MULTISPLITS DC INVERTER<br />
R <strong>410</strong> A<br />
APPLICATIONS<br />
RESIDENTIAL AND SERVICE SECTOR<br />
(OFFICES, SHOPS)<br />
CONSOLE FLOOR/CEILING MOUNTED WALL-MOUNTED CASSETTE DUCTABLE<br />
Technology DC Inverter =<br />
performance, comfort and saving<br />
A total comfort thanks to rapid warm-up and strict control<br />
of the desired temperature.<br />
A significant reduction in energy consumption (up to 40%)<br />
A longer operating life due to the reduction in ON/OFF<br />
cycles.<br />
>Several possible combinations :<br />
3 outdoor units and 15 indoor units<br />
>Exceptional performance coefficient<br />
in cooling and heating mode.<br />
>Very great length of piping up to 70 meters<br />
with a high difference up to 10 meters.<br />
>An exceptional large range of operation.<br />
36
Direct expansion<br />
MULTISPLITS SYSTEM<br />
DC INVERTER<br />
R <strong>410</strong> A<br />
Multisplits DC Inverter<br />
R <strong>410</strong> A<br />
38<br />
> Dual split<br />
> Tri-split<br />
> Quadri-split<br />
Air/Air heat pump<br />
COP : 4.61<br />
RENEWABLE ENERGIES<br />
SAVINGS<br />
COP<br />
5<br />
4,5<br />
4<br />
3,5<br />
3<br />
GRF194 MR5I GRF244 MR5I GRF314 MR5I<br />
ATTENTION<br />
These products are not available<br />
in some countries. Please, consult us.<br />
une avance dans l’air du temps<br />
37
MULTISPLITS DC INVERTER<br />
R <strong>410</strong> A<br />
RENEWABLE ENERGIES<br />
SAVINGS<br />
GRF 194/244 MR 5I<br />
GRF 314 MR 5I<br />
Air/Air heat pump<br />
><br />
• Cooling and Heating air-conditioner for cooling, dehumidication and heating modes<br />
• DC Inverter technology on R <strong>410</strong> A with continuous regulation of the refrigerant flow rate<br />
• Nominal cooling capacity : from 2.8 to 9 kW<br />
Nominal heating capacity : from 4 to 10 kW<br />
• 2 refrigerant valves (bi-splits), 3 valves (tri-splits) or 4 valves (quadri-splits) controlled by an electronic<br />
microprocessor system<br />
• Each indoor unit is managed by its own remote control<br />
• In case of several indoor units installed in the same room, it is possible to address every remote control<br />
to its own indoor unit only, so that to avoid any interference<br />
• At least 2 indoor units must be connected to the outdoor unit ; only 1 indoor unit<br />
may be operating<br />
• High efficiency double rotary DC Inverter compressor<br />
ACCESSORIES<br />
Type Models Code<br />
Plenum with circular spiggots (discharge) 2 spiggots DSAF 94 - 124 K 70 M 009 T<br />
Ø 200 m 3 spiggots DSAF 184 - 224 K 70 M 010 T<br />
Wall support for indoor unit GRF 194 - 244 - 314 MR5I K 60 U 035 T<br />
Filter with active charcoal KPAF 397021907<br />
Drain kit GRF 194 - 244 - 314 MR5I 387027088<br />
38
MULTISPLITS DC INVERTER<br />
OUTDOOR UNIT - AIR/AIR HEAT PUMP<br />
Outdoor unit<br />
Number of indoor units<br />
Max. capacity of connected IU<br />
kW<br />
Capacity (mini-maxi)<br />
kW<br />
Energy class<br />
ABCDEFG<br />
EER / COP<br />
kW<br />
Air flow (m 3 /h)<br />
HS<br />
Fan speeds<br />
