11.09.2014 Views

PDF Download - Glidewell Dental Labs

PDF Download - Glidewell Dental Labs

PDF Download - Glidewell Dental Labs

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Inclusive®<br />

Restorative Driven Implant Solutions Vol. 2, Issue 3<br />

A Multimedia Publication of <strong>Glidewell</strong> Laboratories • www.inclusivemagazine.com<br />

Missed Diagnosis Using<br />

2-D Radiography<br />

Dr. Daniel McEowen<br />

Page 14<br />

Implant Q&A:<br />

gIDE’s Dr. Sascha<br />

Jovanovic<br />

Page 18<br />

Digital Treatment Planning<br />

and Mini Implants<br />

Dr. Paresh Patel<br />

Page 25<br />

2.69 mm<br />

4.09 mm<br />

Preserving Facial<br />

Structure with Implant<br />

Overdentures<br />

Dr. Timothy Kosinski<br />

Page 48<br />

1.63 mm<br />

4.36 mm<br />

CAD/CAM Implant Abutment Design<br />

Dr. Bradley Bockhorst and<br />

Dzevad Ceranic, CDT<br />

Page 6


On the Web<br />

Here’s a sneak peek at the additional<br />

Inclusive magazine content available online.<br />

ONLINE Video Presentations<br />

• <strong>Glidewell</strong> Laboratories’ Alec Di Lullo demonstrates how the latest<br />

CAD/CAM technology is used in the custom design of implant<br />

abutments.<br />

• gIDE academic chairman Dr. Sascha Jovanovic answers questions<br />

pertaining to the stability of implants and the health of their surrounding<br />

tissues.<br />

• Dr. Daniel McEowen summarizes the limitations of 2-D radiography<br />

when compared to 3-D CBCT imaging technology.<br />

• Dr. Paresh Patel performs a guided surgical procedure in which<br />

Inclusive ® Mini Implants are placed in the upper and lower<br />

arches of an edentulous patient.<br />

• Dr. Timothy Kosinski gives his rationale for determining the<br />

appropriate implant and attachment options for overdenture<br />

patients.<br />

Check out the latest online issue of Inclusive<br />

magazine at www.inclusivemagazine.com.<br />

• Dr. Ara Nazarian highlights the intermediate and long-term<br />

benefits of utilizing BioTemps ® Implant Provisionals.<br />

ONLINE CE credit<br />

• Get free CE credit for the material in this issue with each test you<br />

complete and pass. To get started, visit our website and look for<br />

the articles marked with “CE.”<br />

Look for these icons in the pages that follow for extra content<br />

available on our website, www.inclusivemagazine.com.<br />

– www.inclusivemagazine.com –


Contents<br />

ALSO IN THIS ISSUE<br />

32 Clinical Tip: <strong>Dental</strong> Photography as<br />

a Laboratory Communication Tool<br />

36 A New Generation of Denture Teeth:<br />

The Perfect Route to Esthetic and<br />

Functional Dentures<br />

43 Ensuring a Successful Restorative<br />

Outcome Utilizing BioTemps ®<br />

Implant Provisionals<br />

6<br />

14<br />

18<br />

25<br />

48<br />

CAD/CAM Technology in Implant Abutment Design<br />

Implant abutments custom-designed and milled with today’s digital<br />

CAD/CAM techniques offer several clinical advantages over prefabricated<br />

abutments. Utilizing anterior and posterior case examples,<br />

<strong>Glidewell</strong> Laboratories’ Dr. Bradley Bockhorst and Dzevad Ceranic,<br />

CDT, discuss the parameters for ensuring proper margins, angle<br />

correction, crown support, emergence profile and more.<br />

Missed Diagnosis Using Conventional Radiography<br />

With the ability to capture three-dimensional views in multiplanar<br />

slices, Cone Beam Computed Tomography (CBCT) is proving superior<br />

to conventional radiography in the evaluation of endodontic<br />

anatomy and dental disease. In a case report, Dr. Daniel McEowen<br />

details a situation in which this advanced imaging technology enabled<br />

him to accurately diagnose an endodontic failure, and to plan<br />

treatment involving immediate, post-extraction implant placement.<br />

Implant Q&A: An Interview with Dr. Sascha Jovanovic<br />

In an Inclusive magazine interview, gIDE founder and academic<br />

chairman Dr. Sascha Jovanovic shares his thoughts on a variety of<br />

implant-related topics. Read what this leading clinician and lecturer<br />

on implant surgery and soft tissue health and esthetics has to say<br />

about some of the many considerations regarding implant therapy.<br />

Three-Dimensional Treatment Planning with Surgical<br />

Guides and Mini Implant-Retained Dentures<br />

To meet the challenge of an edentulous case contraindicating conventional<br />

implant treatment, Dr. Paresh Patel utilizes cutting-edge<br />

digital treatment planning and resulting surgical guides to ensure<br />

the flapless, parallel insertion of mini implants for the retention of<br />

maxillary and mandibular overdentures.<br />

Preserving the Integrity of Facial Structures with<br />

Implant-Retained Overdentures<br />

Bone resorption resulting from edentulism can compromise a person’s<br />

features by allowing a collapse of facial structures. While<br />

conventional dentures may help, they are often unstable and do<br />

nothing to prevent future bone loss. Here, Dr. Timothy Kosinski<br />

describes how dental implant services have been shown to minimize<br />

resorption, thereby maintaining the natural appearance of the face<br />

and smile while improving denture comfort and stability.<br />

– Contents – 1


Letter from the Editor<br />

There are many new dental technologies available today that clinicians can utilize to provide a higher quality of care for<br />

