary power supply will be required for locks etc.<br />
A User’s individual security level will override the global level set<br />
on the Verid unit being used.<br />
Verid Verification<br />
Verid Manager<br />
<strong>Product</strong> Codes<br />
636.002.202<br />
Enrollment Unit. 1 enrollment unit is needed or<br />
each installation, in addition to the LEDs,<br />
enrollment units have an integral LCD display<br />
and control keys. These units enable new users<br />
to be enrolled onto the system. The enrollment<br />
unit performs all the functions of the verification<br />
unit with the added capability of enrolling,<br />
updating and deleting users from its internal<br />
database. This information can then be<br />
extracted via the RS232 port and transferred to<br />
there Verid verification or enrollment units.<br />
Automatic transfer of templates is available via<br />
the integral RS485 network connection.<br />
636.002.203<br />
Verification Unit. Uses LEDs only to guide the<br />
user through the verification process. The Verid<br />
verification unit accepts a PIN from a PIN entry<br />
device. A comparison is then made between<br />
the template from the live finger and the<br />
original template associated with the PIN.<br />
Templates can be stored in Verid or on Track 3<br />
of a magnetic card. If the templates match,<br />
Verid outputs the PIN data. PINs and templates<br />
are loaded via the integral RS232 and RS485<br />
ports.<br />
636.002.204<br />
Verid Manager Software. Windows 95<br />
management software for configuration and<br />
back up of the Verid readers. There is a 3.5 mm<br />
jack connector on the underside of the unit that<br />
provides RS232 communications. Verid<br />
Manager, from TSSI, offers a variety of template<br />
management options including capturing or<br />
writing the complete database, capturing or<br />
writing individual records and storing records in<br />
a PC for back up or transfer to other units.<br />
More details are available in the document<br />
‘Verid Manager User Guide’.<br />
46
Card Accessories<br />
637.001.002<br />
637.001.005 637.001.006<br />
637.001.007 637.001.008<br />
<strong>Product</strong> Codes<br />
637.001.001<br />
Rigid Plastic Card Holder for Swipe Cards. For<br />
Use with Chain or Clip<br />
637.001.022<br />
Soft Plastic Card Holder E.G.. for Prox and ID<br />
Cards. Requires Chain or Clip<br />
637.001.005<br />
Self Adhesive Vinyl Pouch - for Car Windscreens<br />
637.001.006<br />
Locking Clip for rigid and soft card holder and<br />
Cards with Slots<br />
637.001.007<br />
Neck Bead Chain for rigid and soft card holders<br />
and Cards with Slots<br />
637.001.008<br />
Card Slot Punch for Producing Edge Slots for the<br />
locking clip.<br />
Yo Yo-5BK<br />
Yo-Yo Access Control Card Holder<br />
47
Card Bureau Services<br />
Bureau Service<br />
C•<strong>CURE</strong> 800<br />
A bureau service is now available to those<br />
customers who do not wish to produce their<br />
cards in-house. Tyco Safety <strong>Product</strong>s card<br />
production bureau utilises the latest equipment<br />
including image manipulation and digital imaging<br />
software which is updated as technology<br />
progresses. The customer should provide (or the<br />
Tyco Install can arrange for) photographs or<br />
digital images (preferred) to be sent to the<br />
bureau.<br />
Before any order for the cards listed below is<br />
accepted. An order for the card setup charge<br />
must be made. At the same time the customer<br />
must supply all artwork etc. to allow us to<br />
prepare a sample card. Once the customer has<br />
approved this in writing, the order for the card<br />
will be accepted and the cards manufactured.<br />
Set up code<br />
636.001.810<br />
Card Bureau cost for setting up customer specific<br />
artwork. Customer will approve order before<br />
order is manufactured and dispatched. Tyco<br />
Safety <strong>Product</strong>s Letchworth Card Bureau will<br />
liaise the Tyco Installation business regarding<br />
designs and supply.<br />
Mag Stripe Designs<br />
CBP010<br />
Mag stripe card with printing by Tyco Safety<br />
<strong>Product</strong>s card Bureau on the front of the card -<br />
up to three colours, NO PHOTO. The cards<br />
magnetic stripe is UNENCODED. CUSTOMER TO<br />
SUPPLY CARDS<br />
The Tyco Safety <strong>Product</strong>s Bureau will then<br />
provide a specimen card for approval and<br />
complete the order).<br />
After written acceptance cards carrying one or<br />
more technologies can also be encoded prior to<br />
despatch. Special equipment has been installed<br />
for applying clear and holographic overlays to<br />
cards, for high-security applications and where<br />
additional durability is required.<br />
The bureau will store all data and images securely<br />
for retrieval at a later date, should cards need to<br />
be re-isseud. Alternatively, they can be saved in a<br />
number of file formats and sent on to the<br />
customer.<br />
To complete the process the following information<br />
will be required before budget/fixed pricing can<br />
be supplied:<br />
1 Style of card required<br />
2 Customer supplying artwork<br />
3 Number of colours per design<br />
4 How the photographs will be provided:-<br />
- Photograph<br />
- Electronic File<br />
5 Number of sides to be printed<br />
6 Order quantity<br />
The customer must supply a design layout which<br />
meets their requirements, together with any<br />
‘corporate’ design restrictions and requirements.<br />
The bureau will then produce a paper copy of the<br />
layout design and/or a sample card. The<br />
customer must then sign and return a design<br />
approval document prior to the order being<br />
completed.<br />
The stock code numbers covering the card<br />
layouts available can be applied to either a plain<br />
white unencoded mag stripe card (636.001.802)<br />
or the HID Duoprox II (662.001.904). These can<br />
be printed on the front and/or rear face and have<br />
the mag stripe encoded. All of the new part<br />
numbers include the cost of the card. This is not<br />
usually part of a proposal from outside suppliers.<br />
We estimate that out cost will be approximately<br />
20% lower than the suppliers used at present.<br />
CUB011<br />
Mag stripe card with printing by Tyco Safety<br />
<strong>Product</strong> Card Bureau on the front of the card -<br />
with Photo ID. Artwork and photos to be supplied<br />
by te customer. The cards magnetic stripe is<br />
UNENCODED. CUSTOMER TO SUPPLY CARDS.<br />
CUB012<br />
Siteguard format mag stripe card with printing by<br />
Tyco Safety <strong>Product</strong>s Card Bureau on the front of<br />
the card - up to three colours NO PHOTO.<br />
CUSTOMER TO SUPPLY CARDS.<br />
CUB013<br />
Siteguard format mag stripe card with printing by<br />
Tyco Safety <strong>Product</strong>s Card Bureau on the front of<br />
