25.04.2014 Views

WS Series - autocentrated

WS Series - autocentrated

WS Series - autocentrated

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MOLDED-CASE CIRCUIT BREAKERS &<br />

EARTH-LEAKAGE CIRCUIT BREAKERS<br />

Mitsubishi Electric Corporation’s Fukuyama Works.<br />

witch produces these products, is certified as meeting<br />

the ISO14001 environmental management system standard.<br />

Certification No.:EC70J1128 Date of Certification: Nov.26,1997


Mitsubishi Presents the<br />

the High Demands of<br />

Mitsubishi Presents the <strong>WS</strong> <strong>Series</strong>, Satisfying the<br />

High Demands of the Global Standard New from<br />

Mitsubishi Electric, the company which has used<br />

its impressive controller device line-up in<br />

realizing high precision FA support, the <strong>WS</strong><br />

(World Super) <strong>Series</strong> of next generation molded<br />

case circuit breakers and earth-leakage circuit<br />

Long service life and high reliability,<br />

made possible by new equipment breakthroughs.<br />

Compliance with th<br />

The quest for truly superb breaker function, realizing<br />

performance at a full class higher.<br />

1


<strong>WS</strong> <strong>Series</strong>, Satisfying<br />

the Global Standard<br />

breakers. This series complies with IEC and<br />

UL/CSA, JIS standards, achieving a stellar level<br />

of globalization to satisfy genuine international<br />

needs. A product line-up designed with the<br />

environment in mind, together with the pursuit of<br />

easy usage and high performance to forge the<br />

way to a bright new future for breakers.<br />

Product design for greater easy usage,<br />

through wide variations.<br />

e global standards.<br />

New system configuration,<br />

on the strength of intelligent breakers.<br />

INDEX<br />

Features........................................................... 3<br />

The Great Variable Accessories for<br />

Perfect Solution............................................ 9<br />

1. <strong>Series</strong> Configuration and Listed of<br />

Product Models........................................ 11<br />

2. Detailed Specifications ............................ 13<br />

Molded-Case Circuit Breakers................. 13<br />

Earth-Leakage Circuit Breakers...............17<br />

Motor-Protection Breakers....................... 19<br />

UL Listed Products .................................. 20<br />

3. MDU Breakers........................................... 21<br />

4. Connection Method.................................. 22<br />

5. Accessories<br />

Internal Accessories.................................23<br />

External Accessories ...............................30<br />

6. Characteristics and Dimensions.............33<br />

7. Ordering Information................................62<br />

2


NEW21 Century Global Standard<br />

MITSUBISHI World Super <strong>Series</strong> Designed for Global Application<br />

ASTA<br />

EN<br />

CSA<br />

GB<br />

CCIB<br />

JIS<br />

UL<br />

TPC<br />

IEC<br />

SABS<br />

TUV<br />

LR<br />

GL<br />

DNV<br />

ABS<br />

BV<br />

NK<br />

Complete change in Mitsubishi<br />

breaker design colors<br />

Complete color change to ivory from<br />

<strong>WS</strong> <strong>Series</strong>. Use of shift to white<br />

breakers and more stylish design to<br />

boost attention on the international<br />

market.<br />

Complying with the various<br />

world standards<br />

Besides obvious conforming<br />

standards of IEC, UL, CSA and JIS,<br />

third-party certification and ship<br />

classification standards will also be<br />

obtained in each country, to<br />

respond to the world market.<br />

(Refer to the left entries for more<br />

details.)<br />

Raise each rating to address the<br />

international market.<br />

(1) NF30-SP => NF32-SW<br />

(2) NF60-HP => NF63-HW<br />

(3) NF100-SP => NF125-SW<br />

<strong>WS</strong> <strong>Series</strong> International Standard Conformance List<br />

IEC<br />

JIS<br />

EN<br />

Safety Certification<br />

UL CSA<br />

LR<br />

GL<br />

Marine Approvals<br />

DNV ABS<br />

BV<br />

NK<br />

Standards<br />

International<br />

Japan<br />

Europe<br />

USA<br />

Canada<br />

UK<br />

Germany<br />

Norway<br />

USA<br />

France<br />

Japan<br />

<strong>WS</strong><br />

● ● ● K K K K K<br />

<strong>Series</strong><br />

(Notes) “●” responds with standard item. “K” will manufacture according to instructions.<br />

K<br />

K<br />

K<br />

3


Targets one-class higher performance, in realizing superb<br />

breaking performance<br />

The <strong>WS</strong> <strong>Series</strong> presents a new technology.<br />

Relay<br />

• Interchangeable Relay-unit<br />

Thermal type Electronic type<br />

• AC/DC common use<br />

• T/A adjustable range is expanded.<br />

JPT<br />

Mechanism<br />

• Isolation suitability<br />

• Class II insulation<br />

• Extending operating cycles<br />

Breaking Performance<br />

• Increased Icu<br />

• High voltage<br />

• Ics=100% Icu<br />

• Co-ordination type “2”<br />

Terminal<br />

• IP20 Mold-cover Finger<br />

protection<br />

• Front compression<br />

terminalBox terminal<br />

RearPM<br />

Internal Accessories Shunt-less Advanced ISTAC PA Auto-Puffer External Accessories<br />

• Cassette-type accessories<br />

• Electric operators<br />

• Wide range of Rated<br />

q High speed type<br />

Voltage<br />

w Isolation suitability<br />

• IP20 PM with Safety Device<br />

• Handle Lock Device<br />

• R/V handle<br />

• IP40 Terminal cover<br />

[PA Auto-Puffer]<br />

[JPT]<br />

Adopted on SGW,<br />

Adopted on SGW,<br />

Polymer Ablation type Auto-Puffer [ Jet Pressure Trip Mechanism<br />

HGW, RGW, UGW] [ HGW, RGW, UGW]<br />

PA auto-puffer is the technology to increase the<br />

interrupting performance by blowing out the gas to the<br />

arc by right angle. The gas pressure which is generated<br />

from high-polymer materials is accumulated in the<br />

accumulating space, and the gas is blown to the arc to<br />

extinguish. Especially this technology improves the high<br />

voltage breaking performance.<br />

Unit case<br />

movable<br />

conductor<br />

eGas flow<br />

Arc<br />

Ablation gas jet through the hole installed on the unit<br />

case directly activates the trip mechanism. This acts<br />

faster than the relay (magnet), and contributes to<br />

improved current-limiting performance and breaking<br />

reliability.<br />

Trip Bar<br />

Tripping actuator to<br />

push the trip-bar<br />

before the trip by<br />

relay unit.<br />

Tripping Actuator<br />

Unit Case<br />

When short circuit<br />

fault occurs, the<br />

contacts are opened<br />

and arc is generated<br />

between the contacts.<br />

At that time the<br />

pressure in the unit<br />

case become very<br />

high.<br />

Extinguishing<br />

unit<br />

wAccumulating space<br />

qAblation<br />

Fixed conductor<br />

Arc Extinguishing Concept<br />

VJC insulation<br />

(high polymer materials)<br />

qAblation => wGas accumulating => eGas flow => Arc extinguishing<br />

Hole<br />

High pressure gas<br />

blows through the<br />

hole to rotate the<br />

tripping actuator<br />

4


Targets one-class higher performance, in realizing superb<br />

breaking performance<br />

[Advanced ISTAC] Advanced Impulsive Slot-Type Accelerator<br />

Adopted on SGW,<br />

[ HGW, RGW, UGW]<br />

Further evolution in Mitsubishi original ISTAC breaking technology*. Optimization of the current path and the added<br />

magnetic core enhance driving electromagnetic forces. By the high-speed opening and the arc driving, the rising rate<br />

of arc voltage is increased and the peak current “Ip “ is decreased.<br />

*The triple forces which are the repulsive force, the attractive force, and the pressure accelerate the separating speed of the movable conductor.<br />

Repulsive force<br />

Movable contact<br />

<br />

Attractive force<br />

<br />

current A<br />

current C<br />

current<br />

Upper,<br />

fixed-contact<br />

conductor<br />

Pressure<br />

<br />

Movable contact<br />

Movable contact VJC<br />

current B<br />

Lower,<br />

fixed-contact<br />

conductor<br />

Arc<br />

Fixed contact VJC<br />

(1) Electromagnetic attractive force between Current A and Current C<br />

(2) Electromagnetic repulsive force between Current B and Current C<br />

(3) Ablation gas pressure<br />

These three forces<br />

generated high-speed drive<br />

Breaking Capacity Icu/Ics<br />

<br />

Max. Iet-through peak current (kA)<br />

(400VAC)<br />

(kA)<br />

200<br />

150<br />

100<br />

50<br />

0<br />

85<br />

100<br />

125 125 125<br />

36<br />

200 200 200<br />

75 75<br />

36<br />

36<br />

230VAC 380VAC 400VAC 415VAC<br />

70<br />

125<br />

200<br />

36<br />

65<br />

200 200<br />

125 125<br />

30<br />

50<br />

8<br />

440VAC 500VAC 690VAC<br />

20<br />

30<br />

25<br />

U(UGW)<br />

R(RGW)<br />

H(HGW)<br />

S(SGW)<br />

<strong>Series</strong><br />

MAX. peak carrent (kA)<br />

MAX.I 2 t (A 2 .sec)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Short-Circuit Current, sym.r.m.s.(kA)<br />

I 2 t let-through characteristics (400VAC)<br />

<br />

Prospective short-circuit<br />

current asym.peak<br />

NF250-HGW<br />

NF250-UGW<br />

NF250-HGW<br />

NF250-UGW<br />

<br />

Short-Circuit Current, sym.r.m.s. (kA)<br />

[Shunt-less]<br />

Shunt-less Current Flow Technology<br />

Adopted on SGW,<br />

[ HGW, RGW, UGW]<br />

Double plates conductors hold the movable conductor without flexible<br />

wires.This shunt-less structure achieves the extending operating<br />

cycles.<br />

Holder<br />

Movable contact<br />

Endurance<br />

(C-O cycles)<br />

(times)<br />

50,000<br />

40,000<br />

Electrical<br />

Mechanical<br />

30,000<br />

20,000<br />

10,000<br />

0<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

Spring<br />

Movable contact<br />

revolving shaft<br />

During revolution the movable contact is constantly<br />

in contact with the holder, maintaining current flow.<br />

5


I<br />

Product design which pursues greater use ease by wide variations<br />

Interchangeable Relay Unit<br />

To enhance flexibility, the Mitsubishi<br />

<strong>WS</strong> <strong>Series</strong> is equipped with<br />

interchangeable relay units (available<br />

in thermal or electronic types).<br />

The move has been made to<br />

AC/DC common use, while the<br />

expanded adjustment range enables<br />

reduction in the number of 250AF<br />

relays from 10 to 7 types.<br />

A magnetic adjustable function has<br />

been added to the thermal type,<br />

while 4P neutral protection has also<br />

been enhanced.<br />

(Note: Only authorized members<br />

available to replace)<br />

Thermal type unit<br />

4 10<br />

Electronic type unit<br />

Thermal Adjustable Relay<br />

6 8<br />

Ii(DC)=1.3XIi(AC) 4 10<br />

Ii(X250A AC)<br />

T<br />

Ir<br />

Ii<br />

MODEL<br />

RT<br />

250<br />

In 250 A<br />

50/60Hz<br />

40 3P3E<br />

160<br />

200<br />

Ir(A)<br />

250<br />

MADE IN JAPAN<br />

LN326N433-1<br />

Rating<br />

Type<br />

In (A)<br />

NF250-SGW / HGW<br />

NF160-SGW / HGW<br />

NF125-SGW / HGW<br />

Tripping threshold Ir (A)<br />

(note 1)<br />

Neutral protection<br />

4P 3E<br />

4P 4E<br />

25 40 63 100 125 160 250<br />

● ●<br />

●<br />

● ● ● ● ●<br />

Overload Protection (Thermal)<br />

Adjustable<br />

16-25 25-40 40-63 63-100 80-125 125-160<br />

No Protection<br />

1 × Ir<br />

160-250 (160-225)<br />

Tripping threshold Ii<br />

Short-Circuit Protection (Magnetic)<br />

Fixed<br />

10 × In<br />

Adjustable<br />

4 to 10 × In<br />

Note: (1) The type 4P 3E is standard. If the type 4P 4E is required, specify the type 4P 4E separately and explicitly.<br />

Ir Ii I<br />

Electronic Relay<br />

LN326N429-11<br />

MODEL<br />

T<br />

Ir<br />

MADE IN JAPAN<br />

Ip<br />

TL<br />

RE250 In<br />

250<br />

A<br />

Is<br />

AC only<br />

50/60Hz<br />

Ii 70% PAL<br />

Ts<br />

Ir (A) TEST T L(s) Is (XIr) Ts (s)<br />

Ip (XIr)<br />

200<br />

80<br />

4 5<br />

160<br />

60<br />

3.5<br />

6<br />

2 Ii (X250A) 8<br />

85<br />

1<br />

10<br />

8<br />

9<br />

3<br />

7<br />

6<br />

12<br />

95<br />

2.5<br />

8<br />

75<br />

125<br />

250 12 100 2 10 06<br />

3 4 14 7<br />

1.0<br />

OVER<br />

I pN<br />

4P3E 4P4E<br />

Rating In (A) (40°C)<br />

NF250-SGW / HGW<br />

Type NF160-SGW / HGW<br />

NF125-SGW / HGW<br />

LTD<br />

Tripping threshold Ir (A)<br />

Tripping time<br />

TL(s)<br />

Neutral protection (Slectable)<br />

32 63 100 125 160 250<br />

●<br />

●<br />

● ● ● ●<br />

Overload Protection<br />

Adjustable<br />

16-32 32-63 63-100 75-125 80-160 125-250<br />

12-60-80-100 step adjustable (at 2 × Ir)<br />

0-1 × Ir (Step adjustable)<br />

T<br />

Ip<br />

TL<br />

Ir<br />

Is<br />

Ts<br />

Ii<br />

I<br />

STD<br />

INST<br />

PAL<br />

Pickup current Is<br />

Tripping time Ts(s)<br />

Tripping threshold Ii<br />

Pickup current Ip<br />

Operating time Tp<br />

70%-LED (green)<br />

PAL-LED (orange)<br />

Over -LED (red)<br />

Short-Circuit Protection<br />

2-2.5-3-3.5-4-5-6-7-8-10 × Ir step adjustable<br />

0.06-0.1-0.2-0.3 step adjustable (at 1.5 × Is)<br />

4 to 14 × In continuous adjustable<br />

Pre-Alarm<br />

0.7-0.75-0.8-0.85-0.9-0.95-1.0 × Ir step adjustable<br />

TL/2<br />

Indicator (LED)<br />

Lit at 0.7 × Ir<br />

Flashing at lp and lit at Tp<br />

Lit at 1.15 × Ir<br />

6


Product design which pursues greater use ease by wide variations<br />

Internal Accessories<br />

Adopted for the internal accessories is a easily installed<br />

cassette type. Common use of different voltages realizes major<br />

reductions in types.<br />

The UVT for ELCB is also possible. Time delay type variations<br />

have also been expanded, addressing a wide range of applications.<br />

3 Way Lead Wire (Selectable)<br />

Prebius madels<br />

<strong>WS</strong> <strong>Series</strong> (New)<br />

Vertical Lead-wire Terminal Block (SHT)<br />

SHT<br />

voltuge<br />

AC (V)<br />

DC (V)<br />

(24), (48), 100-120, 200-240,<br />

380-450, (440-550)<br />

(12), (24), (36), (48), 100, (110), (125), (220)<br />

24-48, 100-240, 380-550<br />

12, 24-36, 36-48, 100-125, (220-250)<br />

UVT<br />

voltuge<br />

AC (V)<br />

DC (V)<br />

100-110, (100-120), 200-220, (220-240),<br />

(380-415), 400-440, (440-480), (500-550)<br />

(24), (48), 100, (110)<br />

24/48, 100-110/120-130, 200-220/230-250,<br />

380-415/440-480, 500-550<br />

24/48, 100-110, 110-125<br />

Lead-wire to Line side<br />

Flying Lead-wire<br />

∗Cassette-type Accessories<br />

Cassette-type accessories ensure flexbility when upgrading<br />

circuits.<br />

Ordering is easy, and installation is one touch simple and<br />

safe too thanks to the insulated cassette design.<br />

Fits all breaker series<br />

The alarm switch (AL), auxiliary switch (AX), shunt trip (SHT),<br />

and undervoltage trip (UVT) all comes as cassette-type<br />

accessories to suit all breaker series.<br />

1. Push the trip button<br />

(PPT) to the breaker<br />

2. Loosen the front<br />

cover screws<br />

3. Open the front<br />

cover<br />

4. Install the<br />

accessories<br />

5. Close the front cover<br />

and tighten the screws.<br />

External Accessories<br />

Hight speed Motor Device<br />

Supplied for the 125 through 250AF is a motor device easier to use,<br />

which simplifies installation.<br />

∗Adoption of a spring charge mechanism for high-speed operation<br />

(0.05~0.1seconds)<br />

∗Swift and simple installation, by tightening only two screws.<br />

Power Supply Module<br />

External Handle<br />

Adoption of a safer and easy to operate handle.<br />

∗Complying with protection degree IP65.<br />

∗Isolation function achieved through combination with the breaker unit.<br />

∗Structured to allow relay adjustments after installation as well.<br />

∗Equipped with cylinder key (option) to prevent deliberate operation.<br />

V-Handle<br />

R-Handle<br />

IP-20PM with Safety Device<br />

Specialized for 3-and4-poles use (2 pole incompatible).<br />

∗Complies with protection degree IP20.<br />

∗Safety device supplied as option.<br />

∗May be connected with up to nine leads (for PLT).<br />

∗May be modified from front connection to rear connection.<br />

(Note: Modification by end users not authorized)<br />

IP20: Finger protection.<br />

7<br />

(IP-20PM)


Product design which pursues greater use ease by wide variations<br />

IP-20 Terminal Connection<br />

With the SGW, HGW,<br />

connection safety has been<br />

further elevated.<br />

∗Standard IP-20 protection<br />

degree secured.<br />

Terminal Cover<br />

Major improvements have been made in<br />

front connection terminal safety.<br />

∗With terminal covers, IP40 protection<br />

degree is ensured.<br />

Variable Connections<br />

Compatible with various<br />

connection methods.<br />

Solderless terminals<br />

extending outside the<br />

breaker unit on the<br />

conventional type have<br />

been upgraded to a<br />

built-in internal type (see<br />

Diagram 2). Maximum connecting Cable of 185mm 2<br />

(SGW/HGW).<br />

(Note: Certain models have externally attached terminals)<br />

IEC Rail Mounting for 32, 63AF<br />

The 32,63AF includes installation<br />

hooks to IEC rails as standard<br />

equipment, greatly simplifying<br />

installation work.<br />

Handle Locks<br />

With the <strong>WS</strong> <strong>Series</strong>, ON/OFF locking<br />

is possible through the padlock to the<br />

breaker unit.<br />

Up to three padlocks may be attached.<br />

∗Customers are requested to supply<br />

their own padlocks<br />

ON Lock<br />

OFF Lock<br />

OFF Lock with 3 Padlock<br />

New system configuration through the use of an intelligent breaker<br />

AE-SS MDU <strong>WS</strong>S MDU Eco Monitor<br />

Data Measuring & Transmission<br />

Working through a sequence CC-Link interface unit makes it possible to<br />

collect electrical circuit measuring data.<br />

MELSECNET/10 or Other or upper Other busupper bus<br />

MITSUBISHI MDU (Measuring Display Unit) Breaker<br />

• AE1600-SS US3 Relay with CC-Link<br />

• NF250-SWM with CC-Link<br />

CC-Link<br />

CC-LINK<br />

Interface unit<br />

BIF-C<br />

CC-Link<br />

Interface unit<br />

BIF-C<br />

AE1600-SS<br />

Setting Infomation<br />

Rated current max :Inmax 1600 A<br />

Rated current max :(xinmax) 80 %<br />

Uninterrupted curr :Iu(xin) 80 %<br />

PAL pick-up :IP(xin) 70 %<br />

STD pick-up :Isd(xin) 600 %<br />

LTD Time :TL 100 sec<br />

STD Time :TS 0.5 %<br />

Inst Pickup :Ii(xin) 1600 %<br />

ON<br />

Alarm<br />

1050 A<br />

PAL<br />

465 V<br />

OVER<br />

654321 kWh<br />

Trip(L)<br />

567 kVarh Trip(S)<br />

85 %(PF) Trip(I)<br />

60 Hz<br />

Trip curent 0kA<br />

80 A(Hamonics)<br />

NF250-SWM<br />

321 A<br />

450 V<br />

123456 kWh<br />

90 %(PF)<br />

LOAD<br />

Alarm<br />

PAL<br />

OVER<br />

Trip(L)<br />

Trip(S/I)<br />

LOAD<br />

8


The Great Variable Accessories for Perfect Solution<br />

250AF Product Skelton<br />

⁄0<br />

⁄6<br />

⁄1<br />

¤2<br />

⁄7<br />

m<br />

¤3<br />

⁄8<br />

¤4<br />

⁄9<br />

b<br />

v<br />

¤0<br />

m<br />

¤1<br />

⁄0<br />

⁄1<br />

9


⁄2<br />

⁄3<br />

z MCCB<br />

,<br />

x Relay unit (Thermal type) (RT)<br />

c Relay unit (Electronic type) (RE)<br />

.<br />

v Relay unit (Magnetic only type) (RM)<br />

b Relay unit (Switch-disconnector type)∗<br />

n Super current-limiting unit∗<br />

n<br />

m Solderless (Box) terminals<br />

, Front connection nuts<br />

. Rear connections<br />

⁄0 Insulating barrier (BA-F)<br />

⁄1 Small terminal cover (TC-S)<br />

z<br />

⁄5<br />

⁄4<br />

⁄2 Large terminal cover (TC-L)<br />

⁄3 Rear terminal cover (BTC)<br />

⁄4 Plug-in base (PM)<br />

⁄5 Connections for Plug-in<br />

⁄6 Mechanical interlock device (MI)<br />

⁄7 OFF Lock with 3 Padlock (HLF3)<br />

⁄8 Handle lock device (LC/HLF/HLN/HLS)<br />

⁄9 Variable-depth operating handle (V type)<br />

¤0 Rotary operating handle (R type)<br />

¤1 Electrical operation device (MD)<br />

c<br />

¤2 Alarm/Auxillary switch device (AL/AX)<br />

¤3 Under voltage trip device (UVT)<br />

x<br />

¤4 Shunt trip device (SHT)<br />

,<br />

.<br />

Note ∗: All the accessories are field mounting type<br />

except No.5 and 6.<br />

⁄2<br />

⁄3<br />

10


1. <strong>Series</strong> Configuration and List of Product Models<br />

<strong>Series</strong> Configuration<br />

Molded-case circuit breakers<br />

NF-C<br />

Economy type<br />

NF-S<br />

Standard type<br />

NF-H<br />

High-performance<br />

type<br />

NF-U<br />

Current limiting-type<br />

ultra breaker<br />

Earth-leakage circuit breakers<br />

NV-C<br />

Economy type<br />

NV-S<br />

Standard type<br />

NV-H<br />

High-performance<br />

type<br />

NV-U<br />

Ultra current-limiting<br />

type<br />

Motor-protection breakers<br />

MB<br />

Motor breaker<br />

Miniature circuit breakers<br />

BH BH-P BH-S BH-PS BH-D6 BV-D KB-D<br />

NEMA-type for consumer unit<br />

DIN-series for general consumer unit<br />

Circuit protectors<br />

CP30-BA CP-B CP-S<br />

For equipment<br />

11


List of Product Models<br />

( The models shown in shaded boxes are <strong>WS</strong> series.)<br />

<strong>Series</strong><br />

NF-C<br />

Economy type<br />

Molded-case circuit breaker<br />

Earth-leakage circuit breaker<br />

Motor-protection<br />

braker<br />

NF-S<br />

Standard type<br />

NF-H<br />

High-performance type<br />

NF-U<br />

Ultra current-limiting type<br />

NV-C<br />

Economy type<br />

NV-S<br />

Standard type<br />

NV-H<br />

High-performance type<br />

NV-U<br />

Ultra current-limiting type<br />

MB<br />

Motor breaker<br />

Frame A<br />

32 (30) 63 125 (100) 160 250 400 630 800 1000 1250 (1200) 1600 2000 2500 (3200) 4000<br />