their patients; however, understanding the benefits, proper use and limitations of these technologies is paramount to their<br />

successful application. This issue of Inclusive showcases several of these innovations, ranging from digital treatment planning<br />

and Cone Beam Computed Tomography (CBCT) to CAD/CAM implant abutment design and fabrication.<br />

When placing small-diameter implants, a flapless surgical procedure is often used. In a case report, Dr. Paresh Patel utilizes<br />

a CBCT scan, treatment planning software and guided surgery to plan and place mini implants in a patient with severely<br />

atrophic ridges. Another application of 3-D imaging allows Dr. Daniel McEowen to correctly diagnose the previously undetected<br />

cause of an endodontic failure, which leads to immediate post-extraction implant placement.<br />

CAD/CAM is one of the fastest-growing sectors in dentistry today. This technology enables the dental laboratory to create<br />

custom solutions for your implant cases. Supplementing this issue’s article on the subject (page 6), our online version includes<br />

a step-by-step tutorial presented by <strong>Glidewell</strong> Laboratories’ Alec Di Lullo demonstrating how this technology is used<br />

in implant abutment design. Understanding the functionality of this software will allow you to direct the lab to provide your<br />

patients with the best possible restorations.<br />

There have also been technological improvements in dental materials. Nobel Biocare’s classic Brånemark System ® hybrid<br />

denture has been around for more than 40 years, and with the introduction of CAD/CAM milled titanium frameworks,<br />

the screw-retained denture is still a standard implant restoration. One of the challenges with this type of prosthesis is the<br />

inevitable wear of the denture teeth and loss of VDO. An article by Thorsten Michel, MDT, details the development of Ivoclar<br />

Vivadent’s SR Phonares ® nano-hybrid composite denture teeth, which offer improved strength and esthetics.<br />

While conventional dentures can provide missing facial support, they are often unstable and do nothing to prevent future<br />

bone loss. Dr. Timothy Kosinski describes how implants have been shown to minimize resorption while providing greater<br />

comfort and stability for denture wearers. Case examples illustrate the decision process for selecting various types of overdentures,<br />

including freestanding attachments, bars and mini implants.<br />

Our featured interview is with Dr. Sascha Jovanovic, a leading clinician and educator on implant esthetics. He shares his<br />

thoughts on the latest implant designs and grafting procedures. Of related concern is the sculpting of the soft tissues, which<br />

can be effectively contoured by a quality temporary restoration. Dr. Ara Nazarian demonstrates this and other benefits of<br />

BioTemps ® in provisionalizing implant cases.<br />

We are also proud to announce the opening of the <strong>Glidewell</strong> International Technology Center. A primary goal of this<br />

state-of-the-art facility is to educate clinicians on the latest dental technologies, including how to smoothly integrate them<br />

into their practice. For information about upcoming courses, visit www.glidewellce.com.<br />

Dr. Bradley C. Bockhorst<br />

Editor-in-Chief, Clinical Editor<br />

inclusivemagazine@glidewelldental.com<br />

– Letter from the Editor – 3


Publisher<br />

Jim <strong>Glidewell</strong>, CDT<br />

Editor-in-Chief and clinical editor<br />

Bradley C. Bockhorst, DMD<br />

Managing Editors<br />

Jim Shuck; Mike Cash, CDT<br />

Creative Director<br />

Rachel Pacillas<br />

Contributing editors<br />

David Casper; Dzevad Ceranic, CDT;<br />

Greg Minzenmayer<br />

copy editors<br />

Jennifer Holstein, Eldon Thompson<br />

digital marketing manager<br />

Kevin Keithley<br />

Graphic Designers/Web Designers<br />

Jamie Austin, Deb Evans, Joel Guerra, Audrey Kame,<br />

Lindsey Lauria, Phil Nguyen, Kelley Pelton, Ty Tran<br />

Photographers/Clinical Videographers<br />

Sharon Dowd, James Kwasniewski, Sterling Wright<br />

Illustrator<br />

Phil Nguyen<br />

coordinatorS/AD Representatives<br />

Teri Arthur, Vivian Tsang<br />

If you have questions, comments or suggestions, e-mail us at<br />

inclusivemagazine@glidewelldental.com. Your comments may<br />

be featured in an upcoming issue or on our website.<br />

© 2011 <strong>Glidewell</strong> Laboratories<br />

Neither Inclusive magazine nor any employees involved in its publication<br />

(“publisher”) makes any warranty, express or implied, or assumes<br />

any liability or responsibility for the accuracy, completeness, or usefulness<br />

of any information, apparatus, product, or process disclosed, or<br />

represents that its use would not infringe proprietary rights. Reference<br />

herein to any specific commercial products, process, or services by<br />

trade name, trademark, manufacturer or otherwise does not necessarily<br />

constitute or imply its endorsement, recommendation, or favoring<br />

by the publisher. The views and opinions of authors expressed<br />

herein do not necessarily state or reflect those of the publisher and<br />

shall not be used for advertising or product endorsement purposes.<br />

CAUTION: When viewing the techniques, procedures, theories and<br />

materials that are presented, you must make your own decisions<br />

about specific treatment for patients and exercise personal professional<br />

judgment regarding the need for further clinical testing or education<br />

and your own clinical expertise before trying to implement new<br />

procedures.<br />

Inclusive is a registered trademark of <strong>Glidewell</strong> Laboratories.<br />