the card - with Photo ID. Artwork and photos to be<br />
supplied by the customer. CUSTOMER TO<br />
SUPPLY CARDS<br />
CBP017<br />
Mag stripe card with a single colour print on the<br />
reverse of the card (return address) above the<br />
UNENCODED Mag Stripe is also included.<br />
CUSTOMER TO SUPPLY CARDS<br />
CUB018<br />
Siteguard format mag stripe card with a single<br />
colour print on the reverse of the card (return<br />
address) above the mag stripe. CUSTOMER TO<br />
SUPPLY CARDS.<br />
CBP019<br />
Mag stripe with printing by Tyco Safety <strong>Product</strong>s.<br />
Card BUREAU on the front of the card - up to<br />
three colours, NO PHOTO. A single colour print<br />
on the reverse of the card (return address)<br />
abovethe UNENCODED mag stripe is also<br />
included. CUSTOMER TO SUPPLY CARDS.<br />
48
Locks<br />
C•<strong>CURE</strong> 800<br />
This section of the Tyco Safety <strong>Product</strong>s Access Control <strong>Catalogue</strong> covers the locks and ancillary items required for most installations. These are by no<br />
means an exhaustive list of the products available, but a selection of the most commonly required parts. More complex designs or requirements may<br />
require direct input from our specialist suppliers. Remember, locks used for access control are not usually designed to provide the degree of physical<br />
security against gross attack that may be required for insurance purposes. Consideration must also be given to fire and Health and Safety aspects of any<br />
installation. This includes for means of escape, access to a secure area for emergencies and also providing sufficient headroom for users. As with all<br />
locking systems, the survey must take account of the doors existing fittings and furniture. The door must fit correctly, have adequate hinges and a suitable,<br />
preferably double action, door closer.<br />
Magnetic Locks<br />
Slimline Brackets<br />
637.008.451<br />
Adams Rite L Bracket for outward opening<br />
doors. For 261 Aluminium Magnets. Double<br />
Magnets Require Two<br />
637.008.452<br />
Z & L Bracket for inward opening doors. For 261<br />
range Aluminium Magnets. Double Magnets<br />
require two.<br />
These are now the most commonly used<br />
access control lock due to their ease of<br />
installation and tolerance to door deterioration.<br />
These locks are by their design - FAIL SAFE<br />
units. This means that they require the power<br />
from the access system to provide a holding<br />
force. When the power is removed the lock<br />
releases. Should there be a total power failure,<br />
cable damage etc, the lock fails in a released<br />
state.<br />
The locks in this section are face to face style.<br />
They hold by means of a coil in the lock<br />
producing a magnetic field, which attracts an<br />
armature plate, which is fitted to the door. The<br />
holding force is purely due to the magnetic field<br />
which is reliant upon the armature being in<br />
direct alignment with the magnetic coil. The<br />
armature is fitted with a minor tolerance allowing<br />
for distortion etc. It is possible however to attack<br />
the door by "springing" the lock to gain entry -<br />
this is especially likely on large doors. As the<br />
lock requires a face to face fitting it is only<br />
suitable for doors that swing in one direction<br />
only. It is essential that these locks are not<br />
installed on the transom of swing through doors<br />
and used as a doorstop as well as the lock.<br />
Options available include status monitoring -<br />
contacts in the lock detect that the door is<br />
closed. There is also a double monitored unit,<br />
which monitors the door status contact and the<br />
holding force of the lock. This ensures that the<br />
lock is providing the level of holding force<br />
expected. Should someone try to defeat the<br />
lock by applying grease to the face plate(s) or<br />
use a plastic layer to create an air-gap between<br />
lock and armature then an alarm output can be<br />
given.<br />
The installation of these locks is quite simple.<br />
They do however require there to be sufficient<br />
room on the door transom or for brackets to be<br />
fitted. On outward opening doors, head height<br />
is lost and either L brackets or a transom bar<br />
can be used. Be aware of Health & Safety<br />
isseus for minimum door opening height. For<br />
inward opening doors, Z&L brackets are<br />
required.<br />
As magnetic locks have no means of providing<br />
a mechanical override it is normal practice to<br />
supply an emergency break glass box adjacent<br />
to the door for means of escape. It is also good<br />
practice to provide at least one door to each<br />
secure area with a means of overriding the<br />
system for emergency entry. This would<br />
normally be achieved by a secure keyswitch<br />
on the unsecure side of the door. This should<br />
be wired into the system in line with the lock<br />
power. This is of course a security risk so it<br />
must be installed in the correct manner.<br />
<strong>Product</strong> Codes<br />
Slimline Maglock - Up to 250Kg Holding<br />
Force<br />
637.008.401<br />
Adams Rite 261-000 non-monitored single<br />
magnet 12 Or 24v dc. (Nominal<br />
480mA@12Vd.c.) Medium duty suitable for<br />
internal doors. Aluminium<br />
637.008.403<br />
Adams Rite 261-200 non-monitored double<br />
magnet 12 Or 24v dc.(Nominal 1 Amp@12Vd.c.)<br />
Medium duty suitable for internal doors.<br />
Aluminium<br />
Standard Maglock - Up to 510Kg Holding<br />
Force<br />
637.008.406<br />
Adams Rite 281-000 non-monitored single<br />
magnet 12 Or 24v dc. (Nominal<br />
480mA@12Vd.c.) Medium duty suitable for<br />
internal doors. Aluminium<br />
Standard Brackets<br />
637.008.453<br />
Adams Rite L bracket for 281 mag lock to be<br />
used on outward opening doors. Double<br />
Magnets require two sets.<br />
637.008.454<br />
Adams Rite Z & L Bracket Set for 281 mag locks<br />
on inward opening doors. Aluminium. Double<br />
Magnets require two sets.<br />
Mortice Maglock & Housing<br />
637.008.405<br />
Adams Rite 262-005 monitored mortice magnet<br />
12 or 24v dc (480mA @ 12V). Medium duty<br />
suitable for internal doors.<br />
637.008.455<br />
Double 2 Metre Transome Housing for 2 Mortice<br />
Magnets - Aluminium<br />
49
Locks and Electric Releases<br />
C•<strong>CURE</strong> 800<br />
There are a wide variety of locks and electric<br />
releases available for access control. In the main,<br />
there are three options available:<br />
• Surface or flush fitting<br />
• Fail safe or Fail secure<br />
• Monitored or unmonitored.<br />
Surface or flush is simply the method<br />
of installing the lock. This must take account of<br />
the aesthetics, security and type of door and<br />
frame.<br />
Fail-safe is a release that allows access when the<br />
power is removed from the operating coil. Fail<br />
