Tmax<br />

MCCBs<br />

Tmax UL489B<br />

Molded case circuit breakers and switches<br />

T4 - 200A Frame TMA, Thermal magnetic adjustable<br />

Catalog<br />

IC at 1000VDC Rating Lugs Poles in Series<br />

number<br />

2+1 T4PB040TL<br />

3kA 40A Yes<br />

3 T4PA040TL<br />

2+1 T4PB050TL<br />

3kA 50A Yes<br />

3 T4PA050TL<br />

2+1 T4PB080TL<br />

3kA 80A Yes<br />

3 T4PA080TL<br />

2+1 T4PB100TL<br />

3kA 100A Yes<br />

3 T4PA100TL<br />

2+1 T4PB125TL<br />

3kA 125A Yes<br />

3 T4PA125TL<br />

2+1 T4PB150TL<br />

3kA 150A Yes<br />

3 T4PA150TL<br />

2+1 T4PB200TL<br />

3kA 200A Yes<br />

3 T4PA200TL<br />

T5 - 400A Frame TMA, Thermal magnetic adjustable<br />

Catalog<br />

IC at 1000VDC Rating Lugs Poles in Series<br />

number<br />

2+1 T5PB400TL<br />

5kA 400A Yes<br />

3 T5PA400TL<br />

2+1 T5PB400TW<br />

5kA 400A No<br />

3 T5PA400TW<br />

T6 - 800A Frame TMA, Thermal magnetic adjustable<br />

Catalog<br />

IC at 1000VDC Rating Lugs Poles in Series<br />

number<br />

2+2 T6PB600TL-4<br />

10kA 600A Yes<br />

4 T6PA600TL-4<br />

2+2 T6PB800TW-4<br />

10kA 800A No<br />

4 T6PA800TW-4<br />

T1-D 100A Molded case switch<br />

Catalog<br />

Rating Lugs Poles in Series<br />

number<br />

2+2 T1PB100DL-4<br />

100A<br />

Yes<br />

4 T1PA100DL-4<br />

T4-D 200A Molded case switch<br />

Catalog<br />

Rating Lugs Poles in Series<br />

number<br />

2+1 T4PB200DL<br />

200A<br />

Yes<br />

3 T4PA200DL<br />

T5-D 400A Molded case switch<br />

Catalog<br />

Rating Lugs Poles in Series<br />

number<br />

2+1 T5PB400DL<br />

400A<br />

Yes<br />

3 T5PA400DL<br />

2+1 T5PB400DW<br />

400A<br />

No<br />

3 T5PA400DW<br />

T6-D 800A Frame molded case switch<br />

Catalog<br />

Rating Lugs Poles in Series<br />

number<br />

2+2 T6PB600DL-4<br />

600A<br />

Yes<br />

4 T6PA600DL-4<br />

2+2 T6PB800DW-4<br />

800A<br />

No<br />

4 T6PA800DW-4<br />

T7-D 1000A Molded case switch<br />

Catalog<br />

Rating Lugs Poles in Series<br />

number<br />

2+2 T7MPB1000DL-4<br />

1000A<br />

Yes<br />

4 T7MPA1000DL-4<br />

NOTE: All poles in series is for use in grounded systems.<br />

2+1 or 2+2 configurations are for ungrounded systems.<br />

17<br />

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com