27017 000 Page 6<br />

Maintenance instructions<br />

Shut off hot and cold water supply!<br />

Please perform disassembly in specified order.<br />

Thermoelement<br />

1. Lever out cap.<br />

2. Loosen screw.<br />

3. Pull off temperature selection handle.<br />

4. Remove clip.<br />

5. Pull off stop ring.<br />

6. Pull off regulating nut with overload unit.<br />

7. Unscrew and remove thermoelement using a 22mm<br />

open-ended spanner.<br />

Aquadimmer<br />

1. Lever out cap.<br />

2. Unscrew and remove screw, pull off shut-off handle.<br />

3. Remove splined adapter and stop.<br />

4. Unscrew and remove Aquadimmer using a 19mm openended<br />

spanner.<br />

Observe the correct installation position.<br />

1. The dissimilar pins (1) and (2) must engage in the<br />

corresponding holes in the race.<br />

2. Fit stop with marking pointing downwards, markings (3)<br />

and (4) align.<br />

3. Fit splined adapter, the faces coincide in only one<br />

position.<br />

4. Turn splined adapter so that the lug points to the right.<br />