safe locks therefore draw power from the access<br />
system when the door is in its closed state.<br />
Fail secure provides a degree of physical<br />
security when the lock has<br />
the power removed. This could be either in its<br />
normal operation or in a total power failure.<br />
Subject to the lock design. This type<br />
of installation offers a means of mechanical<br />
override for escape from the secure side of the<br />
door - handle or if acceptable paddle turn. and a<br />
mechanical override for entry by key. If this is not<br />
available then breakglass and keyswitch may be<br />
required as for the magnetic lock.<br />
<strong>Product</strong> Codes<br />
A34010<br />
Chubb 3R35 Latching Deadlock<br />
637.008.410<br />
Adams Rite 7100-Fail Secure 12 Vdc electric<br />
release (340mA) short face plate for Aluminium<br />
frames. Maximum operational gap (door to<br />
frame) 3mm. Jaw strength up to 900kg<br />
637.008.411<br />
Adams Rite 7113-Fail Secure 12 Vdc electric<br />
release (340mA) narrow face plate for timber<br />
frame or door. Maximum operational gap (door<br />
to frame) 3mm. Jaw strength up to 900kg<br />
637.008.412<br />
Adams Rite 7100-Fail Safe 12 Vdc electric<br />
release (340mA) short face plate for Aluminium<br />
frames. Maximum operational gap (door to<br />
frame) 3mm. Jaw strength up to 900kg<br />
637.008.413<br />
Adams Rite 7113-Fail Safe 12 Vdc electric<br />
release (340mA) narrow face plate for timber<br />
frame or door. Maximum operational gap (door<br />
to frame) 3mm. Jaw strength up to 900kg<br />
618.003.891<br />
A C release to suit Yale 88/89 latch<br />
Shear Locks<br />
These are magnetic locks designed for fitting into<br />
the transom or doorframe. The holding force this<br />
time draws up the armature plate allowing a<br />
locating pin to be put in place from the lock to<br />
the armature. This provides a physical<br />
mechanism against the side shear force applied<br />
to the door when trying to overcome the lock.<br />
These locks can be fitted to swing through doors<br />
but the re-alignment of the door(s) is critical.<br />
<strong>Product</strong> Code<br />
637.008.414<br />
Adams Rite Armlock 1354 Mini Electro-Shear<br />
magnet mortice fitting - 12 or 24Vd.c.. Up to<br />
1500kg holding force. Requires 1.5 Amps Pull In<br />
@ 12Vd.c. (Quiescent 500mA @ 12Vd.c.).<br />
Door Loops<br />
Where locks or releases are fitted into the controlled door and require electrical/monitoring connection, a door loop is required to allow a flexible connection<br />
to be made from the door frame to the moving leaf.<br />
A33305<br />
A33306<br />
<strong>Product</strong> Codes<br />
A33305<br />
Concealed Door Loop<br />
A33306<br />
Surface Door Loop Arm Conduit<br />
50
Ancillaries<br />
Breakglass Boxes<br />
C•<strong>CURE</strong> 800<br />
636.008.052.A<br />
Key Switch<br />
636.008.051.A<br />
These items are wired in series with any fail safe<br />
lock (power required to secure the door) and its<br />
power supply feed and must be connected as<br />
the last item in the circuit before the lock itself.<br />
This means that the lock power can be cut off<br />
to provide a means of escape from the<br />
controlled area. In some circumstances, a<br />
breakglass may be required on the unsecure<br />
side to give access into the secure area for<br />
emergency purposes - lift lobbies etc. The latter<br />
is a security risk and the breakglass and door<br />
should be monitored to generate a door forced<br />
alarm as soon as the glass is broken.<br />
When a door is fitted with access control, using<br />
a lock that does not offer a means of override<br />
from the unsecure side in the event of an<br />
emergency, it is advisable to install a key switch<br />
at one entry point to each secure area. This will<br />
operate in a similar manner to the emergency<br />
break glass detailed above, in that it removes<br />
power from the lock (fail-safe). It is however a<br />
little more secure in that unless it is tampered<br />
with a key is required to operate the override<br />
facility. The door should of course be monitored<br />
Ordering Information<br />
<strong>Product</strong> Codes Contacts Brand Colour<br />
636.008.051.A 1 ADT White<br />
636.008.052.A 1 ADT Green<br />
636.008.055.A 2 ADT Green<br />
636.008.052.U 1 Unbranded Green<br />
636.008.055.U 2 Unbranded Green<br />
515.001.025 Pack of 5 Clear replacement<br />
glass<br />
and generate a door forced indication when the<br />
door is opened via the key switch.<br />
<strong>Product</strong> Codes<br />
636.008.064<br />
Two Position (90 Degree) Key switch on UK<br />
Single Gang Stainless Steel Faceplate. Key<br />
Removal In Both Positions. TOK Barrel. Single<br />
Pole Changeover.<br />
636.008.066<br />
Satin Anodised Aluminum Surface Box<br />
Egress Buttons<br />
636.008.053 636.008.060 636.008.062<br />
This section offers a wide range of devices, which<br />
allow an access-controlled door to be opened in<br />
an authorised manner. Standard methods of<br />
egress mechanical handle etc do not normally<br />
provide a signal to the central control equipment.<br />
A door forced indication would therefore be<br />
generated if monitoring of the access doors were<br />
required. Also if magnetic lock or similar are used,<br />
a safe means of release is required. Listed below<br />
are standard egress buttons, for both low and<br />
high traffic use, contact egress buttons and also<br />
an egress PIR. The last two items offer a "contact"<br />
free load maintenance means of egress. The<br />
egress PIR can be sited and adjusted to provide<br />
a door release signal only in the event a person<br />
moving into the vicinity of the door.<br />
<strong>Product</strong> Codes<br />
636.008.053<br />
Surface Mount Egress Button with White Button<br />
Engraved (Door Release) Low Traffic<br />
636.008.056<br />
Flush Single Gang Stainless Steel Push Button<br />
with "Press To Exit" Engraved In Green. Normally<br />
Open Contacts<br />
636.008.057<br />
Narrow Style Flush Single Gang Stainless Steel<br />
Push Button with "Press For Exit" Engraved In<br />
Green. Normally Open Contacts<br />
636.008.058<br />
Narrow Style Flush Single Gang Stainless Steel<br />
Plate with Green Plastic Illuminated Button. Single<br />
Pole Changeover. Requires 12Vd.c. for The Lamp<br />
636.008.060<br />
Large Green Dome Push Button with Flush Single<br />
Gang Stainless Steel Plate and "Press For Exit"<br />
Engraved In Green. Single Pole Changeover<br />
636.008.062<br />
High Impact High Traffic IP67 Push Button on<br />
Green (Matches Break Glass) Single Gang<br />
Faceplate and "Press To Exit" Printing. Single Pole<br />
Changeover<br />
678.001.003<br />
Momentary White Egress Button To Fit UK Single<br />
Gang Back Box. Thorn Branded<br />
A33308<br />
636.008.067 636.008.066<br />
White Surface Exit Button<br />
636.008.067<br />