Power supply<br />
V/Ph/Hz<br />
Input power<br />
kW<br />
Annual energy consumption in cooling mode (500h) kWh<br />
Refrigerant type<br />
Compressor type<br />
Liquid pipe diameter<br />
inches<br />
Gas pipe diameter<br />
inches<br />
Max. distance between units/unit<br />
m<br />
Max. total tubing length<br />
m<br />
Max. height difference between units<br />
m<br />
Sound pressure level (dB(A))<br />
HS<br />
Net weight<br />
kg<br />
Height x width x depth<br />
mm<br />
OPERATING LIMITS<br />
COOLING maximum T indoor air 32°C (DB) / 23°C (WB)<br />
T outdoor air 43°C (DB)<br />
minimum T indoor air 19°C (DB )/ 14°C (WB)<br />
T outdoor air 19°C (DB)<br />
GRF 194 MR 5I GRF 244 MR 5I GRF 314 MR 5I<br />
Cooling Heating<br />
2<br />
8.6<br />
5.6 (1.4-6.5) 7.3 (1.7-8.4)<br />
B<br />
B<br />
3.13 3.46<br />
2 400<br />
2 (auto)<br />
230/1/50<br />
1.79 2.11<br />
895 -<br />
R <strong>410</strong> A<br />
Twin Rotary (DC inverter)<br />
1/4 x 2<br />
3/8 x 2<br />
25<br />
35<br />
10<br />
48 49<br />
69<br />
730x940x340<br />
Cooling Heating<br />
2 to 3<br />
11.4<br />
6.8 (1.4-8.1) 8.6 (1.7-9.0)<br />
A<br />
A<br />
3.33 3.81<br />
2 400<br />
2 (auto)<br />
230/1/50<br />
2.04 2.26<br />
1 020 -<br />
R <strong>410</strong> A<br />
Twin Rotary (DC inverter)<br />
1/4 x 3<br />
3/8 x 3<br />
25<br />
50<br />
10<br />
48 49<br />
70<br />
730x940x340<br />
HEATING maximum T indoor air 27° C (DB)<br />
T outdoor air 24°C (DB) / 18°C (WB)<br />
minimum T indoor air 16° C (DB)<br />
T outdoor air -15°C (WB)<br />
Cooling Heating<br />
2 to 4<br />
15.4<br />
9 (1.2-10.5) 10 (1.7-10.8)<br />
A<br />
A<br />
4.64 4.61<br />
2 800<br />
2 (auto)<br />
230/1/50<br />
1.94 2.17<br />
970 -<br />
R <strong>410</strong> A<br />
Twin Rotary (DC inverter)<br />
1/4 x 4<br />
3/8 x3 - 1/2 x 1<br />
30<br />
70<br />
10<br />
53 54<br />
90<br />
880x940x340<br />
MULTISPLITS SYSTEM<br />
DC INVERTER<br />
R <strong>410</strong> A<br />
COMBINATIONS WITH GRF 194 MR 5I<br />
GRF 194 MR 5 I<br />
2 indoor units<br />
94 + 94<br />
94 + 124<br />
94 + 184<br />
124 + 124<br />
124 + 184<br />
COMBINATIONS WITH GRF 244 MR 5I<br />
2 indoor units<br />
94 + 94<br />
94 + 124<br />
94 + 184<br />
124 + 124<br />
124 + 184<br />
GRF 244 MR 5 I<br />
3 indoor units<br />
94 + 94 +94<br />
94 + 94 +124<br />
94 + 94 + 184<br />
94 + 124 +124<br />
94 + 124 + 184<br />
124 + 124 +124<br />
COMBINATIONS WITH GRF 314 MR 5I<br />
2 indoor units<br />
94 + 94<br />
94 + 124<br />
94 + 184<br />
124 + 124<br />
124 + 184<br />
94 + 244/224<br />
GRF 314 MR 5 I<br />
3 indoor units<br />
94 + 94 +94<br />
94 + 94 +124<br />
94 + 94 + 184<br />
94 + 94 + 244/224<br />
94 + 124 +124<br />
94 + 124 + 184<br />
124 + 124 +124<br />
124 + 124 + 184<br />
4 indoor units<br />
94 + 94 + 94 + 94<br />
94 + 94 + 94 + 124<br />
94 + 94 + 94 + 184<br />
94 + 94 + 94 + 244/224<br />
94 + 94 + 124 + 124<br />
94 + 94 + 124 + 184<br />
94 + 124 + 124 + 124<br />
94 + 124 + 124 + 184<br />
124 + 124 + 124 +124<br />
