<strong>REDIPRESS</strong> MONITOR<br />

Green System Normal<br />

Red Alarm Condition<br />

R<br />

Amber Fault Condition<br />

Press to RESET<br />

<strong>REDIPRESS</strong><br />

17mm<br />

7mm<br />

Low Profile<br />

Standard<br />

Optional End Cap<br />

<strong>REDIPRESS</strong><br />

Flexible cover<br />

Aluminium<br />

Mounting Channel<br />

Tamper Resistant <strong>REDIPRESS</strong><br />

High<br />

Profile<br />

Tamper Resistant<br />

High Profile<br />

Mounting Channel<br />

<strong>REDIPRESS</strong> Standard is a normally open momentary<br />

switch where a press-at-any-point facility is needed. It is<br />

available in two profiles. Low profile (Green or Black) for<br />

finger operation, High profile (Red or White) for finger,<br />

hand or foot operation. It can be supplied in any length.<br />

Although the strip is flexible it will not cope with corners, it<br />

must therefore be joined at corners.<br />

In its simplest form it is terminated at one end with a<br />

400mm two core cable, the remote end being sealed but<br />

open circuit. For security systems it is often necessary to<br />

monitor a circuit against deliberate or accidental<br />

disconnection. <strong>REDIPRESS</strong> can be terminated at both<br />

ends with 400 mm of two core cable to form part of a 4<br />

wire double pole system, or supplied terminated at one<br />

end with two core cable, and at the remote end with an<br />

End Of Line Resistor for remote monitoring by a control<br />

panel or by a REDIMON unit. An optional end cap is<br />

available to finish each end if required<br />

16mm<br />

Low<br />

Profile<br />

44mm<br />

<strong>REDIPRESS</strong> Tamper<br />

Resistant uses the<br />

same switch elements as<br />

the standard version but<br />

has a tamper resistant<br />

flexible red cover to give<br />

extra protection to the<br />

switch element.<br />

To accommodate the cover a larger aluminium mounting<br />

channel is supplied. The cover clips on as shown above.<br />

End caps are also included to enable a smooth transition<br />

to 25 x 15mm mini trunking. Shown here pre and post<br />

completion.<br />

Note: <strong>REDIPRESS</strong> should not be used on mains<br />

voltage without a suitable step down transformer.<br />

65mm<br />

3.22m 65mm<br />

3.35m<br />

When ordering <strong>REDIPRESS</strong> Standard allow 65mm at<br />

each cable end for junction boxes and terminations.<br />

Therefore if the wall to wall measurement is<br />

3.35metres you should order (3.35 - 0.13) = 3.22m<br />

When ordering <strong>REDIPRESS</strong> Tamper Resistant specify<br />

only the overall measurement. Therefore if the wall to<br />

wall measurement is 3.35metres you should order<br />

3.35m.<br />

<strong>REDIPRESS</strong> is cut and factory terminated. It cannot be returned for credit or FOC alteration.<br />

2 core cable to control<br />

2 core cable to control<br />

6 core cable for 12vdc power<br />

alarm and fault<br />

2 core cable<br />

2 core cable<br />

2 core cable<br />

Junction boxes<br />

Junction boxes<br />

REDIMON<br />

Junction boxes<br />

Junction box Type 1<br />

Type 1 Type 1<br />

Type 2<br />

Junction boxes<br />

Type 2<br />

Type 3<br />

Type 3<br />

Junction boxes<br />

Type 2<br />

Type 3<br />

Fig 1<br />

Fig 2<br />

Fig 3<br />

Fig 1 shows <strong>REDIPRESS</strong> connected in an<br />

open circuit system. The strips are<br />

connected in parallel. This is the most<br />

economical method as it uses TYPE 1<br />

terminations, however, it is of course unmonitored.<br />

Fig 2 uses TYPE 2 and TYPE 3<br />

terminations to form a monitored system.<br />

The value of the End of Line resistor must<br />

be matched to the control system and<br />

must be specified on ordering.<br />

Fig 3 shows <strong>REDIPRESS</strong> connected to a<br />

REDIMON unit to provide end of line<br />

monitoring. This uses TYPE 2 and TYPE 3<br />

terminations. The TYPE 3 terminations<br />

would have 6k8 resistor values in this case.<br />

E.O.L.resistor<br />

TERMINATION TYPE 1 TERMINATION TYPE 2 TERMINATION TYPE 3<br />

<strong>Hoyles</strong> Electronic Developments Ltd<br />

Tel: 01744 886600 Fax: 01744 886607 e-mail: info@hoyles.com website: www.hoyles.com<br />