TS4 touch switch. No moving parts, therefore<br />
reduced maintenance.<br />
636.008.063<br />
Green Surface Mount Box for 636.008.062<br />
(SGA-EB7)<br />
636.008.066 Satin anodised aluminium<br />
surface box.<br />
51
T-Rex Smart Exit Detector<br />
C•<strong>CURE</strong> 800<br />
The smart exit detector. The T.Rex provides a<br />
complete solution to exit detection and door<br />
surveillance for access control applications.<br />
Outstanding innovations such as X-Y Targeting<br />
TM and DSP implementation make the T.Rex<br />
the fastest and most reliable exit detector on<br />
the market.<br />
X-Y TargetingTM targets a specific area of<br />
detection.<br />
While some exit detectors on the market offer<br />
adjustments of the detection pattern with masking<br />
or horizontal alignment, the T.Rex is the first<br />
detector to offer vertical detection using two<br />
adjustable louvres located in the detection<br />
chamber. The installer “trims” the detection area<br />
by adjusting these louvres from 90° down to a<br />
minute 5°. Horizontal adjustment is provided by<br />
rotation of the lens.<br />
Added security: These two adjustments allow the<br />
installer to mount the detector so that the<br />
detection area will not “hit” the floor along the<br />
doorjamb. This exclusive feature defeats attempts<br />
to circumvent door supervision by sliding objects<br />
underneath the door. Such objects would be<br />
detected by sensors mounted in a traditional way.<br />
DSP (Digital Signal Processing) prevents “Door<br />
Forced Open” alarms. Kantech’s T.Rex utilises<br />
infrared detection coupled with DSP sampling<br />
specifically designed for access control<br />
applications. There is a substantial operational<br />
difference between a common infrared intrusion<br />
motion detector and the T.Rex. An intrusion<br />
detector operates at low sensitivity levels and is<br />
looking for the positive presence of a human. An<br />
exit detector must detect the extremely fast<br />
movements of a hand (the target) about to push<br />
the door or turn the door handle. Contrary to<br />
intrusion applications, a failure to detect in an exit<br />
application will actually cause a “Door Forced<br />
Open” alarm.<br />
Detector Features<br />
. New concept in access control exit detection<br />
. Zone of detection easily adjustable with pinpoint<br />
accuracy.<br />
. Unlocks or shunts door automatically<br />
. Hands free! No buttons to push!<br />
. Integrated 90dB local door alarm<br />
sounder independently controlled by access<br />
panel<br />
. 2-relay model available.<br />
Specifications T.Rex<br />
Detector type<br />
Passive infrared<br />
Filter technology<br />
Digital Signal Processing (DSP)<br />
Detector Lens<br />
Curtain type Fresnel lens<br />
Detection Range One hand: 3m (10’)/Whole body:6m (20’)<br />
Power consumption<br />
12-28VDC, 50mA<br />
Piezo buzzer<br />
90dB at 28V, 5-28VDC, 20mA<br />
Main relay contacts<br />
SPDT, A max, at 30 VDC max<br />
Main relay timer<br />
Adjustable, 1/2 to 60 sec.<br />
Main relay recycle time Fixed 3/4 sec. off<br />
Tamper switch<br />
N.C. 100ma max at 30 VDC max<br />
Dimensions (H-W-D)cm 19.0 x 4.5 x 4.75<br />
Dimensions (H-W-D)in 7.13 x 1.75 x 1.88<br />
Indicator light (LED)<br />
Red/Green<br />
Certifications<br />
UL 294, CE, FCC<br />
<strong>Product</strong> Code<br />
T.Rex XL<br />
T.Rex Smark Exit Detector with 90DB piezo sounder<br />
T. Rex Exit Detector PB-EXIT Exit Button<br />
Tamper switch N.C.<br />
Function selection jumpers: Latch,<br />
fast/slow detection, LED disable<br />
Infrared sensor encased in an insulation chamber.r The signal<br />
is subsequently audited by the on-board computer and filtered<br />
using digital signal processing technology (DSP) with automatic<br />
environmental compensation.<br />
Main relay<br />
Integrated 90dB piezo for door alarm.<br />
Controlled by remote panel or through onboard<br />
relay (5-28VDC)<br />
Lock control relay<br />
Lock control relay and<br />
main relay terminals<br />
Main relay timer jumpers 16-step digital<br />
timer from 0.5 to 60 seconds<br />
Power terminals and tamper output<br />
On-board computer<br />
X-Y Targetting TM using two adjustable<br />
louvres to target a specific area of<br />
detection such as door handle or panic bar.<br />
T.REX-XL2 model shown<br />
52
Post Sales Support and Training<br />
Technical Support Hours and Phone Numbers<br />
Normal Support Hours<br />
Monday through Friday : 9.00 a.m. - 5.00p.m. (except Public Holidays)<br />
C•<strong>CURE</strong> 800<br />
Technical support personnel<br />
UK, Ireland, and other English speaking support Harjinder Flora +441932743288 hflora@tycoint.com<br />
UK, Ireland, and other English speaking support Mick Coleman +441932743288 mscoleman@tycoint.com<br />
UK, Ireland, and other English speaking support Seu Wong +441932743028 seuwong@tycoint.com<br />
France, Belgium and French Speaking countries Roger Decarpentry +33140962494 rdecarpentry@tycoint.com<br />
France, Belgium and French Speaking countries Eric Peron +33140962589 eperon@tycoint.com<br />
Italy, Spain Massimo Lamonaca +390256607227 mlamonaca@tycoint.com<br />
Hungary and Eastern Europe Miklos Holbis +3162109457 mholbis@tycoint.com<br />
Germany and Central Europe Olaf Gutjahr +492102431246 ogutjahr@tycoint.com<br />
Germany and Central Europe Uwe Wingerath +4921027708726 uwingerath@tycoint.com<br />
Middle East Tony Moughames +961985425/6/7 tonym@sensormatic-mideast.com<br />
If you have difficulty obtaining support, please contact:<br />
John Murphy, Technical <strong>Product</strong> Manager - Access Control<br />
tel: +44 1932 743028, e-mail; johnmurphy2@tycoint.com<br />
Software Support Agreements (SSA)<br />
Tyco safety <strong>Product</strong>s - C•<strong>CURE</strong> 800 Software Support Agreement (SSA)<br />
Standard Service is our standard coverage option. It provides telephone<br />
support and assistance from our Customer Support centres during normal support<br />
hours<br />
(M-F, 9.00am - 5.00PM) as well as - software and firmware maintenance updates.<br />
Standard Service also provide, at no additional chrage, both software and<br />
maintennace release updates, normally targeted to resolve software code conflicts,<br />
and software enhancement release updates which target software features development.<br />
Tyco Safety <strong>Product</strong>s Technical Training Courses<br />
C•<strong>CURE</strong> 800 Courses are provided both as scheduled quarterly courses and as special on-demand courses (minimum<br />
6 people). For registration details and course availability, as well as special course requests, please contact:<br />
Dave Walton: Tel: 0114 278 8450 e-mail; dawalton@tycoint.com<br />
C•<strong>CURE</strong> 800 Technical Training Modules<br />
Module 1<br />
Duration<br />
Prerequisites<br />
C•<strong>CURE</strong> 800 Basic Configuration<br />
2 days<br />