NF30-CS NF63-CW NF125-CW NF250-CW NF400-CP NF630-CP NF800-CEP<br />

NF32-SW<br />

NF63-SW<br />

NF63-HW<br />

NF125-SW NF160-SW NF250-SW NF400-SP NF630-SP NF800-SDP<br />

NF1000-SS<br />

(NF1200-SS) NF1250-SS NF1600-SS NF2000-S NF3200-S NF4000-S<br />

NF125-SGW NF160-SGW NF250-SGW NF400-SEP NF630-SEP NF800-SEP<br />

NF2500-S<br />

NF125-HW NF160-HW NF250-HW NF400-HEP NF630-HEP NF800-HEP<br />

NF1000-SSD NF1250-SSD NF1600-SSD NFE2000-S NFE3000-S NFE4000-S<br />

NF125-HGW NF160-HGW NF250-HGW NF400-REP NF630-REP NF800-REP<br />

NF125-RGW NF250-RGW NF400-UEP NF630-UEP NF800-UEP NF1250-UR<br />

NF125-UGW<br />

NF250-UGW<br />

NV30-CS NV63-CW NV125-CW NV250-CW NV400-CP NV630-CP<br />

NV32-SW<br />

MB30-CS<br />

MB30-SW<br />

NV63-SW<br />

NV63-HW<br />

MB50-CW<br />

MB50-SW<br />

NV125-SW NV250-SW NV400-SP NV630-SP<br />

NV800-SEP<br />

NV100-SEP NV250-SEW NV400-SEP NV630-SEP<br />

NV1000-SB<br />

NV125-HW NV250-HW NV400-HEP<br />

NV800-HEP<br />

NV630-HEP<br />

NV100-HEP NV250-HEW NV400-REP<br />

NV125-RW<br />

MB100-SW<br />

NV250-RW<br />

MB225-SW<br />

NV1200-SB<br />

NF-UL<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

UL listed products<br />

NV-UL<br />

Earth-leakage protector<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

<strong>Series</strong><br />

UL listed<br />

products<br />

Frame A<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

Earth-leakage protector<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

Details will be available<br />

( upon request. )<br />

50 100 150 225 250 400 600<br />

NF50-SWU NF100-CWU NF-SFW NF225-CWU NF-SJW NF-SKW NF-SLW<br />

NF100-SWU<br />

NF-HJW<br />

NV50-SWU NV100-SWU NV225-CWU<br />

: Released in April 2001<br />

: Scheduled to be released in October 2001<br />

Details will be available<br />

( upon request. )<br />

: Available soon<br />

Miniature Circuit Breaker<br />

AF 60 100<br />

BH<br />

BH-P<br />

BH<br />

BH-S —<br />

BH-PS —<br />

DIN <strong>Series</strong><br />

AF<br />

MCB<br />

RCCB<br />

RCBO<br />

Isolating<br />

switch<br />

63 and less<br />

BH-D6<br />

BV-D<br />

BV-DN<br />

KB-D<br />

Circuit Protectors<br />

AF 30 and less<br />

CP30-BA<br />

CP CP-B<br />

CP-S<br />

12


2. Detailed Specifications<br />

Molded-Case Circuit Breakers<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Available soon Available soon Available soon Available soon<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

’<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

b<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽ –<br />

–<br />

–<br />

–<br />

–<br />

–<br />

✽ –<br />

–<br />

–<br />

–<br />

–<br />

–<br />

– – – – –<br />

<br />

<br />

<br />

<br />

– –<br />

<br />

<br />

<br />

<br />

<br />

<br />

– –<br />

– – – – – – –<br />

–<br />

– <br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

– – – – – <br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

<br />

<br />

✽<br />

<br />

<br />

✽<br />

<br />

<br />

a<br />

ca c<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

– –<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

2.5/1<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

2<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

4<br />

–<br />

–<br />

–<br />

–<br />

–<br />

13


14<br />

<br />

<br />

<br />

<br />

<br />

<br />

8/4<br />

18/5<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

10/5<br />

22/11<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–25––<br />

––125<br />

<br />

–<br />

<br />

8/8<br />

22/22<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

– –<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–32–<br />

––125<br />

<br />

<br />

<br />

<br />

8/8<br />

22/22<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

– –<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–25––<br />

––125<br />

<br />

<br />

20/20<br />

35/35<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–32–<br />

––125<br />

<br />

<br />

<br />

<br />

20/20<br />

35/35<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

8/8<br />

22/22<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

8/8<br />

22/22<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽ ✽ ✽<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

– <br />

–<br />

4<br />

<br />

2 4<br />

<br />

2 4<br />

<br />

2 4<br />

<br />

2 4<br />

<br />

2 4<br />

<br />

2<br />

20/20✽ 40/40✽ 20/20✽<br />

<br />

– <br />

–<br />


2. Detailed Specifications<br />

Molded-Case Circuit Breakers<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

’<br />

<br />

<br />

<br />

✽ <br />

<br />

<br />

✽ –<br />

–<br />

<br />

–<br />

–<br />

<br />

– – <br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

– – – – – –<br />

– – – – – –<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

– – – – – –<br />

<br />

– – – – – –<br />

– – – – – –<br />

– – – – – –<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

<br />

<br />

<br />

<br />

✽<br />

<br />

<br />

<br />

a<br />

<br />

✽<br />

b<br />

ca c<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

5/3<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

20/20<br />

35/35<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

–160<br />

✽<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–160<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–160160–250<br />

<br />

–250<br />

<br />

<br />

<br />

20/20<br />

35/35<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

8/8<br />

22/22<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

8/8<br />

22/22<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

✽<br />

–<br />

–<br />

–<br />

–<br />

✽<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

–<br />

1,000<br />

1,000<br />

1,000<br />

–<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

15


16<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

5/3<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–160160–250<br />

<br />

<br />

20/20<br />

35/35<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–250<br />

<br />

–<br />

<br />

20/20<br />

35/35<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–25 25–40<br />

40–63 63–100<br />

<br />

<br />

<br />

<br />

25/25<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–25 25–40<br />

40–63 63–100<br />

<br />

<br />

30/30<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

––225<br />

<br />

<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

––225<br />

<br />

<br />

30/30<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1,000<br />

1,000<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

✽ –<br />

✽ ✽ ✽ ✽<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

4<br />

<br />

2 4<br />

<br />

2 4<br />

<br />

2 4<br />

<br />

2<br />

<br />


2. Detailed Specifications<br />

Earth-Leakage Circuit Breakers<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Available soon Available soon Available soon Available soon<br />

<br />

°C)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

a ca c<br />

<br />

<br />

<br />

b<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

’<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

–<br />

–<br />

–<br />

Button<br />

2.5/1<br />

5/2<br />

5/2<br />

7.5/4<br />

10,000<br />

6,000<br />

6,000<br />

75<br />

130<br />

68<br />

90<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

• •<br />

Button<br />

10/5<br />

10/5<br />

–<br />

30/15<br />

10,000<br />

6,000<br />

6,000<br />

90<br />

130<br />

68<br />

90<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

• •<br />

Button<br />

15/8<br />

18/9<br />

–<br />

35/18<br />

8,000<br />

4,000<br />

4,000<br />

105<br />

165<br />

68<br />

92<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

–<br />

–<br />

Button<br />

5/2<br />

5/2<br />

5/2<br />

10/5<br />

10,000<br />

6,000<br />

6,000<br />

75<br />

130<br />

68<br />

90<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

– – –<br />

– – –<br />

– –<br />

– – –<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

✽<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

–<br />

–<br />

–<br />

Button<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

15/8<br />

15,000<br />

15,000<br />

8,000<br />

75<br />

130<br />

68<br />

90<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

–<br />

–<br />

–<br />

Button<br />

10/5<br />

10/5<br />

10/5<br />

25/13<br />

15,000<br />

15,000<br />

8,000<br />

75<br />

130<br />

68<br />

90<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–400–440V<br />

–484V<br />

17


–225<br />

<br />

<br />

<br />

–225<br />

<br />

<br />

<br />

<br />

✽<br />

<br />

<br />

<br />

<br />

<br />

Adjustable<br />

<br />

<br />

<br />

Adjustable<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

• •<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

• •<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

0.1 •0.5 •1.0<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

0.1 •0.5 •1.0<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

0.1 •0.5 •1.0<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

0.1 •0.5 •1.0<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

0.1 •0.5 •1.0<br />

Button<br />

–400–440<br />

<br />

• •<br />

<br />

<br />

• •<br />

<br />

• •<br />

<br />

0.1 •0.5 •1.0<br />

Button<br />

25/13<br />

30/15<br />

–<br />

50/25<br />

25,000<br />

20,000<br />

10,000<br />

50/25<br />

50/25<br />

–<br />

100/50<br />

25,000<br />

20,000<br />

10,000<br />

25/13<br />

30/15<br />

–<br />

50/25<br />

12,000<br />

4,000<br />

4,000<br />

25/13<br />

30/15<br />

–<br />

50/25<br />

12,000<br />

4,000<br />

4,000<br />

50/13<br />

50/13<br />

–<br />

100/25<br />

12,000<br />

4,000<br />

4,000<br />

50/13<br />

50/13<br />

–<br />

100/25<br />

12,000<br />

4,000<br />

4,000<br />

125/125<br />

125/125<br />

–<br />

125/125<br />

25,000<br />

20,000<br />

10,000<br />

125/125<br />

125/125<br />

–<br />

125/125<br />

12,000<br />

4,000<br />

4,000<br />

90 120 90 120 105 140 105 140 105 140 105 140<br />

90<br />

105<br />

130<br />

68<br />

90<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

130<br />

68<br />

90<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

165<br />

68<br />

92<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

165<br />

68<br />

92<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

165<br />

68<br />

92<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

165<br />

68<br />

92<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

191<br />

68<br />

90<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

240<br />

68<br />

92<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

– –<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

–<br />

<br />

–<br />

<br />

<br />

<br />

–<br />

– – – –<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

– – – –<br />

–<br />

–<br />

–<br />

–<br />

– – – – – –<br />

–<br />

–<br />

– – – – – –<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

–<br />

–<br />

–<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

18


2. Detailed Specifications<br />

Motor-Protection Breakers<br />

30 50 100 225<br />

MB30-SW MB50-CW MB50-SW<br />

Type name<br />

MB100-SW<br />

MB225-SW<br />

Available soon Available soon Available soon<br />

Rated current In (Amp.)<br />

Rated motor capacity: kW<br />

Reference ambient temperature 40°C<br />

(45°C for marine applications)<br />

A<br />

200/220V 400/440V<br />

kW kW<br />

25 5.5 11<br />

16 3.7 7.5<br />

12 5.5<br />

10 2.2 <br />

8 3.7<br />

7.1 1.5 <br />

5 2.2<br />

4 0.75 1.5<br />

2.5 0.4 <br />

2 0.75<br />

1.4 0.2 <br />

1.2 0.4<br />

0.8 <br />

200/220V 400/440V<br />

A<br />

kW kW<br />

45 11 22<br />

40 18.5<br />

32 7.5 15<br />

25 5.5 11<br />

16 3.7 7.5<br />

12 5.5<br />

10 2.2 <br />

8 3.7<br />

200/220V 400/440V<br />

A<br />

kW kW<br />

7.1 1.5 <br />

5 2.2<br />

4 0.75 1.5<br />

2.5 0.4 <br />

2 0.75<br />

1.4 0.2 <br />

1.2 0.4<br />

0.8 <br />

A<br />

200/220V 400/440V<br />

kW kW<br />

100 55<br />

90 22 45<br />

71 18.5 37<br />

63 15 30<br />

45 11 22<br />

(40) 19<br />

32 7.5 15<br />

(25) 5.5 11<br />

(16) 3.7 7.5<br />

(12.5) 5.5<br />

200/220V 400/440V<br />

A<br />

kW kW<br />

225 55 110<br />

200 <br />

175 45 90<br />

150 37 75<br />

125 30 <br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated shortcircuit<br />

breaking<br />

capacities (kA)<br />

Overall<br />

dimensions<br />

(mm)<br />

lEC60947-2<br />

JIS C 8201-2<br />

(lcu/lcs)<br />

a<br />

b<br />

ca c<br />

AC<br />

3 3 3 3 3<br />

500 500 500 500 500<br />

440V 2.5/1 2.5/1 7.5/4 25/13 25/13<br />

400V 7.5/4 7.5/4 7.5/4 30/15 30/15<br />

230V 7.5/4 7.5/4 15/8 50/25 50/25<br />

a 75 75 75 90 105<br />

b 130 130 130 130 165<br />

c 68 68 68 68 68<br />

ca 90 90 90 90 92<br />

Connection<br />

method<br />

Front connection<br />

Rear connection<br />

Plug-in<br />

(F)<br />

(B)<br />

(PM)<br />

● Crimp contact ● Crimp contact ● Crimp contact ● Crimp contact ● Crimp contact<br />

● Round stud ● Round stud ● Round stud ●Bar stud ●Bar stud<br />

Remark: The products of which rated current is parenthesized will be produced when an order is placed.<br />

● ● ● ● ●<br />

19


2. Detailed Specifications<br />

UL Listed Products<br />

Frame A<br />

Type name<br />

100 225 50 100 150 250<br />

NF100-CWU NF225-CWU NF50-SWU NF100-SWU NF-SFW NF-SJW NF-HJW<br />

Photo<br />

Available soon<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

506075100<br />

125150175<br />

200225<br />

5101520<br />

304050<br />

15203040<br />

506075100<br />

1520304050<br />

60708090 100<br />

110125150<br />

(125)(150)175<br />

200225250<br />

125150175<br />

200225250<br />

Number of poles<br />

2 3 3 2 3 2 3<br />

3 3 3<br />

Rated short-circuit breaking capacities (kA)<br />

UL489<br />

JIS C 8201-2<br />

IEC60947-2<br />

(Icu/Ics)<br />

Rated voltage (V AC) 240 240 240 480Y/277 600Y/347 600Y/347 600Y/347<br />

600Y/347V 14 14 18<br />

AC<br />

480V 35 35 50<br />

480Y/277V 22 35 35 50<br />

240V 10 35 10 35 65 65 100<br />

Rated insulation voltage Ui (V) 600 600 600 690 690 690 690<br />

690V 84 88 88 1515<br />

500V 7.54 105 7.54 189 3030 3030 3636<br />

440V 105 158 7.54 2513 3636 3636 5050<br />

AC 415V 105 189 7.54 3015 3636 3636 5050<br />

400V 105 189 7.54 3015 3636 3636 5050<br />

380V 105 189 7.54 3015 3636 3636 5050<br />

230V 3015 3518 158 5025 8585 8585 100100<br />

DC 250V ✽ 7.54 105 158 2020 2020 2020<br />

Compatible to AC/DC ✽ ● ● ● ● ● ●<br />

Suitability for isolation<br />

● ● ● ● ● ● ●<br />

Reverse connection<br />

● ● ● ● ● ● ●<br />

a 60 90 105<br />

50 75 60 90 105 105 105<br />

Overall<br />

dimensions<br />

(mm)<br />

a<br />

b<br />

ca c<br />

b 150 165 150 150 185 185 185<br />

c 68 68 68 68 86 86 86<br />

ca 90 92 90 90 110 110 110<br />

Mass of front-face type (kg)<br />

0.7 0.95<br />

1.5<br />

0.55<br />

0.75 0.7 0.95 2.0 2.0 2.0<br />

Connection<br />

method<br />

Accessories ✽<br />

External accessories ✽<br />

Front<br />

connection<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

Under-voltage trip<br />

Vertical lead-wire terminal unit<br />

Mechanical interlock<br />

Handle lock device<br />

Operating handle<br />

Crimp contact<br />

Solderless<br />

terminal<br />

Insulating barrier<br />

Terminal Large<br />

cover<br />

Small<br />

IEC 35mm rail fixture<br />

(F) ● ● ● ● ● ● ●<br />

(SL) ● ● ● ● ●<br />

(AL) ● ● ● ● ● ● ●<br />

(AX) ● ● ● ● ● ● ●<br />

(SHT) ● ● ● ● ● ● ●<br />

(UVT) ● ● ● ● ● ● ●<br />

(SLT) ● ● ● ● ● ● ●<br />

(MI) ● ● ● ● ● ● ●<br />

(HL) ● ● ● ● ● ● ●<br />

F ● ● ● ● ● ● ●<br />

S ● ● ● ● ● ● ●<br />

V ●<br />

● ● ●<br />

● ● ●<br />

(IB) ● ● ● ● ● ● ●<br />

(TC-L) ● ● ● ● ● ● ●<br />

(TC-S) ✽ <br />

<br />

Over current trip means<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Trip button<br />

TÜV type approval<br />

Equipped Equipped Equipped Equipped Equipped Equipped Equipped<br />

● ● ● ● ● ● ●<br />

Notes: ✽ The trip action characteristics differ between AC and DC for products that are compatible to both AC and DC.<br />

✽ Specifications for products with a CE mark differ from those for general-purpose products. Details will<br />

be available upon request.<br />

✽ Use two poles among the three poles in the case of three-pole products. In addition, wiring as shown to the<br />

right allows the models of NF100-CWU, NF100-SWU and NF225-CWU to be used for up to 400 V DC and<br />

the models of NF-SFW, NF-SJW, and NF-HJW to be used for up to 500 V DC.<br />

✽ The standard configuration contains a protection cover and adopts the IP20 (finger protection) structure.<br />

Remark: The products of which rated current is parenthesized will be produced when an order is placed.<br />

Line<br />

3-pole<br />

Load<br />

20


3. MDU Breaker (Measuring Display Unit)<br />

■Summary<br />

The circuit breaker incorporates a digital Measuring Display Unit<br />

(MDU). It can measure and display a range of circuit condition<br />

data for more efficient energy management.<br />

■Appearance<br />

■Features<br />

●Measuring and displaying the load current, line voltage,<br />

harmonic current, power, electric energy and power factor.<br />

●Direct connection to open network CC-Links is possible.<br />

●The measuring VT and CT are installed within the circuit breaker,<br />

thus offering savings on space and wiring.<br />

NF250-SWM 3P<br />

■MDU breaker product lineup and measuring display items<br />

Measurement and display items<br />

Load current for each phase: present value, demand value, maximum demand value<br />

Line voltage: present value<br />

Harmonic current: 3, 5, 7, 11, 13, 17, 19th, total harmonics<br />

Present value, demand value, maximum demand value<br />

Power: present value, demand value, maximum demand value<br />

Electric energy: electric energy, time electric energy, maximum time electric energy<br />

Power factor: present value<br />

Applicable type<br />

MCCB<br />

NF250-SWM<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

■Specifications<br />

<strong>Series</strong><br />

Group<br />

Frame size<br />

Type name<br />

Rated current In (Amp.)<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Supply system<br />

Rated insulation voltage Ui (V)<br />

Rated shortcircuit<br />

breaking<br />

capacities (kA)<br />

Connection<br />

IEC60947-2<br />

(Icu/Ics)<br />

Transmission (option) ✽<br />

Maximum measuring current (Amp.)<br />

Maximum measuring voltage<br />

MDU control power supply<br />

AC<br />

(50/60Hz)<br />

Pulse output<br />

CC-Link<br />

500V<br />

440V<br />

415V<br />

400V<br />

380V<br />

240V<br />

230V<br />

S series<br />

<strong>WS</strong>S MDU<br />

250<br />

NF250-SWM<br />

125 150 175 200 225 250<br />

40<br />

3, 4<br />

3ø3W, 1ø3W for 3 poles, 3ø4W for 4 poles (1ø2W available for 3 poles)<br />

690<br />

15/8<br />

25/13<br />

30/15<br />

30/15<br />

30/15<br />

50/25<br />

50/25<br />

Front type (F), Rear type (B) ✽<br />

Solid-state relay (SSR), no-voltage a contact, DC24V/AC100–200V 20mA<br />

Output pulse unit: 1–10–100–1000–10000kWh/pulse set, pulse width 0.35–0.45 sec.<br />

Load current, Line voltage, Harmonic current, Power, Electric energy, Power factor<br />

500<br />

690V AC<br />

(For 100–240V AC/DC, allowable voltage range: 85%~110%) 12VA (Use a fuse with a 4A rated current or larger) ✽<br />

Notes: ✽ <br />

✽ <br />

✽ <br />

21


4. Connection Method<br />

1. Connection Types<br />

Table 4-1: Connection Types<br />

Connection Method (Abbreviation) Front connection (F) Solderless terminal<br />

Rear connection (B)<br />

The front connection model will be delivered unless otherwise specified. Notice, however,<br />

that you can convert the front connection model to other types (excluding the plug-in) by<br />

using an appropriate connection component, which is separately available.<br />

Plug-in (PM)<br />

Appearance<br />

Note ✽Rear studs are bar studs for the models of 125A, 160A and 250A of frame size, and round studs for other types of models.<br />

✽<br />

2. Connection Accessories<br />

Table 4-2: List of Connection Accessories<br />

Type name<br />

NF32-SW, NF63-CW/SW/HW<br />

NF32-SW, MB30-SW, MB50-CW/SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW<br />

NF63-SW/HW<br />

NF125-CW/SW<br />

NF125-HW<br />

NF125-CW/SW/HW, MB100-SW, NV125-CW/SW/HW<br />

NF125-RW/UW, NV125-RW<br />

NF125-SW/HW/UW, NV125-SW/HW<br />

NF125-UW<br />

NF250-CW/SW/HW, NF160-SW/HW<br />

NF250-CW/SW/HW, MB225-SW, NF160-SW/HW, NV250-CW/SW/HW/RW/SEW/HEW<br />

NV250-RW<br />

NF250-SW/HW, NF160-SW/HW, NV250-SW/HW/SEW/HEW<br />

NF250-SGW/HGW, NF160-SGW/HGW, NF125-SGW/HGW<br />

NF250-RGW/UGW, NF125-RGW/UGW<br />

NF250-SGW/HGW, NF160-SGW/HGW, NF125-SGW/HGW<br />

NF250-RGW/UGW, NF125-RGW/UGW<br />

NF250-SGW/HGW, NF160-SGW/HGW, NF125-SGW/HGW<br />

NF250-UGW, NF125-UGW<br />

Notes: ✽ You can use the plug-in terminal unit (PM) when the wiring of terminal units is required in advance, and the delivery of both the main body and the<br />

components at the same time, which is normal, is not allowed. Furthermore specify the nonuse of plug-in terminal (PM-N) for the connection of circuit breaker.<br />

✽ <br />

<br />

2P<br />

3P<br />

4P<br />

2P<br />

2P<br />

3P<br />

4P<br />

2P<br />

3P<br />

4P<br />

2P<br />

3P<br />

4P<br />

Solderless terminal (SL) Rear studs (B-ST) Plug-in (PM) ✽<br />

ST-05SW2<br />

PM-05SW2<br />

<br />

ST-05SW3<br />

PM-05SW3<br />

ST-05SW4<br />

PM-05SW4<br />

SL-1SW4<br />

SL-1SW3<br />

SL-1SW4<br />

SL-1SW4<br />

SL-2UW3<br />

SL-1SW4<br />

SL-2GSW4<br />

SL-2GSW3<br />

SL-2GSW4<br />

ST-1SW2<br />

ST-1HW2<br />

ST-1SW3<br />

ST-1SW4<br />

ST-2SW2<br />

ST-2UW3<br />

ST-2SW4<br />

ST-2GSW2<br />

ST-2GSW3<br />

ST2GSW4<br />

PM-1SW2<br />

PM-1HW2<br />

PM-1UW2<br />

PM-1SW3<br />

PM-1UW3<br />

PM-1SW4<br />

<br />

PM-2SW2<br />

PM-2SW3<br />

PM-2SW4<br />

PM-2GSWIP2 ✽ <br />

PM-2SW2<br />

PM-2GSWIP3 ✽ <br />

PM-2SW3<br />

PM-2GSWIP4 ✽ <br />

<br />

3. Connection of Line and Load<br />

The standard wiring of line and load on the circuit breaker is (a) normal connection shown on<br />

the right. Avoid the wiring shown in (b) reverse connection, which may lead to the decrease in<br />

breaking performance. However, the reverse connection is allowed for the following models<br />

(except NF and NV models with MDU).<br />

Line<br />

Load<br />

NF-C series, NF-S series, NF-H series, NF-U series,<br />

MB series, CS series of NV400–800A<br />

Reverse connection is allowed for the standard models.<br />

Load<br />

Normal connection (a)<br />

Line<br />

Reserve connection (b)<br />

Normal and reverse connection methods<br />

22


5. Accessories<br />

Internal Accessories<br />

1. Accessories<br />

Table 5-1: Accessories<br />

Internal accessories Function Applicable models Cassette-type of accessories<br />

AL Alarm switch A switch that electrically indicates the trip status of the circuit breaker. NF-CSHU,<br />

●<br />

Auxiliary switch A switch that electrically indicates the ON-OFF status of the circuit breaker.<br />

NV-CSHU<br />

and MB series<br />

●<br />

AX<br />

SHT<br />

UVT<br />

EAL<br />

Shunt trip<br />

A<br />

Undervoltage trip<br />

A<br />

Earth-leakage alarm switch<br />

A<br />

This<br />

Test button module<br />

TBM<br />

MG<br />

Insulation switch<br />

The<br />

device that electrically trips the circuit breaker from a remote distance.<br />

Permissible working voltages are 70 to 110% of the AC rated voltage or<br />

70 to 125% of the DC rated voltage.<br />

device that automatically trips the circuit breaker if the voltage is lowered.<br />

Working voltages are 70 to 35% of the UVT rated voltage. When the voltage<br />

recovers to 85% or higher, you can reset the device and put into operation.<br />

switch that electrically indicates the trip status of the earth leakage<br />

circuit breaker caused by a ground fault. This switch is available only for<br />

models with the vertical lead-wire terminal unit (SLT).<br />

module allows you a remote testing by applying a voltage.<br />

An external sequence common to SHT can be used. (The standard<br />

configuration requires the vertical lead-wire terminal unit (SLT).)<br />

incorporation of this switch enables the measurement of insulation resistance<br />

between the terminals of the load with the circuit breaker being turned OFF.<br />

