6.1<br />

<strong>Fire</strong> <strong>Protection</strong><br />

<strong>Fire</strong> protection<br />

Application details for beams<br />

Beam with partition abutment<br />

25 x 25mm angle secured to top flange<br />

of beam, or alternatively to soffit<br />

<strong>Knauf</strong> Drywall Screws at maximum<br />

100mm centres<br />

<strong>Fire</strong>board casing<br />

Backing strip<br />

10mm gap<br />

Direct edge fixing with <strong>Knauf</strong> Drywall<br />

Screws at maximum 150mm centres or<br />

staples at 120mm centres<br />

C-Stud partition with standard<br />

U-Channel head track<br />

Beam with wall abutment<br />

25 x 25mm angle secured to top flange of<br />

beam, or alternatively to soffit<br />

<strong>Knauf</strong> Drywall Screws at maximum<br />

100mm centres<br />

<strong>Fire</strong>board casing<br />

Direct edge fixing with <strong>Knauf</strong><br />

<strong>Fire</strong>board Gripper Screws at<br />

maximum 150mm centres or<br />

staples at 120mm centres<br />

Continuous 25 x 25mm <strong>Knauf</strong><br />

<strong>Fire</strong>board Angle secured to substrate<br />

using appropriate fixings<br />

Masonry wall<br />

272<br />

Technical Advice and Support Centre 01744 766666<br />

www.knaufinsulation.co.uk