Understanding of basic Access Control concepts<br />
Background with handling low voltage electronic systems<br />
Familiarity with using Windows NT/2000/XP Operating Systems<br />
Familiarity with Windows Networking using TCP/IP<br />
Objectives The objective of this course is to give the student a good grounding in core C•<strong>CURE</strong> 800<br />
installation and configuration, concentrating on directly connected Apc/8x and Apc/L<br />
controllers.<br />
Topics Covered:<br />
. C•<strong>CURE</strong> 800 Concept and Feature<br />
. Apc Family hardware presentation and wiring<br />
. Designing the C•<strong>CURE</strong> 800 Installation<br />
. Installing C•<strong>CURE</strong> 800 Server and Client Software<br />
. C•<strong>CURE</strong> 800 Core configuration<br />
. C•<strong>CURE</strong> 800 diagnostics and reports<br />
. C•<strong>CURE</strong> ID<br />
53
Post Sales Support and Training<br />
Module 2<br />
C•<strong>CURE</strong> 800 Basic Configuration<br />
Duration<br />
2 days<br />
Pre-requisites Successful completion of module 1<br />
C•<strong>CURE</strong> 800<br />
Objectives<br />
connections.<br />
Topics Covered:<br />
This module builds on what was learned in module 1 by looking at the networked controller<br />
capabilities of C•<strong>CURE</strong> 800 with the addition of remote dial-up Apc family<br />
. Network Connected device<br />
. Apc via Lantronix Terminal Servers<br />
. iSTAR Network Controller<br />
. Apc vial Dial-Up Modern connection<br />
Module 3 C•<strong>CURE</strong> 800 Advanced Features 1<br />
Duration<br />
1 day<br />
Prerequisites<br />
Objectives<br />
Topics Covered:<br />
Successful completion of Modules 1 and 2 or old C•<strong>CURE</strong> 800 Stagged 1 course<br />
Modules 1 and 2 coversthe requirements for the majority of small to medium system<br />
requirements. This modules looks at some of the more advanced features of C•<strong>CURE</strong> 800<br />
. Database Partitioning<br />
. Apc and iSTAR Intrusion Zones<br />
. CCTV Matrix Interface<br />
. Netvue Option: Interface to Intellex<br />
. Elevator Control<br />
Module 4 C•<strong>CURE</strong> 800 Advanced Features 2<br />
Duration<br />
1 day<br />
Pre-requisites<br />
Objectives<br />
Topics Covered:<br />
Users must have completed Modules 1,2 and 3 or the old C•<strong>CURE</strong> Stage 1 Course.<br />
To cover the advanced cared import/export, ODBC and Automated Import capabilities of<br />
C•<strong>CURE</strong> 800.<br />
. Card Import/Export<br />
. Accessing the C•<strong>CURE</strong> 800 tables using ODBC<br />
. Automated Import<br />
. Advanced Reporting using ODBC<br />
. Enhanced reporting (v8.0)<br />
Module 5<br />
Duration<br />
C•<strong>CURE</strong> 800 Options<br />
2 day<br />
Pre-requisites Users must have completed Modules 1 to 4 or the old C•<strong>CURE</strong> Stage 1 and Module 4.<br />
Objectives<br />
covered<br />
Topics Covered:<br />
This module covers training on the optional features of C•<strong>CURE</strong>800 (except Netvue,<br />
in Module 3), Guard Tour, E-Mail/Paging, Central Monitoring, Escorted Access.<br />
. Guard Tour<br />
. E-mail/Paging on Event<br />
. Central Monitoring<br />
. Escorted Access<br />
. General Bi-directional Serial Interface<br />
. Areas and Anti-Passback<br />
. Occupancy restrictions and n-Man Rule (v.80)<br />
. Enhanced Password protection (v8.0)<br />
. Area Lockout (v8.0)<br />
54
Post Sales Support and Training<br />
Module 6<br />
Duration<br />
C•<strong>CURE</strong> 800 New Features Update<br />
1 or 2 days (depending on features added)<br />
C•<strong>CURE</strong> 800<br />
Prerequisites Attendees must, as a minimum, have completed Modules 1 and 2 or the old C•<strong>CURE</strong> 800<br />
Stage 1. It is recommended that attendees have attended Modules 3 and 4 also.<br />
Objectives<br />
Topics Covered:<br />
Non-Scheduled Courses<br />
Redundant C•<strong>CURE</strong> 800<br />
The objective of this course is to update attendees who have previously attended courses<br />
to get updated on the new features of a version release.<br />
. Topics will change as new versions of C•<strong>CURE</strong> 800 are rleased.<br />
Details of this module will be announced close to the launch of a product.<br />
Duration<br />
Pre-requisites<br />
2 days<br />
Familiarity with using Windows NT or 2000 server Operating Systems<br />
Familiarity wth Windows Networking using TPC/IP<br />
Customers must have completed modules 1 to 5. If their certification is for an older version<br />
of C•<strong>CURE</strong>800, then they also must attend Module 6, fornew feature updating.<br />
Objectives<br />
The objective of this course is to instruct attendees in the installation and configuration of<br />
the Dual redundant C•<strong>CURE</strong> 800, using Legato Co-Standby Server.<br />
NOTE:<br />
This course is available on request only to Customers who have purchased this product. Contact John Murphy for<br />
further information (johnmurphy2@tycoint.com).<br />
55
Technical Documentation<br />
The following docuemnts are available in .pdf format at www.swhouse.com<br />
apC/8X Technical Manual<br />
apC/L Technical Manual<br />
C•<strong>CURE</strong> 800<br />
C•<strong>CURE</strong> 1Plus UltraStation User Guide<br />
C•<strong>CURE</strong> 1Plus UltraStation User Guide<br />
C•<strong>CURE</strong> 1Plus Ultravision User Guide<br />
C•<strong>CURE</strong> 800 Administrator’s Getting Started Guide<br />
C•<strong>CURE</strong> 800 Administrator’s Non-hardware Configuraion Guide<br />
C•<strong>CURE</strong> 800 Administrators Personnel Configuration Guide<br />
C•<strong>CURE</strong> 800 Administrator’s reports and System Maintenance Guide<br />
C•<strong>CURE</strong> 800 Installation Guide<br />
Configuration Guide for Obtaining data from the C•<strong>CURE</strong> database<br />
Hardware Installation Guide<br />
Monitoring Station Guide<br />
C•<strong>CURE</strong> Vision One User’s Guide<br />
C•<strong>CURE</strong> Vsion User’s Guide<br />
iSTAR Configuration Guide<br />
iSTAR Hardware Installation Guide<br />
56
BSIA INFORMATION<br />
USERS’ BASIC GUIDE TO ACCESS CONTROL<br />
THE OUTCOME OF THE RISK ASSESSMENT OF YOUR PREMISES WILL DETERMINE THE LEVEL OF SECURITY<br />
YOU REQUIRE AND IN TURN INFLUENCE YOUR CHOICE OF ACCESS CONTROL SYSTEM TO BE USED<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
RISK ASSESSMENT<br />
APPEARANCE<br />
EASE OF ACCESS<br />
ERGONOMICS<br />
TRAINING<br />
SYSTEM<br />
MANAGEMENT<br />
DATABASE<br />
MANAGEMENT<br />
SYSTEM<br />
MAINTENANCE<br />
INTERACTION<br />
COMPLIANCE<br />
OBJECTIVES<br />
Carry out a comprehensive risk assessment o your premises and<br />
decide the level of security you require before planning your<br />
Access Control system. Take into account any special features<br />
you require.<br />
Your Access Control system is often the first impression made on<br />