une avance dans l’air du temps<br />
39
MULTISPLITS DC INVERTER<br />
R <strong>410</strong> A<br />
WALL-MOUNTED<br />
MCAF 94/124/184/244 MR5I<br />
MCAF 94 MR 5 I<br />
><br />
MCAF 124 MR 5 I<br />
MCAF 184 MR 5 I<br />
MCAF 244 MR 5 I<br />
• Wall-mounted indoor units for MULTISPLIT DC Inverter system<br />
• Automatic changeover between Cooling/Heating functions to maintain selected temperature<br />
• Special system when heating mode is starting and during defrosting cycle to avoid cool air emission in the<br />
room<br />
• Infrared remote control<br />
• Temperature sensor enclosed in the remote control<br />
• “I feel” feature granting the best comfort conditions<br />
• Dry function for dehumidification<br />
• Programmable or automatic three-speed tangential fan granting a low noise air diffusion<br />
• Horizontal flaps with automatic swinging or programmable in a fixed position<br />
• Adjustable vertical flaps<br />
• Night setback program<br />
• Anti-mould and anti-bacteria washable filter<br />
• Two-way condensate discharge (right, left)<br />
Indoor units MCAF 94 MR 5 I MCAF 124 MR 5 I MCAF 184 MR 5 I MCAF 244 MR 5 I<br />
Nominal capacity<br />
kW<br />
(mini - maxi)<br />
Air flow (m 3 /h)<br />
LS/MS/HS<br />
Dehumidification<br />
l/h<br />
Fan speeds<br />
nb<br />
Power supply<br />
V/Ph/Hz<br />
Running current<br />
A<br />
Input power<br />
kW<br />
Deflection<br />
horizontal<br />
vertical<br />
Ø Refrigerant connections<br />
(inches)<br />
External Ø of condensate drain pipe (mm)<br />
Sound power level (dB(A))<br />
Sound pressure level (dB(A)) LS/MS/HS<br />
Net weight<br />
kg<br />
Height x width x depth<br />
mm<br />
40<br />
Cooling Heating<br />
2.8 4<br />
(0.7-3.2) (0.9-5.4)<br />
370 / 510 / 620<br />
1.6 -<br />
3 - auto<br />
230/1/50<br />
0.13 0.14<br />
0.026 0.028<br />
manual<br />
auto<br />
1/4 - 3/8<br />
16<br />
42 / 47 / 50<br />
33 / 38 / 41<br />
8.5<br />
275 x 805 x 178<br />
Cooling Heating<br />
3.6 4.8<br />
(0.8-3.6) (0.9-6.3)<br />
400 / 450 / 580<br />
2.0 -<br />
3 - auto<br />
230/1/50<br />
0.13 0.12<br />
0.025 0.025<br />
manual<br />
auto<br />
1/4 - 3/8<br />
16<br />
42 / 48 / 55<br />
33 / 39 / 46<br />
9.5<br />
285 x 805 x 219<br />
Cooling Heating<br />
5 7.1<br />
(1.1-5.8) (1.2-7.8)<br />
530 / 620 / 680<br />
2.3 -<br />
3 - auto<br />
230/1/50<br />
0.12 0.12<br />
0.025 0.025<br />
manual<br />
auto<br />
1/4 - 3/8<br />
16<br />
47 / 53 / 58<br />
38 / 44 / 49<br />
9.5<br />
285 x 805 x 219<br />
Cooling Heating<br />
7 8.0<br />
(1.5-8.1) (2.0-8.8)<br />
920 / 1 000 / 1 100<br />
4.0 -<br />
3 - auto<br />
230/1/50<br />
0.27 0.28<br />
0.063 0.065<br />
manual<br />
auto<br />
1/4 - 1/2<br />
16<br />
47 / 52 / 56<br />
38 / 43 / 47<br />
18<br />
330 x 1 140 x 228
MULTISPLITS DC INVERTER<br />
CONSOLE<br />
KAF 94 MR5I<br />
R <strong>410</strong> A<br />
FLOOR/CEILING<br />
KPAF 124/184/224 MR5I<br />
MULTISPLITS SYSTEM<br />
DC INVERTER<br />
R <strong>410</strong> A<br />
><br />
KAF<br />
KPAF<br />
