October 2011<br />

Polyfoam ® <strong>ECO</strong> <strong>Roofboard</strong><br />

For flat roofs<br />

Description<br />

Polyfoam <strong>ECO</strong> <strong>Roofboard</strong>s are available in two grades - Extra and Super. They are rigid extruded<br />

polystyrene boards with Zero Ozone Depletion Potential (ODP) and a Global Warming Potential<br />

(GWP) of less than five. They are lightweight square edged or lap jointed boards that have a high<br />

compressive strength.<br />

Application<br />

Polyfoam <strong>ECO</strong> <strong>Roofboard</strong>s are used for the thermal insulation of flat roofs and can be used:<br />

• in a warm roof construction below single ply membranes<br />

• in a protected membrane roof below ballast or paving slabs (1)<br />

• as the insulation layer in a green/garden roof<br />

• under concrete for a roof top car park<br />

(1) See also the separate <strong>Knauf</strong> <strong>Insulation</strong> datasheet on the Polyfoam Slimline membrane<br />

(Ref: PD136210). When used in conjunction with the Polyfoam Slimline membrane as part of<br />

the Polyfoam Slimline system, this solution offers industry leading thermal performance and weight<br />

reduction in protected membrane roofing systems.<br />

Standards<br />

Polyfoam <strong>ECO</strong> <strong>Roofboard</strong>s are manufactured in accordance with BS EN 13164:2008, EN<br />

16001:2009 Energy Management Systems, OHSAS 18001:2007 Occupational Health and<br />

Safety Management Systems, ISO 14001:2004 Environmental Management Systems, and ISO<br />

9001:2008 Quality Management Systems, as certified by Bureau Veritas.<br />

Performance<br />

Thermal<br />

The thermal conductivity of Polyfoam <strong>ECO</strong> <strong>Roofboard</strong><br />

is 0.033 to 0.036W/mK depending on the product<br />

and thickness.<br />

Benefits<br />

• Excellent thermal performance<br />

• High compressive strength<br />

• Highly resistant to water absorption<br />

• Able to resist repeated freeze/thaw cycles<br />

• Lightweight and easy to install<br />

• Tough and durable, not easily damaged<br />

• Dimensionally stable<br />

• As part of the Polyfoam Slimline System:<br />

– Improves the thermal performance of<br />

protected membrane flat roofs<br />

– Enables thinner insulation and less ballast to<br />

be used with no loss of thermal performance<br />

– Produces a thermally efficient and<br />

lightweight roof


Polyfoam ® <strong>ECO</strong> <strong>Roofboard</strong><br />

Durability<br />

The continuous service temperature limits of Polyfoam <strong>ECO</strong> <strong>Roofboard</strong> are -20 to +70º C.<br />

Environmental<br />

Polyfoam <strong>ECO</strong> <strong>Roofboard</strong>s are manufactured with a GWP


Polyfoam ® <strong>ECO</strong> <strong>Roofboard</strong><br />

Thickness<br />

Thermal<br />

conductivity Thermal resistance Length Width Compressive strength<br />

(mm) (W/mK) (m 2 K/W) (mm) (mm) (kPa)<br />

Polyfoam <strong>ECO</strong> <strong>Roofboard</strong> Extra<br />

160 LJ 0.035 4.55 1250 600 300<br />

140 LJ 0.035 4.00 1250 600 300<br />

120 LJ 0.035 3.40 1250 600 300<br />

110 LJ 0.035 3.10 1250 600 300<br />

80 SE 0.035 2.25 1250 600 300<br />

70 SE 0.035 2.00 1250 600 300<br />

60 SE 0.035 1.70 1250 600 300<br />

55 SE 0.035 1.55 1250 600 300<br />

50 SE 0.033 1.50 1250 600 300<br />

Polyfoam <strong>ECO</strong> <strong>Roofboard</strong> Super<br />

100 LJ 0.036 2.75 1250 600 500<br />

80 LJ 0.036 2.20 1250 600 500<br />

60 LJ 0.034 1.75 1250 600 500<br />

50 LJ 0.034 1.45 1250 600 500<br />

All dimensions are nominal. L J = Lap Jointed, SE = Square Edged.<br />

<strong>Knauf</strong> <strong>Insulation</strong> Ltd<br />

PO Box 10<br />

Stafford Road<br />

St Helens<br />

Merseyside<br />

WA10 3NS<br />

Customer Service (sales)<br />

Tel: 0844 800 0135<br />

Technical Advisory Centre<br />

Tel: 01744 766 666<br />

Literature<br />

Tel: 08700 668 660<br />

www.knaufinsulation.co.uk<br />

Ref: GD022211<br />

For more information please visit<br />

www.knaufinsulation.co.uk<br />

All rights reserved, including those of photomechanical reproduction and storage in electronic media. Commercial use of the processes and work activities presented in this document is not permitted. Extreme caution<br />

was observed when putting together the information, texts and illustrations in this document. Nevertheless, errors cannot quite be ruled out. The publisher and editors cannot assume legal responsibility or any liability<br />

whatever for incorrect information and the consequences thereof. The publisher and editors will be grateful for improvement suggestions and details of errors pointed out.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!