NF-CSHU<br />

and MB series<br />

NF-CSHU, <br />

NV-CSHU<br />

and MB series<br />

NV-CSU<br />

NV-CSU<br />

NV-CSU<br />

Note: Models NV250-SEW/HEW are excluded. Remark: (1) Accessory terminals are marked by both IEC-based terminal symbols<br />

and conventional symbols, like 98/ALa.<br />

●<br />

●<br />

<br />

<br />

<br />

<br />

2. Switch Operation and Rating<br />

Table 5-2: AL Switch Operation<br />

Circuit breaker status<br />

OFFON<br />

<br />

Table 5-3: AX Switch Operation<br />

Circuit breaker status<br />

OFF<br />

ON<br />

Table 5-4: EAL Switch Operation<br />

Circuit breaker status<br />

Over current trip,<br />

short circuit trip,<br />

ON, OFF<br />

Ground fault trip<br />

AL switch contact<br />

AX switch contact<br />

EAL switch contact<br />

98ALa (open)<br />

96ALb (closed)<br />

95ALc<br />

98ALa (closed)<br />

96ALb (open)<br />

95ALc<br />

14AXa (open)<br />

12AXb (closed)<br />

11AXc<br />

14AXa (closed)<br />

12AXb (open)<br />

11AXc<br />

EALa (open)<br />

EALc<br />

EALa (closed)<br />

EALc<br />

Table 5-6: AL and AX Switch Rating<br />

Switch<br />

type<br />

S<br />

Voltage<br />

(V)<br />

AC<br />

Resistive<br />

load<br />

Current (A)<br />

Please contact us for applications in the field of smaller current values.<br />

Table 5-7: EAL Switch Rating<br />

AC<br />

Voltage<br />

(V)<br />

Resistive<br />

load<br />

Inductive<br />

load<br />

A control power supply (compatible to 100 and<br />

200V AC) is required; see the diagram on the<br />

right showing its wiring. (The permissible range<br />

of voltage of the control power supply is 80 to<br />

242V AC, and the power requirement is 10VA.)<br />

Inductive<br />

load<br />

Voltage<br />

(V)<br />

DC<br />

Resistive<br />

load<br />

Current (A)<br />

Inductive<br />

load<br />

460 250 0.2 0.2<br />

250 3 2 125 0.4 0.4<br />

125 5 3 30 4 3<br />

Current A<br />

200 3 2<br />

100 3 2<br />

Vertical lead-wire<br />

terminal unit<br />

EALa<br />

Indicator lamp<br />

(example)<br />

P2 Control power<br />

supply<br />

P1(EALc)<br />

Table 5-5: MG Switch Operation<br />

Circuit breaker status<br />

MG switch status<br />

OFF<br />

MG<br />

ON<br />

MG<br />

23


3. Combinations of Accessories<br />

<br />

AL<br />

AX SHTUVT<br />

<br />

<br />

MG EAL TBM <br />

<br />

Table 5-8Combinations of Accessories<br />

<br />

<strong>Series</strong> NF-CSHU, MB NV-CSHU<br />

Number of poles<br />

Accessories<br />

Type name<br />

NF32-SW<br />

NF63-CW/SW/HW<br />

NF125-CW/SW<br />

NF32-SW(3P)<br />

NF63-CW/SW/HW(3P)<br />

NF125-CW(3P), NF125-SW(3P, 4P)<br />

NF125-HW, NF125-SGW/HGW<br />

NF125-RGW/UGW<br />

NF160-SW/SGW/HW/HGW<br />

NF250-CW/SW/HW<br />

NF250-SGW/HGW<br />

NF250-RGW/UGW<br />

MB30-SW, MB50-CW/SW<br />

MB100-SW, MB225-SW<br />

NV32-SW<br />

NV63-CW/SW/HW<br />

NV125-CW/SW/HW<br />

NV250-CW/SW/HW<br />

NV250-SEW/HEW<br />

NV125-RW, NV250-RW<br />

2-pole 2-pole, 3-pole, 4-pole 2-pole, 3-pole, 4-pole<br />

AL<br />

<br />

<br />

AX<br />

<br />

<br />

AL+AX<br />

<br />

<br />

<br />

<br />

(Note 1)<br />

(Note 1)<br />

SHT or UVT<br />

AL+SHT or UVT<br />

AX+SHT or UVT<br />

AL+AX+SHT or UVT<br />

(Note 2) (Note 2)<br />

(Note 2)<br />

(Note 3)<br />

(Note 4)<br />

(Note 6)<br />

(Note 2)<br />

(Note 2)<br />

(Note 1)<br />

(Note 2)<br />

MG<br />

AL+MG<br />

AX+MG<br />

EAL<br />

(Note 5)<br />

TBM<br />

Notes: (1) Second AX can substitute the AL on the left-pole.<br />

(2) Models with UVT require a UVT voltage module to be installed on the lead-wire terminal unit. (No such voltage<br />

module is required for SHT.) Part of UVT accessories is not of cassette type. (Details will be available upon request.)<br />

(3) UVTs for left-pole installation can be produced, if specified, for frame current values of 32, 63 and 125A<br />

(excluding SGW/HGW/RGW/UGW).<br />

(4) SHT cannot be installed.<br />

(5) EALs are available only for models with the vertical lead-wire terminal unit (SLT). Specify a control power supply<br />

of either 100 or 200 V AC.<br />

(6) Models NV250-SEW/HEW are not allowed to install the UVT device.<br />

Remarks: (1) Circled numbers indicate the order of installation.<br />

(2) Accessories of EAL, and TBM can be installed independent of installations of AL, AX, and MG.<br />

(Two units among EAL, and TBM cannot be installed at the same time.)<br />

24


5. Accessories<br />

Internal Accessories<br />

4. Shunt Trip (SHT)<br />

Table 5-9: Standard Coil Rating<br />

<strong>Series</strong><br />

Cut-off<br />

switch<br />

Voltage (V)<br />

Input power requirement (VA) (Note 1)<br />

AC<br />

DC<br />

Operating time (ms) (Note 2)<br />

NF-CSHU<br />

MB<br />

32(30)63A<br />

125A<br />

(NF125-SGW/HGW/RGW/UGWare excluded)<br />

160250A<br />

NF125-SGW/HGW/RGW/UGW<br />

<br />

AC100-240<br />

380-550<br />

(Compatible to 50 and 60Hz. )<br />

DC100-125<br />

120<br />

50<br />

60<br />

15 or less<br />

Notes: (1) Secure a sufficient input power so that the voltage will not drop below the permissible lower working voltage (70% of the lowest rated voltage).<br />

(2) The operating time denotes the time from when the rated voltage is applied to SHT until when the main contact of the breaker starts to open.<br />

5. Undervoltage Trip (UVT)<br />

Table 5-10: Standard Coil Rating<br />

<strong>Series</strong><br />

All models<br />

Notes: (1) A desired voltage can be selected by changing the terminal wiring.<br />

(2) The operating time denotes the time from when no voltage is<br />

applied to UVT until when the main contact of the breaker starts to<br />

open.<br />

(3) Time-delayed types can be produced. Details will be available upon<br />

request.<br />

● UVT Voltage Module<br />

The UVT voltage module is<br />

normally installed on the<br />

vertical lead-wire terminal<br />

unit (SLT). (A separatemount<br />

type can be produced<br />

upon request.)<br />

UVT Voltage Module Wiring Diagram<br />

(Lead-Wire Connection)<br />

6. Test Button Module (TBM) 7. Lead-wire Specifications<br />

● The effect of pressing the test button on the breaker main body is<br />

produced while the input control voltage is applied. (Apply the voltage<br />

for more than two seconds for the breaker main body of time-delayed<br />

NV models.)<br />

● The model with the vertical lead-wire terminal unit (SLT) is standard.<br />

Table 5-11<br />

<strong>Series</strong><br />

Input rated<br />

control<br />

voltage (V)<br />

Input control<br />

power (VA)<br />

Voltage (V)<br />

(Note 1)<br />

AC100-110/120-130 selectable<br />

200-220/230-250 selectable<br />

380-415/440-480 selectable<br />

(Compatible to 50 and 60Hz. )<br />

DC100/110 selectable<br />

NV-CSHU<br />

Compatible to<br />

AC100-240/<br />

DC100-240<br />

(DC24)(Note 1)<br />

1VA or less<br />

Note: (1) The specifications of 100-240V<br />

AC/100-240V DC are standard<br />

unless otherwise specified. The<br />

specifications of 24 V DC are<br />

available if requested.<br />

Input<br />

power<br />

(VA)<br />

Operating<br />

time (ms)<br />

(2) (3)<br />

5 30 or less<br />

18<br />

7<br />

12.5<br />

10.5<br />

(10.5)<br />

TBM2<br />

TBM1<br />

92 (Terminal<br />

cover)<br />

Table 5-12<br />

Type Size Length Marking Ring-mark example<br />

Heatresistant<br />

wire<br />

0.5mm 2 (Note 1)<br />

450mm<br />

Circuit<br />

breaker<br />

D3/P3<br />

D2/P2<br />

A ring-mark marked<br />

by the terminal symbol<br />

is attached to each<br />

lead-wire.<br />

98/ALa 96/ALb 95/ALc<br />

C1/S1 C2/S2<br />

Note: (1) The length is 400 mm for the model of four-pole, right-pole installation.<br />

● Lead wires are normally extended laterally.<br />

● Grooves are provided standardly on the side face of the breaker,<br />

allowing the extension of the lead wires along them. (1)<br />

J1UC1<br />

J2UC2<br />

Note: (1) The models of NF125-SGW/HGW/RGW/UGW, NF160-SGW/HGW,<br />

NF250-SGW/HGW/RGW/UGW are excluded.<br />

UVT voltage module<br />

D1/P1<br />

J1/UC1<br />

J2/UC2<br />

8. Internal Terminal Type (INT)<br />

● This unit is an internal accessory that is provided with terminal screws for lead-wire connection.<br />

Remark: (1) Available for the models of NF125-SGW/HGW/RGW/UGW,<br />

NF160-SGW/HGW, NF250-SGW/HGW/RGW/UGW.<br />

25


9. Vertical Lead-wire Terminal Block (SLT)<br />

● The circuit beaker can be mounted, being closely fitted to the unit.<br />

● Terminal screws are arranged in a zigzag pattern, and screws can be tightened further after wiring.<br />

● A terminal cover is provided standardly.<br />

● This unit supports the models of front connection, rear connection, and plug-in type (excluding PLT).<br />

<br />

<br />

10. Cassette-type Accessories<br />

● Cassette-type of accessories can be mounted onto and demounted from the circuit breaker by users themselves.<br />

Table 5-13: Cassette Types of Accessories<br />

Applicable models<br />

NF32-SWNF63-CW/SW/HW<br />

NV32-SWNV63-CW/SW/HW<br />

MB30-SWMB50-SW<br />

NF125-CW/SW/HW<br />

NV125-CW/SW/HWRW<br />

MB100-SW<br />

NF250-CW/SW/HW<br />

NF160-SW/HW<br />

NV250-CW/SW/HW/RW/SEW/HEW<br />

NF250-SGW/HGW/RGW/UGW<br />

NF160-SGW/HGW<br />

NF125-SGW/HGW/RGW/UGW<br />

Model designation code<br />

Kind of<br />

accessories<br />

SHT<br />

A048 : 24-48VAC<br />

A240 : 100-240VAC<br />

A550 : 380-550VAC<br />

D012 : 12VDC<br />

D036 : 24-36VDC<br />

D048 : 36-48VDC<br />

D125 : 100-125VDC<br />

D250 : 220-250VDC<br />

<br />

<br />

Group name<br />

05<br />

1<br />

2<br />

2G<br />

AL<br />

AL-05SWL(S)<br />

AL-05SWR(S)<br />

AL-1SW<br />

AL-1SWLS<br />

AL-1SWRS<br />

AL-2SWL(S)<br />

AL-2SWR(S)<br />

AL-2GSWL(S)<br />

AL-2GSWR(S)<br />

AL-2GSWN<br />

Group name<br />

SHT A130 1 SW R S<br />

Voltage<br />

UVT<br />

A048 : 24-48VAC selectable<br />

A130 : 100-110/120-130VAC selectable<br />

A250 : 200-220/230-250VAC selectable<br />

A480 : 380-415/440-480VAC selectable<br />

A600 : 500-550/600VAC selectable<br />

D110 : 100/110VDC selectable<br />

AX ALAX SHT (1)<br />

AX-05SWL(S)<br />

AX-05SWR(S)<br />

AX-1SW<br />

AX-1SWLS<br />

AX-1SWRS<br />

AX-2SWL(S)<br />

AX-2SWR(S)<br />

AX-2GSWL(S)<br />

AX-2GSWR(S)<br />

AX-2GSWN<br />

ALAX-05SWL(S)<br />

ALAX-05SWR(S)<br />

ALAX-1SW<br />

ALAX-1SWLS<br />

ALAX-1SWRS<br />

ALAX-2SWL(S)<br />

ALAX-2SWR(S)<br />

ALAX-2GSWL(S)<br />

ALAX-2GSWR(S)<br />

ALAX-2GSWN<br />

“S” denotes that the vertical<br />

lead-wire terminal block (SLT) is added<br />

(if not specified, lead wires are extended).<br />

“N” denotes “internal terminal.”<br />

Installation position<br />

R: right-pole installation<br />

L: left-pole installation<br />

Blank: either pole installation<br />

Kind of accessories<br />

SHTA240-05SWR(S)<br />

SHTA550-05SWR(S)<br />

SHTD125-05SWR(S)<br />

SHTA240-1SWR(S)<br />

SHTA550-1SWR(S)<br />

SHTD125-1SWR(S)<br />

SHTA240-2SWR(S)<br />

SHTA550-2SWR(S)<br />

SHTD125-2SWR(S)<br />

SHTA240-2GSWR(S)<br />

SHTA550-2GSWR(S)<br />

SHTD125-2GSWR(S)<br />

SHTA240-2GSWRN<br />

SHTA550-2GSWRN<br />

SHTD125-2GSWRN<br />

UVTN or UVTS) (2)<br />

UVTNA130-05SWR(S)<br />

UVTNA130-05SWL(S)<br />

UVTNA250-05SWR(S)<br />

UVTNA250-05SWL(S)<br />

UVTNA130-1SW<br />

UVTNA130-1SWRS<br />

UVTNA130-1SWLS<br />

UVTNA250-1SW<br />

UVTNA250-1SWRS<br />

UVTNA250-1SWLS<br />

UVTNA480-1SW<br />

UVTNA480-1SWRS<br />

UVTNA480-1SWLS<br />

UVTND110-1SW<br />

UVTNA130-2SWR(S)<br />

UVTNA130-2SWL(S)<br />

UVTNA250-2SWR(S)<br />

UVTNA250-2SWL(S)<br />

UVTSA130-2GSWR(S)<br />

UVTSA250-2GSWR(S)<br />

UVTSA480-2GSWR(S)<br />

UVTSD110-2GSWR(S)<br />

UVTNA480-05SWR(S)<br />

UVTNA480-05SWL(S)<br />

UVTND110-05SWR(S)<br />

UVTND110-05SWL(S)<br />

UVTND110-1SWRS<br />

UVTND110-1SWLS<br />

UVTSA130-1SW<br />

UVTSA130-1SWRS<br />

UVTSA250-1SW<br />

UVTSA250-1SWRS<br />

UVTSA480-1SW<br />

UVTSA480-1SWRS<br />

UVTSD110-1SW<br />

UVTSD110-1SWRS<br />

UVTNA480-2SWR(S)<br />

UVTNA480-2SWL(S)<br />

UVTND110-2SWR(S)<br />

UVTND110-2SWL(S)<br />

UVTSA130-2GSWRN<br />

UVTSA250-2GSWRN<br />

UVTSA480-2GSWRN<br />

UVTSD110-2GSWRN<br />

Notes: (1) NV models are excluded.<br />

(2) UVTN<br />

Non-Synchronous closing<br />

UVTS<br />

Synchronous closing<br />

With the UVTS model, the breaker can be reset even if<br />

the voltage is not applied.<br />

NF250-SEW/HEW models cannot be produced.<br />

Remarks: (1) Refer to Combinations of Accessories for<br />

details of combinations and poles.<br />

(2) A cassette type of AL cannot be installed on circuit<br />

breakers with MG switch.<br />

11. Pre-alarm Modules (PAL)<br />

● The PAL can be installed on the right side face of electronic<br />

circuit breaker.<br />

Table 5-14<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

Pre-alarm<br />

SSR output<br />

Pre-alarm module<br />

(mechanical contact output) (Note 2)<br />

Option Option (Note 1)<br />

NV250-SEW/HEW ● (Note 3)<br />

Option (Note 1)<br />

Notes: (1) A control power supply (compatible to 100–200V AC) is required.<br />

(2) An additional accessory cannot be installed on the right pole in this case.<br />

(3) LED indicate only<br />

●Pre-alarm Characteristics<br />

Working Duration<br />

4h<br />

2h<br />

Pre-alarm<br />

1h<br />

Operating<br />

30min<br />

Characteristics<br />

20min<br />

14min<br />

10min<br />

LTD working duration TL<br />

6min<br />

60-80-100s (at 200%)<br />

4min<br />

2min<br />

100s<br />

1min<br />

50s<br />

Pre-alarm<br />

30s pick-up current<br />

20s Inx(0.70-0.75-0.8-<br />

0.85-0.9-0.95-1.0)<br />

10s<br />

Pre-alarm working duration<br />

5s<br />

Tp= TL (at200%)<br />

2<br />

2s<br />

60 70 100 125 200 300 400 500600700 1000<br />

Current<br />

(percentage against rated current or specified rated current)<br />

The self-hold type is standard, but an<br />

automatic-reset type can be produced<br />

upon request.<br />

●Pre-alarm Module<br />

18<br />

92<br />

PALa<br />

P2 <br />

P1 <br />

(PALc)<br />

26


5. Accessories<br />

External Accessories<br />

O F<br />

F<br />

ON<br />

REL<br />

E<br />

1. F-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● Outside Dimension Diagram<br />

Center of Hinge and Circuit Breaker<br />

Left hinge<br />

Right hinge<br />

● This handle in conjunction with the breaker<br />

enables the isolation function effective.<br />

● The standard model is equipped with a safety<br />

device that prevents the circuit breaker from<br />

being turned on if the door is open. (If not<br />

desired, please specify so.)<br />

● The handle can be locked at either ON or<br />

OFF position. (Three padlocks (40mm) can<br />

be installed. OFF-position lock only<br />

specifications are also acceptable.)<br />

● Degrees of protection (IEC60529) IP3X<br />

(IP5X with dustproof packing)<br />

Remark: (1) Trip action can be displayed when the circuit<br />

breaker trips even if ON-position lock is selected<br />

(only in the case of a single padlock (35 mm)).<br />

RESET<br />

OPEN<br />

● Drilling Dimension Diagram<br />

Center of the circuit<br />

breaker operating handle<br />

4ø12<br />

CL<br />

Circuit<br />

breaker<br />

CL<br />

TRIPPED<br />

104<br />

78<br />

AS E<br />

ø90<br />

104<br />

78<br />

51<br />

Plate<br />

thickness 1.2–3.2<br />

Circuit breaker<br />

CL<br />

A2<br />

(a)<br />

(b)<br />

CL<br />

B<br />

Center of<br />

the circuit<br />

breaker<br />

and the<br />

operating<br />

handle<br />

(b)<br />

(a)<br />

C<br />

D<br />

H X1 H X2<br />

0<br />

or higher<br />

Left hinge<br />

(5H+100)<br />

or higher<br />

Front plate<br />

H<br />

X1<br />

Less than<br />

10<br />

10<br />

or higher<br />

Operating handle<br />

circuit<br />

breaker<br />

170<br />

or higher<br />

(5H+120)<br />

or higher<br />

The above illustration shows a view of<br />

the hinges and the circuit breaker when<br />

viewed from the direction of the load.<br />

X2<br />

H<br />

Right hinge<br />

Table 5-15: Summary of Dimensions<br />

Type name<br />

Applicable models<br />

<br />

<br />

A (1) B C D<br />

F05SW2P NF32-SW, NF63-CW/SW/HW 2P<br />

<br />

F05SW<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-SW/HW, MB30-SW, MB50-CW/SW<br />

3P, 4P<br />

111<br />

25<br />

NV63-CW/SW<br />

2P, 3P 105<br />

F1SW2P NF125-CW/SW/HW 2P <br />

F1SW NF125-CW/SW/HW, NV125-CW/SW/HW, MB100-SW 3P, 4P 30<br />

111<br />

F2SW NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW, NV250-SEW/HEW, MB225-SW 2P, 3P, 4P 107 35 126<br />

F2GSW NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW 3P, 4P 125 35 126<br />

2. S-type Handle<br />

● Appearance (Color N1.5)<br />

● The handle can be locked at either ON or<br />

OFF position. (Three padlocks (40mm) can<br />

be installed. Off-position lock only<br />

specifications are also acceptable.)<br />

● Digrees of protection (IEC60529) IP5X<br />

Remark: (1) Trip action can be displayed when the circuit<br />

breaker trips even if ON-position lock is selected<br />

(only in the case of a single padlock (35 mm)).<br />

Table 5-16: Summary of Dimensions<br />

Type name<br />

● Outside Dimension Diagram<br />

Operating plate<br />

Max. 95<br />

Max. 115<br />

34 40<br />

Applicable models<br />

Front plate<br />

Operating plate<br />

● Front Plate Drilling Dimension Diagram<br />

<br />

A (4) B (4) C (4)<br />

S05SW NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW, MB30-SW, MB50-CW/SW<br />

87 102 104.5<br />

S1SW NF125-CW/SW/HW, NV125-CW/SW/HW, MB100-SW, NV125-RW (Note 5)<br />

S2SW NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW, NV250-SEW/HEW, MB225-SW, NV250-RW (Note 5) 95 110 112.5<br />

S2GSW NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW 113 128 130.5<br />

Face plate<br />

Notes: (1) The clasps are not supplied standardly, and should be prepared by users. Details on dimensions and others will be<br />

available upon request.<br />

(2) When the optional clasp is used.<br />

(3) The tolerance from the center of ø62 is shown.<br />

(4) The dimensions of the front-face type are shown. Some of the back-face and plug-in types have a different reference<br />

plane for mounting the circuit breaker.<br />

(5) The front plate drilling dimensions for the U series differ from those shown above. Please consult us for their details.<br />

OFF<br />

TRIP<br />

45<br />

ON<br />

110<br />

114<br />

80<br />

ø62<br />

<br />

41.5±4<br />

Clasp<br />

(Note 1)<br />

Center of the circuit breaker<br />

operating handle<br />

17<br />

Clasp<br />

(Note 1)<br />

(Note 2)<br />

Clasp<br />

(option)<br />

70<br />

(Note 3)<br />

43.5±4<br />

Either<br />

M4×0.7<br />

screw or ø5<br />

47<br />

4-ø4.5<br />

9<br />

70<br />

Center of the circuit<br />

breaker<br />

<br />

<br />

<br />

ø12<br />

Front plate deviation of 4mm or less<br />

100 or more (210 or more<br />

when the hinge is on the left)<br />

A±2<br />

B±2<br />

(Note 2) C±2<br />

Hinge<br />

<br />

<br />

(a) Circuit<br />

breaker<br />

mounting screws<br />

(2pcs)<br />

(b) Handle<br />

mounting screws<br />

(2pcs)<br />

Note: (1) Dimensions of both front connection and rear connection are shown. The plug-in type has a different reference plane for mounting the circuit breaker.<br />

Remarks: (1) The test button becomes difficult to press when an operating handle is installed on an NV model. Then, use models with either TBM instead.<br />

(2) Dustproof packings are separately available.<br />

(3) You may consult us for details of the F-type operating handle for the U series.<br />

(4) The standard type is equipped with a door-lock mechanism that allows the door to be opened only when OFF operation (see below *) is carried out. (*) We can supply upon<br />

request another door-lock mechanism that allows the door to be opened only when reset operation is carried out, which, however, is not isolation-compatible.<br />

Front plate thickness1.2–3.2<br />

Reference plane for mounting<br />

the circuit breaker<br />

Remark: (1) These are not suitable for isolation.<br />

27


3. V-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● Outside Dimension Diagram<br />

A<br />

Front base<br />

Front plate<br />

Center of Hinge and<br />

Circuit Breaker<br />

Handle<br />

Front plate<br />

TR<br />

I P<br />

PED<br />

O<br />

N<br />

B<br />

90<br />

H<br />

H<br />

OFF<br />

● This handle in conjunction with the breaker main<br />

enables the isolation function effective.<br />

● The safety standards of EN Standards<br />

(EN60204-1) are satisfied.<br />

● Degrees of protection (IEC60529) IP65 is<br />

satisfied standardly.<br />

● OFF-position lock only is available for up to three<br />

commercial padlocks (ø8).<br />

● A door-lock mechanism allows the door to be<br />

opened at OFF-position only.<br />

RESET<br />

16<br />

90<br />

Plate<br />

thickness<br />

1.2–3.2<br />

● Mounting-hole Drilling Dimension Diagram<br />

Center of the<br />

circuit breaker<br />

operating handle<br />

H<br />

C L<br />

54<br />

C<br />

<br />

Maximum F<br />

Circuit breaker Center of the<br />

operating handle<br />

Center of the circuit<br />

breaker operating handle<br />

D<br />

Left<br />

Hinge<br />

H<br />

X<br />

0 or higher (5H+100)<br />

The above illustration shows a view<br />

of the hinges and the circuit breaker<br />

when viewed from the direction of<br />

the load.<br />

● Front Plate Drilling<br />

Dimension Diagram<br />

C L C L<br />

Center of the circuit breaker<br />

C L C L<br />

operating handle<br />

C L ø<br />

H<br />

Center of the<br />

circuit breaker<br />

(Note 1)<br />

X<br />

Circuit<br />

breaker<br />

X<br />

Right<br />

Hinge<br />

Circuit<br />

breaker<br />

C L<br />

ø54<br />

54<br />

G<br />

3-pole<br />

Either M4×0.7<br />

screw or ø5<br />

J<br />

G G<br />

4-pole<br />

Either M4×0.7<br />

screw or ø5<br />

54<br />

Note 1: The drilling at this position is not required for the models of both V2GSW and V2GSWF.<br />

