24.05.2014 Views

FIRE DAMPERS BSK-R & BSK-E EI 90 (v - Pichler

FIRE DAMPERS BSK-R & BSK-E EI 90 (v - Pichler

FIRE DAMPERS BSK-R & BSK-E EI 90 (v - Pichler

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>BSK</strong>-R-M AND <strong>BSK</strong>-R-L CIRCULAR <strong>FIRE</strong> <strong>DAMPERS</strong> PAGE 4<br />

MODEL INSTALLATION FITTING OPTIONS DEPENDENT ON THE SUPPORTING STRUCTURE FOR CLASSIFICATION <strong>EI</strong> <strong>90</strong> (S)<br />

in any position<br />

related to the axis<br />

of the fire damper<br />

flap<br />

Solid wall<br />

Installation with grouting or soft seal<br />

(gap all-round max. 300/400 mm)<br />

Solid ceiling<br />

Installation with grouting or soft seal<br />

(gap all-round max. 300/400 mm)<br />

Light wall in conjunction<br />

with soft seal<br />

(metal stud wall covered on<br />

two sides, gap all-round max.<br />

300 mm)<br />

Light wall in conjunction<br />

with panel seal<br />

(metal stud wall covered on two<br />

sides, mineral wool and cover<br />

panel)<br />

Grout<br />

(v e<br />

, i o)<br />

Soft seal<br />

(v e<br />

, i o)<br />

Grout<br />

(h o<br />

, i o)<br />

Soft seal<br />

(h o<br />

, i o)<br />

Soft seal<br />

(v e<br />

, i o)<br />

Panel seal<br />

(v e<br />

, i o)<br />

<strong>BSK</strong>-R-L<br />

-<br />

<strong>BSK</strong>-R-M<br />

<strong>BSK</strong>-E-L<br />

(in conjunction with optional IFW<br />

installation frame)<br />

<strong>BSK</strong>-E-M<br />

(max. 1500 x<br />

800 mm)<br />

(max. 1200 x<br />

800 mm)<br />

(max. 1500 x<br />

800 mm)<br />

(max. 1200 x<br />

800 mm)<br />

(max. 1200 x<br />

800 mm)<br />

Alternative soldered struts<br />

End position switches and position display<br />

MODEL<br />

DESCRIPTION<br />

MODEL<br />

DESCRIPTION<br />

FUS 72<br />

Alternative soldered strut with<br />

trigger temperature 72°C for<br />

<strong>BSK</strong>, lightweight variant<br />

FDCUM<br />

End position switch fitted.<br />

Suitable for <strong>BSK</strong>, lightweight<br />

variant. 2 end switches are<br />

fitted.<br />

FTH 72<br />

FCUM<br />

Alternative soldered strut with<br />

trigger temperature 72°C for<br />

<strong>BSK</strong>, solid variant<br />

End position switch fitted.<br />

Suitable for <strong>BSK</strong>, solid variant.<br />

Visualisation "CLOSED".<br />

DCUM<br />

End position switch fitted.<br />

Suitable for <strong>BSK</strong>, solid variant.<br />

Visualisation "OPEN"<br />

Subject to changes<br />

Pictures: Archive at J. <strong>Pichler</strong> Gesellschaft m.b.H., Paul Salu - Fotalia<br />

Version: 02/2013 kp<br />

J. PICHLER<br />

Gesellschaft m.b.H.<br />

office@pichlerluft.at<br />

www.pichlerluft.at<br />

AUSTRIA<br />

<strong>90</strong>21 KLAGENFURT<br />

AM WÖRTHERSEE<br />

Karlweg 5<br />

T +43 (0)463 32769<br />

F +43 (0)463 37548<br />

AUSTRIA<br />

1100 VIENNA<br />

Doerenkampgasse 5<br />

T +43 (0)1 6880988<br />

F +43 (0)1 6880988-13<br />

Sales offices in Slovenia, Croatia and Serbia. Sales partners in Germany, Switzerland and Italy.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!