visitors to your premises. Consider environmental aspects of the<br />
aesthetics of your building.<br />
Examine the layout of your system. Do your entry and exit procedures<br />
allow legitimate users to pass without undue effort and<br />
delay?<br />
Consider the physical aspects. Can PIN pads, card and token<br />
readers be accessed without difficulty? Can displays be readily<br />
observed?<br />
Are your staff fully aware of the role and operation of your Access<br />
Control System? Your Installer should provide adequate system<br />
training.<br />
The integrity of your Access control system must be preserved.<br />
Are you fully conversant with correct system management and<br />
administration procedures? Requires well defined written<br />
procedures for your installers.<br />
Are you aware of the legal implications concerning personal data<br />
held on your database?<br />
Your installer should supply all relevant system documentation e.g.<br />
log books and service schedules.<br />
Are you aware of the access required on system breakdown?<br />
Do you have a satisfactory system maintenance agreement in<br />
place.<br />
Your Access Control system may supplement other security<br />
measures. Consider system compatibility.<br />
Are you and your company compliant with:<br />
The Disabilities Act (1996)<br />
The Data Protection Act (1998)<br />
The Human Rights Act (1998)<br />
Are your desired security objectives being satisfied? If necessary,<br />
carryout a further risk assessment and address any shortcomings.<br />
ACCESS CONTROL IS ONLY ONE IMPORTANT ELEMENT FOR YOUR OVERALL SECURITY SYSTEM<br />
57
BSIA INFORMATION<br />
COURTESY OF BSIA ACCESS CONTROL SECTION<br />
BSIA BSEN50133-1 ELECTROMAGNETIC<br />
SECURITY EXAMPLE SECURITY DOORS LOCKS READER<br />
LEVEL CLASSIFICATION TECHNOLOGIES<br />
TOKEN<br />
HOLLOW<br />
CORE<br />
COMMON ROOM<br />
MEETING ROOM<br />
1<br />
SOFTWOOD<br />
1-A<br />
2-A<br />
UNIQUE<br />
PIN CODE<br />
SOLENOID LATCH<br />
MAGLOCK<br />
1-B<br />
OFFICE DOOR<br />
2<br />
ELECTRIC STRIKES<br />
STEEL<br />
HARDWOOD<br />
BUILDING MAIN<br />
ENTRANCE,<br />
(MANNED)<br />
SOLENOID HANDLE<br />
SOLENOID LATCH<br />
2-B<br />
3<br />
PIN CODE<br />
AND<br />
TOKEN<br />
MOTOR LOCK<br />
3-B<br />
BUILDING<br />
MAIN ENTRANCE,<br />
(UNMANNED)<br />
EXTERNAL<br />
WAREHOUSE DOOR<br />
REAR ENTRANCE,<br />
APARTMENT<br />
BLOCK<br />
4<br />
NOTE: SECURITY CLASSIFICATION OF GLASS DOORS IS NOT GIVEN HERE. REFERENCE SHOULD BE MADE TO THE RELEVANT BRITISH STANDARD<br />
58
Standard AutoCAD Symbols<br />
C•<strong>CURE</strong> 800<br />
Standard AutoCAD Symbols<br />
Tyco Safety <strong>Product</strong>s now has an IntraNet site devoted<br />
to users of AutoCAD Design Packages for electronic<br />
and electrical systems.<br />
The site has been set up with a view to utilising a<br />
common approach to AutoCAD output for drawing<br />
offices using Tyco Safety <strong>Product</strong>s products and systems.<br />
Initially this site includes Standard Symbols for Tyco<br />
Symbol Name<br />
ACAMERA.dwg<br />
Camcorder<br />
Symbol Name<br />
ADOOR.dwg<br />
Single Leaf Door<br />
MX Technology & MX-Graph, Fire and Access<br />
<strong>Product</strong>s and also Diagrams for many Tyco Safety<br />
<strong>Product</strong>s products supplied from the UK, this will be<br />
expanded to include all Tyco Safety <strong>Product</strong>s products.<br />
Please encourage your CAD operators to visit this<br />
website. Even if you're business doesn't use all these<br />
products many of the symbols, schematics and<br />
Symbol Name<br />
ADCKR.dwg<br />
Combined Magstripe Reader<br />
and Keypad<br />
Symbol Name<br />
ADOTM.dwg<br />
Dot Matrix Printer<br />
drawings may be adapted quickly and easily for other<br />
products.<br />
If you require any further CAD information, please<br />
visit our website at www.tsp.help.com or contact the<br />
<strong>Product</strong> Management Helpdesk on 01932 743 327.<br />
Symbol Name<br />
ADONGLE.dwg<br />
Software Dongle<br />
Symbol Name<br />
AEB.dwg<br />
Egress Button<br />
Symbol Name<br />
AEBG.dwg<br />
Emergency Breakglass Box<br />
Symbol Name<br />
AECC.dwg<br />
Ethernet Comms Convertor<br />
Symbol Name<br />
AEGRESS.dwg<br />
Request to Exit<br />
Symbol Name<br />
AEXPANDER8.dwg<br />
8 Port Expander for PC<br />
Symbol Name<br />
AIAC.dwg<br />
Intelligent Access Controller<br />
Symbol Name<br />
AIDPRIN.dwg<br />
I.D. Badge Printer<br />
Symbol Name<br />
AIOC.dwg<br />
Input Output Controller<br />
Symbol Name<br />
AKEYPAD.dwg<br />
Keypad<br />
Symbol Name<br />
AKEYSWITCH.dwg<br />
Lock Override Security<br />
Keyswitch<br />
Symbol Name<br />
AMAGLOCK.dwg<br />
Single Maglock<br />
Symbol Name<br />
AMDUI.dwg<br />
Multi-Drop Universal Interface<br />
(MDUI)<br />
Symbol Name<br />
AMODEM.dwg<br />
Modem<br />
Symbol Name<br />
AMRRDR.dwg<br />
Standard Mag Stripe Reader<br />
Symbol Name<br />
AMULLION.dwg<br />
Mullion Style Proximity Reader<br />
Symbol Name<br />
APRINTER.dwg<br />
Laserjet Report Printer<br />
Symbol Name<br />
APWR_4.dwg<br />
Transformer 12 Volt Supply<br />
PWR-4<br />
Symbol Name<br />
ARS232.dwg<br />
RS232 to 422 Convertor (DVR)<br />
Symbol Name<br />
ASN2RDR.dwg<br />
SN2 Mag Stripe Reader<br />
Symbol Name<br />
AVALUEPROX.dwg<br />
Value Prox Reader<br />
Symbol Name<br />
AWALLSW.dwg<br />
Wallswitch Style Proximity<br />
Reader<br />
Symbol Name<br />
AERELEASE.dwg<br />
Electric Release<br />
Symbol Name<br />
AKPADINT.dwg<br />
Keypad Interface<br />
Symbol Name<br />
AWORKSTATION.dwg<br />
PC<br />
Symbol Name<br />
AHUB.dwg<br />
Hub<br />
59
Glossary of Terms<br />
Access Group Permission programmed into the access control system to<br />
allow a cardholder to enter certain doors at specified times.<br />
Active Card An access control proximity card, which is powered by a battery<br />
within the tag or keyfob. Be aware that batteries have a limited life span<br />
and in most cases cannot be replaced - hence the customer will need to<br />
budget for replacement within the life expectancy of the system.<br />
Anti-Pass Back (APB) is a facility where card readers are programmed as<br />
IN or OUT of a controlled area. Cardholders can enter and area BUT the<br />
card cannot be used at any other IN reader until the card is “seen” by the<br />
system to leave the area. This stops duplicate use of a card at controlled<br />
points.<br />
Asset Tagging Usually managed by active tags and long range<br />
readers/door loops. Asset tagging provides tags, which are suitable for<br />
fixing to items such as laptops, projectors etc. Tags can be static (for fixed<br />
location items - works of art) or portable. Some have additional features<br />
such as tamper, so that the tag cannot be removed whist within the secure<br />
area before the item is taken off site.<br />
Barcode Low cost and low security means of providing access control.<br />