Table 5-17: Summary of Dimensions<br />

Type name<br />

Applicable models<br />

(Note 2) NF32-SW, NF63-CW/SW/HW, NV32-SW<br />

(Note 3) NV63-CW/SW/HW, MB30-SW<br />

V05SWF MB50-CW/SW<br />

<br />

<br />

3P<br />

4P<br />

<br />

A B C D E F G H J<br />

<br />

75 130 44 61 125 25 111<br />

12.5<br />

V1SW<br />

(Note 2)<br />

V1SWF<br />

NF125-CW/SW/HW, NV125-CW/SW/HW<br />

MB100-SW<br />

3P<br />

4P<br />

90 130 44 61<br />

154 518<br />

125 <br />

30 111<br />

<br />

15<br />

V2SW<br />

(Note 2)<br />

V2SWF<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW<br />

NV250-SEW/HEW, MB225-SW<br />

2P, 3P<br />

4P<br />

105 165 46 61<br />

154 518<br />

125 <br />

35 126<br />

<br />

17.5<br />

V2GSW<br />

(Note 2)<br />

V2GSWF<br />

3P<br />

NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW 105 165 46 79<br />

4P<br />

172 536<br />

143 <br />

35 126<br />

<br />

17.5<br />

Notes: (1) This hole is not required for two and three poles.<br />

(2) The last letter of “F” of the type designations of V-type operating handles denotes a fixed type. Attach the letters of “4P”<br />

to the end of designation for four-pole models of circuit breaker main body.<br />

(3) Adjustable types can be produced upon request. Please contact us for details.<br />

Remark: (1) You may contact us for details of the V-type operating handle for the U series.<br />

✽ <br />

28


5. Accessories<br />

External Accessories<br />

4. R-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● Outside Dimension Diagram<br />

A<br />

Handle<br />

B<br />

88<br />

16<br />

88<br />

E<br />

D<br />

C<br />

● This handle in conjunction with the breaker main<br />

enables the isolation function effective.<br />

● OFF-position lock only is available for up to three<br />

commercial padlocks (ø8).<br />

● Equipped with cylinder key (option) prevent<br />

deliberate operation.<br />

● Mounting-hole Drilling Dimension Diagram<br />

Center of the<br />

circuit breaker<br />

operating handle<br />

G<br />

C L<br />

Circuit breaker Center of the<br />

operating handle<br />

Center of the circuit<br />

breaker operating handle<br />

Center of the<br />

circuit breaker<br />

C L C L<br />

C L C L<br />

(Note 1)<br />

G<br />

Center of the circuit<br />

breaker operating handle<br />

Center of the<br />

circuit breaker<br />

G<br />

C L<br />

H<br />

Table 5-18: Summary of Dimensions<br />

Type name<br />

Applicable models<br />

<br />

<br />

<br />

A B C D E F G H J<br />

R1SW<br />

NF125-CW, NF-125-SW, NF125-HW<br />

NV125-CW, NV125-SW, NF125-HW<br />

3P 90<br />

4P<br />

120<br />

130<br />

61 105 142 111 —<br />

—<br />

15<br />

R1UW NV125-RW<br />

3P 90<br />

191<br />

61<br />

105<br />

142<br />

30<br />

172<br />

30.5<br />

—<br />

R2SW<br />

NF160-SW, NF160-HW, NF250-CW, NF250-SW, NF250-HW<br />

NV250-CW, NV250-SW, NF250-HW, NV250-SEW<br />

NV250-HEW<br />

2P, 3P<br />

4P<br />

105<br />

140<br />

165<br />

61<br />

107<br />

144<br />

35<br />

126<br />

C L<br />

C L<br />

—<br />

F<br />

Either M4×0.7<br />

screw or ø5<br />

2, 3-pole 4-pole<br />

F<br />

J<br />

F<br />

Either M4×0.7<br />

screw or ø5<br />

Center of the<br />

operating handle<br />

Note 1: The drilling at this position is not required for the models of R2GSW.<br />

F<br />

Either M4×0.7<br />

screw or ø5<br />

—<br />

17.5<br />

R2UW<br />

NV250-RW<br />

3P<br />

105<br />

240<br />

61<br />

107<br />

144<br />

35<br />

201<br />

37.5<br />

—<br />

R2GSW<br />

NF125-SGW, NF125-HGW, NF160-SGW, NF160-HGW,<br />

NF250-SGW, NF250-HGW<br />

2P, 3P<br />

4P<br />

105<br />

140<br />

165<br />

79<br />

125<br />

162<br />

35<br />

126<br />

—<br />

—<br />

17.5<br />

R2GUW<br />

NF125-RGW, NF125-UGW, NF250-RGW, NF250-UGW<br />

3P<br />

105<br />

240<br />

79<br />

125<br />

162<br />

35<br />

201<br />

37.5<br />

—<br />

✽ <br />

5. Circuit Breaker Box and Box-type Circuit Breaker<br />

Table 5-19: Types and Specifications<br />

Remark: (1) You may contact us for details of the V-type<br />

operating handle for the U series.<br />

Dustproof (S) Dustproof (I) Waterproof (W)<br />

Appearance<br />

Degrees of protection (IEC60529)<br />

<br />

IP4X<br />

IP54<br />

Number of poles 2P3P 2P3P 3P<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW<br />

NV63-CW/SW/HW, MB30-SW, MB50-CW/SW<br />

NF125-CW/SW, NV125-CW/SW, MB100-SW<br />

NFS-05SW (Note 1)<br />

NFI-05SW NFW-05SW<br />

NFW-1SW<br />

NFS-1SW (Note 1)<br />

NFI-1SW<br />

NF125-HW, NV125-HW<br />

NFW-1HW<br />

NF160-SW, NF250-CW/SW, NV250-CW/SW, NV250-SEW, MB225-SW<br />

NFS-2SW<br />

NFI-2SW<br />

NFW-2SW<br />

NF160-HW, NF250-HW, NV250-HW, NV250-HEW<br />

<br />

NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW NFI-2GSW NFW-2GSW<br />

Note: (1) Attach the letters of “2P” to the end of type designation when the circuit breaker of external two poles.<br />

Remarks: (1) Use your working current by 80% and under of rated current.<br />

(2) The dustproof type (I) is not suitable for isolation.<br />

29


6. Terminal Cover<br />

Table 5-20<br />

Large terminal cover<br />

(TC-L)<br />

Small terminal cover<br />

(TC-S)<br />

Transparent terminal<br />

cover (TTC)<br />

Rear terminal cover<br />

(BTC)<br />

Plug-in terminal cover<br />

(PTC)<br />

Breaker type<br />

A<br />

A<br />

A<br />

A<br />

A<br />

C<br />

C<br />

C<br />

C<br />

B<br />

B<br />

B<br />

B<br />

B<br />

C<br />

NF32-SW, NF63-CW/SW/HW<br />

2P<br />

(Note 1)<br />

TCL-05SW2W<br />

(5065.525)<br />

(Note 1)<br />

TCS-05SW2W<br />

(5065.55)<br />

(Note 1)<br />

TTC-05SW2<br />

(5065.525)<br />

BTC-05SW2W<br />

(5065.55)<br />

PTC-05SW2W<br />

(5065.56.5)<br />

NF32-SW, NF63-CW/SW/HW<br />

NV32-SW, NV63-CW/SW/HW, MB30-SW<br />

MB50-CW/SW<br />

3P<br />

(Note 2)<br />

TCL-05SW3W<br />

(7565.525)<br />

(Note 2)<br />

TCS-05SW3W<br />

(7565.55)<br />

(Note 2)<br />

TTC-05SW3<br />

(7565.525)<br />

BTC-05SW3W<br />

(7565.55)<br />

PTC-05SW3W<br />

(7565.56.5)<br />

NF125-CW/SW/HW<br />

2P IP20<br />

(Note 1)<br />

TCL-1SW2W<br />

(6065.540)<br />

(Note 1)<br />

TCS-1SW2W<br />

(6065.56.5)<br />

(Note 1)<br />

TTC-1SW2<br />

(6065.540)<br />

BTC-1SW2W<br />

(6065.56.5)<br />

PTC-1SW2W<br />

(6065.56.5)<br />

NF125-CW/SW/HW, NV125-CW/SW/HW,<br />

NV125-RW, MB100-SW<br />

3P<br />

(Note 2)<br />

TCL-1SW3W<br />

(9065.540)<br />

(Note 2)<br />

TCS-1SW3W<br />

(9065.56.5)<br />

(Note 2)<br />

TTC-1SW3<br />

(9065.540)<br />

BTC-1SW3W<br />

(9065.56.5)<br />

PTC-1SW3W<br />

(9065.56.5)<br />

NF160-SW/HW, NF250-CW/SW/HW,<br />

NV250-CW/SW/HW, NV250-SEW/HEW, NV250-RW<br />

MB225-SW<br />

2P<br />

3P<br />

(Note 2)<br />

TCL-2SW3W<br />

(10565.540)<br />

(Note 2)<br />

TCS-2SW3W<br />

(10565.56.5)<br />

(Note 2)<br />

TTC-2SW3<br />

(10565.540)<br />

BTC-2SW3W<br />

(10565.56.5)<br />

PTC-2SW3W<br />

(10565.56.5)<br />

NF125-SGW/HGW/RGW/UGW, NF160-SGW/HGW<br />

NF250-SGW/HGW/RGW/UGW<br />

2P<br />

3P<br />

IP40<br />

TCL-2GSW3W<br />

(1058440)<br />

TCS-2GSW3W<br />

(105846.5)<br />

TTC-2GSW3<br />

(1058440)<br />

BTC-2GSW3W<br />

(105846.5)<br />

PTC-2GSW3W<br />

(105846.5)<br />

Notes: (1) Attach the letter “F” to the end of model designation for models with F-type operating handle. (Those are F-type operating-handle dedicated models,<br />

and screws are used for fixing.)<br />

(2) An F-type operating handle can be installed standardly.<br />

Remarks: (1) Parenthesized numbers denote the outside dimensions (A×B×C in mm).<br />

(2) The terminal cover for a four-pole model can be produced upon request.<br />

7. Electrical Operation Device<br />

Table 5-21: Summary of Model Designations<br />

Rated operating<br />

voltage<br />

Applicable models<br />

(Note 1)<br />

NF125-CW(3P)<br />

NF125-SW(3P4P)<br />

NF125-HW<br />

NF160-SW/HW<br />

NF250-CW/SW/HW<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

NV125-CW/SW/HW NV250-CW/SW/HW NV250-SEW/HEW<br />

24V DC MDSD024-NF1SWE DSD024-NF2SWE MDSD024-NF2GSWE MDSD024-NV1SWE MDSD024-NV2SWE MDSD024-NVE2SWE<br />

Compatible to 100-240V<br />

AC/100-250V DC<br />

MDSAD240-NF1SWE MDSAD240-NF2SWE MDSAD240-NF2GSWE MDSAD240-NV1SWE MDSAD240-NV2SWE MDSAD240-NVE2SWE<br />

Table 5-22: Specifications<br />

Rated operating voltage<br />

(Allowable voltage range 85~110%)<br />

24V DC<br />

ON action 0.05–0.1<br />

Operating time (s) OFF action<br />

0.6 or less<br />

<br />

1.2 or less<br />

150<br />

Note: (1) Place an order of other models in conjunction with the circuit breaker.<br />

Remarks: (1) The standard terminal cover can be used.<br />

(2) Please contact us for details of the outside dimensions.<br />

Compatible to<br />

100-240V AC/100-250V DC<br />

Power supply module<br />

Electrical operation device<br />

Operating<br />

power supply<br />

Uc<br />

ON<br />

OFF<br />

(RESET)<br />

P1<br />

P2<br />

S1<br />

S2<br />

S4<br />

P.S<br />

power<br />

supply<br />

K1<br />

SW1<br />

K2<br />

K2<br />

K1<br />

SW2<br />

This refers to the status in which the circuit breaker is<br />

OFF and the electrical operation device is charged.<br />

M<br />

K3<br />

K3<br />

K3<br />

K2<br />

K1<br />

P.S<br />

SW1<br />

SW2<br />

M<br />

K1<br />

K2<br />

K3<br />

Switching power supply<br />

(100-240V AC/100-250V DC model only)<br />

Automatic/manual selection switch<br />

Charge/Discharge<br />

Sensing switch<br />

Motor<br />

Relay (OFF)<br />

Relay (Motor)<br />

Relay (Motor)<br />

30


5. Accessories<br />

External Accessories<br />

8<br />

8<br />

Dimensions<br />

Front connection<br />

● NF125-CW, NF125-SW, NF125-HW<br />

Insulation barrier<br />

(removable) OFF lock plate Center of the electrically operated<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply module<br />

M8 screw 24<br />

Circuit breaker<br />

Center of the electrically operated<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

P1P2 S1S2S4<br />

P1P2 S1S2S4<br />

111<br />

130 50<br />

86 45<br />

41<br />

78<br />

39<br />

60<br />

30<br />

86<br />

86<br />

Front plate<br />

90 90<br />

Display hole<br />

90<br />

(Charge/Discharge)<br />

120<br />

25<br />

158<br />

163<br />

61<br />

30 30<br />

M4x0.7 screw<br />

or ø5<br />

3-pole Drilling plant 4-pole<br />

106<br />

88<br />

Font-plate cut out<br />

40<br />

80<br />

ø8.5<br />

max. 19<br />

(Conductor thickness<br />

t=5 max.)<br />

Conductor drilling for<br />

direct connection<br />

Remarks:<br />

The two-pole circuit breakers of the<br />

models of both NF125-HW is the<br />

three-pole circuit breakers with their<br />

neutral conductor being removed.<br />

The three-pole type only is available<br />

for the model NF125-CW, and the<br />

3-pole and 4-pole types only are<br />

available for the model NF100-SW.<br />

● NF160-SW, NF160-HW, NF250-CW, NF250-SW, NF250-HW<br />

Insulation barrier OFF lock plate Center of the electrically operated<br />

(removable)<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

P1P2 S1S2S4<br />

P1P2 S1S2S4<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

70<br />

86<br />

35<br />

90<br />

86<br />

105<br />

90<br />

105<br />

140<br />

144<br />

165 100<br />

100<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

86 45<br />

37<br />

78<br />

35<br />

Front plate<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply<br />

M8 bolt (Hex-soket)<br />

module<br />

24<br />

61<br />

158<br />

163<br />

11.5<br />

Circuit breaker<br />

35 35<br />

3-pole Drilling plant 4-pole<br />

Center of the electrically operated<br />

126<br />

36<br />

80<br />

88<br />

M4x0.7 screw<br />

or ø5<br />

Font-plate cut out<br />

ø8.5<br />

10<br />

max. 23<br />

(Conductor thickness<br />

t=7 max.)<br />

Conductor drilling for<br />

direct connection<br />

Remarks:<br />

The 2-pole models are 3-pole models<br />

with the central pole removed.<br />

The 3-pole type only is available for<br />

the model NF250-CW, and the 3-pole<br />

and 4-pole types only are available for<br />

the model NF160-SW, NF160-HW,<br />

NF250-SW and NF250-HW.<br />

● NF125-SGW, NF125-HGW, NF160-SGW, NF160-HGW, NF250-SGW, NF250-HGW<br />

Insulation barrier OFF lock plate Center of the electrically operated<br />

(removable)<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

P1 P2 S1 S2 S4<br />

P1 P2 S1 S2 S4<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

70<br />

86<br />

35<br />

90<br />

86<br />

105<br />

90<br />

105<br />

140<br />

144<br />

50 165<br />

50<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

86 45<br />

37<br />

78<br />

35<br />

Front plate<br />

Display hole<br />

(Charge/Discharge)<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply<br />

M8 bolt (Hex-soket)<br />

module<br />

24<br />

79<br />

176<br />

181<br />

11.5<br />

Circuit breaker<br />

35 35<br />

3-pole Drilling plant 4-pole<br />

Center of the electrically operated<br />

126<br />

36<br />

80<br />

88<br />

M4x0.7 screw<br />

or ø5<br />

Font-plate cut out<br />

ø8.5<br />

10<br />

max. 24<br />

(Conductor thickness<br />

t=7 max.)<br />

Conductor drilling for<br />

direct connection<br />

● NV125-CW, NV125-SW, NV125-HW<br />

Insulation barrier<br />

(removable)<br />

OFF lock plate Center of the electrically operated<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply<br />

module<br />

M8 screw<br />

24<br />

Circuit breaker<br />

Center of the electrically operated<br />

P1 P2 S1 S2 S4<br />

P1 P2 S1 S2 S4<br />

111<br />

130 50<br />

45<br />

86<br />

78<br />

25<br />

106<br />

80<br />

ø8.5<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

60<br />

86<br />

90<br />

30<br />

86<br />

90<br />

90<br />

120<br />

41<br />

39<br />

Display hole Front plate<br />

(Charge/Discharge)<br />

Test button<br />

158<br />

163<br />

61<br />

30 30<br />

3-pole Drilling plant 4-pole<br />

M4x0.7 screw<br />

or ø5<br />

88<br />

Font-plate cut out<br />

40<br />

max.19<br />

(Conductor thickness<br />

t=5 max.)<br />

Conductor drilling for<br />

direct connection<br />

● NV250-SEW, NV250-HEW<br />

Insulation barrier OFF lock plate Center of the electrically operated<br />

(removable)<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

P1 P2 S1 S2 S4<br />

P1 P2 S1 S2 S4<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

70<br />

86<br />

35<br />

Test button<br />

90<br />

86<br />

105<br />

90<br />

105<br />

140<br />

144<br />

165 100<br />

86 45<br />

37<br />

78<br />

35<br />

100<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

Front plate<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply<br />

module<br />

158<br />

163<br />

11.5<br />

M8 bolt (Hex-soket)<br />

24<br />

61<br />

Circuit breaker<br />

35<br />

3-pole Drilling plant<br />

35<br />

4-pole<br />

Center of the electrically operated<br />

126<br />

36<br />

80<br />

88<br />

M4x0.7 screw<br />

or ø5<br />

Font-plate cut out<br />

ø8.5<br />

10<br />

max.23<br />

(Conductor thickness<br />

t=7 max.)<br />

Conductor drilling for<br />

direct connection<br />

Remarks:<br />

The 4-pole types only are available<br />

for the model NV250-SEW and<br />

NV250-HEW.<br />

31


8. Mechanical Interlocks (MI)<br />

Table 5-23<br />

Number<br />

Panel mouting<br />

Direct mount on<br />

Applicable models<br />

of poles Front connection, Rear connection, Plug-in Dimension A mm circuit breaker<br />

NF32-SW, NF63-CW/SW/HW<br />

2P<br />

47.5<br />

<br />

MI-05SW3<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW, MB30-SW, MB50-CW/SW 3P <br />

MI-05SWFB3<br />

NF63-SW/HW 4P MI-05SW4 <br />

NF125-CW/SW/HW<br />

2P<br />

45<br />

<br />

MI-05SW3<br />

3P<br />

MI-1SWFB3<br />

NF125-CW/SW/HW, NV125-CW/SW/HW, MB100-SW, NV125-RW<br />

4P<br />

MI-1SW4<br />

<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW, NV250-SEW/HEW,<br />

MB225-SW, NV250-RW<br />

NF160-SW/HW, NF250-SW/HW, NV250-SW/HW/SEW/HEW<br />

NF125-SGW/HGW/RGW/UGW, NF160-SGW/HGW, NF250-SGW/HGW/RGW/UGW<br />

NF125-SGW/HGW/UGW, NF160-SGW/HGW, NF250-SGW/HGW/UGW<br />

2P<br />

3P<br />

4P<br />

3P<br />

4P<br />

MI-05SW3<br />

MI-2SW4<br />

MI-2SGW3<br />

MI-2SGW4<br />

<br />

MI-2SWFB3<br />

<br />

MI-2SGW3<br />

<br />

● Outside Dimension Diagram<br />

(Front connection, Rear connection, and Plug-in)<br />

33<br />

44<br />

13<br />

70<br />

15<br />

22<br />

<br />

1.5<br />

<br />

<br />

<br />

<br />

<br />

(t13.2)<br />

(<br />

<br />

)<br />

● Drilling Dimension Diagram<br />

(Front connection, Rear connection, and Plug-in)<br />

4ø (ø5.5 and ø7.5 countersunk (rear) (Note 1) );<br />

use M5×0.8 flat countersunk head screws to fix.<br />

31<br />

15.5<br />

50<br />

A<br />

120 (Note 2)<br />

63 (Note 3)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Notes: (1) When the panel plate thickness is<br />

2.3 or more, prepare four holes<br />

(ø5.5 and ø9.5 countersunk (rear)).<br />

(2) These are standard dimensions for<br />

2- and 3-pole models, but can be<br />

altered upon request.<br />

(3) The U series have different<br />

dimensions.<br />

Please contact us for details.<br />

Remarks: (1) Please contact us for outside<br />

dimensions of other models of<br />

different specifications.<br />

(2) These are not isolation-compatible.<br />

9. Handle Lock Devices and Card Holder<br />

Table 5-24<br />

Description (Note 2) <br />

<br />

NF32-SW, NF63-CW/SW/HW<br />

2P<br />

(1)<br />

HLS-05SW2P<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW<br />

MB30-SW, MB50-CW/SW<br />

3P<br />

LC-05SW<br />

HLF-05SW<br />

HLN-05SW<br />

HLS-05SW<br />

NF63-SW/HW<br />

NF125-CW/SW/HW<br />

NF125-CW/SW, NV125-CW/SW/HW<br />

MB100-SW, NV125-RW<br />

4P<br />

2P<br />

3P<br />

LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

(1)<br />

HLS-1SW2P<br />

HLS-1SW<br />

—<br />

CH-P No.5<br />

NF125-SW/HW, NV125-SW/HW<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW<br />

NV250-SEW/HEW, MB225-SW<br />

NV250-RW<br />

Notes: (1) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(2) HL-S types are used for OFF-lock.<br />

Remark: (1) Users are requested to prepare padlocks for HL and HL-S types. (25mm padlock for HL, and 35mm padlock for HL-S.)<br />

