V2PM400Y/230VS10 V2PM400Y/230VS10P ... - Tele Haase
V2PM400Y/230VS10 V2PM400Y/230VS10P ... - Tele Haase
V2PM400Y/230VS10 V2PM400Y/230VS10P ... - Tele Haase
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
VEO<br />
MONITORING RELAY / 3-PHASE VOLTAGE<br />
<strong>V2PM400Y</strong>/<strong>230VS10</strong><br />
Art.Nr.: 2100500<br />
<strong>V2PM400Y</strong>/<strong>230VS10</strong>P<br />
Art.Nr.: 2100510<br />
GENERAL DATA<br />
Electrical connection V2PM...10P Push-in terminal<br />
Wire size<br />
flexible with wire<br />
end ferrule<br />
flexible with<br />
plastic ferrule<br />
0,25 … 1,5 mm² (24 AWG … 16 AWG)<br />
0,25 … 0,75 mm² (24 AWG … 19 AWG)<br />
Stripping length<br />
flexible without<br />
wire end ferrule<br />
rigid<br />
0,2 … 1,5 mm² (24 AWG … 16 AWG)<br />
0,2 … 1,5 mm² (24 AWG … 16 AWG)<br />
8 mm<br />
MTTF -<br />
Weight<br />
86 g<br />
ISOLATION DATA<br />
Pollution degree<br />
(IEC 60947-5-1)<br />
Overvoltage category<br />
(IEC 60947-5-1)<br />
Rated insulation voltage<br />
(IEC 60947-1)<br />
Rated impulse withstanding voltage<br />
(IEC 60947-1)<br />
Insulation test voltage<br />
(IEC 60947-1)<br />
supply circuit /<br />
output circuit<br />
supply circuit /<br />
output circuit<br />
supply circuit /<br />
output circuit<br />
2<br />
III<br />
300 V<br />
6 kV<br />
3780 V<br />
Degree of protection supply circuit /<br />
output circuit<br />
protective seperation<br />
STANDARDS<br />
Product standard IEC 60947-5-1<br />
Interference immunity IEC 61000-6-2<br />
Interference emmision IEC 61000-6-4<br />
Approvals<br />
http://tele-online.com<br />
Page 4 of 7