Component Test Procedure Check result Remark<br />

13. Outlet Thermostat<br />

(Auto reset)<br />

Measure resistance of terminal<br />

to terminal<br />

Open at 203 ± 7°F (95 ± 5°C)<br />

Close at 158 ± 9°F (70 ± 5°C)<br />

Resistance value<br />

Continuity < 1Ω<br />

∞<br />

• Gas type<br />

• Gas funnel<br />

• Check Top Marking :<br />

N95<br />

13. Outlet Thermostat<br />

(Manual reset)<br />

Measure resistance of terminal<br />

to terminal<br />

Open at 212 ± 12°F<br />

(100 ± 7°C)<br />

Manual reset<br />

If thermal fuse is open must<br />

be replaced<br />

Resistance value ∞<br />

Continuity < 1Ω<br />

• Gas type<br />

• Gas funnel<br />

• Check Top Marking :<br />

N100<br />