• Console or floor/ceiling indoor unit for MULTISPLIT DC Inverter system<br />
• Automatic changeover between Heating and Cooling functions to maintain selected temperature<br />
• Special system when heating mode is starting and during defrosting cycle to avoid cool air emission in the<br />
room<br />
• Infrared remote control<br />
• Temperature sensor enclosed in the remote control<br />
• “I feel” feature granting the best comfort conditions<br />
• Dry function for dehumidification<br />
• Programmable or automatic three-speed tangential fan granting a low noise air diffusion (KPAF)<br />
• Adjustable horizontal flaps (KAF)<br />
• Horizontal flaps with automatic swinging or to be set to a fixed position (KPAF)<br />
• Adjustable vertical flaps<br />
• Night setback program<br />
• Anti-mould and anti-bacteria washable filters<br />
• Active charcoal filter as accessory (KPAF)<br />
Indoor units<br />
Nominal capacity<br />
kW<br />
(mini - maxi)<br />
Air flow (m 3 /h)<br />
LS/MS/HS<br />
Dehumidification<br />
l/h<br />
Fan speeds<br />
nb<br />
Power supply<br />
V/Ph/Hz<br />
Running current<br />
A<br />
Input power<br />
kW<br />
Deflection<br />
horizontal<br />
vertical<br />
Ø Refrigerant connections FLARE (inches)<br />
External Ø of condensate drain pipe (mm)<br />
Sound power level (dB(A))<br />
LS/MS/HS<br />
Sound pressure (dB(A))<br />
LS/MS/HS<br />
Net weight<br />
kg<br />
Height x width x depth<br />
mm<br />
KAF 94 MR 5 I KPAF 124 MR 5 I KPAF 184 MR 5 I KPAF 224 MR 5 I<br />
Cooling Heating<br />
2.8 4<br />
(0.7-3.2) (0.9-5.4)<br />
300 / 360 / 400<br />
1.0 -<br />
3 - auto<br />
230/1/50<br />
0.12 0.12<br />
0.026 0.028<br />
manual<br />
manual<br />
1/4 - 3/8<br />
18<br />
42 / 48 / 51<br />
34 / 40 / 43<br />
18.6<br />
700 / 560 / 200<br />
Cooling Heating<br />
3.6 4.8<br />
(0.8-3.6) (0.9-6.3)<br />
500 / 590 / 700<br />
1.3 -<br />
3 - auto<br />
230/1/50<br />
0.29 0.29<br />
0.065 0.065<br />
manual<br />
auto<br />
1/4 - 3/8<br />
18<br />
46 / 51 / 55<br />
38 / 43 / 47<br />
23.5<br />
680 / 900 / 190<br />
Cooling Heating<br />
5 7.1<br />
(1.1-5.8) (1.2-7.8)<br />
515 / 615 / 720<br />
2.3 -<br />
3 - auto<br />
230/1/50<br />
0.33 0.33<br />
0.075 0.075<br />
manual<br />
auto<br />
1/4 - 3/8<br />
18<br />
47 / 52 / 56<br />
39 / 44 / 48<br />
23.5<br />
680 / 900 / 190<br />
Cooling Heating<br />
7 8.0<br />
(1.5-8.1) (2.0-8.8)<br />
665 / 760 / 830<br />
3.3 -<br />
3 - auto<br />
230/1/50<br />
0.33 0.33<br />
0.075 0.075<br />
manual<br />
auto<br />
1/4 - 1/2<br />
18<br />
54 / 57 / 60<br />
46 / 49 / 52<br />
23.5<br />
680 / 900 / 190<br />
une avance dans l’air du temps<br />
41
MULTISPLITS DC INVERTER<br />
R <strong>410</strong> A<br />
CASSETTE<br />
CAF 94/124/184 MR5I<br />
><br />
• Cassette indoor unit for false ceiling installation – MULTISPLIT DC Inverter system<br />
• Automatic change-over between cooling and heating modes<br />
• Special function during heat pump start-up and during defrosting cycle to avoid cool air emission in the<br />
room<br />
• Infrared remote control<br />