Contributors<br />

■ Bradley C. Bockhorst, DMD<br />

After receiving his dental degree from Washington<br />

University School of <strong>Dental</strong> Medicine,<br />

Dr. Bradley Bockhorst served as a Navy <strong>Dental</strong><br />

Officer. Dr. Bockhorst is director of clinical technologies<br />

at <strong>Glidewell</strong> Laboratories, where he<br />

oversees Inclusive ® Digital Implant Treatment<br />

Planning services and is editor-in-chief and<br />

clinical editor of Inclusive magazine. A member of the CDA,<br />

ADA, AO, ICOI and AAID, Dr. Bockhorst lectures internationally<br />

on an array of dental implant topics. Contact him at<br />

800-521-0576 or inclusivemagazine@glidewelldental.com.<br />

■ Dzevad Ceranic, CDT<br />

Dzevad Ceranic began his career at <strong>Glidewell</strong><br />

Laboratories while attending Pasadena<br />

City College’s dental laboratory technology<br />

program. In 1999, Dzevad began working at<br />

<strong>Glidewell</strong> as a waxer and metal finisher, and<br />

soon worked his way up to ceramist. With the<br />

skills acquired as a dental technician, he was<br />

promoted to GM of the Full-Cast department. In this role, he<br />

assisted in facilitating the lab’s transition to CAD/CAM. In 2008,<br />

he took on the company’s rapidly growing Implant department.<br />

Dzevad completed an implants course at UCLA School of Dentistry<br />

in 2009. Today, he leads a team of 170 people at the lab,<br />

implementing cutting-edge technology throughout his department.<br />

Contact him at inclusivemagazine@glidewelldental.com.<br />

■ SASCHA A. JOVANOVIC, DDS, MS<br />

Dr. Sascha Jovanovic received his training in<br />

periodontics, implant dentistry and prosthodontics<br />

at UCLA School of Dentistry, Loma<br />

Linda University and University of Aachen<br />

in Germany, respectively, and holds an M.S.<br />

in oral biology from UCLA. Founder and<br />

academic chairman of the Global Institute<br />

for <strong>Dental</strong> Education (gIDE) and course director of implant<br />