Commonly seen in libraries,. Two methods of barcode are available - open<br />
(as seen in library books) which can be copied and reproduced giving no<br />
security at all and Obscure, which has a panel over the barcode stopping<br />
copying.<br />
Biometric Reader Uses a part of the human body to identify the user -<br />
fingerprint retina scanner etc. Most give a Wiegand output and can be<br />
integrated with our systems subject to test.<br />
Card Number<br />
This is the internal encoded number - as read by the system<br />
Cashless vending A third party supplied system that allows the employee<br />
to use their access control card to purchase lunch, coffee etc. Smart cards<br />
are now being promoted for this purpose. Older systems use track 3 of the<br />
magstripe - only high output mag-stripe tape is accepted by some suppliers<br />
of cashless vending i.e. Girovend.<br />
Clock & Data A card format usually associated with magstripe. This can<br />
however be reproduced by proximity and other reader types.<br />
Coercivity This is the term for the resilience of a magstripe. Standard<br />
access control cards are Hi Co whist Bankcards are usually Lo Co.<br />
Domain software Excelsior’s software package allowing up to 8 networks<br />
to be controlled from one PC. The main advantage of using Domain would<br />
be the use of names for card holders, doors, readers, time zones etc AND<br />
the archiving of al transactions for historical and audit reporting of who went<br />
where and when etc.<br />
Dongle Provided with SGA & Domain software to stop software from being<br />
duplicated for use on other sites.<br />
Door Forced this is an alarm generated by the access system when the<br />
door is opened by unauthorised means break glass box, door override<br />
switch or forced entry. Door must be fitted with a monitor contact.<br />
Door Held Open Alarm generated when an access controlled door is<br />
wedged in the open position after being opened by authorised means. Door<br />
must be fitted with a door contact. Some systems offer local alarm feature<br />
prior to a full alarm at a central location.<br />
Door Loop (reader) This is a cable placed around the doorframe, within the<br />
floor or ceiling to create a larger aerial for a proximity reader. Used for<br />
Hands free access and/or asset tagging.<br />
doors hinged edge to transfer power and monitoring to a lock or electric<br />
release.<br />
Duress Code/PIN By changing the PIN code used by the authorised person<br />
to enter the site. An alarm may be generated at a central location identifying<br />
that the user has gained access whilst under duress. Access at the<br />
door is gained without any local alarm being generated.<br />
Ethernet The most popular standard for networking information technology<br />
equipment. Devices are addressed using TCP/IP protocol.<br />
ECC Ethernet Comms Convertor. Used by SGA to connect a network of<br />
controllers to the central PC via either a dedicated LAN or customers<br />
LAN/WAN. The ECC provides the RS422 protocol required for the SGA<br />
comms line.<br />
Excelsior Tyco manufactured access control system. Can be managed by<br />
either hand held programmer or Domain software. Up to 8,000 cardholders<br />
and from 1 to 1,008 readers. Controllers can be connected by hard-wired<br />
connection, fibre, LAN/WAN or dial-up/dedicated telephone line.<br />
Fail-Safe Term for a lock that requires power to lock - power fail releases<br />
the door. Not suitable for perimeter doors. Ideal for fire exit routes as a fire<br />
alarm input and breakglass box can release the door to meet fire officers<br />
requirements. All face to face mag locks are fail safe. Not suitable for very<br />
secure areas.<br />
Fail-Secure Term for a lock that requires power to operate and allow the<br />
door to be opened. Motor locks and solenoid bolts are typical examples.<br />
Mechanical override is required for means of escape to meet the fire officer’s<br />
requirements.<br />
Graphics Available on SGA. Customers site drawing are either produced<br />
or taken from CAD file. SGA uses bitmap files for Graphic maps - which can<br />
be site photos etc. Icons can then be added for monitored/controlled points,<br />
which are animated to show their status.<br />
Hall Effect Monitoring built in to some magnetic locks to ensure that the<br />
holding force is up to the specified levels. Provides monitoring to overcome<br />
the typical methods of reducing holding force - grease, film etc - making<br />
forced entry much easier.<br />
Hands Free The use of long range readers/Door loops with active tags to<br />
monitor the movement of personnel and assets.<br />
Hi Co Type of magnetic stripe tape - see Coercivity<br />
IAC Intelligent Access Controller for SGA. Supports two card readers (with<br />
or without keypads) and all necessary inputs/outputs for monitoring etc.<br />
Auxiliary inputs and outputs for local devices are also provided. The controller<br />
is boxed with power supply and tamper feature as standard.<br />
Controller will support 12,000 or 44,000 cardholders.<br />
IOC Input Output controller for SGA. Provides supervised input monitoring<br />
and clean contact outputs for local alarm management of non-access control<br />
devices.<br />
ioPass Tyco manufactured standalone proximity access control system.<br />
Supports up to 5,000 card users. Full compatibility with ioProx readers.<br />
ioProx Tyco manufactured range of proximity cards and readers. Can be<br />
used with SGA and with correct firmware Excelsior. Readers are formatted<br />
and the correct items must be ordered. Unique format for ADT/Tyco businesses.<br />
Door Loop (for lock) Flexible conduit either surface or concealed at the<br />
60
Glossary of Terms<br />
ISO Cards A card, which meets the dimension requirements for credit<br />
cards. Used for Photo ID printing etc. Available for proximity technologies.<br />
Keyfob<br />
Proximity tag supplied in a form that can be put on to a key ring.<br />
LAN Local Area Network. An IT data communications network for a local<br />
geographical area. This may be within one building or a cluster of buildings<br />
on a site/campus.<br />
MiFare Smart card chip which can be used for access control. Each chip<br />
has a unique number, which can be read by an access control system - or a<br />
sector of memory within the chip can be programmed with an access control<br />
number for use by the system.<br />
Monitored Access control door or similar that has a contact fitted to it to<br />
show its position/status. Contact can be either magnetic or built in to the<br />
lock/release - separate magnetic contact is preferred.<br />
Magstripe Contact form of access control - the magstripe is run past read<br />
heads within the reader. Low to medium security as the cards can be duplicated.<br />
MDUI Multi Drop Universal Interface. Used with SGA to convert/split or<br />
