GC CAPILLARY & PACKED COLUMNS<br />

Glass Columns - Silane Treated<br />

• Custom Packed to your specications<br />

• Silanized for inertness<br />

• High quality<br />

• Available for most instruments<br />

Glass Column<br />

Column Conguration. The length of the “arms” is indicated by dimensions X and Y. These dimensions<br />

along with the span between the arms allows conrmation that the column will t correctly in<br />

your instrument.<br />

Column Installation. All of our glass columns are supplied with nuts and graphite ferrules. We<br />

recommend graphite ferrules because they are soft, to seal securely around the column without<br />

excessive tightening. They will not stick to the glass, for easy removal. Complete installation<br />

instructions are included with each column.<br />

Recommended Accessories:<br />

• 1/4” Graphite ferrules (10/pk) - Item AUC211400<br />

To Order a Packed Column<br />

Specify the “empty” catalog number with a “P” added to the end, and specify the packing<br />

(example: 3% OV-225 on Chromosorb ® W-HP, 80/100 mesh). Some expensive packing materials<br />

are subject to a surcharge; see the Surcharge Table.<br />

1. Stationary Phase (see listings on page 27)<br />

Expensive phases have surcharges; see Surcharge Table<br />

A) Stationary Phase 1<br />

% Loading<br />

B) Stationary Phase 2 - Surcharge for dual phase columns<br />

% Loading<br />

2. Solid Support - Specify material and grade (example: Chromosorb W-AW; HayeSep ® D)<br />

Expensive supports have surcharges; see Surcharge Table<br />

C) Support<br />

D) Mesh Size- specify one: 60/80, 80/100, or 100/120<br />

Surcharge Table: Surcharges apply to the following expensive phases:<br />

Stationary Phase Surcharges<br />

Support Surcharges<br />

• Dexsils<br />

• Chromosorb T<br />

• EGSS-X<br />

• Carbon Molecular Sieves<br />

• OV-225<br />

• HayeSep<br />

• OV-275 • Porapak ®<br />

• OV-330 • Chromosorb 101 - 109<br />

• OV-1701 • Tenax ®<br />

• Polyphenylether<br />

• Carbopacks<br />

• Silars<br />

Cap. 1: 24<br />

<strong>Konik</strong>-Tech