• Temperature sensor inside the remote control<br />
• Night set back capability<br />
• “I feel” feature granting the best comfort conditions<br />
• Dry function for dehumidification<br />
• Programmable or automatic 3-speed centrifugal fan granting a low noise air diffusion<br />
• Flaps swinging or to be set to a fixed position by remote control<br />
• Anti-mould and anti-bacteria washable filter<br />
• Equipped with a condensate drain pump<br />
• Possibility to have a connection for fresh air intake<br />
Indoor units<br />
Grille<br />
Nominal capacity<br />
kW<br />
(mini - maxi)<br />
Air flow (m 3 /h)<br />
LS/MS/HS<br />
Dehumidification<br />
l/h<br />
Fan speeds<br />
nb<br />
Power supply<br />
V/Ph/Hz<br />
Running current<br />
A<br />
Input power<br />
kW<br />
Deflection<br />
vertical<br />
Ø Refrigerant connections FLARE (inches)<br />
External Ø of condensate drain pipe (mm)<br />
Sound power level (dB(A))<br />
LS/MS/HS<br />
Sound pressure (dB(A))<br />
LS/MS/HS<br />
Weight I.U. / Grille<br />
(kg)<br />
Grille (Height x Width x Depth)<br />
(mm)<br />
Height x Width x Depth<br />
(mm)<br />
CAF 94 MR 5 I<br />
K 70 N 096 T<br />
Cooling Heating<br />
2.8 4<br />
(0.7-3.2) (0.9-5.4)<br />
500 / 600 / 700<br />
0.5 -<br />
3 - auto<br />
230/1/50<br />
0.41 0.41<br />
0.087 0.087<br />
auto<br />
1/4 - 3/8<br />
18<br />
46 / 49 / 53<br />
37 / 40 / 44<br />
16.5 + 2.5<br />
296 x 575 x 575<br />
64 x 730 x 730<br />
CAF 124 MR 5 I<br />
K 70 N 096 T<br />
Cooling Heating<br />
3.6 4.8<br />
(0.8-3.6) (0.9-6.3)<br />
500 / 600 / 700<br />
1.0 -<br />
3 - auto<br />
230/1/50<br />
0.41 0.41<br />
0.087 0.087<br />
auto<br />
1/4 - 3/8<br />
18<br />
46 / 49 / 53<br />
37 / 40 / 44<br />
16.5 + 2.5<br />
296 x 575 x 575<br />
64 x 730 x 730<br />
CAF 184 MR 5 I<br />
K 70 N 096 T<br />
Cooling Heating<br />
5 7.1<br />
(1.1-5.8) (1.2-7.8)<br />
580 / 660 / 790<br />
2.3 -<br />
3 - auto<br />
230/1/50<br />
0.41 0.41<br />
0.087 0.087<br />
auto<br />
1/4 - 3/8<br />
18<br />
46 / 49 / 54<br />
37 / 40 / 45<br />
18.2 + 2.5<br />
296 x 575 x 575<br />
64 x 730 x 730<br />
42
MULTISPLITS DC INVERTER<br />
R <strong>410</strong> A<br />
DUCTABLE<br />
DSAF 94/124/184/224 MR5I<br />
MULTISPLITS SYSTEM<br />
DC INVERTER<br />
R <strong>410</strong> A<br />
><br />
• Ductable indoor units for MULTISPLIT DC Inverter system<br />
• With or without 2 or 3 ducts (plenum as accessory)<br />
• Automatic change-over cooling and heating modes<br />
• Special function during heat pump start-up and during defrosting cycle to avoid cool air emission in the<br />
room<br />
• Infrared remote control<br />
• “I feel” feature allowing the best comfort conditions<br />
• Temperature sensor inside the remote control<br />
• Night set back program<br />
• Dry function for dehumidification without cooling mode<br />
• Automatic three-speed centrifugal fan by remote control and available pressure from 50 to 70 Pa<br />
• Easy to modify the available pressure on site<br />
• Anti-mould and anti-bacteria washable filter<br />
