Component Test Procedure Check result Remark<br />
13. Outlet Thermostat<br />
(Auto reset)<br />
Measure resistance of terminal<br />
to terminal<br />
Open at 203 ± 7°F (95 ± 5°C)<br />
Close at 158 ± 9°F (70 ± 5°C)<br />
Resistance value<br />
Continuity < 1Ω<br />
∞<br />
• Gas type<br />
• Gas funnel<br />
• Check Top Marking :<br />
N95<br />
13. Outlet Thermostat<br />
(Manual reset)<br />
Measure resistance of terminal<br />
to terminal<br />
Open at 212 ± 12°F<br />
(100 ± 7°C)<br />
Manual reset<br />
If thermal fuse is open must<br />
be replaced<br />
Resistance value ∞<br />
Continuity < 1Ω<br />
• Gas type<br />
• Gas funnel<br />
• Check Top Marking :<br />
N100<br />