Focus Servo is unstable<br />
Is FE signal<br />
output normal in Focusing<br />
Up/Down?<br />
(LIC121 pin25*)<br />
NO<br />
Check P<strong>ic</strong>kup Read Power<br />
is 1.3~1.7mW?<br />
NO<br />
Replace the P<strong>ic</strong>k up.<br />
YES<br />
Replace the LIC121.<br />
Is FDRV signal<br />
output normal in Focusing<br />
Up/Down?<br />
(LIC201 pin 62)<br />
NO<br />
Replace the LIC201.<br />
YES<br />
Go to “Focus Actuator<br />
operating is abnormal”<br />
* LIC121 pin25 is MOUT2(FEP Monitor2).<br />
After disc recognition action, Monitor port<br />
is off. So, please check FE signal during<br />
disc recognition.<br />
Focus Actuator operating is<br />
abnormal<br />
Is there Focus<br />
Search control signal input?<br />
(LIC301 pin5)<br />
YES<br />
NO • Check the connection of LIC201 pin 62.<br />
• Check the commun<strong>ic</strong>ation line between<br />
LIC121 and LIC201.<br />
• Replace the LIC201.<br />
Is there Focus<br />
Search drive voltage output?<br />
(LIC301 pin 51,52)<br />
NO<br />
Is DRVMUTE2 signal “H”?<br />
(LIC301 pin 35)<br />
NO<br />
Check the connection of LIC121 pin 32.<br />
Replace the LIC121.<br />
YES<br />
YES<br />
Check the connection<br />
LPM101 pin40, 41.<br />
Replace the LIC301.<br />
Replace the P<strong>ic</strong>k-Up.<br />
4-7