• Equipped with a condensate drain pump<br />
Indoor unit DSAF 94 MR 5 I DSAF 124 MR 5 I DSAF 184 MR 5 I DSAF 224 MR 5 I<br />
Cooling Heating Cooling Heating Cooling Heating Cooling Heating<br />
Nominal capacity<br />
kW 2.8 4 3.6 4.8 5 7.1 7 8.0<br />
(mini - maxi) (0.7-3.2) (0.9-5.4) (0.8-3.6) (0.9-6.3) (1.1-5.8) (1.2-7.8) (1.5-8.1) (2.0-8.8)<br />
Air flow (m 3 /h)<br />
LS/MS/HS 470 / 560 / 620 470 / 560 / 620 455 / 645 / 865 530 / 760 / 985<br />
Dehumidification<br />
l/h 50 / 70*<br />
50 / 70*<br />
50 / 70*<br />
50 / 70*<br />
Fan speeds<br />
nb 0.8 - 1.5 - 2.3 - 2.6 -<br />
Power supply<br />
V/Ph/Hz 3 - auto<br />
3 - auto<br />
3 - auto<br />
3 - auto<br />
Running current<br />
A 230/1/50<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
Input power<br />
kW 0.45 0.45 0.45 0.45 0.6 0.6 0.6 0.6<br />
Deflection<br />
vertical 0.11 0.11 0.11 0.11 0.138 0.138 0.138 0.138<br />
Ø Refrigerant connections FLARE (inches) 1/4 - 3/8<br />
1/4 - 3/8<br />
1/4 - 3/8<br />
1/4 - 1/2<br />
External Ø of condensate drain pipe (mm)<br />
18<br />
18<br />
18<br />
18<br />
Sound power level (dB(A))<br />
LS/MS/HS 49 / 52 / 54<br />
49 / 52 / 54<br />
42 / 47 / 54<br />
46 / 49 / 57<br />
Sound pressure (dB(A))<br />
LS/MS/HS 40 / 43 / 45<br />
40 / 43 / 45<br />
33 / 38 / 45<br />
37 / 40 / 48<br />
Net weight (UI/Plenum)<br />
kg 30 / 6<br />
30 / 6<br />
35 / 7.5<br />
35 / 7.5<br />
Height x width x depth<br />
mm 266 x 926 x 571 266 x 926 x 571 266 x 1 132 x 571 266 x 1 132 x 571<br />
Height x width x depth with plenum mm 266 x 926 x 771 266 x 926 x 771 266 x 1 132 x 771 266 x 1 132 x 771<br />
*Fan booster<br />
une avance dans l’air du temps<br />
43
MULTISPLITS DC INVERTER<br />
R <strong>410</strong> A<br />
PERFORMANCE<br />
Outdoor unit<br />
Performance<br />
Combinations for 2 rooms<br />
1 unit operation<br />
2 units operation<br />
94<br />
124<br />
184<br />
94+94<br />
94+124<br />
94+184<br />
124+124<br />
124+184<br />
Cooling<br />
Indoor capacity (kW)<br />
Total<br />
capacity<br />
room A room B (kW)<br />
2.80 - 2.80<br />
3.60 - 3.60<br />
5.00 - 5.00<br />
2.80 2.80 5.60<br />
2.45 3.15 5.60<br />
2.00 3.60 5.60<br />
2.80 2.80 5.60<br />
2.35 3.25 5.60<br />
GRF 194 MR5I<br />
Heating<br />
Puissance int. (kW)<br />
Total<br />
capacity<br />
room A room B (kW)<br />
4.00 - 4.00<br />
4.80 - 4.80<br />
7.10 - 7.10<br />
3.65 3.65 7.30<br />
3.30 4.00 7.30<br />
2.65 4.65 7.30<br />
3.65 3.65 7.30<br />
2.95 4.35 7.30<br />
Outdoor unit<br />
Performance<br />
Combinations for 3 rooms<br />
1 unit operation<br />
2 units operation<br />
3 units operation<br />
94<br />
124<br />
184<br />
94+94<br />
94+124<br />
94+184<br />
124+124<br />
124+184<br />
94+94+94<br />
94+94+124<br />
94+94+184<br />
94+124+124<br />
94+124+184<br />
124+124+124<br />
Cooling<br />
Indoor capacity (kW)<br />
Total<br />
capacity<br />
room A room B room C (kW)<br />
2.80 - - 2.80<br />
3.60 - - 3.60<br />
5.00 - - 5.00<br />
2.80 2.80 - 5.60<br />
2.80 3.60 - 6.40<br />
2.45 4.35 - 6.80<br />
