In the second dimension, the OAM cells are classified by function. The distinction here<br />

is made between performance management, fault management or activation / deactivation<br />

OAM cells. To provide this distinction the fields labeled ‘OAM type’ and ‘Function<br />

type’ in the OAM payload are used. The former field takes the bit-value ‘0001’ for fault<br />

management, the bit-value ‘0010’ for performance management and the bit-value ‘1000’<br />

for activation / deactivation. Each of these classes is further subdivided into several<br />

modes, for which the latter field is used. Performance monitoring operates in the tree<br />

modes: forward monitoring, backward reporting and monitoring and reporting, indicating<br />

in which direction the PM OAM flows 6 . The ‘Function Type’ is set to the bit-values<br />

‘0000’, ‘0001’ and ‘0010’ respectively. For fault management four different modes are<br />

defined: alarm indication signal, remote defect indicator, cell loopback and continuity<br />

check. These four modes as well as their values in the field ‘Function type’ will be<br />

explained in detail below. Finally, the activation / deactivation OAM cell is used to turn<br />

the management functions on and off. ‘Function Type’ here takes the value ‘0000’ to<br />

toggle the activation mode of performance management, and the value ‘0001’ to toggle<br />

the activation mode of fault management. This mode provides an important flexibility to<br />

ATM network management, as will be shown in the next section. Figure 45 summarizes<br />

the functional dimension of the different OAM cell formats.<br />

Header<br />

OAM<br />

Type<br />

Function<br />

Type<br />

Function<br />

Specific<br />

Fields<br />

C<br />

R<br />

C<br />

Fault Management 0001 AIS 0000<br />

RDI 0001<br />

Cell loopback 1000<br />

Continuity Check 0100<br />

Performance Management 0010 Forward monitoring 0000<br />

Backward reporting 0001<br />

Monitoring & reporting 0010<br />

Activation / deactivation 1000 Performance monitoring 0000<br />

Continuity check 0001<br />

Figure 45: OAM Cell Formats in the functionality dimension<br />

6 forward: from VPC/VCC starting point to VPC/VCC end point, backward: from VPC/VCC end point to VPC/VCC<br />

starting point, monitoring and reporting: both directions.<br />

105