1.2mm Bone Screws<br />

1.7mm Bone and Locking Screws<br />

Standard Plates<br />

Thickness: 0.55mm<br />

Standard Plates<br />

Thickness: 0.55mm<br />

Dedicated Rotation Plates<br />

• Locking and standard versions.<br />

• Use with 1.7mm or 2.3mm screws.<br />

• Allows for correction on the<br />

rotational and lengthwise axis.<br />

Locking Plates<br />

Thickness: 1.0mm<br />

Dedicated MC5 Fracture Plates<br />

• Anatomically shaped.<br />

• Use with 2.3mm screws.<br />

• Oblong hole allows for adjustment<br />

in relation to the joint.<br />

• Locking feature may provide the stability<br />

needed to support the metaphyseal region.<br />

Locking Plates<br />

Thickness: 1.5mm<br />

Compression Plates<br />

Thickness: 1.0mm and 1.3mm<br />

Standard Plates<br />

Thickness: 1.0mm<br />

2.3mm Bone and Locking Screws<br />

Advanced Screw Design Patented SmartLock Locking Technology* Anodization Type II Treatment on<br />

Locking Plates**<br />

-10° +10°<br />

• One-Step Screw Pick Up. The cross pin head helps<br />

guide the screwdriver blade for proper blade/screw<br />

alignment and does not require grasping sleeves.<br />

• Rounded, Low-Profile Screw Heads. No screw head<br />

prominence even at the maximum locking screw<br />

angulation. This may reduce the risk of soft tissue<br />

irritation.<br />

• Blunt Screw Tips. All screws have a blunt tip<br />

and remain self tapping. This may reduce the risk<br />

of soft tissue irritation at the far cortex.<br />

• Allows locking up to ±10° in any direction.<br />

• One-step locking achieved by simply inserting the<br />

screw in the pre-drilled ±10° locking range.<br />

• May Increase strength.<br />

• May Reduce incidences of tissue adherence.<br />

• May Improve tissue glide.<br />

*The SmartLock Technology is patented (US 6,322,562 DE 43 43 117) by Professor Dietmar Wolter, Hamburg, Germany.”<br />

**Baumann A., Zander, N.; “Ti6Al4V with Anodization Type II: Biological Behavior and Biomechanical Effects“, March 2005.<br />

Note: Locking screws are not for use in standard or compression plates, while bone screws can be used with all plate types.