Fluke 975 AirMeter <br />

Simple, one-touch air velocity<br />

The Fluke 975 AirMeter combines five powerful air<br />

quality tools into one. Identify and diagnose indoor<br />

air quality issues quickly and easily with one rugged,<br />

handheld device.<br />

• Simultaneously measures, logs and displays<br />

temperature, humidity, CO 2 and CO on a bright,<br />

backlit LCD display<br />

• % of outside air calculation<br />

• One-touch air flow and velocity with available<br />

probe*<br />

• Dew point and wet bulb temperature<br />

• CO 2 and CO field calibration feature<br />

• Min/Max/Avg on all measured and calculated<br />

readings<br />

• Audible and visual threshold alarms<br />

• Extensive discrete or continuous data logging<br />

capacity, downloadable to PC via USB interface<br />

• Includes NIST-traceable certificate of calibration<br />

• Automatically compensates for barometric pressure<br />

changes<br />

• Two-year warranty<br />

*Included with Fluke 975V, optional with Fluke 975.<br />

Recommended accessories<br />

Fluke 975VP<br />

AirMeter Velocity Probe for use with Fluke 975 AirMeter.<br />

Recommended kits<br />

Fluke 975V<br />

• 975 AirMeter<br />

• Calibration cap<br />

• Air velocity probe<br />

• FlukeView® Forms software<br />

• Power adapter<br />

• International power plugs<br />

• Hard carrying case<br />

• Three AA alkaline batteries<br />

• Users manual with safety information<br />

Specifications<br />

975 features Range Display resolution Accuracy<br />

Temperature<br />

± 0.9 °C/± 1.62 °F from 40 °C to 60 °C ± 0.5 °C/<br />

-20 °C to 50 °C<br />

0.1 °C (0.1 °F)<br />

± 1.00 °F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F<br />

(-5 °F to 122 °F)<br />

from -20 °C to 5 °C<br />

Relative humidity 10 % to 90 % RH<br />

1 % ± 2 % RH (10 % RH to 90 % RH)<br />

non-condensing<br />

Air velocity<br />

Fluke 922 Airflow Meter/Micromanometer<br />

Make airflow measurements easy by combining differential pressure, air<br />

flow and velocity into a single, rugged meter. Used with any pitot tube,<br />

the Fluke 922 is the perfect entry point for technicians measuring air<br />

flow for the first time, yet powerful enough for advanced users.<br />

• Measures differential and static pressure, air velocity and flow<br />

readings<br />

• User-defined duct shape and size for maximum airflow accuracy<br />

• Bright, backlit display<br />

• Min/Max/Avg/Hold functions<br />

• Auto power off<br />

50.0 fpm to 3000 fpm<br />

0.25 m/sec to 15 m/sec<br />

1 fpm (0.005 m/sec)<br />

± 4 % or 4 fpm* ± 4 % or 0.02 m/sec* whichever is<br />

greater * Accuracy specification only valid for velocity<br />

readings above 50 fpm<br />

CO 2 Warm up time 1 min (5 minutes for full specification)<br />

0 ppm to 5000 ppm 1 ppm<br />

2.75 % + 75 ppm<br />

CO<br />

± 5 % or ± 3 ppm, whichever is greater,<br />

0 ppm to 500 ppm 1 ppm<br />

@ 20 °C and 50 % RH<br />

Fluke 922/Kit<br />

• 922 Airflow meter<br />

• 12 inch pitot tube<br />

• Two rubber hoses<br />

• TPak magnetic strip<br />

• TPak strap, 9 inches<br />

• TPak latch tab<br />

• Four AA 1.5 V alkaline batteries<br />

• Users manual<br />

• Hard carrying case<br />

922 features Range Accuracy<br />

Air pressure<br />

± 1 % + 1 Pascal / ± 1 % + 0.01 in H2O /<br />

± 4000 Pascals / ± 16 in H2O / ± 400 mm H2O /<br />

± 1 % + 0.1 mm H2O / ± 1 % + 0.01 mbar /<br />

± 40 mbar / ± 0.6 PSI<br />

± 1 % + 0.0001 PSI<br />

Air velocity 250 fpm to 16,000 fpm (1 to 80 m/s) ± 2.5 % of reading at 2000 fpm (10.00 m/s)<br />

Air flow (volume) 0 to 99,999 cfm; 0 to 99,999 m 3/hr; 0 to 99,999 l/s Accuracy is a function of velocity and duct size<br />

Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F)<br />

Data storage<br />

99 readings<br />

Warranty<br />

Two-year<br />

Power<br />

Four AA batteries<br />

Ordering information<br />

Included accessories<br />

Models<br />

FLUKE-975<br />

FLUKE-975V<br />

Calibration cap, air velocity probe (Fluke 975V only), FlukeView® Forms<br />

software, power adapter, international power plugs, hard carrying case,<br />

three AA alkaline batteries, users manual with safety information.<br />

Two rubber hoses, soft carrying case, four AA alkaline batteries 1.5 V,<br />

users manual.<br />

12 inch pitot tube, two rubber hoses, ToolPak Magnetic Meter Hanging Kit,<br />

hard carrying case, four AA alkaline batteries 1.5 V, users manual.<br />

AirMeter<br />

AirMeter with Velocity<br />

FLUKE-922<br />

FLUKE-922/KIT<br />

Airflow Meter<br />

Airflow Meter Kit<br />

Check price and availability at<br />

www.fluke.com/wtb<br />

23<br />

Indoor Air Quality <strong>Tools</strong><br />

For more information, go to www.fluke.com/IAQ