Description Aquatower 2000 1/2" wall mounted profile ... - GROHE
Description Aquatower 2000 1/2" wall mounted profile ... - GROHE
Description Aquatower 2000 1/2" wall mounted profile ... - GROHE
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
27017 000 Page 6<br />
Maintenance instructions<br />
Shut off hot and cold water supply!<br />
Please perform disassembly in specified order.<br />
Thermoelement<br />
1. Lever out cap.<br />
2. Loosen screw.<br />
3. Pull off temperature selection handle.<br />
4. Remove clip.<br />
5. Pull off stop ring.<br />
6. Pull off regulating nut with overload unit.<br />
7. Unscrew and remove thermoelement using a 22mm<br />
open-ended spanner.<br />
Aquadimmer<br />
1. Lever out cap.<br />
2. Unscrew and remove screw, pull off shut-off handle.<br />
3. Remove splined adapter and stop.<br />
4. Unscrew and remove Aquadimmer using a 19mm openended<br />
spanner.<br />
Observe the correct installation position.<br />
1. The dissimilar pins (1) and (2) must engage in the<br />
corresponding holes in the race.<br />
2. Fit stop with marking pointing downwards, markings (3)<br />
and (4) align.<br />
3. Fit splined adapter, the faces coincide in only one<br />
position.<br />
4. Turn splined adapter so that the lug points to the right.<br />
Grohe UK Ltd | Tel.: +44 871 200 3414 | email: info@grohe.co.uk | www.grohe.co.uk |<br />
Address: Blays House, Wick Road, Englefield Green, Egham, Surrey, UK, TW20 0HJ