4P<br />

2P<br />

3P<br />

4P<br />

LC-2SW<br />

NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW 3P4P LC-2GSW<br />

HLF-2SW<br />

HLN-2SW<br />

(1)<br />

HLF-2GSW(1)<br />

HLN-2GSW<br />

HLS-2SW<br />

HLS-2GSW<br />

HLF3-2GSW<br />

10. IEC 35mm Rail Mounting Adapters<br />

Table 5-25<br />

NF32-SW, NF63-CW/SW/HW<br />

NV32-SW, NV63-CW/SW/HW, MB30-SW<br />

MB50-CW/SW<br />

NF125-CW/SW<br />

NF125-HW, NV125-CW/SW/HW, MB100-SW<br />

<br />

2P<br />

3P<br />

2P<br />

3P<br />

2P<br />

3P<br />

DIN-05SW<br />

DIN-1SW2<br />

DIN-1SW3<br />

CL<br />

5<br />

4<br />

Mounting hook<br />

for IEC 35mm rail<br />

(DIN-05SW)<br />

35<br />

M4×0.7 screw<br />

CL<br />

6<br />

35<br />

7<br />

13<br />

Adapter for<br />

IEC 35mm rail<br />

(DIN-1SW2,<br />

DIN-1SW3)<br />

32


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF32-SW<br />

NF63-SW<br />

MB30-SW<br />

MB50-SW<br />

Type NF32-SW<br />

NF63-CW<br />

NF63-HW<br />

MB50-CW<br />

<strong>Series</strong><br />

Group<br />

Type name<br />

Rated current In (Amp.)<br />

2 ∗1 Number of poles 3<br />

Rated insulation voltage Ui (V)<br />

600<br />

690V –<br />

500V 2.5/1<br />

AC<br />

IEC60947-2 (50/60Hz)<br />

(Icu/Ics)<br />

440V<br />

400V<br />

230V<br />

2.5/1<br />

5/2<br />

7.5/4<br />

DC 250V 2.5/1 –<br />

Rated short-circuit<br />

braking cpacity (kA)<br />

S series<br />

<strong>WS</strong>S G1<br />

Frame size 32<br />

NF32-SW<br />

3 4 6 10<br />

16 20 25<br />

32<br />

C series<br />

<strong>WS</strong>S G1<br />

Suitability for isolation<br />

Utilization category<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

●<br />

A<br />

●<br />

6<br />

2<br />

●<br />

A<br />

●<br />

6<br />

2<br />

✽: Types of DC specifications can be produced upon request.<br />

63<br />

NF63-CW<br />

3 4 6 10<br />

16 20 25 32<br />

40 50 63<br />

S series<br />

<strong>WS</strong>S G1<br />

63<br />

NF63-SW<br />

3 4 6 10<br />

16 20 25 32<br />

40 50 63<br />

2 ∗1 3 2 ∗1 3 4<br />

600<br />

–<br />

2.5/1<br />

2.5/1<br />

5/2<br />

7.5/4<br />

600<br />

–<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

15/8<br />

2.5/1 – 7.5/4 –<br />

●<br />

A<br />

●<br />

6<br />

2<br />

H series<br />

<strong>WS</strong>S G1<br />

63<br />

NF63-HW<br />

10 16 20<br />

25 32 40<br />

50 63<br />

2 ∗1 3 4<br />

690<br />

2.5/1<br />

7.5/4<br />

10/5<br />

10/5<br />

25/13<br />

7.5/4 –<br />

●<br />

A<br />

●<br />

6<br />

2<br />

S series<br />

<strong>WS</strong>S G1<br />

30<br />

MB30-SW<br />

0.8 1.2 1.4<br />

2 2.5 4 5<br />

7.1 8 10 12<br />

16 25<br />

3<br />

500<br />

–<br />

–<br />

2.5/1<br />

7.5/4<br />

7.5/4<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

C series<br />

<strong>WS</strong>S G1<br />

50<br />

MB50-CW<br />

8 10 12<br />

16 25 32<br />

40 45<br />

3<br />

500<br />

–<br />

–<br />

2.5/1<br />

7.5/4<br />

7.5/4<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

S series<br />

<strong>WS</strong>S G1<br />

50<br />

MB50-SW<br />

0.8 1.2<br />

1.4 2 2.5<br />

4 5 7.1<br />

3<br />

500<br />

–<br />

–<br />

7.5/4<br />

7.5/4<br />

15/8<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

■Operating Characteristics<br />

4h<br />

4h<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

AC use (IEC60947-2)<br />

NF30-SW<br />

NF63-CW NF63-SW NF63-HW<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

DC use (IEC60947-2)<br />

NF30-SW<br />

NF63-CW NF63-SW NF63-HW<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

(IEC60947-2)<br />

MB30-SW<br />

MB50-CW MB50-SW<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

1s<br />

Min.<br />

2s<br />

1s<br />

Min.<br />

2s<br />

1s<br />

Min.<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

■Internal Accessories<br />

2-pole<br />

3-pole<br />

Remark: (1) refer to 24.<br />

100% of Rated current<br />

0.02s<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

Left-side<br />

mounting<br />

AL AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

100% of Rated current<br />

Breaker handle<br />

Right-side<br />

mounting<br />

0.02s<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

100% of Rated current<br />

■Temperature Characteristics<br />

Operating time<br />

change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

Rated ambient<br />

Ambient temperature (°C)<br />

40<br />

50<br />

60<br />

■External Accessories<br />

Enclosure<br />

Accessories<br />

Operating handle<br />

Dustproof<br />

Waterproof<br />

Handle lock device<br />

F<br />

S<br />

V<br />

R<br />

S<br />

I<br />

W<br />

LC<br />

(*2)<br />

HL<br />

Type name<br />

F05SW (*1)<br />

S05SW<br />

V05SWF<br />

—<br />

NFS-05SW<br />

NFl-05SW<br />

NFW-05SW<br />

LC-05SW<br />

HLF-05SW<br />

HLN-05SW<br />

HL-S HLS-05SW (*1)<br />

Reference<br />

page<br />

27<br />

28<br />

29<br />

Type name<br />

Ml Ml-05SW3 (*1) 32<br />

Small TC-S TCS-05SW3W (*1)<br />

Large TC-L TCL-05SW3W (*1)<br />

Skeleton TTC TTC-05SW3 (*1)<br />

Rear BTC BTC-05SW3W (*1)<br />

Plug-in PTC PTC-05SW3W (*1)<br />

IEC 35mm rail<br />

32 DIN-05SW 32<br />

mounting adapters<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Reference<br />

page<br />

30<br />

■Standard Attached Parts<br />

(Front connection)<br />

Mounting screw: M4×0.7×55<br />

(2 and 3P: 2pcs, 4P: 4pcs)<br />

(Note)<br />

Insulation barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Note: These are supplied with NF63-SW, NF63-HW, and<br />

MB50-SW models.<br />

33


● NF32-SW, NF63-CW, NF63-SW, NF63-HW, MB30-SW, MB50-CW, MB50-SW<br />

Front connection<br />

49.8<br />

Mounting hole<br />

Insulation barrier<br />

(removable)<br />

50<br />

M5×0.8 screw<br />

(M6 for 63A)<br />

24<br />

Applicable<br />

wire size:1.6mm-dia.to 22mm 2<br />

M4×0.7 taps<br />

or 5mm dia.hole<br />

Breaker<br />

Screw terminal<br />

111<br />

130<br />

84<br />

50<br />

ø8.5<br />

ø4.5<br />

111<br />

25<br />

Trip button<br />

22<br />

50<br />

25<br />

75<br />

Neutral pole<br />

61<br />

45<br />

ø5.5<br />

(6.5mm-diameter for 63A)<br />

6<br />

25<br />

25<br />

50<br />

75<br />

100<br />

68<br />

12.5 max.<br />

2-pole<br />

3-pole<br />

4-pole<br />

2-pole<br />

3-pole<br />

4-pole<br />

4<br />

90<br />

72<br />

(Conductor thickness<br />

t=5 max.)<br />

Conductor drilling<br />

for direct connection<br />

Drilling plan<br />

Rear connection<br />

Mounting panel<br />

t=3.2max<br />

Insulation tube<br />

M4×0.7 taps<br />

or 5mm-dia.hole<br />

Breaker<br />

2-pole<br />

4-pole<br />

3-pole<br />

Breaker<br />

6<br />

8<br />

111<br />

111<br />

R1<br />

52<br />

27<br />

68<br />

min.<br />

42<br />

M6 screw<br />

50<br />

M4×0.7 screw<br />

for mounting breaker<br />

25<br />

25<br />

50<br />

ø14<br />

25<br />

25<br />

75<br />

50<br />

70<br />

22.5<br />

72<br />

2-pole<br />

3-pole<br />

4-pole<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

Drilling plan<br />

Front-panel cutout<br />

Plug-in<br />

Mounting panel<br />

Plug-in terminal block<br />

M5×0.8<br />

terminal block mounting screw<br />

3<br />

3-pole<br />

80<br />

50<br />

4-pole<br />

105<br />

75<br />

25<br />

Breaker (plug-in terminal block)<br />

5.5 15.5<br />

11<br />

83.5<br />

85<br />

180<br />

111<br />

16.5 max.<br />

7<br />

Center line of<br />

breaker body<br />

54<br />

54 80 54<br />

10<br />

Details of terminal<br />

21<br />

89<br />

30<br />

M6 screw<br />

25<br />

55<br />

2-pole<br />

ø6.5<br />

Conductor drilling<br />

for direct connection<br />

25<br />

57 82<br />

2-pole<br />

3-pole<br />

Cutout and drilling plan<br />

50<br />

107<br />

4-pole<br />

6mm-dia.hole or<br />

or M5×0.8 taps<br />

34


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF125-CW<br />

NF125-HW<br />

NF125-SW<br />

MB100-SW<br />

Type NF125-CW<br />

<strong>Series</strong> C series S series H series S series<br />

Group <strong>WS</strong>S G2 <strong>WS</strong>S G2 <strong>WS</strong>S G2 <strong>WS</strong>S G2<br />

Frame size 125 125 125 100<br />

Type name NF125-CW NF125-SW NF125-HW MB100-SW<br />

Rated current In (Amp.)<br />

Number of poles 2 3 2 3 4 2 3 4<br />

3<br />

Rated insulation voltage Ui (V)<br />

Rated short-circuit<br />

braking cpacity (kA)<br />

IEC60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC ∗1<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

250V<br />

400V<br />

500V<br />

Suitability for isolation<br />

Utilization category<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

50 63 80<br />

100 125<br />

600<br />

–<br />

7.5/4<br />

10/5<br />

10/5<br />

30/15<br />

7.5/4 –<br />

– 7.5/4<br />

15/8 – 40/20 –<br />

– 15/8 – 40/20<br />

– 15/8 – 40/20<br />

∗1: When wired as shown at the bottom of page 13, 3-pole models can be used for up to 400 V DC, and<br />

4-pole models for up to 500 V DC.<br />

–<br />

●<br />

A<br />

●<br />

8<br />

3<br />

16 20 32 40<br />

50 63 80<br />

100 125<br />

690<br />

8/4<br />

18/9<br />

25/13<br />

30/15<br />

50/25<br />

●<br />

A<br />

●<br />

8<br />

3<br />

16 20 32 40<br />

50 63 80<br />

100<br />

690<br />

10/5<br />

30/15<br />

50/25<br />

50/25<br />

100/50<br />

●<br />

A<br />

●<br />

8<br />

3<br />

(12.5) (16)<br />

(25) 32 (40)<br />

45 63 71<br />

90 100<br />

500<br />

–<br />

–<br />

25/13<br />

30/15<br />

50/25<br />

–<br />

–<br />

–<br />

●<br />

A<br />

●<br />

8<br />

3<br />

■Operating Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

Time-delay trip<br />

NF125-CW 50A~100A<br />

NF125-SW 40A~100A<br />

NF125-HW 40A~100A<br />

MB100-SW 40A~100A<br />

(IEC 60947-2)<br />

Max.<br />

(60A~100A)<br />

Max. (40A~50A)<br />

AC<br />

DC<br />

Max. total<br />

breaking<br />

time<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

Time-delay trip<br />

Max.<br />

NF125-SW 16A~20A<br />

NF125-HW 16A~20A<br />

MB125-SW 12.5A~20A<br />

(IEC 60947-2)<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50 60 70<br />

AC<br />

DC<br />

Instantaneous trip<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

NF125-CW 125A<br />

NF125-SW 125A<br />

(IEC 60947-2)<br />

AC<br />

Max.<br />

DC<br />

Max. total<br />

breaking time<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50 1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

Min.<br />

NF125-SW 32A<br />

NF63-HRW 32A<br />

NF125-HW 32A<br />

(IEC 60947-2)<br />

Max.<br />

AC<br />

DC<br />

Max. total<br />

breaking<br />

time<br />

100% of Rated current<br />

100% of Rated current<br />

Max. total<br />

breaking time<br />

100% of Rated current 100% of Rated current<br />

Remark: (1) Only AC characteristics are available for the model MB100-SW.<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

2-pole<br />

3, 4-pole<br />

Remark: (1) refer to 24.<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Enclosure<br />

Closed-box<br />

Dustproof<br />

Waterproof<br />

Handle lock device<br />

F F1SW (*1)<br />

S<br />

V<br />

R<br />

S<br />

I<br />

W<br />

LC<br />

()<br />

HL<br />

HL-S<br />

<br />

S1SW<br />

V1SW ()<br />

R1SW<br />

NFS-1SW<br />

NFl-1SW<br />

NFW-1SW/1HW<br />

LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

HLS-1SW ()()<br />

Reference<br />

page<br />

27<br />

28<br />

29<br />

32<br />

Terminal cover<br />

Left-side<br />

mounting<br />

AL<br />

Accessories<br />

Mechanical<br />

interlock<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

Ml Ml-05SW3 () 32<br />

TC-S TCS-1SW3W ()<br />

TC-L TCL-1SW3W ()<br />

TTC TTC-1SW3 ()<br />

BTC BTC-1SW3W ()<br />

PTC PTC-1SW3W ()<br />

IEC 35mm rail<br />

mounting adapters<br />

Electrical<br />

operation device<br />

30<br />

DIN-1SW3 () 32<br />

MDS-NF1SWE ()<br />

Current rating (%)<br />

30<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

Reference<br />

page<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) Attach the letter "F" to the end of designation for a fixed type.<br />

(*3) Specify the working voltage. An order of MB100-SW should be placed at the same time as an order of circuit breaker main body.<br />

(*4) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

Rated ambient<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

■Standard Attached Parts<br />

(Front connection)<br />

Mounting screw: M4×0.7×55<br />

(2 and 3P: 2pcs, 4P: 4pcs)<br />

(Note)<br />

Insulation barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Note: These are supplied with NF125-SW, NF125-HW, and<br />

MB100-SW models.<br />

35


● NF125-CW, NF125-SW, NF125-HW, MB100-SW<br />

Front connection<br />

CL<br />

Mounting hole<br />

LC<br />

Insulation barrier<br />

(removable)<br />

LC<br />

50<br />

M8 screw<br />

24<br />

Solderless terminal<br />

for wire size<br />

14~2/0AWG CU/AL<br />

LC<br />

LC<br />

Breaker<br />

LC<br />

LC<br />

112<br />

130<br />

84<br />

50<br />

Wire connection<br />

LC<br />

110- 111<br />

30<br />

Trip<br />

button<br />

22<br />

30<br />

45<br />

ø8.5<br />

30<br />

30<br />

60<br />

60<br />

90<br />

90<br />

120<br />

Neutral<br />

pole<br />

4<br />

61<br />

68<br />

72<br />

19 max.<br />

8<br />

2-pole<br />

3-pole<br />

M4X0.7 taps<br />

or 5mm-dia. hole<br />

4-pole<br />

2-pole<br />

3-pole<br />

4-pole<br />

90<br />

(Conductor thickness<br />

t=5 max.)<br />

Drilling plan<br />

Conductor drilling<br />

for direct connection<br />

Rear connection<br />

Mounting plate<br />

t=3.2 max.<br />

102<br />

52<br />

Mounting base<br />

Stud rotatable<br />

by 90°<br />

4-pole<br />

3-pole<br />

2-pole<br />

LC<br />

CL<br />

Breaker<br />

CL<br />

2-pole<br />

LC<br />

4-pole<br />

3-pole CL<br />

CL<br />

Breaker<br />

CL<br />

15<br />

Connection<br />

allowance<br />

112<br />

6<br />

CL<br />

110-111<br />

112<br />

LC<br />

R1<br />

R1<br />

16<br />

52<br />

8.5<br />

68<br />

72<br />

2.5<br />

15<br />

54.5<br />

104.5<br />

M8 bolt<br />

2.5<br />

15<br />

5<br />

60<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulation<br />

tube<br />

30<br />

2-pole<br />

30<br />

60<br />

3-pole<br />

ø18<br />

30<br />

30<br />

90<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

4-pole<br />

57<br />

86<br />

Front-panel cutout<br />

28<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

Drilling plan<br />

Plug-in<br />

3-pole<br />

4-pole<br />

Mounting plate<br />

Plug-in terminal block<br />

M5×0.8<br />

Terminal block<br />

mounting screw<br />

95<br />

60<br />

125<br />

90<br />

30<br />

CL<br />

Breaker (plug-in terminal block)<br />

LC<br />

LC<br />

5.5<br />

20<br />

LC<br />

11<br />

98<br />

190<br />

134<br />

16.5 max.<br />

12<br />

LC<br />

54<br />

56 94 56<br />

12.5<br />

21<br />

89<br />

30<br />

M8 screw<br />

30<br />

65<br />

ø8.5<br />

30 60<br />

67 97<br />

127<br />

Details of terminal<br />

2-pole<br />

Conductor drilling<br />

for direct connection<br />

2-pole 3-pole<br />

Drilling plan<br />

4-pole<br />

6mm-dia. hole<br />

or M5×0.8 taps<br />

Remark: 2-pole model of NF125-HW are 3-pole model with the central pole removed.<br />

36


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF250-CW<br />

NF250-HW<br />

NF160-HW<br />

NF250-SW<br />

NF160-SW<br />

MB225-SW<br />

<strong>Series</strong><br />

Group<br />

Frame size 160<br />

160<br />

250<br />

Type name<br />

Rated current In (Amp.)<br />

S series<br />

<strong>WS</strong>S G3<br />

NF160-SW<br />

H series<br />

<strong>WS</strong>S G3<br />

NF160-HW<br />

125 150 160 125 150 160<br />

C series<br />

<strong>WS</strong>S G3<br />

NF250-CW<br />

125 150 175<br />

200 225 250<br />

S series<br />

<strong>WS</strong>S G3<br />

250<br />

NF250-SW<br />

125 150 175<br />

200 225 250<br />

H series<br />

<strong>WS</strong>S G3<br />

250<br />

NF250-HW<br />

125 150 175<br />

200 225 250<br />

S series<br />

<strong>WS</strong>S G3<br />

225<br />

MB225-SW<br />

125 150 175<br />

200 225<br />

Type NF250-CW<br />

Number of poles 2 3 4 2 3 4 2 3 2 3 4 2 3 4<br />

Rated insulation voltage Ui (V)<br />

690<br />

690<br />

600<br />

690<br />

690<br />

690V –<br />

5/3<br />

–<br />

–<br />

5/3<br />

500V 15/8<br />

30/8<br />

10/5<br />

15/8<br />

30/8<br />

AC<br />

(50/60Hz) 440V 25/13 50/13 15/8 25/13 50/13<br />

IEC60947-2<br />

(Icu/Ics)<br />

400V<br />

230V<br />

30/15<br />

50/25<br />

50/13<br />

100/25<br />

18/9<br />

35/18<br />

30/15<br />

50/25<br />

50/13<br />

100/25<br />

250V 15/8 – 40/20 – 10/5 – 15/8 – 40/20 –<br />

DC 400V – 15/8 – – 40/20 – – 10/5 – 15/8 – – 40/20 –<br />

500V – 15/8 – 40/20 –<br />

– 15/8 – 40/20<br />

Suitability for isolation<br />

Utilization category<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

●<br />

A<br />

●<br />

6<br />

2<br />

●<br />

A<br />

●<br />

6<br />

2<br />

●<br />

A<br />

●<br />

6<br />

2<br />

●<br />

A<br />

●<br />

6<br />

2<br />

●<br />

A<br />

●<br />

6<br />

2<br />

Rated short-circuit<br />

braking cpacity (kA)<br />

∗1: When wired as shown at the bottom of page 13, 3-pole models can be used for up to 400 V DC, and 4-pole models for<br />

up to 500 V DC.<br />

3<br />

500<br />

–<br />

–<br />

25/13<br />

30/15<br />

50/25<br />

–<br />

–<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

■Operating Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

NF250-CW<br />

NF250-SW<br />

MB225-SW<br />

NF160-SW<br />

30min<br />

NF250-HW NF160-HW<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

Max.<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

2s<br />

1s<br />

0.5s<br />

250A AC<br />

0.2s<br />

Max. total<br />

breaking<br />

125225A AC<br />

250A DC<br />

0.1s<br />

time<br />

125225A DC<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

100% of Rated current<br />

■Ambient Compensating Curve<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

Remark: The reference ambient temperature for IEC models is 30°C.<br />

■Internal Accessories<br />

Remark: (1) refer to 24.<br />

Rated ambient<br />

Left-side<br />

mounting<br />

<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

■External Accessories<br />

Enclosure<br />

Accessories<br />

Operating handle<br />

Dustproof<br />

Waterproof<br />

Handle lock device<br />

F F2SW<br />

S S2SW<br />

V V2SW (*3)<br />

R R2SW<br />

S NFS-2SW (*5)<br />

I<br />

W<br />

LC<br />

(*4)<br />

HL<br />

HL-S<br />

Type name<br />

NFl-2SW<br />

NFW-2SW<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

Reference<br />

page<br />

27<br />

28<br />

29<br />

32<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*1) 32<br />

Small TC-S TCS-2SW3W (*1)<br />

Large TC-L TCL-2SW3W (*1)<br />

Skeleton TTC TTC-2SW3 (*1)<br />

Rear BTC BTC-2SW3W (*1)<br />

Plug-in PTC PTC-2SW3W (*1)<br />

Electrical<br />

operation device<br />

MDS-NF2SWE (*2)<br />

Reference<br />

page<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) Specify the working voltage. An order of MB225-SW should be placed at the same time as an order of circuit breaker main body.<br />

(*3) Attach the letter "F" to the end of designation for a fixed type.<br />

(*4) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*5) NF160-HW, NF250-HW model cannot be produced.<br />

30<br />

■Standard Attached Parts<br />

(Front connection)<br />

Mounting screw: M4×0.7×55<br />

(2 and 3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

37


● NF250-CW, NF250-SW, NF250-HW, NF160-SW, NF160-HW, MB225-SW<br />

Front connection<br />

Mounting hole<br />

Insulating barrier<br />

(removable)<br />

144<br />

165 100<br />

102<br />

M8 bolt<br />

(Hex-soket)<br />

50<br />

24<br />

30<br />

Solderless terminal<br />

for wire size<br />

125 175A 14 95mm 2<br />

200 250A 70 125mm 2<br />

Wire connection<br />

Breaker<br />

126<br />

ø4.5<br />

ø8.5<br />

Trip button<br />

22<br />

70<br />

105<br />

3-pole<br />

35<br />

105<br />

140<br />

4-pole<br />

Neutral<br />

pole<br />

100<br />

ø8.5<br />

45<br />

61<br />

68<br />

4 72<br />

92<br />

23 max.<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

10<br />

35<br />

3-pole<br />

M4×0.7 taps<br />

or ø5<br />

Drilling plan<br />

35<br />

4-pole<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating<br />

tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Connection<br />

allowance<br />

22<br />

20<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

52<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15<br />

ø9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or ø5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

32.5<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal block<br />

Breaker (Terminal block)<br />

200<br />

14<br />

6<br />

28 144<br />

34.5<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

153<br />

54<br />

80 58.5<br />

58.5<br />

18<br />

86<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

derection only<br />

20<br />

70<br />

ø9<br />

M8 bolt<br />

Insulating barrier<br />

70<br />

ø7<br />

107<br />

3-pole<br />

Drilling plan<br />

105<br />

142<br />

4-pole<br />

Remarks: 1. 2-pole models are 3-pole models with the central pole removed.<br />

2. Only 2- and 3-pole models are available for the model of NF250-CW, and only 3-pole models are available<br />

for the model of MB225-SW.<br />

38


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF250-SGW<br />

NF160-SGW<br />

NF125-SGW<br />

NF250-HGW<br />

NF160-HGW<br />

NF125-HGW<br />

<strong>Series</strong><br />

Group<br />

Frame size<br />

Type name<br />

Rated current In (Amp.)<br />

S series<br />

<strong>WS</strong>S G4<br />

125<br />

NF125-SGW<br />

RT<br />

16–25, 25–40,<br />

40–63, 63–100,<br />

80–125<br />

S series<br />

<strong>WS</strong>S G4<br />

125<br />

NF125-SGW<br />

RE<br />

16–32, 32–63,<br />

63–100, 75–125<br />

H series<br />

<strong>WS</strong>S G4<br />

125<br />

NF125-HGW<br />

RT<br />

16–25, 25–40,<br />

40–63, 63–100,<br />

80–125<br />

H series<br />

<strong>WS</strong>S G4<br />

125<br />

NF125-HGW<br />

RE<br />

16–32, 32–63,<br />

63–100, 75–125<br />

S series<br />

<strong>WS</strong>S G4<br />

160<br />

NF160-SGW<br />

RT<br />

125–160<br />

S series<br />

<strong>WS</strong>S G4<br />

160<br />

NF160-SGW<br />

RE<br />

80–160<br />

Number of poles<br />

2 3 4<br />

3 4<br />

2 3 4<br />

3 4<br />

2 3 4<br />

3 4<br />

Rated insulation voltage Ui (V)<br />

690<br />

690<br />

690<br />

690<br />

690<br />

690<br />

Rated short-circuit<br />

braking cpacity (kA)<br />

IEC<br />

60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC ∗1<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

300V<br />

500V<br />

600V<br />

20/20<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

– 20/20<br />

–<br />

–<br />

– 20/20<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

–<br />

40/40<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

– 40/40<br />

–<br />

–<br />

– 40/40<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

–<br />

–<br />

–<br />

20/20<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

– 20/20<br />

–<br />

–<br />

– 20/20<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

–<br />

Suitability for isolation<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Utilization category<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

Reverse connection (terminals unmarked)<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Rated impulse withstand voltage Uimp (kV)<br />

8<br />

8<br />

8<br />

8<br />

8<br />

8<br />

Pollution degree<br />

3<br />

3<br />

3<br />

3<br />

3<br />

3<br />

<strong>Series</strong><br />

H series<br />

H series<br />

S series<br />

S series<br />

H series<br />

H series<br />

Group<br />

<strong>WS</strong>S G4<br />

<strong>WS</strong>S G4<br />

<strong>WS</strong>S G4<br />

<strong>WS</strong>S G4<br />

<strong>WS</strong>S G4<br />

<strong>WS</strong>S G4<br />

Frame size 160<br />

160<br />

250<br />

250<br />

250<br />

250<br />

Type name<br />

NF160-HGW<br />

RT<br />

NF160-HGW<br />

RE<br />

NF250-SGW<br />

RT<br />

NF250-SGW<br />

RE<br />

NF250-HGW<br />

RT<br />

NF250-HGW<br />

RE<br />

Rated current In (Amp.)<br />

125–160<br />

80–160<br />

125–160,<br />

160–250<br />

125–250<br />

125–160<br />

160–250<br />

125–250<br />

Number of poles<br />

2 3 4<br />

3 4<br />

2 3 4<br />

3 4<br />

2 3 4<br />

3 4<br />

Rated insulation voltage Ui (V)<br />

690<br />

690<br />

690<br />

690<br />

690<br />

690<br />

Type NF250-SGW<br />

Rated short-circuit<br />

braking cpacity (kA)<br />

IEC<br />

60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC ∗1<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

300V<br />

500V<br />

600V<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

40/40 –<br />

– 40/40 –<br />

– 40/40<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

–<br />

–<br />

–<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

20/20 –<br />

– 20/20 –<br />

– 20/20<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

–<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

40/40 –<br />

– 40/40 –<br />

– 40/40<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

–<br />

–<br />

–<br />

Suitability for isolation<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Utilization category<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

Reverse connection (terminals unmarked)<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Rated impulse withstand voltage Uimp (kV)<br />

