Section 1900<br />
Structural Steel<br />
IS:4260 or any other relevant IS Specification and as agreed to by<br />
the Engineer.<br />
iv)<br />
Liquid Penetration Inspection : The liquid penetrant test shall be<br />
carried out for detection of surface defect in the weld, as per IS:3658,<br />
in addition to visual inspection<br />
The non-destructive testing of following welds be carried out using<br />
one of the method or methods described at (ii), (iii) and (iv) above,<br />
as may be agreed to by the Engineer.<br />
a) All transverse butt welds in tension flange<br />
b) 10 percent of the length of longitudinal and transverse butt<br />
welds in tension flanges.<br />
c) 5 percent of the length of longitudinal and transverse butt welds<br />
in compression flanges.<br />
d) All transverse butt welds in webs adjacent to tension flanges<br />
as specified by the Engineer.<br />
The particular length of welds in webs to be tested shall be agreed with the Engineer, in<br />
case (b) or (c).<br />
Where specified by the Engineer, bearing stiffeners or bearing diaphragms adjacent to<br />
welds, flange plates adjacent to web/flange welds, plates at cruciform welds, plates in box<br />
girder construction adjacent to corner welds or other details shall be ultrasonically tested<br />
after fabrication.<br />
Any lamination, lamellar tearing or other defect found shall be recorded and reported to<br />
the Engineer for his decision.<br />
Testing of Welding for Cast Steel : The testing of weld for cast steel shall be carried out<br />
as may be agreed to by the Engineer.<br />
Stud Shear Connectors : Stud shear connectors shall be subjected to the following<br />
tests :<br />
a) The fixing of studs after being welded in position shall be tested by<br />
striking the side of the head of the stud with a 2 kg hammer to the<br />
satisfaction of the Engineer.<br />
b) The selected stud head stroked with 6 kg hammer shall be capable<br />
of lateral displacement of approximately 0.25 the height of the stud<br />
from its original position. The stud weld shall not show any sign of<br />
crack or lack of fusion.<br />
26