3.40 3.40 - 6.80<br />
2.85 3.95 - 6.80<br />
2.26 2.26 2.28 6.80<br />
2.07 2.07 2.65 6.80<br />
1.80 1.80 3.20 6.80<br />
1.90 2.45 2.45 6.80<br />
1.65 2.15 3.00 6.80<br />
2.26 2.26 2.28 6.80<br />
GRF 244 MR5I<br />
Heating<br />
Puissance int. (kW)<br />
Total<br />
capacity<br />
room A room B room C (kW)<br />
4.00 - - 4.00<br />
4.80 - - 4.80<br />
7.10 - - 7.10<br />
4.00 4.00 - 8.00<br />
3.90 4.70 - 8.60<br />
3.10 5.50 - 8.60<br />
4.30 4.30 - 8.60<br />
3.45 5.15 - 8.60<br />
2.86 2.88 2.86 8.60<br />
2.70 2.70 3.20 8.60<br />
2.30 2.30 4.00 8.60<br />
2.50 3.05 3.05 8.60<br />
2.15 2.60 3.85 8.60<br />
2.86 2.88 2.86 8.60<br />
Outdoor unit<br />
Performance<br />
Combinations for 4 rooms<br />
1 unit operation<br />
2 units operation<br />
3 units operation<br />
4 units operation<br />
94<br />
124<br />
184<br />
244/224<br />
94+94<br />
94+124<br />
94+184<br />
124+124<br />
124+184<br />
94 + 244/224<br />
94+94+94<br />
94+94+124<br />
94+94+184<br />
94+94+244/224<br />
94+124+124<br />
94+124+184<br />
124+124+124<br />
124+124+184<br />
94+94+94+94<br />
94+94+94+124<br />
94+94+94+184<br />
94+94+94+244/224<br />
94+94+124+124<br />
94+94+124+184<br />
94+124+124+124<br />
94+124+124+184<br />
124+124+124+124<br />
Cooling<br />
Indoor capacity (kW)<br />
GRF 314 MR5I<br />
Total<br />
capacity<br />
A B C D (kW)<br />
2.80 - - - 2.80<br />
3.60 - - - 3.60<br />
5.00 - - - 5.00<br />
7.00 - - - 7.00<br />
2.80 2.80 - - 5.60<br />
2.80 3.60 - - 6.40<br />
2.80 5.00 - - 7.80<br />
3.60 3.60 - - 7.20<br />
3.60 5.00 - - 8.60<br />
2.55 6.45 - - 9.00<br />
2.80 2.80 2.80 - 8.40<br />
2.75 2.75 3.50 - 9.00<br />
2.40 2.40 4.20 - 9.00<br />
2.00 2.00 5.00 - 9.00<br />
2.50 3.25 3.25 - 9.00<br />
2.20 2.85 3.95 - 9.00<br />
3.00 3.00 3.00 - 9.00<br />
2.65 2.65 3.70 - 9.00<br />
2.25 2.25 2.25 2.25 9.00<br />
2.10 2.10 2.10 2.70 9.00<br />
1.90 1.90 1.90 3.30 9.00<br />
1.65 1.65 1.65 4.05 9.00<br />
2.00 2.00 2.50 2.50 9.00<br />
1.75 1.75 2.30 3.20 9.00<br />
1.80 2.40 2.40 2.40 9.00<br />
1.70 2.15 2.15 3.00 9.00<br />
2.25 2.25 2.25 2.25 9.00<br />
Heating<br />
Indoor capacity (kW)<br />
Total<br />
capacity<br />
A B C D (kW)<br />
4.00 - - - 4.00<br />
4.80 - - - 4.80<br />
7.10 - - - 7.10<br />
8.00 - - - 8.00<br />
4.00 4.00 - - 8.00<br />
4.00 4.80 - - 8.80<br />
3.60 6.40 - - 10.00<br />
4.80 4.80 - - 9.60<br />
4.00 6.00 - - 10.00<br />
3.35 6.65 - - 10.00<br />
3.33 3.33 3.33 - 10.00<br />
3.10 3.10 3.80 - 10.00<br />
2.65 2.65 4.70 - 10.00<br />
2.50 2.50 5.00 - 10.00<br />
2.90 3.55 3.55 - 10.00<br />
2.50 3.00 4.50 - 10.00<br />
3.33 3.33 3.33 - 10.00<br />
2.85 2.85 4.30 - 10.00<br />
2.50 2.50 2.50 2.50 10.00<br />
2.40 2.40 2.40 2.80 10.00<br />
2.10 2.10 2.10 3.70 10.00<br />
2.00 2.00 2.00 4.00 10.00<br />
2.25 2.25 2.75 2.75 10.00<br />
2.00 2.00 2.40 3.60 10.00<br />
2.20 2.60 2.60 2.60 10.00<br />
1.95 2.30 2.30 3.45 10.00<br />
2.50 2.50 2.50 2.50 10.00<br />
44
MULTISPLITS DC INVERTER<br />
CONNECTING INFORMATION<br />
DUAL SPLIT<br />
QUADRI-SPLIT<br />
