GC CAPILLARY & PACKED COLUMNS<br />
CAPILLARY COLUMN ACCESSORIES<br />
Capillary Survival Kit TM<br />
Our Capillary Survival Kit was designed with the practicing chromatographer in mind. Each kit<br />
includes:<br />
• Magnier with built in light<br />
• Slide-Lok tweezers for holding small items;<br />
“spacing” the column proper distances into<br />
the injection port, etc.<br />
• 15 cm steel ruler<br />
• 3 column scribes, for cleanly-cut columns<br />
• 2 universal unions for joining broken capillary<br />
columns or connecting guard columns<br />
• Single-ended pinvise holds drill bits<br />
• 3 drill bits, 0.4 mm, 0.5 mm and 0.8 mm<br />
• Multipurpose septum pick<br />
• Nylon brushes, 1/8”, 3/16”, and 1/4”<br />
• Pipecleaners 5 each,1/8” OD and 1/4” OD<br />
• Open-end wrench, 1/4” + 5/16”<br />
• High temperature string (>400 O C) 25 ft.<br />
• Ferrule remover - 2<br />
AUC205625<br />
Description<br />
Capillary Survival Kit<br />
Item No.<br />
AUC205625<br />
Universal Fused Silica Connectors<br />
Universal Connector;<br />
Universal Y-Splitter<br />
These quartz connectors will join columns from 0.25 mm to 0.53 mm id. Procedure: cut the<br />
capillary column with a ceramic column scribe; be sure the end is cut squarely. Insert the column<br />
into the appropriate leg of the connector to make a snug t. Heat in the GC oven under carrier gas<br />
ow for one hour at 250ºC, to fuse the column’s polyimide coating to the wall of the union. For a<br />
stronger physical attachment we recommend using polyimide sealing resin.<br />
Description<br />
Universal Connector, 5/pk<br />
Universal Y-Splitter, each<br />
Item No.<br />
AUC207950<br />
AUC207960<br />
Fused Silica Guard Column Kits<br />
Kits include one 5 meter length of deactivated fused silica tubing and 5 universal glass unions.<br />
Connect a length of tubing from 1/2 to 5 meters to your column, by inserting one end of each into<br />
a universal union snugly. Fuse at 125ºC under carrier gas ow in the GC oven for one hour. When<br />
the guard column becomes contaminated break off a 1/2 meter length.<br />
Fused Silica Guard Column Kit<br />
Description<br />
Item No.<br />
0.25 mm id Guard Column Kit AUC207625<br />
0.32 mm id Guard Column Kit AUC207632<br />
0.53 mm id Guard Column Kit AUC207653<br />
Cap. 1: 16<br />
<strong>Konik</strong>-Tech