ORDER INFORMATION<br />

B-<strong>SERIES</strong> TEMPERATURE SWITCH MODEL NUMBER:<br />

To specify the exact switch desired, select entries from appropriate tables as shown in example below.<br />

1 2 3<br />

4<br />

T 4 2 0 T 0 5 030<br />

5<br />

X N H<br />

6<br />

150° to 260°F<br />

T4<br />

T7<br />

1 – ENCLOSURE<br />

Temperature switch, type 400, watertight enclosure<br />

meets NEMA 3, 4, 4X, 13 and IP66 requirements.<br />

Temperature switch, type 700, explosion-proof<br />

enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66<br />

requirements.<br />

2 – SWITCH ELEMENT SELECTION<br />

Order<br />

Switch Elements<br />

Code<br />

UL/CSA Listed SPDT<br />

20 (7) Narrow deadband ac 15A, 125/250 Vac<br />

21 Ammonia service 5A, 125/250 Vac<br />

22 (6) Hermetically sealed switch, 5A, 125/250 Vac<br />

narrow deadband<br />

23 Heavy duty ac 22A, 125/250 Vac<br />

24 (1) General purpose 15A, 125/250/480 Vac<br />

1<br />

⁄2A, 125 Vdc<br />

1<br />

⁄4A, 250 Vdc; 6A, 30 Vdc<br />

25 (2) Heavy duty dc 10A, 125 Vac or dc,<br />

1<br />

⁄8 HP, 125 Vac or dc<br />

26 (7) Sealed environment proof 15A, 125/250 Vac<br />

27 High temperature 300°F 15A, 125/250 Vac<br />

28 (5) Manual reset trip on 15A, 125/250 Vac<br />

increasing<br />

29 (5) Manual reset trip on 15A, 125/250 Vac<br />

decreasing<br />

31 Low level (gold) contacts 1A, 125 Vac<br />

32 Hermetically sealed switch, 11A, 125/250 Vac<br />

general purpose<br />

5A, 30 Vdc<br />

50 Variable deadband 15A, 125/250 Vac<br />

UL/CSA Listed Dual (2 SPDT)<br />

61 (7) Dual narrow deadband 15A, 125/250 Vac<br />

62 (7) Dual sealed environment 15A, 125/250 Vac<br />

proof<br />

63 Dual high temp. 300°F 15A, 125/250 Vac<br />

64 Dual general purpose 15A, 125/250/480 Vac<br />

1<br />

⁄2A, 125 Vdc<br />

1<br />

⁄4A, 250 Vdc<br />

65 Dual ammonia service 5A, 125/250 Vac<br />

67 (4,6) Dual hermetically sealed 5A, 125/250 Vac<br />

switch, narrow deadband<br />

68 (4) Dual hermetically sealed 11A, 125/250 Vac<br />

switch, general purpose 5A, 30 Vdc<br />

71 Dual hermetically sealed 1A, 125 Vac<br />

switch, gold contacts<br />

3 – THERMAL SYSTEM SELECTION<br />

Direct Mount<br />

Order Code System Material Style<br />

TS 3l6 SS Rigid<br />

Remote Mount<br />

Order Code System Material Line Length Style (9)<br />

T05 316 SS 5´ Capillary<br />

T10 316 SS 10´ with<br />

T15 316 SS 15´ 302 SS<br />

T20 316 SS 20´ Spring<br />

T25 316 SS 25´ Armor<br />

4 – BULB LENGTH SELECTION<br />

Direct Mount<br />

Minimum<br />

Order “S” Thermowell<br />

Code Dimension “U” Dimension<br />

027 (8) 2 3 ⁄4˝ –<br />

040 4˝ 2 1 ⁄2˝<br />

060 6˝ 4 1 ⁄2˝<br />

090 9˝ 7 1 ⁄2˝<br />

120 12˝ 10 1 ⁄2˝<br />

Remote Mount<br />

030 (9) 3˝ 2 1 ⁄2˝<br />

6 – STANDARD TEMPERATURE<br />

RANGE SELECTION<br />

Adjustable Range<br />

°F °C<br />

–40 to 600 –40 to 160<br />

0 to 100 –40 to 400<br />

75 to 205 20 to 95<br />

150 to 260 65 to 125<br />

235 to 375 110 to 190<br />

350 to 525 175 to 275<br />

500 to 750 260 to 400<br />

NOTES:<br />

1 Standard switch.<br />

2 Available with remote mount<br />

thermal systems only.<br />

3 Dual switches are 2 SPDT<br />

snap-action switches, not<br />

independently adjustable.<br />

4 Not available with type 400<br />

enclosure.<br />

5 Not available with type 700<br />

enclosure.<br />

5 – OPTIONS<br />

Use table on<br />

page 9<br />

6 Estimated dc rating, 2.5A,<br />

28 Vdc (not UL listed).<br />

7 Estimated dc rating, 0.4A,<br />

120 Vdc (not UL listed).<br />

8 Not available on 350 to 525°F.<br />

9 Consult factory on remote<br />

mount for bulb lengths other<br />