dentistry for UCLA Continuing <strong>Dental</strong> Education, he<br />

has dedicated his clinical work for more than 15 years to<br />

dental implant therapy and bone and soft tissue reconstruction.<br />

He is past president of the European Association for<br />

Osseointegration, past board member of the Osseointegration<br />

Foundation and the recipient of many dental industry awards.<br />

He also lectures and publishes extensively. Contact him at<br />

310-820-9641 or sascha@jovanoviconline.com.<br />

4<br />

– www.inclusivemagazine.com –


■ TIMOTHY F. KOSINSKI, DDS, MAGD<br />

Dr. Timothy Kosinski graduated from University<br />

of Detroit Mercy School of Dentistry and<br />

received a Master of Science degree in biochemistry<br />

from Wayne State University School<br />

of Medicine. An adjunct assistant professor<br />

at Mercy School of Dentistry, he serves on the<br />

editorial review board of numerous dental<br />

journals and is a Diplomate of the ABOI/ID, ICOI and AO.<br />

Dr. Kosinski is a Fellow of the AAID and received his Mastership<br />

in the AGD, from which he received the 2009 Lifelong Learning<br />

and Service Recognition award. Contact him at 248-646-8651,<br />

drkosin@aol.com or www.smilecreator.net.<br />

■ FRANK LAUCIELLO, DDS<br />

Dr. Frank Lauciello graduated from SUNY at<br />

Buffalo School of <strong>Dental</strong> Medicine in 1969<br />

and completed his prosthodontic training at<br />

Buffalo VA Medical Center. Currently a clinical<br />

associate professor in the restorative department<br />

at SUNY at Buffalo, he was director<br />

of the Veterans Administration advanced<br />

program in prosthodontics from 1973 to 1998 and chief of<br />

the dental service from 1996 to 1998. He is also director of<br />

removable prosthodontics for Ivoclar Vivadent and director<br />

of its Implant Esthetics Center of Excellence in Sarasota, Fla.<br />

A Diplomate of the American Board of Prosthodontics, he<br />

has authored numerous articles and textbook chapters and is<br />

actively involved in dental research and product development.<br />

Contact him at frank.lauciello@ivoclarvivadent.com.<br />

■ Thorsten Michel, MDT<br />

Thorsten Michel completed his dental technician<br />

training in 1991 at Mangold dental lab<br />

in Stuttgart, Germany, during which time he<br />

was awarded the prestigious Gysi Prize. After<br />

a stint in the German armed forces, Thorsten<br />

worked for Albrecht Schenk dental lab in<br />

Schwäbisch Gmünd from 1992 to 1994,<br />

and then Winnenden-based Jürgen Dieterich until 1998.<br />

In 2000, he completed master dental technician school in<br />

Freiburg/Breisgau, earning best performance in the examination<br />

for the master craftsman’s diploma. In 2001, he received<br />

the Klaus Kanter award. He currently runs his own dental lab<br />

in Schorndorf, which he started in June 2000. Contact him at<br />

info@michel-zahntechnik.de.<br />

■ ARA NAZARIAN, DDS, DICOI<br />

Dr. Ara Nazarian maintains a private practice<br />

in Troy, Mich., with an emphasis on comprehensive<br />

and restorative care. He is the director<br />

of the Reconstructive Dentistry Institute,<br />

a Diplomate of the ICOI, and has conducted<br />

lectures and hands-on workshops on esthetic<br />

materials and dental implants throughout<br />

the U.S., Europe, New Zealand and Australia. Dr. Nazarian<br />

is also the creator of the DemoDent patient education model<br />

system. His articles have been published in many of today’s<br />

popular dental publications. Contact him at 248-457-0500 or<br />

www.aranazariandds.com.<br />

■ Daniel McEowen, DDS<br />

Dr. Daniel McEowen is a 1982 graduate of<br />

Loma Linda University School of Dentistry and<br />

has been in private practice for 26 years. He<br />

currently practices in Hagerstown, Md., in a<br />

multidiscipline practice. A founding member<br />

and Master of the World Clinical Laser Institute<br />

(WCLI), he lectures and trains internationally<br />

in laser dentistry techniques, and teaches a course for erbium<br />

and diode lasers with the Masters of Laser Dentistry. He has<br />

been active in obtaining FDA approval of oral surgery techniques<br />

using erbium lasers. Dr. McEowen also owns 3D<br />

Imaging Center in Maryland, lectures throughout the U.S. on<br />

cone beam technology, and is an advanced trainer for PreXion<br />

3D cone beam systems. He is active in implantology and a<br />

member of the ICOI. Contact him at drdan13106@gmail.com.<br />

■ Paresh B. PATEL, DDS<br />

Dr. Paresh Patel is a graduate of University of<br />

North Carolina at Chapel Hill School of Dentistry<br />

who has been practicing since 1996. He<br />

has a passion for keeping up with the changing<br />

technology and materials in dentistry. As<br />

a Master in the International Academy of Mini<br />

<strong>Dental</strong> Implants (IAMDI), he has placed more<br />

than 2,500 mini implants and has worked as a lecturer and<br />

clinical consultant on mini implants for various companies.<br />

Dr. Patel belongs to numerous dental organizations, including<br />

the ADA, North Carolina <strong>Dental</strong> Society and AACD, and<br />

is also a member and president of the Iredell County <strong>Dental</strong><br />