8<br />

8<br />

8<br />

8<br />

8<br />

8<br />

Pollution degree<br />

3<br />

3<br />

3<br />

3<br />

3<br />

3<br />

■Operating Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

Pre-alarm<br />

pickup current IP<br />

I rx(0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0) 10%<br />

Pre-alarm<br />

operating time TP<br />

L<br />

T = T 20%<br />

P 2<br />

(at 200%)<br />

0.6 0.7<br />

Min.<br />

Time-delay trip<br />

INST pickup current I<br />

Inx(414) 15%<br />

×100% of Rated current<br />

I<br />

Thermal-Adjustable types<br />

NF125-SGW/HGW 25-40A (Rated current In=40A)<br />

16-25A (Rated current In=25A)<br />

Max.<br />

LTD operating time TL<br />

12-60-80-100s 20%<br />

(at 200%)<br />

NF160-SGW NF160-HGW<br />

Note)<br />

Cureent setting Ir Rated current In<br />

80~160A 160A<br />

(Adjustable)<br />

Max.total breaking<br />

time<br />

×100% of Current setting<br />

Note) Instantaneous tripping current (×100% of In)<br />

AC<br />

IEC 60947-2<br />

STD pickup current Is<br />

I rx(2-2.5-3-3.5-4<br />

-5-6-7-8-10) 15%<br />

Operating time<br />

STD operating time Ts<br />

0.30.06s<br />

0.20.04s<br />

0.10.03s<br />

0.060.02s<br />

1 1.3 3<br />

7<br />

2 4 30<br />

5 6 10 15 20 40<br />

DC<br />

Instantaneous trip<br />

current ratio<br />

AC DC<br />

x In (%) x In (%)<br />

1000200 1300260<br />

Max. total<br />

breaking<br />

time<br />

Instantaneous trip<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

∗1: Use either 2-pole. When wired as shown at the bottom of page 13, 3-pole models can be used for up to 500 V DC, and 4-pole models for up to 600V DC.<br />

Min.<br />

Time-delay trip<br />

Pre-alarm<br />

pickup current IP<br />

I rx(0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0) 10%<br />

Pre-alarm<br />

operating time TP<br />

T<br />

T P= L 20%<br />

2<br />

(at 200%)<br />

×100% of Rated current<br />

INST pickup current I<br />

Inx(414) 15%<br />

Thermal-Adjustable types<br />

NF125-SGW/HGW 63-100A (Rated current In=100A)<br />

40-63A (Rated current In=63A)<br />

I<br />

LTD operating time TL<br />

12-60-80-100s 20%<br />

(at 200%)<br />

×100% of Current setting<br />

Max.total breaking<br />

time<br />

Operating time<br />

Note)<br />

Cureent setting Ir Rated current In<br />

125~250A 250A<br />

(Adjustable)<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

NF250-SGW NF250-HGW<br />

0.01s<br />

STD pickup current Is<br />

I rx(2-2.5-3-3.5-4<br />

-5-6-7-8-10) 15%<br />

STD operating time Ts<br />

0.30.06s<br />

0.20.04s<br />

0.10.03s<br />

0.060.02s<br />

0.6 0.7 1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

Note) Instantaneous tripping current (×100% of In)<br />

AC<br />

Max.<br />

IEC 60947-2<br />

DC<br />

Instantaneous trip<br />

current ratio<br />

AC DC<br />

x In (%) x In (%)<br />

1000200<br />

1300260<br />

Max. total<br />

breaking<br />

time<br />

Instantaneous trip<br />

Min.<br />

Time-delay trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

Current rating (%)<br />

×100% of Rated current<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

Max.<br />

AC<br />

(Adjustable range)<br />

DC<br />

(Adjustable range)<br />

Thermal-Adjustable types<br />

NF250-SGW/HGW 160-250A (Rated current In=250A)<br />

NF160-SGW/HGW 125-160A (Rated current In=160A)<br />

NF125-SGW/HGW 80-125A (Rated current In=125A)<br />

Instantaneous trip adjustment<br />

range<br />

Position<br />

of notch<br />

4<br />

6<br />

8<br />

10<br />

IEC 60947-2<br />

AC x In (%)<br />

Instantaneous trip<br />

40080<br />

600<br />

800<br />

1000200<br />

DC x In (%)<br />

520104<br />

780<br />

1040<br />

1300260<br />

Max. total<br />

breaking<br />

time<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

0 10 20 30 40 50 60<br />

Rated ambient<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

Pre-alarm<br />

pickup current I<br />

I rx(0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0)<br />

Pre-alarm<br />

operating time T<br />

L<br />

T = T 20%<br />

P 2<br />

(at 200%)<br />

0.6 0.7<br />

P<br />

10%<br />

P<br />

INST pickup current I<br />

Inx(414) 15%<br />

I<br />

LTD operating time T<br />

12-60-80-100s 20%<br />

(at 200%)<br />

×100% of Current setting<br />

NF125-SGW NF125-HGW<br />

Note)<br />

Cureent setting Ir Rated current In<br />

16~32A 32A<br />

32~63A 63A<br />

63~100A 100A<br />

75~125A 125A<br />

(Adjustable)<br />

L<br />

Max.total breaking<br />

time<br />

Note) Instantaneous tripping current (×100% of In)<br />

■Ambient Compensating Curve<br />

Derating of Load current (%)<br />

STD pickup current I<br />

I rx(2-2.5-3-3.5-4<br />

-5-6-7-8-10)<br />

STD operating time T<br />

0.30.06s<br />

0.20.04s<br />

0.10.03s<br />

0.060.02s<br />

1 1.3 3<br />

7<br />

2 4 30<br />

5 6 10 15 20 40<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

–10<br />

Ambient Compensation<br />

NF125-SGW NF125-HGW<br />

NF160-SGW NF160-HGW<br />

NF250-SGW NF250-HGW<br />

0<br />

Rated ambient<br />

Ambient temperature (°C)<br />

s<br />

15%<br />

10 20 30 40 50 60<br />

s<br />

39<br />

■Internal Accessories<br />

Right-side<br />

mounting<br />

SHT or UVT<br />

Remark: (1) refer to 24.<br />

Operating handle<br />

Left-side<br />

mounting<br />

<br />

<br />

Lead wire direction<br />

■External Accessories<br />

Enclosure<br />

Accessories<br />

Operating handle<br />

Dustproof<br />

Waterproof<br />

Type name<br />

<br />

Handle lock device<br />

<br />

<br />

Reference<br />

page<br />

<br />

Mechanical<br />

<br />

<br />

interlock<br />

<br />

<br />

<br />

<br />

<br />

–<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Terminal cover<br />

Accessories<br />

Electrical<br />

operation device<br />

Type name<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Reference<br />

page<br />

<br />

<br />

Notes:<br />

(*1) The designation depends<br />

on the number of poles.<br />

Refer to the reference page.<br />

(*2) HLF types are used for<br />

OFF-lock, and HLN types<br />

for ON-lock.<br />

(*3) Attach the letter “F” to the<br />

end of designation for a<br />

fixed type.


● NF250-SGW, NF160-SGW, NF125-SGW, NF250-HGW, NF160-HGW, NF125-HGW<br />

Front connection<br />

Mounting hole<br />

Insulating barrier<br />

(removable)<br />

M8 bolt<br />

(Hex-soket)<br />

24<br />

Solderless terminal<br />

for wire size<br />

2.5 185mm 2<br />

10<br />

Breaker<br />

Trip<br />

button<br />

22<br />

70<br />

35<br />

105<br />

144<br />

165 50<br />

50<br />

Neutral<br />

pole<br />

112<br />

50<br />

ø8.5<br />

63<br />

79<br />

ø4.5<br />

22<br />

6.1<br />

Hex-socket set screw<br />

Wire connection<br />

ø8.5<br />

10<br />

35<br />

M4×0.7 taps<br />

or ø5<br />

35<br />

126<br />

105<br />

3-pole<br />

140<br />

4-pole<br />

4<br />

86<br />

90<br />

24 max.<br />

(Bus t max.=7)<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

110<br />

Bus drilling for<br />

direct connection<br />

Rear connection<br />

Insulating tube<br />

4-pole<br />

4-pole<br />

Mounting plate<br />

t max.=3.2<br />

Stud can be<br />

rotated 90°<br />

3-pole<br />

Breaker<br />

3-pole<br />

Breaker<br />

Connection<br />

allowance<br />

22<br />

20<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

52<br />

86<br />

90<br />

15<br />

71<br />

106<br />

15<br />

ø9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or ø5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-panel cutout<br />

32.5<br />

Plug-in<br />

Plug-in terminal block<br />

4-pole<br />

Breaker (Terminal block)<br />

Mounting plate<br />

15<br />

86<br />

30<br />

45<br />

12<br />

M8 bolt<br />

(Hex-soket)<br />

96<br />

M6<br />

Terminal block<br />

mounting screw<br />

4<br />

120<br />

48 144<br />

54.5<br />

200<br />

103<br />

Stud can be<br />

rotated 90°<br />

Connection<br />

allowance<br />

10 48<br />

20<br />

3-pole<br />

70<br />

110<br />

ø9 M8bolt<br />

Insulating barrier<br />

(removable)<br />

70<br />

ø7<br />

107<br />

3-pole<br />

Drilling plan<br />

105<br />

142<br />

4-pole<br />

66<br />

54 94 54<br />

Remark: 2-pole models are 3-pole models with the central pole removed.<br />

40


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF250-RGW<br />

NF125-RGW<br />

NF250-UGW<br />

NF125-UGW<br />

<strong>Series</strong><br />

Group<br />

Frame size<br />

Type name<br />

<strong>WS</strong>S G4<br />

125<br />

NF125-RGW<br />

RT<br />

<strong>WS</strong>S G4<br />

125<br />

NF125-UGW<br />

RT<br />

U series<br />

<strong>WS</strong>S G4<br />

250 250<br />

NF250-RGW<br />

RT<br />

<strong>WS</strong>S G4<br />

NF250-UGW<br />

RT<br />

Rated current In (Amp.)<br />

16–25 25–40<br />

40–63 63–100<br />

16–25 25–40<br />

40–63 63–100<br />

125–160<br />

160–225<br />

125–160<br />

160–225<br />

Type NF250-UGW<br />

■Operating Characteristics<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated short-circuit<br />

braking cpacity (kA)<br />

IEC60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

300V<br />

500V<br />

2<br />

3<br />

2 3 4<br />

690<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

690<br />

30/30<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

40/40<br />

–<br />

–<br />

40/40<br />

40/40<br />

–<br />

–<br />

40/40 –<br />

2 3 2 3 4<br />

690<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

690<br />

30/30<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

40/40<br />

–<br />

–<br />

40/40<br />

40/40<br />

–<br />

–<br />

40/40 –<br />

600V<br />

–<br />

– 40/40 –<br />

–<br />

Suitability for isolation<br />

●<br />

●<br />

●<br />

●<br />

Utilization category<br />

A<br />

A<br />

A<br />

A<br />

Reverse connection (terminals unmarked)<br />

●<br />

●<br />

●<br />

●<br />

Rated impulse withstand voltage Uimp (kV) 8<br />

8<br />

8<br />

8<br />

Pollution degree<br />

3<br />

3<br />

3<br />

3<br />

Note: When wired as shown at the bottom of page 13, 3-pole models can be used for up to 400 V DC, and 4-pole<br />

models for up to 600 V DC.<br />

40/40<br />

4h<br />

4h<br />

4h<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Thermal-Adjustable types<br />

NF250-RGW/UGW 160-225A (Rated current In=225A)<br />

125-160A (Rated current In=160A)<br />

IEC 60947-2<br />

Instantaneous trip adjustment<br />

range<br />

Position AC DC<br />

of notch x In (%) x In (%)<br />

4 400±80 520±104<br />

6 600 780<br />

8 800 1040<br />

10 1000±200 1300±260<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Thermal-Adjustable types<br />

NF125-RGW/UGW 63-100A (Rated current In=100A)<br />

40-63A (Rated current In=63A)<br />

IEC 60947-2<br />

Instantaneous trip<br />

current ratio<br />

AC DC<br />

x In (%) x In (%)<br />

Max. 1000±200 1300±260<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Thermal-Adjustable types<br />

NF125-RGW/UGW 25-40A (Rated current In=40A)<br />

16-25A (Rated current In=25A)<br />

IEC 60947-2<br />

Instantaneous trip<br />

current ratio<br />

AC DC<br />

x In (%) x In (%)<br />

1000±200 1300±260<br />

Max.<br />

2s<br />

2s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

AC<br />

(Adjustable range)<br />

DC<br />

(Adjustable range)<br />

Max. total<br />

breaking<br />

time<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

AC<br />

DC<br />

Max. total<br />

breaking<br />

time<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

AC<br />

DC<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

×100% of Rated current ×100% of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

80<br />

–10<br />

0 10 20 30 40 50 60<br />

Remark: (1) refer to 24.<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

Remark: The reference ambient temperature for IEC models is 30°C.<br />

■External Accessories<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

F –<br />

–<br />

Operating handle<br />

S –<br />

V<br />

R<br />

V2GUW<br />

R2GUW<br />

28<br />

29<br />

Dustproof<br />

S –<br />

I –<br />

–<br />

Waterproof W –<br />

Mechanical interlock MI MI-05SW3 (*1) 32<br />

Electrical operation device<br />

(*2) 30<br />

Enclosure<br />

Small<br />

Large<br />

Skeleton<br />

TC-S<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) An order should be placed at the same time as an order of circuit breaker main body.<br />

(*3) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

41<br />

Terminal cover<br />

Accessories<br />

Rear<br />

Plug-in<br />

Handle lock<br />

device<br />

TC-L<br />

TTC<br />

BTC<br />

Type name<br />

TCS-2GSW3W (*1)<br />

TCL-2GSW3W (*1)<br />

TTC-2GSW3 (*1)<br />

BTC-2GSW3W (*1)<br />

PTC PTC-2GSW3W (*1)<br />

LC LC-2GSW<br />

(*3) HLF-2GSW<br />

HL HLN-2GSW<br />

HL-S HLS-2GSW<br />

Reference<br />

page<br />

30<br />

32<br />

■Standard Attached Parts<br />

(Front connection)<br />

Mounting screw: M4×0.7×55 (4pcs)


● NF250-RGW, NF125-RGW, NF250-UGW, NF125-UGW<br />

Front connection<br />

Mounting hole<br />

Insulating barrier<br />

(removable)<br />

26.5<br />

M8 bolt<br />

(Hex-soket)<br />

24<br />

Solderless terminal<br />

for wire size<br />

2.5 185mm 2<br />

10<br />

Breaker<br />

Trip<br />

button<br />

22<br />

70<br />

105<br />

3-pole<br />

35<br />

105<br />

140<br />

4-pole<br />

219<br />

50 240<br />

50<br />

Neutral<br />

pole<br />

75<br />

165<br />

112<br />

50<br />

ø8.5<br />

86<br />

4 90<br />

110<br />

63<br />

79<br />

ø4.5<br />

22<br />

24 max.<br />

ø8.5<br />

10<br />

6.1<br />

Hex-socket set screw<br />

Wire connection<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

35<br />

3-pole<br />

M4×0.7 taps<br />

or ø5<br />

35<br />

Drilling plan<br />

4-pole<br />

201<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

73<br />

108<br />

Connection<br />

allowance<br />

22<br />

20<br />

219<br />

8<br />

201<br />

219<br />

R1<br />

11.5<br />

52<br />

15<br />

86 71<br />

90 106<br />

15<br />

ø9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or ø5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

32.5<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-panel cutout<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal<br />

block<br />

Breaker<br />

(Terminal block)<br />

275<br />

14<br />

6<br />

34.5<br />

219<br />

28<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

153<br />

129<br />

58.5 155<br />

58.5<br />

18<br />

104<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

derection only<br />

20<br />

70<br />

ø9 M8bolt<br />

Insulating<br />

barrier<br />

70<br />

107<br />

Drilling plan<br />

ø7<br />

Remark: 2-pole models are 3-pole models with the central pole removed.<br />

42


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV32-SW<br />

NV63-SW<br />

NV63-CW<br />

NV63-HW<br />

<strong>Series</strong> S series C series<br />

Group <strong>WS</strong>S G1 <strong>WS</strong>S G1<br />

Frame size 32 63<br />

Type name NV32-SW NV63-CW<br />

Rated current In (Amp.)<br />

S series<br />

<strong>WS</strong>S G1<br />

63<br />

NV63-SW<br />

Number of poles 3 3 3 3<br />

Rated operational voltage Ue (V AC)<br />

Rated current sensitivity I∆n (mA)<br />

High-speed type<br />

Max. operating time at 5I∆n (s)<br />

Earth-leakage indication system<br />

Rated breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC380V<br />

AC230V<br />

6 10 16<br />

20 25 32<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

16 20 25 32<br />

40 50 63<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

16 20 25 32<br />

40 50 63<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

H series<br />

<strong>WS</strong>S G1<br />

NV63-HW<br />

16 20 25 32<br />

40 50 63<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

0.04 0.04 0.04 0.04<br />

Button<br />

Button<br />

Button<br />

Button<br />

5/2<br />

2.5/1<br />

7.5/4<br />

10/5<br />

5/2<br />

5/2<br />

7.5/4<br />

10/5<br />

5/2<br />

5/2<br />

7.5/4<br />

10/5<br />

10/5<br />

7.5/4<br />

15/8<br />

25/13<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (3P: 2pcs) excluding models of NV63-CW<br />

63<br />

Type NV32-SW<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

4h<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Min.<br />

Max.<br />

NV32-SW<br />

NV63-CW NV63-SW NV63-HW<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Highspeed<br />

type<br />

Rated current sensitivity<br />

0.02s<br />

25 50 100<br />

500<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

Ground-fault current(% of rated current sensitivity)<br />

100% of Rated current<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Remark: (1) refer to 24.<br />

Left-side<br />

mounting<br />

<br />

<br />

<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

<br />

Lead wire<br />

direction<br />

Operating time change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

Ambient temperature (°C)<br />

Rated ambient<br />

40<br />

50<br />

60<br />

■External Accessories<br />

■Internal Wiring Diagram<br />

Enclosure<br />

Accessories<br />

Operating handle<br />

Dustproof<br />

Waterproof<br />

Handle lock device<br />

F<br />

S<br />

V<br />

Type name<br />

F05SW<br />

S05SW<br />

V05SWF<br />

R –<br />

S<br />

I<br />

W<br />

LC<br />

(*1)<br />

HL<br />

NFS-05SW<br />

NFl-05SW<br />

NFW-05SW<br />

LC-05SW<br />

HLF-05SW<br />

HLN-05SW<br />

Reference<br />

page<br />

27<br />

28<br />

–<br />

HL-S HLS-05SW<br />

Note: (*1) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

29<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*1) 32<br />

Small TC-S TCS-05SW3W<br />

Large TC-L TCL-05SW3W<br />

Skeleton TTC TTC-05SW3<br />

Rear BTC BTC-05SW3W<br />

Plug-in PTC PTC-05SW3W<br />

Reference<br />

page<br />

32<br />

IEC 35mm rail<br />

DIN-05SW 32<br />

mounting adapters<br />

30<br />

Line side<br />

Magnetic<br />

device<br />

Leakage<br />

indication button<br />

Test button<br />

Senstivity<br />

selector<br />

<br />

Load side<br />

43


R1<br />

● NV63-CW, NV63-SW, NV63-HW, NV32-SW<br />

Front connection<br />

Insulation barrier<br />

(removable)<br />

M5×0.8 screw<br />

(M6 for 63A)<br />

Applicable<br />

wire size:1.6mm-dia.to 22mm 2<br />

Mounting hole<br />

Sensitivity current<br />

selector<br />

24<br />

Breaker<br />

ø5.5<br />

(6.5mm-diameter for 63A)<br />

Screw terminal<br />

ø8.5<br />

ø4.5<br />

6<br />

111<br />

130<br />

84<br />

50<br />

111<br />

Trip button<br />

22<br />

50<br />

75<br />

Test button<br />

Leakage<br />

indicaton button<br />

45<br />

61<br />

68<br />

12.5 max.<br />

(Conductor thickness<br />

t=5 max.)<br />

25<br />

M4×0.7 taps<br />

or 5mm dia.hole<br />

4<br />

72<br />

Conductor drilling<br />

for direct connection<br />

Drilling plan<br />

90<br />

Rear connection<br />

Mounting panel<br />

t=3.2max<br />

Insulation tube<br />

Breaker<br />

Breaker<br />

6<br />

111<br />

52<br />

8<br />

111<br />

27 min.<br />

M6 screw<br />

50<br />

M4×0.7 screw<br />

for mounting breaker<br />

25<br />

50<br />

ø14<br />

M4×0.7 taps<br />

or 5mm-dia.hole<br />

70<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

68<br />

72<br />

42<br />

Drilling plan<br />

Front-panel cutout<br />

Plug-in<br />

M5×0.8<br />

terminal block mounting screw<br />

80<br />

Plug-in terminal block<br />

Mounting panel<br />

3<br />

50<br />

Breaker (plug-in terminal block)<br />

15.5<br />

5.5<br />

11<br />

83.5<br />

85<br />

180<br />

111<br />

16.5 max.<br />

Center line of<br />

breaker body<br />

54<br />

54 80 54<br />

7<br />

10<br />

21<br />

89<br />

30<br />

M6 screw<br />

ø6.5<br />

25<br />

82<br />

6mm-dia.hole or<br />

M5×0.8 taps<br />

Details of terminal<br />

Conductor drilling cutout<br />

for direct connection<br />

Cutout and drilling plan<br />

44


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV125-CW<br />

NV125-HW<br />

Type NV125-CW<br />

NV125-SW<br />

■Operating Characteristics<br />

<strong>Series</strong> C series S series H series<br />

Group <strong>WS</strong>S G2 <strong>WS</strong>S G2 <strong>WS</strong>S G2<br />

Frame size 125 125<br />

125<br />

Type name NV125-CW NV125-SW NV125-HW<br />

Rated current In (Amp.)<br />

16 20 32 16 20 32<br />

63 80<br />

40 50 63 40 50 63<br />

100 125<br />

80 100 (125) *1 80 100 125<br />

Number of poles 3 3 4 3 4<br />

Rated operational voltage Ue (V AC)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

*1: 3P only<br />

Note: The time-delayed types will be produced when they have the current specifications of 20A or more.<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

0.04 0.04 0.04<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

10/5<br />

10/5<br />

30/15<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

50/25<br />

50/25<br />

100/50<br />

Mounting screw: M4×0.7×55 (3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (3P: 2pcs, 4P: 3pcs)<br />

excluding models of NV125-CW<br />

4h<br />

4h<br />

4h<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-CW 63A100A<br />

NV125-SW 40A100A<br />

NV125-HW 40A100A<br />

(IEC 60947-2)<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-SW 16A~20A<br />

NV125-HW 16A~20A<br />

(IEC 60947-2)<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-CW 125A<br />

NV125-SW 125A<br />

(IEC 60947-2)<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-SW 32A<br />

NV125-HW 32A<br />

(IEC 60947-2)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max. (60A100A)<br />

Max. (40A50A)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

1s<br />

1s<br />

1s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking<br />

time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

Operating time<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

100 of Rated current<br />

■Earth-Leakage Tripping<br />

Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

0.02s<br />

0.01s<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Time-delay trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

100 of Rated current<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

<br />

<br />

Remark: (1) refer to 24.<br />

Instantaneous trip<br />

6070<br />

Operating handle<br />

Right-side<br />

mounting<br />

Lead wire<br />

direction<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

100 of Rated current<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

100 of Rated current<br />

■Temperature Characteristics<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Rated ambient<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Instantaneous trip<br />

25 50 100<br />

500<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

45<br />

■External Accessories<br />

Enclosure<br />

Ground-fault current (% of rated current sensitivity)<br />

Accessories<br />

Operating<br />

handle<br />

Dustproof<br />

Waterproof<br />

Handle lock<br />

device<br />

F<br />

F1SW<br />

S S1SW<br />

V V1SW (*1)<br />

R R1SW<br />

S<br />

I<br />

W<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

Type name<br />

NFS-1SW<br />

NFl-1SW<br />

NFW-1SW/1HW<br />

LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

HLS-1SW<br />

Reference<br />

page<br />

27<br />

28<br />

29<br />

32<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Ml Ml-05SW3 (*4) 32<br />

Small TC-S TCS-1SW3W (*4)<br />

Large TC-L TCL-1SW3W (*4)<br />

Skeleton TTC TTC-1SW3(*4)<br />

Rear BTC BTC-1SW3W (*4)<br />

Plug-in PTC PTC-1SW3W (*4)<br />

IEC 35mm rail<br />

mounting adapters<br />

Electrical<br />

operation device<br />

Notes: (*1) Attach the letter "F" to the end of designation for a fixed type.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) Specify the working voltage.<br />

(*4) The designation depends on the number of poles. Refer to the reference page.<br />