MULTISPLITS SYSTEM<br />
DC INVERTER<br />
R <strong>410</strong> A<br />
Outdoor unit<br />
A<br />
B<br />
Outdoor unit<br />
Ø9.52<br />
B<br />
Ø9.52<br />
A<br />
Ø6.35<br />
Ø6.35<br />
Ø9.52<br />
Ø9.52<br />
Less than 17 m<br />
Ø6.35<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
Indoor unit<br />
Indoor unit<br />
(types 94-184)<br />
(types 94-184)<br />
Outdoor unit<br />
Indoor unit<br />
Ø6.35<br />
A<br />
(types 94-124)<br />
Ø9.52<br />
Ø9.52<br />
Ø6.35<br />
B<br />
(type 184)<br />
Ø9.52<br />
Ø12.7 More than 17 m<br />
Flare Ø9.52 Union Ø12.7<br />
Union Ø12.7 Flare Ø9.52<br />
A joint for connecting tubes of different sizes<br />
(Ø9.52→Ø12.7) Option (STK-34TC)<br />
(Ø12.7→Ø9.52)<br />
Option (STK-43TCA)<br />
(types 94-124)<br />
(type 184)<br />
Outdoor unit<br />
A<br />
Ø9.52<br />
B<br />
Ø9.52<br />
C<br />
Ø9.52<br />
D<br />
Ø12.7<br />
Ø9.52<br />
Flare Ø12.7 Union Ø9.52<br />
(Ø12.7→Ø9.52) Supplied reducer<br />
Outdoor unit<br />
A<br />
Ø9.52<br />
B<br />
Ø9.52<br />
C<br />
Ø9.52<br />
D<br />
Ø12.7<br />
Ø6.35<br />
Ø6.35<br />
Ø6.35<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
Ø12.7<br />
(More than 17 m)<br />
Ø9.52 Ø6.35<br />
Ø6.35<br />
Ø9.52<br />
Ø9.52<br />
Ø6.35<br />
Ø6.35<br />
Ø9.52<br />
Union Ø12.7<br />
Indoor unit<br />
Indoor unit<br />
Flare Ø9.52<br />
(Ø12.7→Ø9.52)<br />
Option (STK-43TCA)<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(type 184)<br />
Outdoor unit<br />
Indoor unit<br />
Ø6.35<br />
A<br />
(types 94-184)<br />
Ø9.52<br />
Ø9.52<br />
Ø6.35<br />
B<br />
(types 94-184)<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
C<br />
(types 94-184)<br />
Ø9.52<br />
Ø9.52<br />
Outdoor unit<br />
Indoor unit<br />
Ø6.35<br />
A<br />
(types 94-124)<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
B<br />
(types 94-124)<br />
Ø9.52<br />
Ø9.52<br />
Ø6.35<br />
C<br />
(type 184)<br />
Ø9.52<br />
Ø12.7 Plus de 17 m<br />
Flare Ø9.52 Union Ø12.7<br />
Union Ø12.7 Flare Ø9.52<br />
A joint for connecting tubes of different sizes<br />
(Ø9.52→Ø12.7) Option (STK-34TC)<br />
(Ø12.7→Ø9.52)<br />
Option (STK-43TCA)<br />
Outdoor unit<br />
A<br />
Ø9.52<br />
B<br />
Ø9.52<br />
C<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
Less than 17 m<br />
TRI-SPLIT<br />
Ø6.35<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
Indoor unit<br />
(types 94-124)<br />
(types 94-124)<br />
(type 184)<br />
Outdoor unit<br />
Ø6.35<br />
A<br />
Ø9.52<br />
Ø9.52<br />
B<br />
Ø9.52<br />
Ø6.35<br />
C<br />
Ø9.52<br />
Ø9.52<br />
Ø6.35<br />
D<br />
Ø12.7<br />
Ø9.52<br />
Flare Ø12.7 Union Ø9.52<br />
(Ø12.7→Ø9.52) Supplied reducer<br />
Outdoor unit<br />
Ø6.35<br />
A<br />
Ø9.52<br />
Ø9.52<br />
B<br />
Ø9.52<br />
Ø6.35<br />
C<br />
Ø9.52<br />
Ø9.52<br />
D<br />
Ø12.7<br />
Ø6.35<br />
Ø9.52<br />
Ø6.35<br />
Ø9.52<br />
Ø6.35<br />
Ø12.7<br />
Indoor unit<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(type 184)<br />
Indoor unit<br />
(types 94-124)<br />
(types 94-124)<br />
(types 94-124)<br />
(type 224)<br />