Society in Mooresville, N.C. Contact him at 704-799-0552 or<br />

pareshpateldds2@gmail.com.<br />

– Contributors – 5


CAD/CAM Technology in<br />

Implant Abutment Design<br />

Go online for<br />

in-depth content<br />

by Bradley C. Bockhorst, DMD and<br />

Dzevad Ceranic, CDT<br />

Custom abutments provide<br />

numerous clinical advantages<br />

over prefabricated<br />

abutments. Utilizing CAD/CAM<br />

technology, the dental technician<br />

can precisely design and<br />

fabricate the restoration according<br />

to the clinician’s prescription.<br />

Modifications can be made<br />

to the transgingival section,<br />

the margin and the angle of<br />

the abutment. The base, height<br />

and taper of the abutment can<br />

also be designed to provide<br />

support and retention for the<br />

crown. This article will discuss<br />

the clinical parameters that must<br />

be considered when designing<br />

an implant abutment. Anterior<br />

and posterior case examples<br />

handled at <strong>Glidewell</strong> Laboratories<br />

(Newport Beach, Calif.) will<br />

illustrate the primary features<br />

that can be designed into an<br />

abutment using computer-aided<br />

technology.<br />

6<br />

– www.inclusivemagazine.com –


■ The Transgingival Section<br />

Various designs have been used over the years for the section<br />

of the abutment extending from the top of the implant<br />

through the soft tissue. Early root-form endosseous implant<br />

systems advocated a straight-walled design through the gingiva.<br />

1,2 However, this resulted in ridge-lap crown designs<br />

that presented hygienic and esthetic challenges.<br />

Inclusive ® Custom<br />

Implant Abutments<br />

In the 1990s, abutment systems were introduced to create<br />

an “emergence profile.” 3–6 In this scenario, the base of the<br />

abutment flares as it rises coronally from the top of the<br />

implant. The premise of this design is that the restoration<br />

emerges through the soft tissue in a similar way to the natural<br />

clinical crown. While providing an esthetic, cleansable<br />

result, this design requires that clinical precautions be taken<br />

to avoid excessive pressure on the labial tissue, which can<br />

lead to recession. 7<br />

Research has been conducted and some products brought<br />

to market with concave transgingival sections. 8 The concept<br />

behind this design is that creating a thicker band of gingiva<br />

around the abutment will stabilize the soft tissue and mask<br />

the gray color of the titanium abutment at the gingival margin.<br />

A potential challenge with this design is that removing<br />

or replacing the abutment would likely necessitate anesthetizing<br />

of the patient. The narrow neck design could also<br />

lead to thin, potentially weak abutment walls.<br />

So is the best transgingival design straight, convex or concave?<br />

The appropriate solution depends on the case. If the<br />

patient’s soft tissue is thin, the abutment may need to flare<br />

out beginning at the top of the implant. Interproximally, the<br />

abutment can be designed to provide support for the papillae.<br />

If the patient’s soft tissue is thicker, the abutment can be<br />

straight or only slightly flared at the top of the implant and<br />

begin flaring just below the crest of the soft tissue.<br />

<strong>Glidewell</strong> Laboratories offers three types of customized<br />

implant abutments under the Inclusive brand<br />

name: a titanium abutment, a zirconia abutment and<br />

a zirconia to titanium hybrid. Titanium abutments are<br />

used in all areas of the mouth, while zirconia abutments<br />

offer an esthetic option for anterior cases,<br />

particularly if the patient has a thin biotype. The zirconia<br />

hybrid abutment provides a titanium-to-titanium<br />

interface with the implant, as well as a deeper<br />

abutment-to-implant interface. For this hybrid abutment,<br />

an anatomically correct zirconia structure is<br />

luted to a titanium insert in the laboratory using resin<br />

cement.<br />

Utilizing CAD/CAM technology,<br />

the dental technician can<br />

precisely design and fabricate<br />

the restoration according<br />

to the clinician’s prescription.<br />

– CAD/CAM Technology in Implant Abutment Design – 7


So is the best transgingival<br />

design straight, convex or<br />

concave? The appropriate<br />

solution depends on the case.<br />

When seating the abutment, a critical factor is what is placed<br />

on the implant. A properly fabricated provisional restoration<br />

is ideal to help shape and sculpt the soft tissue contours. If<br />

a stock healing abutment is chosen, one with a flare similar<br />

to the tooth being replaced should be used. The soft tissue<br />

and/or the abutment should be adjusted if blanching occurs<br />

upon delivery and does not dissipate within 10 minutes, as<br />

excessive pressure on the tissue can lead to recession. A<br />

periapical radiograph should be taken to verify complete<br />

seating of the abutment.<br />

■ Setting the Margin<br />

For cemented implant restorations, the location of the<br />

margin is even more critical than on natural preps. Several<br />

studies have emphasized the detrimental effect of excess<br />

cement on peri-implant bone and soft tissue. 9,10 Using a<br />

scan of the model, the margin can be set approximately<br />

1 mm below the crest of the soft tissue in esthetic areas.<br />

Typically, it will be placed at or 0.5 mm below the crest<br />

interproximally and lingually/palatally, which provides an<br />

esthetic result and easy access for the complete removal<br />

of excess cement. The shoulder of the margin can also be<br />

planned based on the intended crown type.<br />

■ Crown Support and Retention<br />

Virtual design of the abutment allows the technician to create<br />

the ideal base to support the crown. Retention of the<br />

crown is based on the height and taper of the abutment. 12<br />

CAD software allows the abutment and crown to be visualized<br />

to determine the optimal abutment base width and<br />

height. A six-degree taper is typically provided for retention.<br />

The height of the abutment should be maximized, with<br />

consideration given to providing adequate occlusal/incisal<br />

space for the crown. Finally, the cement space for the crown<br />

can be precisely adjusted.<br />

Using a scan of the model, the<br />

margin can be set ... which<br />

provides an esthetic result and<br />

easy access for the complete<br />

removal of excess cement.<br />

■ Anterior Case Example<br />

■ Angle Correction<br />

If the trajectory of the implant diverges from the position<br />

of the crown of the tooth to be replaced, the abutment can<br />

be designed to correct this angle. 11 Custom abutments can<br />

be manufactured to correct divergence; however, it is not<br />

recommended to exceed 20 degrees of angle correction.<br />

From a biomechanical perspective, severe angles should be<br />

avoided and worked out during the planning stage. Off-axis<br />

loading, particularly in single-tooth restorations, should be<br />

avoided or minimized as much as possible.<br />

Figure 1: Using 3Shape CAD software, the margin of the abutment is set following<br />

the gingival contours. The grid can be used as a measurement aid. The transgingival<br />

section of the abutment fills the sulcus and creates the base for the restoration.<br />

NOTE: <strong>Glidewell</strong> Laboratories will virtually blanch the tissue no more than<br />

