24.07.2014 Views

SDRIVE - ssdservice.pl

SDRIVE - ssdservice.pl

SDRIVE - ssdservice.pl

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SDRIVE</strong><br />

100 Series<br />

VARIABLE SPEED DRIVE<br />

<strong>SDRIVE</strong> 100 Series, most compact drive, with<br />

exclusive joystick parameter setting system, for<br />

A.C. 230V II motor control.<br />

ELECTRICAL SPECIFICATIONS<br />

Input<br />

Output<br />

Environment conditions<br />

Protections<br />

Control<br />

Voltage sup<strong>pl</strong>y<br />

200 to 230V/AC ±10 single phase<br />

0,4KW - 2,2KW.<br />

Input frequency 50 - 60 Hz. ±5%<br />

Input power factor<br />

> 0,98 (over fundamental frequency)<br />

Momentary power loss<br />

< 15 mS (continuous operation).<br />

> 15 mS (autoreset).<br />

Motor output voltage<br />

0 to input voltage<br />

Current overload capacity<br />

150% during 60sec.<br />

200% during 1 sec.<br />

Frequency range<br />

0 to ±400Hz<br />

Efficiency (full load) > 98%<br />

Modulation method<br />

Vector space modulation<br />

Modulation frequency<br />

15 kHz maximum<br />

Degree of protection<br />

IP20<br />

Operation temperature -10ºC to 50°C<br />

Storage temperature<br />

-20ºC to +65°C<br />

Relative humidity<br />

< 90%, no condensation<br />

Altitude<br />

1000m<br />

Altitude loss factor (>1000m) -1% per 100m; max. 3000m.<br />

Vibration<br />

Max. 5.9m/sec2 (0.6G)<br />

Ap<strong>pl</strong>ication site<br />

Protected from corrosive gas, combustible gas,<br />

oil mist or dust.<br />

Drive trip<br />

Over-voltage.<br />

Under-voltage.<br />

Over-current.<br />

Ground fault current detection.<br />

Over-temperature of inverter and motor.<br />

Output phase open.<br />

Overload.<br />

Communication error.<br />

Loss of frequency command.<br />

H / W fault.<br />

Alarm condition<br />

Stall prevention<br />

Overload<br />

Control method<br />

V /Hz, Vector sensorless<br />

Analogue inputs<br />

1 input 0 - 10Vcc and 1 input 0- 20mA<br />

Digital inputs<br />

5 multifunction inputs<br />

Analogue outputs<br />

1 output 0 - 10V<br />

Digital output<br />

1 multifunction output, open collector.<br />

Relay output<br />

1 fault relay 2A 30Vdc 0.5A 125Vac<br />

Communications port<br />

RS485 and Modbus RTU protocol (as accesory)<br />

Operation features<br />

PID control, 3-wire, up-down operation.<br />

Standards<br />

CE, ISO9001and ISO14000<br />

* For more detailed specifications, refer to user manual.


FWD<br />

REV<br />

RUN<br />

min<br />

100 Series<br />

max<br />

VA RIAB LE S PE ED D RIV E<br />

STOP/RST<br />

FWD<br />

REV<br />

RUN<br />

min<br />

max<br />

1 0 0 Se ries<br />

STOP/RST<br />

VA RIAB LE SP EE D DR IV E<br />

<strong>SDRIVE</strong><br />

100 Series<br />

VARIABLE SPEED DRIVE<br />

CONTROL AND POWER WIRING<br />

P1<br />

FX: Forward run<br />

P2<br />

Multifunction<br />

RX: Reverse run<br />

P3<br />

input terminal BX: Emergency stop<br />

P4<br />

JOG: JOG operation<br />

P5<br />

RST: Fault Reset<br />

FWD<br />

RE V<br />

10K<br />

P24<br />

VR<br />

24V power for P1 - P5<br />

12V power sup<strong>pl</strong>y for potentiometer 10mA<br />

RUN<br />

STOP /RST<br />

V1<br />

0-10V Analog input terminal<br />

I<br />

0-20mA Analog input terminal<br />

min<br />

m ax<br />

CM<br />

0V common terminal for P1-P5, AM, P24<br />

AM<br />

0-10V Multi-function analog output terminal<br />

NP N<br />

P NP P4 P5 VR V1 C M I AM<br />

30A 30B 30C MO EXTG P24 P1 P2 CM P3<br />

L 1 N + + 1 _<br />

U V W<br />

Motor<br />

200 - 230V<br />

CM<br />

MO<br />

EXTG<br />

30A Fault Relay<br />

2A 30 Vdc<br />

30B<br />

0.5A 125Vac<br />

30C<br />

L1<br />

N<br />

+<br />

+1<br />

_<br />

U<br />

V<br />

W<br />

G<br />

0V common terminal for AM terminal<br />

Multi-function open collector output ??24Vdc 50mA.<br />

Ground T/M for MO<br />

AC line<br />

voltage input<br />

Terminal for<br />

inverter<br />

DC P/S<br />

Motor<br />

Ground<br />

Open<br />

Closed<br />

30A and 30B common<br />

L1<br />

N<br />

Filter EMI<br />

Class B<br />

+ +1<br />

_<br />

U<br />

V<br />

W<br />

DIMMENSIONS AND STANDARD RATINGS<br />

REFERENCE<br />

Dimmensions Weight<br />

H W D (Kg)<br />

SD1103 79 143 143 0.87<br />

SD1103F 79 143 143 0.95<br />

SD1105 79 143 143 0.89<br />

SD1105F 79 143 143 0.97<br />

SD1108 156 143 143 1.79<br />

SD1108F 156 143 143 1.94<br />

SD1112 156 143 143 1.85<br />

SD1112F 156 143 143 2<br />

<strong>SDRIVE</strong><br />

WARNING<br />

79<br />

143<br />

1 56<br />

<strong>SDRIVE</strong><br />

WARNING<br />

REFERENCE I (A) KW HP<br />

V<br />

SD1103 3 0,55 0,75 230II<br />

SD1103F 3 0,55 0,75 230II<br />

SD1105 5 1,1 1,5 230II<br />

SD1105F 5 1,1 1,5 230II<br />

SD1108 8 2,2 3 230II<br />

SD1108F 8 2,2 3 230II<br />

SD1112 12 3 4 230II<br />

SD1112F 12 3 4 230II<br />

* Filters RFI industrial environmental.<br />

POWER ELECTRONICS ESPAÑA<br />

Leonardo da Vinci, 24-26 · Parque Tecnológico · 46980 · PATERNA · VALENCIA · ESPAÑA · Tel. (+34) 96 136 65 57 · Fax. (+34) 96 131 82 01 · www.power-electronics.com<br />

POWER ELECTRONICS DEUTSCHLAND Gmbh<br />

Conradtystrasse, 41 · 90441 · N ÜRNBERG · DEUTSCHLAND · Tel. (+49) 911 99 43 990 · Fax. (+49) 911 99 43 999 · www.ped-gmbh.de