boost a comms line signal. Available in two forms will support RS232,422 &<br />
485.<br />
Modem A device used to convert data (usually RS232) into an analogue<br />
format for transmission over telephone lines - and then converts back again.<br />
One Modem required at each end of line.<br />
Parallel port<br />
Glossary of Terms for Access Control (cont’d)<br />
Required for each printer to be connected to a PC.<br />
Passive Card A proximity device, which is powered once the card/tag<br />
enters the proximity reader field. The is no on-board battery - therefore read<br />
ranges are reduced BUT there is no battery to replace.<br />
Photo ID Adding a photograph and printing other details onto an ISO card.<br />
This can include customer’s company logo etc.<br />
RS485 Standard protocol for Excelsior and can be used by SGA via MDUI.<br />
Requires one pair cable for transmit/receive up to 1200m (1,600 for<br />
Excelsior using Belden 9207). More tolerant to noise than RS422.<br />
RTE Request to Exit. Push button or PIR device that releases the door.<br />
SGA Siteguard Access. Tyco manufactured PC based access control system,<br />
which supports up to 100,000 card holders and 3,000 + readers. The<br />
system can support multiple reader technologies on one system via hard<br />
wired networks, LAN/Wan or dedicated or dial-up telephone lines. Systems<br />
can have multiple PC connections for system management.<br />
Serial port RS232 port usually found on a PC - required for each hard<br />
wired comms lines for SGA & Excelsior.<br />
Shear lock A magnetic lock that is fitted into the transom of the door<br />
enabling the door to swing through. Therefore door alignment on closing is<br />
critical. When locked the lock has shear pins, which fit into that armature to<br />
increase the holding force.<br />
Site Code Part of the card number which can be specific to that site or<br />
customer. Used by Excelsior it is important that site codes are recorded so<br />
that additional cards are supplied with the correct code.<br />
Smart Card ISO style card, which contains a microprocessor and memory.<br />
Card can be used to store data for access control and third party applications<br />
- cashless vending etc.<br />
Suppression Required for mains, telephone lines and data runs that are<br />
between buildings.<br />
T&A Time & Attendance. Record employees’ on/off site time and can link<br />
to payroll systems. Should be kept separate from the access control system<br />
- card compatibility only is the best solution.<br />
TCP/IP Transmission Control Protocol/Internet Protocol. A layered set of<br />
protocols that allows sharing of applications among PC, workstations and<br />
network controllers (ECC).<br />
PIN Personal Identification Number. Used with keypads - should be considered<br />
for use in addition to any reader technology at the perimeter of a site<br />
to reduced the risk of lost cards being found and used by unauthorised person(s).<br />
PIR Passive Infra Red. A technology, which uses the bodies, heat to<br />
detect presence and then generate a signal. Can be used for hands free<br />
egress control - t.REX. Note any heat sources can detected by a PIR.<br />
Protocol Convertor A device used to change data formats - from a PCs<br />
serial port (RS232) to that required by the controller communications port<br />
(RS422/485 for SAG & RS485 for Excelsior).<br />
Proximity<br />
Release<br />
Rim Release<br />
Yale 88).<br />
Card/reader technology which is contactless.<br />
Electrically operated keep for either a mortice or latch lock.<br />
Surface mounted door release used with rim locks (like the<br />
RLC Remote Line Controller. Used with SGA to manage a remote site with<br />
up to 8 IACs. The central PC with require a modem and dedicated dial up to<br />
telephone line for communication.<br />
RS232 Industries most standard form of serial interface. All PC serial ports<br />
transmit RS232. When using fibre drivers - transmit RS232 and then convert<br />
at the remote location. Without drivers, RS232 has a very short transmission<br />
distance - approx. 15m.<br />
RS422 Standard comms protocol for SGA. Requires two pairs - transmit &<br />
receive. This format extend the communications line up to approx. 1,200m.<br />
Tag A proximity access control device - usually of the “clamshell” type - not<br />
a card or keyfog.<br />
Tailgating Entering the secure area by following an authorised user through<br />
a door.<br />
Timezone A period of time whcih can be given to a cardholder to grant<br />
access of assigned to other functions on the access control system<br />
T Modem Device used with Excelsior to extend RS232 comms lines and<br />
regenerate RS 485 on a standard controller line.<br />
Track 2 Standard magstripe cards have three tracks - 1,2, & 3. Track 2 is<br />
the most commonly track used for access control. Track 3 is the approved<br />
track for “read/write” - used for cashless vending etc.<br />
t.REX Egress PIR specifically designed for access control. The PIR can be<br />
directed to release the door only when a specific area (door handle or push<br />
plate) is touched.<br />
Watermark Special mag stripe tape produced by Thorn Secure Science.<br />
Used by the MoD & BT. Two versions are generally used, 10 character and 9<br />
character LRC. Requires special firmware for Excelsior. Watermark (track 0)<br />
mag stripe readers.<br />
Wiegand A high security card and reader technology using allow wires<br />
twisted and set into a card insert. These produce a binary number. Wiegand<br />
is also a format generally used by proximity readers - 26 bit being the industry<br />
standard. Suppliers generally have their own securie formats available.<br />
61
62<br />
Notes
Notes<br />
63
Notes<br />
64
Who’s Where?<br />
<strong>Product</strong> Management<br />
Sunbury +44 (0) 1932 743327<br />
Field Support<br />
Sunbury +44 (0) 1932 743327<br />
Helpdesk<br />
Sunbury<br />
Tel: +44 (0) 1932 743327<br />
Fax: +44 (0) 1932 743330<br />
tepghelp@tycoint.com<br />
Customer Services (UK)<br />
Walthamstow +44 (0) 208 919 4000<br />
Distribution Centre (UK)<br />
Letchworth +44 (0) 1462 667 700<br />
Sunbury<br />
The Summit, Hanworth Road<br />
Sunbury On Thames<br />
Middlesex<br />
TW16 5DB<br />
Telephone: +44 (0) 1932 743333<br />
Facsimile: +44 (0) 1932 743330<br />
Walthamstow<br />
160 Billet Road<br />
Walthamstow<br />
London<br />
E17 5DR<br />
Telephone: +44 (0) 208 919 4000<br />
Facsimile: +44 (0) 208 919 4040<br />
Letchworth<br />
Dunhams Lane<br />
Letchworth<br />
Herts.<br />
SG6 1BE<br />
Telephone: +44 (0) 1 462 667 700<br />
Facsimile: +44 (0) 1 462 667 777<br />
The right is reserved to modify or withdraw any<br />
product or service without notice<br />
<strong>Product</strong> <strong>Catalogue</strong> PMC011 <strong>Issue</strong> 1<br />
©Tyco Safety <strong>Product</strong>s 2002<br />
www.tycosafetyproducts-europe.com