0.5 mm, unless specified otherwise on the lab prescription.<br />

8<br />

– www.inclusivemagazine.com –


Figure 2: A full-contour crown is placed over the abutment and the interproximal<br />

contacts are adjusted. Because implants have no periodontal ligament and<br />

therefore no give, long, broad, light interproximal contacts are designed. Once the<br />

crown is designed, the supragingival section of the abutment is adjusted to create<br />

adequate space, support and retention for the restoration.<br />

CAD software allows the<br />

abutment and crown to<br />

be visualized to determine<br />

the optimal abutment base<br />

width and height.<br />

Figure 3: The height of the abutment is adjusted in relation to the crown.<br />

Figure 5: Adjustments are made to the palatal contours.<br />

Figure 4: The mesial-distal width of the abutment is adjusted.<br />

Figure 6: The labial contours and spacing are adjusted.<br />

– CAD/CAM Technology in Implant Abutment Design – 9


■ Posterior Case Example<br />

Figure 7: Incisal view of the abutment with screw access opening and crown<br />

Figure 1: Using the same CAD software as in the previous case, the margin and<br />

transgingival section are set.<br />

Figure 8: Cross-sectional view of the abutment and crown<br />

Figure 2: A full-contour crown is placed over the abutment, and the occlusal and<br />

interproximal contacts are adjusted (red circles).<br />

Once the crown is<br />

designed, the supragingival<br />

section of the abutment is<br />

adjusted to create adequate<br />

space, support and retention<br />

for the restoration.<br />

Figure 3: The height and taper of the abutment is adjusted.<br />

10<br />

– www.inclusivemagazine.com –


■ Conclusion<br />

The use of CAD/CAM technology to design and fabricate<br />

custom abutments provides numerous clinical advantages.<br />

This method allows the clinician to specify design criteria<br />

and material choice on the lab prescription. The abutment<br />

is then custom-designed for the specific case and precisionmilled,<br />

resulting in a superior restoration.<br />

■ References<br />

Figure 4: Adjustments are made to the labial, lingual/palatal and interproximal<br />

contours.<br />

1. Adell R, Eriksson B, Lekholm U, Brånemark PI, Jemt T. Long-term follow-up study<br />

of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral<br />

Maxillofac Implants. 1990;5(4):347–59.<br />

2. Spiekermann H, Jansen VK, Richter EJ. A 10-year follow-up study of IMZ and TPS<br />

implants in the edentulous mandible using bar-retained overdentures. Int J Oral<br />

Maxillofac Implants. 1995 Mar-Apr;10(2):231–43.<br />

3. Daftary F. Dentoalveolar morphology: evaluation of natural root form versus cylindrical<br />

implant fixtures. Pract Periodontics Aesthet Dent. 1997 May;9(4):469–77;<br />

quiz 478.<br />

4.King KO. Implant abutment emergence profile: key to esthetics. J Oral Implantol.<br />

1996;22(1):27–30.<br />

5. Lazzara R. Esthetic excellence with implant abutments. Dent Econ. 1993 Mar;<br />

83(3):83–4, 89.<br />

6. Salinas TJ, Sadan A. Establishing soft tissue integration with natural tooth-shaped<br />

abutments. Pract Periodontics Aesthet Dent. 1998 Jan-Feb;10(1):35–42; quiz 44.<br />

7. Su H, Gonzalez-Martin O, Weisgold A, Lee E. Considerations of implant abutment<br />

and crown contour: critical contour and subcritical contour. Int J Periodontics<br />

Restorative Dent. 2010 Aug;30(4):335–43.<br />

8. Redemagni M, Cremonesi S, Garlini G, Maiorana C. Soft tissue stability with<br />

immediate implants and concave abutments. Eur J Esthet Dent. 2009 Winter;<br />

4(4):328-37.<br />

9. Chik FF, Chan WK, Pow EHN, Chow TW. Management of non-restorable maxillary<br />

premolars with immediate implants, immediate provisional restorations, and<br />

definitive screw-retained CAD/CAM zirconia abutment crowns: a report of five<br />

cases. Hong Kong Dent J. 2009;6:31–8.<br />

10. Goodacre CJ, Bernal GB, Rungcharassaeng K. Clinical complications with<br />

implants and implant prostheses. J Prosthet Dent. 2003;90:121–32.<br />

11. Wu T, Liao W, Dai N, Tang C. Design of a custom angled abutment for dental<br />

implants using computer-aided design and nonlinear finite element analysis.<br />

J Biomech. 2010 Jul 20;43(10):1941–46.<br />

12. Emms M, Tredwin CJ, Setchell DJ, Moles DR. The effects of abutment wall height,<br />

platform size, and screw access channel filling method on resistance to dislodgement<br />

of cement-retained, implant-supported restorations. J Prosthodont.<br />

2007 Jan-Feb;16(1):3–9.<br />

Figure 5: Once the abutment design is completed, the file is transferred to a 5-axis<br />

milling machine and the abutment is fabricated.<br />

– CAD/CAM Technology in Implant Abutment Design – 11


Chairside Processing of LOCATOR ® Attachments into an Existing Denture<br />

Introduced in 2001, the Locator Attachment is the third generation of attachments from Zest Anchors and the worldwide<br />

standard for overdenture retention. A common clinical indication for Locator Attachments is the retrofit of an existing<br />