Type name<br />

MDS-NV1SWE (*3)<br />

Reference<br />

page<br />

30<br />

DIN-1SW (*4) 32<br />

30<br />

■Internal Wiring Diagram<br />

Line side<br />

Magnetic<br />

device<br />

Leakage<br />

indication button<br />

Test button<br />

Senstivity<br />

selector<br />

<br />

Load side


● NV125-CW, NV125-SW, NV125-HW<br />

Front connection<br />

Mounting hole<br />

50<br />

CL<br />

Sensitivity current<br />

selector<br />

CL<br />

Insulation barrier<br />

(removable)<br />

Sensitivity current<br />

selector<br />

M8 screw<br />

24<br />

Solderless terminal<br />

for wire size<br />

14~2/0AWG CU/AL<br />

CL<br />

Breaker<br />

CL<br />

130<br />

112<br />

CL<br />

Operating time<br />

selector<br />

(time-delay type)<br />

Leakage<br />

indication button<br />

Operating time<br />

selector<br />

(time-delay type)<br />

Leakage<br />

indication button<br />

84<br />

50<br />

Wire connection<br />

CL<br />

110- 111<br />

Test button<br />

Test button<br />

Trip<br />

button<br />

22<br />

60<br />

90<br />

Trip<br />

button<br />

30<br />

90<br />

120<br />

Neutral pole<br />

45<br />

61<br />

68<br />

4 72<br />

19 max.<br />

ø8.5<br />

8<br />

30<br />

3-pole<br />

30<br />

M4×0.7 taps<br />

or 5mm-dia. hole<br />

4-pole<br />

3-pole<br />

4-pole<br />

90<br />

(Conductor thickness<br />

t=5 max.)<br />

Drilling plan<br />

Conductor drilling<br />

for direct connection<br />

Rear connection<br />

Mounting plate<br />

t=3.2 max.<br />

52<br />

102<br />

Mounting base<br />

Stud rotatable<br />

by 90°<br />

4-pole<br />

3-pole<br />

LC<br />

Breaker<br />

LC<br />

4-pole<br />

3-pole LC<br />

LC<br />

Breaker<br />

LC<br />

Connection<br />

allowance<br />

15<br />

16<br />

112<br />

6<br />

LC<br />

110-111<br />

112<br />

LC<br />

R1<br />

52<br />

30<br />

8.5<br />

68<br />

2.5<br />

15<br />

54.5<br />

2.5<br />

15<br />

M8 bolt<br />

5<br />

60<br />

90<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulation<br />

tube<br />

30<br />

60<br />

3-pole<br />

ø18<br />

30<br />

90<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

4-pole<br />

86<br />

28<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

72<br />

104.5<br />

Drilling plan<br />

Front-panel cutout<br />

Plug-in<br />

4-pole<br />

M5×0.8<br />

Terminal block mounting screw<br />

125<br />

Mounting plate<br />

90<br />

Breaker (plug-in terminal block)<br />

Plug-in terminal block<br />

30<br />

CL<br />

CL<br />

5.5 20<br />

CL<br />

11<br />

98<br />

190<br />

134<br />

16.5 max.<br />

LC<br />

56<br />

12<br />

54<br />

94 56<br />

12.5<br />

Details of terminal<br />

21<br />

89<br />

30<br />

M8 screw<br />

60<br />

95<br />

3-pole<br />

ø8.5<br />

Conductor drilling<br />

for direct connection<br />

30<br />

97<br />

3-pole<br />

60<br />

127<br />

4-pole<br />

6mm-dia. hole<br />

or M5×0.8 taps<br />

Drilling plan<br />

Remark: NV125-CW is available in 3-pole only.<br />

46


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV250-CW<br />

NV250-HW<br />

Type NV250-CW<br />

NV250-SW<br />

<strong>Series</strong> C series S series<br />

Group <strong>WS</strong>S G3 <strong>WS</strong>S G3<br />

Frame size 250 250<br />

Type name NV250-CW NV250-SW<br />

Rated current In (Amp.)<br />

H series<br />

<strong>WS</strong>S G3<br />

250<br />

NV250-HW<br />

Number of poles 3 3 4 3 4<br />

Rated operational voltage Ue (V AC)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

125 150 175<br />

200 225 250<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

0.04 0.04 0.04<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

15/8<br />

18/9<br />

35/18<br />

125 150 175 125 150 175<br />

200 225 250 200 225<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

125 150 175<br />

200 225<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

50/13<br />

50/13<br />

100/25<br />

Mounting screw: M4×0.7×55 (3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (3P: 4pcs, 4P: 6pcs)<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

■Internal Accessories<br />

NV250-CW NV250-RW<br />

NV250-SW MN225-SW<br />

NV250-HW<br />

Max.<br />

Max.total<br />

breaking time<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

100% of Rated current<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Highspeed<br />

type<br />

Rated current sensitivity<br />

25 50 100<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Time-delay type<br />

1s(MAX)<br />

Ground-fault current (% of rated current sensitivity)<br />

■Temperature Characteristics<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

500 25 50 100 5001000<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 5001000<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 5001000<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

<br />

<br />

<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

Remark: (1) refer to 24.<br />

■External Accessories<br />

<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■Internal Wiring Diagram<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Test button<br />

Enclosure<br />

Operating<br />

handle<br />

Dustproof<br />

Waterproof<br />

Handle lock<br />

device<br />

F<br />

F2SW<br />

S S2SW<br />

V V2SW (*1)<br />

R R2SW<br />

S NFS-2SW (*5)<br />

I<br />

W<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

NFl-2SW<br />

NFW-2SW<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

27<br />

28<br />

29<br />

Terminal cover<br />

Mechanical<br />

interlock<br />

Ml<br />

Ml-05SW3(*3) 32<br />

Small TC-S TCS-2SW3W (*3)<br />

Large TC-L TCL-2SW3W (*3)<br />

Skeleton TTC TTC-2SW3 (*3)<br />

Rear BTC BTC-2SW3W (*3)<br />

Plug-in PTC PTC-2SW3W (*3)<br />

Electrical<br />

32 MDS-NV2SWE (*4)<br />

operation device<br />

Notes: (*1) Attach the letter "F" to the end of designation for a fixed type.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) The designation depends on the number of poles. Refer to the reference page.<br />

(*4) Specify the working voltage.<br />

(*5) NV250-HW model cannot be produced.<br />

30<br />

Line side<br />

Magnetic<br />

device<br />

Leakage<br />

indication button<br />

Senstivity<br />

selector<br />

<br />

Load side<br />

47


● NV250-CW, NV250-SW, NV250-HW<br />

Front connection<br />

Mounting button<br />

Trip button<br />

CL<br />

LC<br />

22<br />

70<br />

Insulating barrier<br />

(removable)<br />

Sensitivity<br />

selector<br />

Operating time<br />

selector<br />

(for time-delay<br />

type)<br />

Leakage<br />

indication<br />

button<br />

Test button<br />

CL<br />

35<br />

105<br />

144<br />

100 165<br />

100<br />

Neutral<br />

pole<br />

102<br />

M8 bolt<br />

(Hex-soket)<br />

50<br />

ø8.5<br />

61<br />

68<br />

24<br />

45<br />

ø4.5<br />

30<br />

Solderless terminal<br />

for wire size<br />

125~175A 14~95mm 2<br />

200~250A 70~125mm 2<br />

Wire connection<br />

23 max.<br />

ø8.5<br />

10<br />

LC<br />

LC<br />

35<br />

Breaker<br />

35<br />

CL<br />

M4×0.7 screw<br />

or ø5<br />

126<br />

105 140<br />

4 72<br />

(Bus t max.=7)<br />

3-pole<br />

4-pole<br />

92<br />

Bus drilling for<br />

direct connection<br />

Drilling plan<br />

3-pole<br />

4-pole<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

LC<br />

Breaker<br />

LC<br />

4-pole<br />

3-pole<br />

CL<br />

LC<br />

Breaker<br />

LC<br />

Connection<br />

allowance<br />

22<br />

20<br />

144<br />

8<br />

CL<br />

126<br />

144<br />

CL<br />

R1<br />

52<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15<br />

ø9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

screw<br />

or ø5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

32.5<br />

Plug-in<br />

200<br />

Mounting plate<br />

LC<br />

Plug-in terminal block<br />

14<br />

6<br />

28 144<br />

34.5<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

LC<br />

153<br />

CL<br />

CL<br />

Breaker (Terminal block)<br />

LC<br />

54<br />

58.5 80 58.5<br />

18<br />

86<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

derection only<br />

20<br />

70<br />

ø9<br />

M8 bolt<br />

Insulating barrier<br />

70<br />

107<br />

3-pole<br />

ø7<br />

105<br />

142<br />

4-pole<br />

Drilling plan<br />

Remark: NV250-CW are available in 3-pole only.<br />

48


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV250-SEW NV250-HEW<br />

Type NV250-SEW<br />

<strong>Series</strong><br />

Group<br />

Frame size 250<br />

Type name<br />

Rated current In (Amp.)<br />

S series<br />

<strong>WS</strong>S G3<br />

NV250-SEW<br />

H series<br />

<strong>WS</strong>S G3<br />

250<br />

NV250-HEW<br />

Number of poles 3 4 3 4<br />

Rated operational voltage Ue (V AC)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

125–225<br />

Adjustable<br />

230–400–440 230–400–440<br />

Multi-voltage type Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

30 • 100 • 500<br />

Selectable<br />

0.04 0.04<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

125–225<br />

Adjustable<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

50/13<br />

50/13<br />

100/25<br />

Mounting screw:<br />

M4×0.7×55 (3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (3P: 4pc, 4P: 6pcs)<br />

■Operating Characteristics<br />

4h<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

10s<br />

Pre-alarm<br />

5s<br />

pickup current I P<br />

I rx(0.70-0.75<br />

2s -0.8-0.85-0.9<br />

-0.95-1.0) 10%<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Pre-alarm<br />

operating time TP<br />

L<br />

T = T 20%<br />

P 2<br />

(at 200%)<br />

INST pickup current I I<br />

Inx(416) 15%<br />

Operating handle<br />

Right-side<br />

mounting<br />

■External Accessories<br />

LTD operating time TL<br />

12-60-80-100s 20%<br />

(at 200%)<br />

x100% of Current setting<br />

NV250-SEW NV250-HEW<br />

Note)<br />

Cureent setting Ir Rated current In<br />

125~225A 225A<br />

(Adjustable)<br />

<br />

STD pickup current I s<br />

I rx(2-2.5-3-3.5-4<br />

-5-6-7-8-10) 15%<br />

STD operating time Ts<br />

<br />

0.30.06s<br />

0.20.04s<br />

0.10.03s<br />

0.060.02s<br />

Max.total breaking<br />

time<br />

0.6 0.7 1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

<br />

<br />

Note) Instantaneous tripping<br />

currentx100% of In<br />

<br />

Lead wire<br />

direction<br />

Note: (*1) Parenthesized dimensions represent those for models with PAL, EAL, or TBM.<br />

Flush-mounted models with PAL, EAL, or TBM have an outside view different from<br />

the standard outside view, which will be available upon request.<br />

Remark: (1) refer to 24.<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

■Temperature Characteristics<br />

Derating of Load current (%)<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

25 50 100<br />

130<br />

120<br />

110<br />

100<br />

Highspeed<br />

type<br />

90<br />

80<br />

70<br />

-10<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

500 25 50 100 5001000<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 5001000<br />

Ground-fault current (% of rated current sensitivity)<br />

■Internal Wiring Diagram<br />

Rated ambient<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 5001000<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Enclosure<br />

Accessories<br />

Operating<br />

handle<br />

Dustproof<br />

Waterproof<br />

Handle lock<br />

device<br />

F<br />

F2SW<br />

S S2SW<br />

V V2SW (*1)<br />

R R2SW<br />

S NFS-2SW (*5)<br />

I<br />

W<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

Type name<br />

NFl-2SW<br />

NFW-2SW<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

Reference<br />

page<br />

27<br />

28<br />

29<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*3) 32<br />

Small TC-S TCS-2SW3W (*3)<br />

Large TC-L TCL-2SW3W (*3)<br />

Skeleton TTC TTC-2SW3 (*3)<br />

Rear BTC BTC-2SW3W (*3)<br />

Plug-in PTC PTC-2SW3W (*3)<br />

32<br />

Electrical<br />

MDS-NVE2SWE (*4)<br />

operation device<br />

Reference<br />

page<br />

30<br />

Magnetic<br />

device<br />

Line side<br />

Magnetic<br />

device<br />

Characteristic<br />

setting part<br />

<br />

<br />

<br />

Test button<br />

<br />

Sensitivity<br />

selector<br />

Load side<br />

49<br />

Notes: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) The designation depends on the number of poles. Refer to the reference page.<br />

(*4) Specify the working voltage.<br />

(*5) NV250-HEW model cannot be produced.<br />

Leakage<br />

indication button


● NV250-SEW, NV250-HEW<br />

Front connection<br />

Insulating barrier<br />

(removable)<br />

M8 bolt<br />

(Hex-soket)<br />

24<br />

Note: The setting of selector is available by openning the upper cover.<br />

Mounting hole<br />

Trip<br />

button<br />

Test<br />

cover<br />

22<br />

70<br />

Leakage indicator<br />

button<br />

Current indication LED<br />

OVER<br />

PAL<br />

70%<br />

Sensitivity selector<br />

Operating<br />

time selector<br />

(for time-delay type)<br />

Test button<br />

Operating<br />

characteristics<br />

selector<br />

35<br />

105<br />

144<br />

165 100<br />

100<br />

Neutral<br />

pole<br />

102 (upper cover)<br />

50<br />

ø8.5<br />

45<br />

61<br />

68<br />

30<br />

Solderless terminal<br />

for wire size<br />

125 175A 14 95mm 2<br />

200 225A 70 125mm 2<br />

ø4.5<br />

23max.<br />

Wire connection<br />

ø8.5<br />

10<br />

35<br />

Breaker<br />

M4×0.7 taps<br />

or ø5<br />

35<br />

126<br />

105<br />

3-pole<br />

140<br />

4-pole<br />

4 72<br />

92<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating<br />

tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Connection<br />

allowance<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

52<br />

22<br />

20<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15<br />

ø9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or ø5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

32.5<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal<br />

block<br />

Breaker (Terminal block)<br />

200<br />

14<br />

6<br />

28 144<br />

34.5<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

153<br />

54<br />

80 58.5<br />

58.5<br />

18<br />

86<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

20<br />

Stud attachable in this<br />

derection only<br />

70<br />

ø9<br />

M8 bolt<br />

Insulating<br />

barrier<br />

70<br />

107<br />

3-pole<br />

ø7<br />

Drilling plan<br />

105<br />

142<br />

4-pole<br />

50


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV125-RW<br />

Type NV125-RW<br />

<strong>Series</strong><br />

Group<br />

Frame size 125<br />

Type name<br />

Rated current In (Amp.)<br />

U series<br />

<strong>WS</strong>S G2<br />

NV125-RW<br />

Number of poles 3<br />

Rated operational voltage Ue (V AC)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

AC440V<br />

AC400V<br />

AC230V<br />

16 20 32 40<br />

50 63 80 100<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

0.04<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

125/125<br />

125/125<br />

125/125<br />

■Operating Characteristics<br />

4h<br />

2h<br />

4h<br />

2h<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-RW 16A~32A<br />

(IEC 60947-2)<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-RW 40A~100A<br />

(IEC 60947-2)<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-RW 32A<br />

(IEC 60947-2)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.(60A100A)<br />

Max. (40A50A)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

1s<br />

1s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking<br />

time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

6070<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

100 of Rated current 100 of Rated current 100 of Rated current<br />

■Earth-Leakage Tripping<br />

Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

<br />

<br />

<br />

<br />

Operating handle<br />

Right-side<br />

mounting<br />

Lead wire<br />

direction<br />

■Temperature Characteristics<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

Rated ambient<br />

100<br />

90<br />

80<br />

–10 0 10 20 30 40 50<br />

Ambient temperature (°C)<br />

60<br />

25 50 100<br />

500<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

Ground-fault current (% of rated current sensitivity)<br />

Remark: (1) refer to 24.<br />

■External Accessories<br />

■Internal Wiring Diagram<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Test button<br />

Enclosure<br />

Operating handle<br />

Dustproof<br />

Waterproof<br />

Mechanical interlock<br />

F F1UW<br />

27<br />

S<br />

V<br />

S1UW<br />

V1UW<br />

28<br />

R R1UW<br />

29<br />

S –<br />

I –<br />

–<br />

W –<br />

MI<br />

MI-05SW3 (*1)<br />

32<br />

Terminal cover<br />

Small<br />

Large<br />

Skeleton<br />

Rear<br />

Plug-in<br />

Handle lock<br />

device<br />

TC-S<br />

TC-L<br />

TTC<br />

BTC<br />

PTC<br />

LC<br />

(*3)<br />

HL<br />

TCS-1SW3W (*1)<br />

TCL-1SW3W (*1)<br />

TTC-1SW3 (*1)<br />

BTC-1SW3W (*1)<br />

PTC-1SW3W (*1)<br />

LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

30<br />

32<br />

Line side<br />

Magnetic<br />

device<br />

Senstivity<br />

selector<br />

<br />

Load side<br />

Electrical operation device<br />

(*2)<br />

30<br />

HL-S<br />

HLS-1SW<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) An order should be placed at the same time as an order of circuit breaker main body.<br />

(*3) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

Leakage<br />

indication button<br />

51


● NV125-RW<br />

Front connection<br />

191<br />

61<br />

130<br />

Mounting hole<br />

173<br />

CL<br />

CL<br />

Sensitivity current<br />

selector<br />

Operating time<br />

selector<br />

(time-delay type)<br />

Leakage<br />

indication button<br />

Test button<br />

84<br />

M8 screw<br />

50<br />

24<br />

ø8.5<br />

8<br />

CL<br />

LC<br />

Breaker<br />

171-172<br />

Trip<br />

button<br />

22<br />

60<br />

90<br />

4<br />

45<br />

61<br />

68<br />

72<br />

19 max.<br />

(Conductor thickness t=5 max.)<br />

Conductor drilling for direct connection<br />

30<br />

M4×7 taps or<br />

5mm-dia. hole<br />

90<br />

Drilling plan<br />

Rear connection<br />

Mounting plate<br />

t=3.2 max.<br />

102<br />

52<br />

Stud rotatble<br />

by 90°<br />

CL<br />

Breaker<br />

LC<br />

Breaker<br />

CL<br />

Mounting base<br />

Connection<br />

15 allowance<br />

16<br />

173<br />

CL<br />

6<br />

CL<br />

171-172<br />

173<br />

LC<br />

1<br />

4.5<br />

52<br />

8.5<br />

68<br />

72<br />

2.5<br />

15<br />

54.5<br />

104.5<br />

2.5<br />

15<br />

M8 bolt<br />

5 60<br />

M4×0.7<br />

60<br />

breaker<br />

mounting screw<br />

Insulation<br />

tube<br />

30<br />

Drilling plan<br />

ø18<br />

M4×7 taps or<br />

5mm-dia. hole<br />

86<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Front-panel cutout<br />

Plug-in<br />

Mounting plate<br />

M5×0.8<br />

Terminal block mounting screw<br />

Breaker<br />

(plug-in terminal block)<br />

Plug-in terminal<br />

block<br />

CL<br />

LC<br />

LC<br />

11<br />

159<br />

251<br />

LC<br />

195<br />

5.5<br />

20<br />

16.5 max.<br />

12<br />

LC<br />

115<br />

56 155 56<br />

21<br />

89<br />

30<br />

M8 screw<br />

60<br />

95<br />

12.5<br />

Details of terminal<br />

ø8.5<br />

Conductor drilling<br />

for direct connection<br />

30<br />

97<br />

6mm-dia. hole<br />

or M5×0.8 taps<br />

Drilling plan<br />

52


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV250-RW<br />

Type NV250-RW<br />

<strong>Series</strong><br />

Group<br />

Frame size 250<br />

Type name<br />

Rated current In (Amp.)<br />

R series<br />

<strong>WS</strong>S G3<br />

NV250-RW<br />

Number of poles 3<br />

Rated operational voltage Ue (V AC)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

AC440V<br />

AC400V<br />

AC230V<br />

125 150 175<br />

200 225<br />

230–400–440<br />

Multi-voltage type<br />

30 • 100 • 500<br />

Selectable<br />

0.04<br />

100 • 300 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

0.1 • 0.5 • 1.0<br />

Button<br />

125/125<br />

125/125<br />

125/125<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

■Internal Accessories<br />

NV250-RW<br />

Max.<br />

Max.total<br />

breaking time<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

100% of Rated current<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Highspeed<br />

type<br />

Rated current sensitivity<br />

25 50 100<br />

Time-delay type<br />

0.45s(MAX)<br />

Inertial<br />

nonoperating time<br />

500 25 50 100 5001000<br />

Time-delay type<br />

1s(MAX)<br />

Inertial<br />

nonoperating time<br />

25 50 100 5001000<br />

Ground-fault current (% of rated current sensitivity)<br />

■Ambient Compensating Curve<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 5001000<br />

Left-side<br />

mounting<br />

<br />

NV250-RW<br />

Operating handle<br />

Right-side<br />

mounting<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

Remark: (1) refer to 24.<br />

■External Accessories<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■Internal Wiring Diagram<br />

Enclosure<br />

Accessories<br />

Operating handle<br />

Dustproof<br />

Waterproof<br />

Handle lock device<br />

Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

F F2UW<br />

Mechanical<br />

27<br />

S S2SW<br />

interlock<br />

MI MI-05SW3 (*1)<br />

V V2UW<br />

28<br />

Small TC-S TCS-2SW3W (*1)<br />

R R2UW<br />

29<br />

Large TC-L TCL-2SW3W (*1)<br />

S –<br />

Skeleton TTC TTC-2SW3 (*1)<br />

I – –<br />

Rear BTC BTC-2SW3W (*1)<br />

W –<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

32<br />

Terminal cover<br />

Plug-in PTC PTC-2SW3W (*1)<br />

Electrical<br />

operation device<br />

(*3)<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) An order should be placed at the same time as an order of circuit breaker main body.<br />

Reference<br />

page<br />

34<br />

30<br />

Line side<br />

Magnetic<br />

device<br />

Leakage<br />

indication button<br />

Test button<br />

Senstivity<br />

selector<br />

<br />

Load side<br />

53


● NV250-RW<br />

Front connection<br />

100 240<br />

100<br />

Mounting hole<br />

165 75<br />

219<br />

Trip<br />

Button<br />

CL<br />

CL<br />

22<br />

70<br />

105<br />

Insulating barrier<br />

(removable)<br />

Sensitivity selector<br />

Operating time selector<br />

(for time-delay type)<br />

Leakage indication<br />

button<br />

Test button<br />

165 75<br />

M8 bolt<br />

(Hex-socket)<br />

28<br />

102<br />

50<br />

ø8.5<br />

4<br />

45<br />

61<br />

68<br />

72<br />

92<br />

24<br />

ø4.5<br />

Solderless terminal<br />

for wire size<br />

125~175A 14~95mm 2<br />

200~225A 70~125mm 2<br />

Wire connection<br />

23 max<br />

ø8.5<br />

10<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

LC<br />

LC<br />

35<br />

Drilling plan<br />

Breaker<br />

201<br />

M4×0.7 screw<br />

or ø5<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating<br />

tube<br />

Stud can be<br />

rotated 90°<br />

CL<br />

Breaker<br />

CL<br />

Breaker<br />

CL<br />

73<br />

108<br />

Connection<br />

allowance<br />

22<br />

20<br />

219<br />

LC<br />

8<br />

CL<br />

201<br />

219<br />

LC<br />

R1<br />

11.5<br />

52<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15<br />

ø9<br />

M8 bolt<br />

6<br />

70<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

ø24<br />

M4×0.7<br />

screw<br />

or ø5<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Drilling plan<br />

Front-plate cutout<br />

Plug-in<br />

275<br />

Mounting plate<br />

CL<br />

14<br />

Plug-in terminal<br />

block<br />

34.5<br />

219<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

LC<br />

CL<br />

CL<br />

Breaker (Terminal block)<br />

129<br />

6<br />

28<br />

58.5<br />

153<br />

155 58.5<br />

18<br />

86 32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

derection only<br />

20<br />

70<br />

ø9<br />

M8 bolt<br />

Insulating<br />

barrier<br />

70<br />

107<br />

Drilling plan<br />

ø7<br />

54


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF50-SWU<br />

<strong>Series</strong><br />

S series<br />

Group<br />

<strong>WS</strong>S G1<br />

Frame size 50<br />

Type name<br />

NF50-SWU<br />

Rated current In (Amp.)<br />

5 10 15 20<br />

30 40 50<br />

Type NF50-SWU<br />

Number of poles 2<br />

3<br />

Rated braking<br />

cpacity (kA)<br />

UL489<br />

IEC60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Standard attached parts<br />

Rated voltage (AC V)<br />

AC<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

500V<br />

440V<br />

400V<br />

230V<br />

240<br />

10<br />

600<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

15/8<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs),<br />

Insulation board: (1pc)<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Operating Characteristics<br />

(UL489)<br />

NF50-SWU<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

1s<br />

0.5s<br />

Min.<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40<br />

100% of Rated current<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Left-side<br />

mounting<br />

2-pole<br />

3-pole<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

<br />

<br />

Lead wire<br />

direction<br />

Operating time change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10 0 10 20 30 40 50 60<br />

