Dust Filters<br />

FS 2-4, FS 8-16, FS 30-60<br />

a<br />

a<br />

h<br />

c<br />

DN<br />

c<br />

DN<br />

h 1<br />

h<br />

Dust filter<br />

h 1<br />

The dust filters protect the pumps<br />

against the intake of dust.<br />

b<br />

b b1<br />

Advantages to the User<br />

- Easy to disassemble<br />

- Vacuum-tight cast iron casing<br />

- Replacement filters may be easily<br />

exchanged<br />

- Separates dusts from a grain size of<br />

1 µm<br />

Technical Information<br />

Installing a dust filter in the intake line<br />

of the pump will throttle its pumping<br />

speed at low intake pressures more<br />

than at higher intake pressures. This<br />

must be taken into account when designing<br />

a vacuum system.<br />

Since the dust filters have only a small<br />

dust collecting chamber, we recommend<br />

– in the case of larger dust<br />

quantities – the two-stage dust separators<br />

from the AS range.<br />

FS 2-4, FS 8-16 FS 30-60<br />

Type DN a b l b 1 c h, approx. h 1 , approx.<br />

FS 2-4 16 KF mm 90 112 – 30 105 165<br />

in. 3.54 4.41 – 1.18 4.13 6.50<br />

FS 8-16 25 KF mm 110 150 – 50 125 205<br />

in. 4.33 5.91 – 1.97 4.92 8.07<br />

FS 30-60 40 KF mm 130 190 170 60 225 250<br />

in. 5.12 7.48 6.69 2.36 8.86 9.84<br />

Dimensional drawing for the FS dust filters<br />

Technical Data FS 2-4 FS 8-16 FS 30-60<br />

Connection to pump<br />

Ordering Information<br />

<strong>TRIVAC</strong><br />

Throttling of the pumping speed<br />

at 1 mbar (0.75 Torr), approx. %<br />

at 10 mbar (7.5 Torr), approx. %<br />

Weight<br />

kg (lbs)<br />

D 2,5 E<br />

D 4 B D 8 B D 16 B D 25 B D 40 B D 65 B<br />

6 10 12 18 12 25<br />

4 7 6 9 3 8<br />

1.0 (2.2) 1.0 (2.2) 1.6(3.5) 1.6 (3.5) 7.5816.5) 7.516.5)<br />

FS 2-4 FS 8-16 FS 30-60<br />

The dust filters should be installed in a<br />

horizontal flow so that the filter insert<br />

may be removed by pulling it down<br />

and out.<br />

Dust filter<br />

Replacement filter insert<br />

Replacement wadding cartridges<br />

(1 set = 10 pieces)<br />

Part No. 186 05 Part No. 186 10 Part No. 186 15<br />

Part No. 178 32 Part No. 178 33 Part No. 178 35<br />

Part No. Part No. Part No.<br />

200 39 050 200 39 051 971 78 251<br />

Oerlikon Leybold Vacuum Full Line Catalog<br />

51<br />

C01