w:\production\instllninstns\60092.cdr


Amber Fault Condition<br />

Please photocopy and fax this order to 01744 886607<br />

Company Branch Tel No Order No<br />

A<br />

Length<br />

in Metres<br />

B<br />

Cost per<br />

Metre<br />

Standard<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

£23.63<br />

C<br />

Cost of<br />

TYPE 1<br />

Termination<br />

£8.30<br />

£16.00<br />

D<br />

Cost of<br />

TYPE 2<br />

Termination<br />

£12.95<br />

£20.65<br />

E<br />

Cost of<br />

TYPE 3<br />

Termination<br />

£10.95<br />

£18.65<br />

Colour<br />

RD Hi profile<br />

WH Hiprofile<br />

BK Lo profile<br />

GN Lo profile<br />

TS3 end caps for standard Redipress are not included<br />

Tamper<br />

Resistant<br />

£35.00<br />

£35.00<br />

£35.00<br />

£35.00<br />

£35.00<br />

£35.00<br />

£35.00<br />

£35.00<br />

Cover Red<br />

Hi or Lo Profile<br />

F<br />

Cost per Length<br />

Terminated<br />

(A x B)+ C,D or E<br />

£<br />

£5.25 each<br />

G<br />

Qty<br />

ie. No. of<br />

Lengths<br />

End caps for Tamper resistant Redipress are included<br />

REDIMON end of line monitor unit (6k8 EOL required) £26.60 ea<br />

Total before carriage<br />

2/3 day carriage 5% of order value. Minimum £4.95 maximum £10.<br />

V.A.T. at 17.5% or rate prevailing at time of despatch<br />

TOTAL<br />

TOTAL<br />

£= F x G<br />

E.O.L Resistor<br />

Value for Type 3<br />

termination.<br />

(6k8 for Redimon)<br />

Note: <strong>REDIPRESS</strong> is cut to order and factory terminated. (Allow 10 - 14 days) It cannot be returned for credit if it is<br />

incorrectly ordered or unsuitable for the application. Short unterminated samples are available free of charge for<br />

client approval if necessary.<br />

REDIMON<br />

End of Line Monitor Unit<br />

REDIMON is a latching monitor unit to monitor two open circuit<br />

momentary devices such as <strong>REDIPRESS</strong> to give alarm and<br />

fault conditions. An end of line resistor (6k8) is fitted at the<br />

remote ends of <strong>REDIPRESS</strong>. Pressing the <strong>REDIPRESS</strong> will<br />

be detected as an alarm condition. If disconnected in any way<br />

a fault condition is generated. The REDIMON requires 12 volts<br />

dc and provides volt free changeover contacts independently<br />

for both alarm and fault. A status LED is provided, this would<br />

normally be illuminated as green for system healthy and would<br />

change to red for alarm and yellow for fault condition.<br />

<strong>REDIPRESS</strong> 1<br />

E.O.L 6k8<br />

N.O. PA<br />

Button<br />

Optional<br />

12 Volts dc power<br />

45ma max<br />

<strong>REDIPRESS</strong> MONITOR<br />

R<br />

Press to RESET<br />

Green System Normal<br />

Red Alarm Condition<br />

<strong>REDIPRESS</strong> 2<br />

E.O.L 6k8<br />

REDIMON<br />

Alarm output<br />

Fault output<br />

<strong>Hoyles</strong> Electronic Developments Ltd<br />

Tel: 01744 886600 Fax: 01744 886607 e-mail: info@hoyles.com website: www.hoyles.com