Rated ambient<br />

Ambient temperature (°C)<br />

■External Accessories<br />

Accessories Type name<br />

Accessories<br />

Type name<br />

F05SWU2P<br />

F<br />

F05SWU Mechanical interlock Ml Ml-05SWU<br />

Operating handle<br />

S S05SWU<br />

V V05SWUF (*1) Terminal<br />

Large TC-L TCL-05SWU2<br />

cover<br />

TCL-05SWU3<br />

Handle lock device HL HLF-05SWU<br />

Note: (*1) Adjustable types can be produced upon request.<br />

55


1<br />

● NF50-SWU<br />

Front connection<br />

CL<br />

Mounting hole<br />

LC<br />

Insulation barrier<br />

(removable)<br />

M5×0.8 screw<br />

(M6 for 63A)<br />

24<br />

ø5.5<br />

50<br />

6<br />

12.5 max.<br />

(Conductor thickness<br />

t5 max.)<br />

CL<br />

111<br />

150<br />

84<br />

50<br />

ø8.5<br />

Conductor drilling<br />

for direct connection<br />

Trip button<br />

ø4.5<br />

50<br />

61<br />

45<br />

Applicable<br />

wire size: 1.6mm-dia. to 22mm 2<br />

25 22<br />

68<br />

50<br />

2-pole<br />

50<br />

75<br />

3-pole<br />

4<br />

72<br />

90<br />

Screw terminal<br />

M40.7 taps or 5mm dia.hole<br />

LC<br />

LC<br />

Breaker<br />

LC<br />

LC<br />

Breaker<br />

130<br />

98.5<br />

30<br />

LC<br />

111<br />

LC<br />

52<br />

(Insulation plate)<br />

(Line)<br />

25<br />

2-pole 3-pole 2-pole 3-pole<br />

50<br />

70<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

CAUTION:<br />

When mounted in steel or cast box<br />

cover must be insulated as shown.<br />

30mm air gap to cover or 0.8mm<br />

fibre insulating plate extending<br />

12.7mm out from each side of breaker.<br />

Drilling plan<br />

Front-panel cutout<br />

56


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF100-CWU<br />

NF100-SWU<br />

<strong>Series</strong><br />

C series<br />

Group<br />

<strong>WS</strong>S G2<br />

Frame size 100<br />

Type name<br />

NF100-CWU<br />

S series<br />

<strong>WS</strong>S G2<br />

100<br />

NF100-SWU<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

50 60<br />

75 100<br />

15 20 30 40<br />

50 60<br />

75 100<br />

Type NF100-SWU<br />

Number of poles 2 3 2 3<br />

Rated voltage (AC V)<br />

240<br />

480Y/277<br />

UL489<br />

480Y/277V<br />

–<br />

22<br />

AC<br />

240V<br />

10<br />

35<br />

Rated insulation voltage Ui (V) 600<br />

690<br />

690V<br />

–<br />

8/4<br />

IEC60947-2<br />

500V<br />

7.5/4<br />

18/9<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

AC<br />

440V<br />

400V<br />

10/5<br />

10/5<br />

25/13<br />

30/15<br />

230V<br />

30/15<br />

50/25<br />

DC<br />

250V<br />

7.5/4<br />

15/8<br />

Rated short-circuit braking<br />

capacities (kA)<br />

Standard attached parts<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs),<br />

Insulation board: (1pc)<br />

■Operating Characteristics<br />

4h<br />

4h<br />

2h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NF100-CWU 50A100A<br />

NF100-SWU 40A100A<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Type<br />

NF100-SWU 15A30A<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max. (60A100A)<br />

Max. (40A,50A)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

1s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.1s<br />

0.05s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40 50 6070<br />

100 of Rated current<br />

100 of rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

2-pole<br />

3-pole<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

<br />

<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

80<br />

–10<br />

0 10 20 30 40 50 60<br />

Ambint temperature (°C)<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

Type name<br />

Accessories<br />

Type name<br />

F<br />

F1SWU2P<br />

F1SWU Mechanical interlock Ml Ml-05SWU<br />

S S1SWU<br />

V V1SWU (*1) Terminal<br />

Large TC-L TCL-1SWU2<br />

cover<br />

TCL-1SWU3<br />

HL HLF-1SWU<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

57


● NF100-CWU, NF100-SWU<br />

Front connection<br />

(Standard)<br />

150 50<br />

112<br />

CL<br />

CL<br />

Mounting<br />

hole<br />

CL<br />

LC<br />

Insulation barrier<br />

(removable)<br />

84<br />

M8 screw<br />

50<br />

24<br />

(Conductor thickness<br />

t=5 max)<br />

Conductor drilling<br />

for direct connection<br />

ø8.5<br />

19 max.<br />

8<br />

Trip<br />

button<br />

45<br />

30<br />

60<br />

22<br />

60<br />

90<br />

61<br />

68<br />

4 72<br />

90<br />

2-pole<br />

3-pole<br />

Front connection (Solderless terminal)<br />

(Option)<br />

LC<br />

CL<br />

Solderless terminal<br />

5.03<br />

LC<br />

LC<br />

Hexagon socket set screw<br />

wire size<br />

14~2/0AWG CU/AL<br />

2-pole<br />

3-pole<br />

2-pole<br />

3-pole<br />

130<br />

CL<br />

LC<br />

Breaker<br />

CL<br />

LC<br />

Breaker<br />

98.5<br />

30<br />

CL<br />

CL<br />

110-111<br />

CL<br />

LC<br />

R1<br />

52<br />

(Insulation plate)<br />

(Line)<br />

2-pole<br />

30<br />

3-pole<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

57<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

86<br />

CAUTION:<br />

When mounted in steel or cast box<br />

cover must be insulated as shown.<br />

30mm air gap to cover or<br />

0.8mm fibre insulating plate<br />

extending 12.7mm out from<br />

each side of breaker.<br />

Drilling plan<br />

Front-panel cutout<br />

58


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF225-CWU<br />

<strong>Series</strong><br />

Group<br />

Frame size<br />

Type name<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

C series<br />

<strong>WS</strong>S G3<br />

225<br />

NF225-CWU<br />

125 150 175<br />

200 225<br />

Type NF225-CWU<br />

Number of poles 3<br />

Rated short-circuit braking<br />

capacities (kA)<br />

UL489<br />

IEC60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Standard attached parts<br />

Rated voltage (AC V)<br />

AC<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

500V<br />

440V<br />

400V<br />

230V<br />

250V<br />

240<br />

35<br />

600<br />

10/5<br />

15/8<br />

18/9<br />

35/18<br />

10/5 (*1)<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (4pcs),<br />

Terminal cover: (1 set), (*2)<br />

Insulation board: (1pc)<br />

Notes: (*1) Use either two poles. When wired as shown at the bottom of page 13, the models can<br />

be used for up to 400 V DC.<br />

(*2) The standard configuration contains a protection cover and adopts the IP20 (finger<br />

protection) structure.<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

NF225-CWU<br />

6min<br />

4min<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

Min.<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.35<br />

Time-delay trip<br />

Instantaneous trip<br />

2 3 4 5 6 7 10 15 20 30 40<br />

100 of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

<br />

<br />

<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

80<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

40<br />

50<br />

60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

<br />

<br />

<br />

<br />

Type name<br />

<br />

<br />

<br />

<br />

Accessories<br />

Mechanical interlock<br />

Terminal<br />

cover<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

<br />

Type name<br />

<br />

<br />

59


● NF225-CWU<br />

Front connection<br />

Mounting hole<br />

Trip button<br />

LC<br />

LC<br />

Insulating barrier<br />

144<br />

100 165<br />

100<br />

102<br />

M8 bolt<br />

(Hex-soket)<br />

50<br />

130<br />

100<br />

30<br />

ø8.5<br />

24<br />

ø4.5<br />

22<br />

70<br />

105<br />

45<br />

61<br />

68<br />

4 72<br />

92<br />

CL<br />

Breaker<br />

LC<br />

Breaker<br />

CL<br />

126<br />

CL<br />

R1<br />

52<br />

ø8.5<br />

10<br />

(Insulating plate)<br />

(Line side)<br />

35<br />

M4×0.7 screw<br />

or ø5<br />

100<br />

Bus t max.=7<br />

22 max.<br />

Bus drilling for<br />

direct connection<br />

CAUTION:<br />

When mounted in steel or cast box cover<br />

must be insulated as shown.<br />

30mm air gap to cover or t0.8 fibre<br />

insulating plate extending 12.7mm out<br />

from each side of breaker.<br />

Drilling plan<br />

Front cover cutout<br />

1mm clearance on<br />

each side of handle<br />

60


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF-SFW<br />

NF-SJW<br />

NF-HJW<br />

Type NF-SFW<br />

■Operating Characteristics<br />

<strong>Series</strong> S series H series<br />

Group <strong>WS</strong>S G4 <strong>WS</strong>S G4 <strong>WS</strong>S G4<br />

Frame size 150 250 250<br />

Type name NF-SFW NF-SJW NF-HJW<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

Rated short-circuit braking<br />

capacities (kA)<br />

15 20 30 40<br />

50 60 70 80<br />

90 100 110<br />

125 150<br />

(125) (150) 175<br />

200 225 250<br />

125 150 175<br />

200 225 250<br />

Number of poles 3 3 3<br />

Rated voltage (AC V)<br />

600Y/347 600Y/347 600Y/347<br />

UL489<br />

600Y/347V<br />

14<br />

14<br />

18<br />

AC<br />

480V<br />

35<br />

35<br />

50<br />

240V<br />

65<br />

65<br />

100<br />

Rated insulation voltage Ui (V)<br />

690<br />

690<br />

690<br />

690V<br />

8/8<br />

8/8<br />

15/15<br />

IEC60947-2<br />

500V<br />

30/30<br />

30/30<br />

36/36<br />

JIS C 8201-2<br />

440V<br />

36/36<br />

36/36<br />

50/50<br />

AC<br />

(Icu/Ics)<br />

400V<br />

36/36<br />

36/36<br />

50/50<br />

230V<br />

85/85<br />

85/85<br />

100/100<br />

DC<br />

250V (*1) 20/20<br />

20/20<br />

20/20<br />

Mounting screw: M4×0.7×73 (4pcs)<br />

Standard attached parts<br />

Insulation barrier: (4pcs),<br />

Insulation board: (1pc)<br />

Note: (*1) Use either two poles. When wired as shown at the bottom of page 13, the models can be used for up to 500 V DC.<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Operating Characteristics<br />

(UL489)<br />

NF-SFW<br />

15A40A<br />

Max.(40A)<br />

Max.(15A30A)<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Operating Characteristics<br />

(UL489)<br />

NF-SFW<br />

50A150A<br />

Max.(60A150A)<br />

Max.(50A)<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Operating Characteristics<br />

(UL489)<br />

NF-SJW/HJW<br />

125A250A<br />

Instantaneous trip<br />

adjustment range<br />

Position AC<br />

of notch x In (%)<br />

4 40080<br />

6 600<br />

8 800<br />

10 1000200<br />

2s<br />

2s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Max. total<br />

breaking<br />

time<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

(60A150A)<br />

(50A)<br />

Max. total<br />

breaking<br />

time<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Adjustable range<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

0.01s<br />

1<br />

1.35<br />

Time-delay trip<br />

2 3<br />

4<br />

Instantaneous trip<br />

5 6 7 10 15 20 30<br />

40<br />

0.02s<br />

Time-delay trip<br />

0.01s<br />

1 1.35 2 3<br />

4<br />

Instantaneous trip<br />

5 6 7 10 15 20 30<br />

40<br />

×100% of Rated current ×100% of Rated current ×100% of Rated current<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

<br />

mounting<br />

<br />

Lead wire<br />

direction<br />

■Ambient Compensating Curve<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

Rated ambient<br />

■External Accessories<br />

Accessories<br />

Operating<br />

handle<br />

Handle<br />

lock device<br />

F<br />

S<br />

V<br />

HL<br />

Type name<br />

F2GSWU<br />

S2GSWU<br />

V2GSWU(*1)<br />

HLF-2GSWU<br />

Terminal<br />

cover<br />

Accessories<br />

Mechanical interlock<br />

Ml<br />

Type name<br />

Ml-05SWU<br />

Large TC-L TCL-2GSWU3<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

● NF-SFW, NF-SJW, NF-HJW<br />

Front connection<br />

(Standard)<br />

Front connection (Solderless terminal)<br />

(Option)<br />

Mounting hole<br />

Insulating barrier<br />

(removable) Hex.socket head 24<br />

Mounting hole LC<br />

CAUTION:<br />

Hexagon socket set screw<br />

M8 bolt<br />

LC Insulating barriers must be used<br />

6.1<br />

with uninsulated bus bars or<br />

climp on terminals.<br />

50<br />

LC<br />

144<br />

185<br />

133<br />

112<br />

50<br />

LC<br />

Trip button<br />

22<br />

35<br />

70<br />

105<br />

144<br />

185<br />

50<br />

133<br />

112<br />

ø8.5 50<br />

4<br />

63<br />

79<br />

83<br />

86<br />

90<br />

110<br />

22<br />

ø4.5<br />

10<br />

24 max.<br />

ø8.5<br />

Conductor thickness t=7max.)<br />

4-FRONT<br />

Bus bar drilling for<br />

direct connection<br />

Trip button<br />

LC<br />

22<br />

35<br />

70<br />

105<br />

LC<br />

Breaker<br />

126<br />

ø8.5<br />

4<br />

LC<br />

79<br />

83<br />

86<br />

63<br />

90<br />

110<br />

LC<br />

ø4.5<br />

Breaker<br />

R1<br />

52<br />

Wire size<br />

No.14AWG350MCM CU/AL<br />

(2.5~185mm2)<br />

3-FRONT<br />

CAUTION:<br />

When mounted in steel or cast box cover<br />

must be insulated as shown.<br />

30mm air gap to cover or extending 12.7mm<br />

out fromeach side of breaker.<br />

130<br />

95<br />

61<br />

35 M4×0.7 taps or<br />

5mm-dia. hole<br />

Drilling plan<br />

100<br />

Front-panel cutout<br />

1.0mm clearance<br />

on each side of<br />

the handle frame.<br />

5-RIGHT<br />

30<br />

Insulation plate<br />

(Line<br />

Outline and dimensions (mm (inch))<br />

Type NF-SFW,NF-SJW,NF-HJW


7. Ordering Information<br />

Molded-Case Circuit Breakers<br />

Earth-Leakage Circuit Breakers<br />

Type name<br />

NF250-SW<br />

C<br />

S<br />

NF<br />

H<br />

U<br />

MB<br />

Economy type<br />

Standard type<br />

High-performance type<br />

Ultra current-limiting type<br />

Motor braker<br />

Type name<br />

NV250-SW<br />

NV<br />

C<br />

S<br />

H<br />

U<br />

Economy type<br />

Standard type<br />

High-performance type<br />

Ultra current-limiting type<br />

Number of poles<br />

Number of poles<br />

2P<br />

NV<br />

1ø2W<br />

3P<br />

NF<br />

MB<br />

2P, 3P<br />

3P<br />

3P<br />

3P<br />

NV<br />

1ø2W<br />

1ø3W<br />

3ø3W<br />

Rated current<br />

200A<br />

Even for adjustable rated current<br />

models, the working current should be<br />

specified.<br />

Rated current<br />

200A<br />

4P<br />

NV<br />

3ø4W<br />

Even for adjustable rated current<br />

models, the working current should be<br />

specified.<br />

Rated voltage<br />

Secify DC voltage when for use in<br />

DC circuit<br />

Rated voltage<br />

AC230-400-440V<br />

AC230-400-440V<br />

<br />

Specify the applicable marine<br />

standards<br />

∗ “CE” is standard.<br />

Rated sensitivity<br />

current<br />

100 • 300 • 500mA<br />

30 • 100 • 500mA<br />

100 • 300 • 500mA<br />

Connection<br />

method<br />

B<br />

F<br />

SL<br />

B<br />

PM<br />

Front connection<br />

Solderless (box) terminal<br />

Rear connection<br />

Pulg-in<br />

Connection<br />

method<br />

B<br />

F<br />

SL<br />

B<br />

PM<br />

Front connection<br />

Solderless (box) terminal<br />

Rear connection<br />

Pulg-in<br />

Internal<br />

accessories<br />

AL, SHT (AC110V)<br />

External<br />

accessories<br />

Quantity<br />

10<br />

AL<br />

AX<br />

SHT<br />

UVT<br />

PAL<br />

SLT<br />

INT<br />

MD<br />

F • S • V<br />

S • I • W<br />

MI<br />

TC<br />

LC • HL<br />

HL-S<br />

CH<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

(Specify rated coil voltage.)<br />

Under voltage trip<br />

(Specify rated coil voltage.)<br />

Pre-alarm module<br />

Lead-wire terminal block<br />

Internal terminal type<br />

Electrical operation device<br />

Operating handle<br />

Enclosure box<br />

Mechanical interlock<br />

Terminal cover<br />

(TC-L, TC-S, TTC, BTC)<br />

Handle lock device<br />

Card holder<br />

Type of residual<br />

carrent protection<br />

Internal<br />

accessories<br />

AX, SLT, TBM<br />

External<br />

accessories<br />

Quantity<br />

10<br />

Blank<br />

Specify<br />

AL<br />

AX<br />

UVT<br />

MG<br />

EAL<br />

TBM<br />

PAL<br />

SLT<br />

MD<br />

F • S • V<br />

S • I • W<br />

MI<br />

TC<br />

High-speed type<br />

Time-delay type<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

Insulation switch<br />

Earth-leakage circuit alarm switch<br />

Test button module<br />

Pre-alarm module<br />

Lead-wire terminal block<br />

Electrical operation device<br />

Operating handle<br />

Enclosure box<br />

Mechanical interlock<br />

Terminal cover<br />

(TC-L, TC-S, TTC, BTC)<br />

LC • HL<br />

HL-S<br />

Handle lock device<br />

CH<br />

Card holder<br />

62


Service Network<br />

Country / Region Company Address Telephone<br />

Australia<br />

Belgium<br />

Chile<br />

Mitsubishi Electric Australia Pty. Ltd.<br />

Emac S.A.<br />

RHONA S.A.<br />

348 Victoria Road, Rydalmere, N.S.W. 2116, Australia<br />

Industrialaan 1, B-1702 Groot-Bijgaarden, Belgium.<br />

Vte. Agua Santa 4211 Casilla 30-D (P.O. Box)<br />

Viña Del Mar. Chile<br />

Building of Innovation Center, Room No. 406A,<br />

612-9684, 7586<br />

32-(0)2-4810211<br />

(32)-611896<br />

SHANGHAI SETSUYO TRADING CO.,LTD.<br />

680 Guiping Road Shanghai, P.R.China<br />

021-6485-6611<br />

China<br />

RYODEN INTERNATIONAL LTD.<br />

(Shanghai) 3F, Block 5, 103<br />

Cao Bao Road, Shanghai, China<br />

021-6475-3228<br />

Colombia<br />

Denmark<br />

Proelectrico Representaciones S.A.<br />

Louis Poulsen CO. A/S<br />

Cra 53 No 29C-73 U.I.C.- Medellin.<br />

COLOMBIA.<br />

Geminivej 32, DK-2670 Greve, Denmark.<br />

9 Rostoum Street Garden City, APT. 5,<br />

574-235-00-28<br />

45-(0)43-95-95-95<br />

Egypt<br />

CAIRO ELECTRICAL GROUP<br />

P.O. BOX: 165-11516,<br />

Cairo-Egypt.<br />

20-2-7961337<br />

Germany<br />

Greece<br />

Hong Kong<br />

Mitsubishi Electric Europe B.V. German Branch.<br />

Drepanias Antonios S.A.<br />

Ryoden international Ltd.<br />

Gothaer Strasse 8, 40880 Ratingen, Germany.<br />

52, Arkadias<br />

STR.GR 121 32. Peristeri Athens Greece.<br />

10/F Manulife Tower 169 Electric Road North<br />

Point. Hong Kong.<br />

JL Muara Karang Selatan Blok A/Utara No.1<br />

49-(0)2102-4860<br />

30(1)57 81 599 699<br />

28878870<br />

Indonesia P.T.SAHABAT INDONESIA.<br />

kav. NO.11 P.O. Box 5045/Jakarta/11050.<br />

Jakarta Indonesia.<br />

021-6621780<br />

Ireland<br />

Italy<br />

Mitsubishi Electric Europe B.V. Irish Branch.<br />

Mitsubishi Electric Europe B.V. Italy<br />

Westgate Business Park, Ballymount, Dublin 24, Ireland.<br />

C.D. Colleoni-P. Perseo lng. 2, Via Paracelso 12<br />

1-20041 Agrate Brianza (M1)<br />

353-(0)1-4505007<br />

39-(0)39 60 531<br />

Korea<br />

Kuwait<br />

Lao PDR<br />

Lebanon<br />

Myanmer<br />

Nepal<br />

Netherlands<br />

New Zealand<br />

Norway<br />

Pakistan<br />

Peru<br />

Philippines<br />

Poland<br />

Saudi Arabia<br />

Singapore<br />

Slovenia<br />

South Africa<br />

Spain<br />

Sweden<br />

Switzerland<br />

Taiwan<br />

Thailand<br />

Turkey<br />

U.K.<br />

Uruguay<br />

Venezuela<br />

Vietnam<br />

HAN NEUNG TECHNO Co., Ltd.<br />

SALEM M AL-NISF ELECTRICAL CO.W.L.L.<br />

SOCIETE LAO IMPORT-EXPORT<br />

COMPTOIR D'ELECTRICITE<br />

GENERALE INTERNATIONAL<br />

PEACE MYANMAR ELECTRIC CO., LTD.<br />

Watt & Volt House Co., Ltd.<br />

Imtech Marine & Industry<br />

Melco Sales (N.Z.) Ltd.<br />

SCANELEC<br />

Prince Electric Co.<br />

I.T.E.<br />

EDISON ELECTRIC INTEGRATED, INC.<br />

MPL Technology Sp zo.o.<br />

CENTER OF ELECTRICAL GOODS<br />

MITSUBISHI ELECTRIC ASIA PTE LTD.<br />

INEA d.o.o.<br />

M.S.A.MANUFACTURING (PTY) LTD.<br />

Mitsubishi Electric Europe B.V.<br />

Spanish Branch.<br />

Euro Energy Components AB<br />

Trielec A G<br />

Setsuyo Enterprise Co., Ltd.<br />

UNITED TRADING & IMPORT CO., LTD.<br />

HEDEF DIS Tic. ve Musavirlik LTD. STI<br />

Mitsubishi Electric Europe B.V.<br />

UK-Branch.<br />

Fierro Vignoli S.A.<br />

ADESCO C.A.<br />

Sa Giang Techno Co., Ltd.<br />

2 Fl. Dong Seo Game Channel Bldg ., 1F 660-11<br />

Deungchon-Dong, Kanguseo-Ku, Seoul, 157-030 Korea<br />

P.O. Box 4784. Safat. 13048 Kuwait.<br />

43-47 Lane Xang Road P.O. BOX 2789 VT<br />

Vientiane Lao PDR.<br />

Cebaco Center-Block A. Autostrade Dora,<br />

P.O. BOX: 90-1314 Beirut-Lebanon.<br />

No. 216, Bo Aung Gyaw Street,<br />

Botataung 11161, Yangon, Myanmar.<br />

KHA 2-65, Volt House Dilli Bazar Post Box: 2108,<br />

kathmandu, Nepal<br />

Postbox 5054, NL-3008 AB-Rotterdam, Netherlands.<br />

1 Parliament Street Lower Hutt. New Zealand.<br />

Leirvikasen 43B, N5020 Bergen, Norway.<br />

16 Brandreth Road Lahore 54000. Pakistan.<br />

Ingenieros s.a. Paseo de la Republica 3573<br />

Lima 27. Peru.<br />

24th Fl. Galleria Corporate Center Edsa Cr, Ortigas Ave.<br />

Quezon City, Metro Manila. Philippines.<br />

ul. Wroclawska 53, PL-30011 Kraków, Poland.<br />

Al-Nabhaniya Street-4th Crossing,<br />

Al-Hassa Road, P.O. BOX: 15955, Riyadh 11454,<br />

Saudi Arabia.<br />

307 Alexandra Road #05-01/02 Mitsubishi<br />

Electric Building Singapore 159943<br />

Ljubljanska 80, SI-61230 Domzale, Slovenia.<br />

Bramley 2018, Johannesburg, South Africa.<br />

Polingono Industrial "Can Magi", Calle Joan<br />

Buscalla 2-4, Apartado de Correos 420,08190<br />

Sant Cugat del Valles, Barcelona, Spain.<br />

Box 103 48 S-434 24 Kungsbcka, Sweden.<br />

Mühlentalstrasse 136, 8201 Schaffhausen,<br />

Switzerland<br />

5F, NO. 105 Wu-Kung 3rd rd., Wu-Ku Hsiang,<br />

Taipei Hsien Taiwan<br />

77/12 Bumrungmuang Road, Klong Mahanak,<br />

Pomprab Bangkok 10100.<br />

Barbaros Bulvari Gaziumurpasa sok. 9/4,<br />

TR-Balmumcu-Istanbul, Turkey.<br />

Travellers Lane, Hatfield, Herts, AL10 8xB, U.K.<br />

AV. URUGUAY 1274, Montevideo. Uruguay.<br />

Lle 8, Calpon Elinsu,<br />

La Urbina-EDO, Miranda P.O.<br />

BOX 78034 Caracas 1074A., Venezuela<br />

207/4 Nguyen Van Thu St., Dist 1, Ho Chi Minh City, Vietnam<br />

017-255-0174<br />

965-484-5660<br />

21-215043, 21-215110<br />

961-1-240430<br />

951-295426<br />

977-1-411330<br />

31-(0)10 487 19 11<br />

644-569-7350<br />

47-55-506000<br />

042-7654342<br />

(1) 221-2710<br />

02-643-8691<br />

48-(0)12 632 28 85<br />

966-1-4770149<br />

65-473-2308<br />

386-(0)17 21 80 00<br />

27-11-444-8080<br />

34-93-565-3160<br />

46-(0)300-69 00 40<br />

41-(0)52-6258425<br />

02-2298-8889<br />

223-4220-3<br />

90-(0)212-2754876<br />

44-(0)1707-276-100<br />

598-2-92-08-08<br />

58-2-241-7634<br />

848-821-6453<br />

Safety Tips : Be sure to read the instruction manual fully before using this product.<br />

L-172-C5411-A FY0105 Printed in Japan (HAK)<br />

New publication,effective May 2001<br />

Specifications subject to change without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!