Pre-development hydrologic analysis and calculations that determines the existing storm water<br />

runoff volumes, peak flow rates and flow velocities.<br />

Post-development hydrologic analysis and calculations that determines the storm water runoff<br />

volumes, peak flow rates and flow velocities.<br />

A 360 degree map showing:<br />

Data to support the hydrology model<br />

Areas delineated, curve numbers (CNs), slopes, contours, flow path segments<br />

Photography<br />

Network diagram for the hydrology model<br />

Storm water management control facility design:<br />

Narrative describing the storm water management control facilities selected.<br />

Location of all storm water management control facilities.<br />

Supporting calculations that justify that the facilities meets the <strong>Greenville</strong> <strong>County</strong> Storm<br />

Water Management Permit requirements. Includes hydrographs, stage storage volumes, and<br />

stage discharge values for water quantity and water quality control facilities and design<br />

calculations and elevations for all storm water conveyance systems.<br />

A permanent maintenance plan for each permanent storm water management facility.<br />

Erosion and sediment control plan:<br />

Narrative describing the erosion and sediment control facilities selected.<br />

Location of all erosion and sediment control facilities.<br />

Resulting design calculations and trapping efficiencies for all sediment control facilities.<br />

Downstream analysis calculations showing the effect of post-development design flows on<br />

downstream storm water conveyance systems and channels.<br />

Minimum Preliminary Site Development Plan Requirements<br />

All Preliminary Site Development Plans shall include as a minimum the following:<br />

A vicinity map indicating a north arrow, scale, boundary lines of the site and other information<br />

necessary to locate the development site.<br />

The existing and proposed topography of the development site except for individual lot grading<br />

plans in single-family subdivisions.<br />

Physical improvements on the site, including present development and proposed development.<br />

Location, dimensions, elevations, and characteristics of all storm water management facilities. As a<br />

minimum, easements shall have the following characteristics.<br />

Provide adequate access to all portions of the drainage system and structures.<br />

Provide sufficient land area for maintenance equipment and personnel to adequately and<br />

efficiently maintain the drainage system and all storm water facilities.<br />

Restriction on easements shall include prohibiting all fences and structures which would<br />

<strong>Greenville</strong> <strong>County</strong>, South Carolina<br />

January 2013 Storm Water Management <strong>Design</strong> <strong>Manual</strong> 3-6