<strong>data</strong> <strong>sheet</strong><br />

Elcometer 138 Bresle Salt Kit<br />

Elcometer 138 Bresle Salt Kit<br />

Can be used in accordance with:<br />

AS 3894.6-A<br />

IMO MSC.215 (82)<br />

IMO MSC.244 (83)<br />

ISO 8502-6<br />

ISO 8502-9<br />

SSPC Guide 15<br />

US Navy NSI 009-32<br />

US Navy PPI 63101-000<br />

It is essential that the level of<br />

contaminants on a surface is measured<br />

prior to application of the coating to<br />

ensure the quality of the coating and<br />

that its optimum lifetime is achieved.<br />

If the coating is applied to a<br />

contaminated surface, which is not<br />

properly prepared, it could fail<br />

prematurely resulting in costly recoating<br />

and high maintenance costs.<br />

The Elcometer 138 Bresle Kit includes<br />

the Elcometer 138 Conductivity Meter.<br />

This lightweight, portable conductivity<br />

meter accurately measures the salinity<br />

of the test samples.<br />

The cartridge type sensor can be easily<br />

replaced when necessary and displays<br />

conductivity (μS/cm and mS/cm) and<br />

salinity (%) on the digital display.<br />

Features of the meter include indication<br />

of stability of reading indication.<br />

Surface Cleanliness<br />

Surface contamination from salts such<br />

as chlorides, sulphates and nitrates<br />

have been shown to lead to blistering<br />

of organic coatings, particularly in<br />

immersion conditions.<br />

Measuring the surface cleanliness of<br />

the substrate alone prior to a coating<br />

being applied may not be sufficient. If<br />

more than one layer of coating is being<br />

used, it is necessary to monitor and<br />

record the cleanliness of each layer<br />

prior to applying the next coating.<br />

When using amine cured epoxy<br />

coatings, for example, in low ambient<br />

temperatures or in high humidity, a<br />

surface oiliness or exudate may cause<br />

inter-coating adhesion failure.<br />

Tests per Kit 25<br />

Dimensions 300 x 220 x 75mm (11 x 8.6 x 3”)<br />

Weight<br />

Measuring Range<br />

2.1kg (4.62lb)<br />

TECHNICAL SPECIFICATION<br />

2% full scale ±1 digit. At a depth of more than 10mS/cm, the range is 3% full scale ±1 digit<br />

Part Number E138----1 Elcometer 138 Bresle Salt Kit<br />

Packing List<br />

Box of 25 x Elcometer Bresle patches, 250ml pure water in clear plastic bottle, 3 x 5ml (0.1fl oz)<br />

syringes, 3 x blunt needles, 30ml (1fl oz) plastic beaker, Elcometer 138 Conductivity Meter, 2 x<br />

CR2032 lithium batteries, 2 x standard solution (1.41 mS/cm), moistening solution, purified water,<br />

pipette, conductivity meter storage pouch, carry case and operating instructions<br />

SPARES & ACCESSORIES<br />

Bresle Patches (Box of 25)<br />

E135----B<br />

3 x 5ml (0.1fl oz) Syringes T13818517<br />

3 x Needles T13818518<br />

Plastic Beaker 30ml (1fl oz)<br />

T13818519<br />

4 x Calibration Standards Solution T13818516<br />

Pure Water 250ml (8.5fl oz) Bottle<br />

T99911344<br />

www.elcometer.com<br />

1 / 2<br />

Elcometer 138 Bresle Salt Kit<br />

V5: 12.10.11


<strong>data</strong> <strong>sheet</strong><br />

Related Products<br />

Elcometer 134A<br />

Elcometer 134A Chloride Ion Test Kit for Abrasives<br />

Chlorides deposited on a surface by contaminated abrasives during blasting can<br />

cause a coating to fail prematurely. Contamination can build up, particularly if the<br />

blast media is recycled several times. Using the Elcometer 134A Chloride Ion Test in<br />

the field will accurately identify contamination and prevent costly surface-related<br />

failures.<br />

Elcometer 134W Chloride Ion Test Kit for Water<br />

If the chloride levels in the wash water are too high, this will promote premature<br />

corrosion, shortening the life of both steel and concrete structures. Used to monitor<br />

recycled water (after it has been applied) to establish effectiveness of salt removal,<br />

this test is ideal when mixing concrete and when washing steel.<br />

Elcometer 134W<br />

Elcometer 134S Chloride Ion Test Kit for Surfaces<br />

Chloride salts left on the surface before the first coat is applied can result in the<br />

coating system being forced off the surface by corrosion or blistering before the full<br />

life of the coating has been reached. To ensure that the chloride has been removed it<br />

is essential that the surface is tested before the coating is applied.<br />

Elcometer 134S<br />

Elcometer 138/2 Surface Contamination Kit<br />

The Elcometer 138/2 Surface Contamination Kit provides the user with a means for<br />

testing invisible surface contaminants including: pH, chloride ions, iron, salts.<br />

Elcometer 138<br />

www.elcometer.com<br />

2 / 2<br />

Elcometer 138 Bresle Salt Kit<br />