Other issues<br />
Frame Format<br />
The MUC_080128_inkl_Anlagen.pdf SRR section 5, ANNEX A: WIRELESS M-<br />
BUS MESSAGES, refers to the FT1.2 message format. For all wireless transmissions<br />
the FT3 message format should be used. This is corrected in the OMS-Spec-<br />
Vol1_General_v100.pdf and OMS-Spec_Vol2_Primary_v102.pdf.<br />
Wireless modes<br />
I strongly suggest to choose between S2 and T2 modes for wireless transmissions.<br />
Leaving the choice open will probably not help much in designing interoperable<br />
systems. (MUC_080128_inkl_Anlagen.pdf SRR section 3.1).<br />
Differences between OMS/MUC and Dutch approach 1<br />
Topic RWE spec Dutch spec<br />
Identification<br />
Serial Number R/W R - Header<br />
Meter Type R R - Header<br />
Manufacturer text R -<br />
Manufactured date R -<br />
Volume / Tariff<br />
Volume Index Corrected W -<br />
Volume Index with Active Tariff R -<br />
New Tariff – Effective date/time W -<br />
Valve<br />
Valve State R/W R/W<br />
Valve Number of Closes R -<br />
Battery<br />
Remaining Battery Days R - 2<br />
System State<br />
Date and Time R/W R/W<br />
Time Synchronisation Offset W -<br />
Extended Error Flag R/W -<br />
Daylight Saving R/W -<br />
Information Transfer<br />
Meter Information Request R -<br />
Transparent Information R/W -<br />
Configuration<br />
Time between RF polls R/W - 3<br />
1 Note that the Dutch specification explicitly specifies that all DIF/VIF codes in the EN13757-3 can be<br />
exchanged. It is likely that some data objects do not contain useful information, but technically they<br />
can be exchanged. In this table we only refer to data objects that will contain “defined and useful data”.<br />
2 Calculated in MUC<br />
Review M-bus.doc 5 04/12/2008