overdenture. This can easily be accomplished by any clinician and is a great treatment plan that introduces implant<br />

retention to the neediest patients.<br />

Case presentation by John C. Bain, DDS, Farmington, Ark.<br />

Step 1: Remove healing abutments<br />

and place the appropriate<br />

Locator Abutment, ensuring the<br />

top 1.5 mm of the abutment remains<br />

above the gingival tissue.<br />

Step 2: Hand-tighten into place,<br />

and then torque to 30 Ncm or to<br />

the value recommended for the<br />

specific implant system (as documented<br />

in the system's IFU).<br />

Step 3: Place block-out ring over<br />

the Locator Abutment. This will<br />

prevent acrylic resin from flowing<br />

into any exposed undercut<br />

area, facilitating removal of the<br />

denture once the material is set.<br />

Step 4: Insert the Black Processing<br />

Male in the Locator<br />

Denture Cap and place on the<br />

abutment in the mouth.<br />

Step 5: Place indicator paste<br />

on the denture to coincide with<br />

the location of the Locator Abutments<br />

in the mouth.<br />

Step 6: Using an acrylic bur,<br />

relieve the denture in the areas<br />

where the denture caps will rest.<br />

Minimal relief is recommended,<br />

followed by repeated intraoral<br />

verification to ensure the residual<br />

integrity of the denture base.<br />

Step 7: Clean the receptor sites<br />

with alcohol to ensure the removal<br />

of any residual material.<br />

Step 8: Apply resin-curing primer<br />

and bonding agent to the denture<br />

receptor sites.<br />

Step 9: Fill each receptor site<br />

with light-cure acrylic resin.<br />

Step 10: Dry the denture caps<br />

and apply resin-curing primer<br />

and bonding agent. Next, apply<br />

light-cure resin.<br />

Step 11: Seat the denture back<br />

in the mouth and confirm proper<br />

occlusion. Light-cure the denture<br />

in the areas of the Locator<br />

Denture Caps.<br />

Step 12: Remove the denture<br />

and inspect for any voids. If<br />

necessary, fill any voids and<br />

then final-cure the denture for<br />

an additional one minute.<br />

Step 13: Remove the Black Processing<br />

Males using the Locator<br />

Core Tool and insert the appropriate<br />

final male components.<br />

“The Locator Implant Attachment is our attachment<br />

of choice. We like its versatility and the<br />

availability of abutments for any implant system<br />

we use. Our patients can immediately insert and<br />

remove their overdentures with little instruction,<br />

making them very happy and saving us a great<br />

deal of chairtime.”<br />

– Robert L. Blackwell, DDS , Alton, Ill.<br />

“I have been using Locator Attachments to<br />

restore my patients for over 10 years. The<br />

precision, predictability and durability of the<br />

attachments have been outstanding. The fact<br />

that I rarely need to replace the males has<br />

increased my productivity and profitability. Locator<br />

has truly improved my patients’ quality of life."<br />

– Robert C. Vogel, DDS,<br />

Palm Beach Gardens, Fla.


Missed Diagnosis Using Conventional<br />

2-D Radiography<br />

Go online for<br />

in-depth content<br />

by Daniel McEowen, DDS<br />

Cone Beam Computed Tomography (CBCT) is<br />

becoming increasingly popular in dentistry for<br />

diagnosis and treatment planning. Use of this three-dimensional<br />

imaging technology can increase diagnostic accuracy compared<br />

to conventional two-dimensional digital periapical and panoramic<br />

radiography. The inherent distortions and limitations<br />

of 2-D radiographs make it much more difficult to complete<br />

an accurate case diagnosis. Some of these limitations include:<br />

elongation and foreshortening of the target tissues, overlap of<br />

structures in front of or behind the target tissues, tissue density<br />

that is not easily interpreted in bone or soft tissues, and resolution<br />

differences of various film and digital receptors.<br />

Many of the issues associated with conventional 2-D radiography<br />

can be eliminated or greatly reduced with the use of 3-D<br />

CBCT. CBCT uses a cone-shaped beam and digital processing to<br />

create a 3-D image that does not contain magnification, distortion<br />

and overlap of anatomy. Before investing in 3-D imaging, a<br />

clinician will need to choose a “field of view” (FOV). FOV refers<br />

to the area of the anatomy that is captured by the scan. Medium<br />

FOV CBCT scanners offer focal spot sizes down to 0.15 mm<br />

and voxel sizes down to 0.076 mm. The size of the focal spot<br />

and each voxel (volume pixel) determines the resolution of the<br />

image; the smaller the focal spot and voxel, the better the resolution.<br />

1,2 Smaller focal spot sizes and higher resolution enable<br />

clinicians to make very accurate diagnoses in most cases. CBCT<br />

also offers multiplanar views (MPV) in slices as thin as 0.05<br />

mm thick. These MPV are cross sections through the volume of<br />

information in axial (x-z axes), coronal (x-y axes) and saggital<br />

(z-y axes) views. Using sophisticated software, the volume can<br />

be sliced at any oblique direction to view pathology from virtually<br />

any angle and thickness. The ability to view diseased areas<br />

in different planes can eliminate guesswork during diagnosis<br />

and help determine the least invasive procedure necessary to<br />

eliminate the dental disease.<br />

Use of threedimensional<br />

imaging<br />

technology can<br />

increase diagnostic<br />

accuracy compared<br />

to conventional<br />

two-dimensional<br />

digital periapical<br />

and panoramic<br />

radiography.<br />

The following case study illustrates how using CBCT technology<br />

can improve the success of endodontic diagnosis and treatment.<br />

14<br />

– www.inclusivemagazine.com –


Figure 1: Pre-endodontic treatment 2009, patient is having<br />

pain. A 2-D periapical radiograph reveals no apparent<br />

pathology.<br />

Figure 2: Pre-extraction 2011, a 2-D periapical radiograph<br />

shows little to no disease. There is a slight radiolucency at<br />

the distal midpoint of the root.<br />

Case Report<br />

The ability to view<br />

diseased areas in<br />

different planes can<br />

eliminate guesswork<br />

during diagnosis and<br />

help determine<br />

the least invasive<br />

procedure necessary<br />

to eliminate the<br />

dental disease.<br />

This case follows the three-year treatment of a 38-year-old<br />

female with a history of failed root canal procedures and<br />

eventual extractions. In 2009, she presented with vague pain<br />

in the lower right mandibular quadrant and complained she<br />

could not bite in the area. A digital periapical radiograph<br />

taken in September 2009 of the lower right bicuspids and<br />

molars revealed no apparent pathology (Fig. 1). Tooth #28<br />

had slight pain with percussion and some fleeting pain to<br />

cold on the buccal surface lasting less than five seconds.<br />

At some point in the three months prior to her visit, a new<br />

crown had been placed on tooth #5. An occlusal adjustment<br />

was performed on this crown to relieve the stress on<br />

tooth #28.<br />

Several months later, the patient was again seen in the<br />

office for tooth #28. Her symptoms had worsened and she<br />

was experiencing prolonged discomfort in the tooth. Pulp<br />

testing indicated a nonvital root and root canal treatment<br />

was completed. A new periapical radiograph was taken<br />

at this appointment but did not show definitive periapical<br />

pathology. Her symptoms were eliminated and she returned<br />

to normal use and function on tooth #28.<br />

Eighteen months passed and the patient returned for extreme<br />

pain in tooth #28. A new periapical radiograph was<br />

taken that revealed little to no abnormal pathology (Fig. 2).<br />

A CBCT scan was also taken that revealed a large lesion on<br />

– Missed Diagnosis Using Conventional 2-D Radiography – 15


Figure 3: Pre-extraction 2011 (same day<br />

as 2-D periapical), a CBCT scan reveals<br />

a moderate-sized radiolucency at the<br />

midpoint of the root. This is a 0.07 mm<br />

saggital slice.<br />

Figure 4: Pre-extraction axial slice (0.07<br />

mm) showing the extent of the lesion to<br />

the distal<br />

Figure 5: A 2-D radiograph showing the immediate<br />

post-extraction placement of the implant in<br />

the modified socket.<br />

the distal side of the root (Fig. 3). Further examination of the<br />

scan revealed a lateral canal midway down the root with a<br />

3 mm by 5 mm area of radiolucency in the interproximal<br />

bone (Fig. 4). Root canal retreatment was discussed with the<br />

patient and refused. Having been successfully treated with<br />

dental implants in the past, she decided on implant treatment<br />

instead. Immediate implant placement after extraction<br />

was selected as the treatment of choice because it would<br />

greatly decrease the patient’s treatment time.<br />

Luxators were used to atraumatically remove the offending<br />

tooth, and surgical spoons were used to mechanically<br />

debride the socket. The granuloma was removed in its<br />

entirety, and the entire area of the socket was decontaminated<br />

using laser energy. Osteotomy drills were then used to<br />

modify the socket, and an implant was immediately placed<br />

in the modified socket (Fig. 5). The discrepancy between the<br />

socket shape and the diameter of the implant on the buccal<br />

and lingual was less than 1.5 mm, so no additional grafting<br />

materials were placed. Within two to four months, native<br />

bone will fill in the gap.<br />

A postoperative CBCT scan taken immediately after implant<br />

placement revealed the position and the engagement of<br />

the implant in the apical half of the socket (Figs. 6, 7). The<br />

patient is healing well and will soon move forward with<br />

the final restoration. Compared to the 2-D periapical radiographs,<br />

the 3-D and MPV views provided by the CBCT scan<br />

enabled us to make a much more complete diagnosis.<br />

Immediate implant<br />

placement after<br />

extraction was<br />

selected as the<br />

treatment of<br />

choice because<br />

it would greatly<br />

decrease the<br />

patient’s<br />

treatment time.<br />

16<br />

– www.inclusivemagazine.com –


Figure 6: CBCT saggital image taken immediately after<br />

placement of the implant<br />

Figure 7: Coronal slice (0.07 mm) post implant placement<br />

showing buccal to lingual span in the existing extraction site<br />

Compared to the<br />

2-D periapical<br />

radiographs,<br />

the 3-D and MPV<br />

views provided by<br />

the CBCT scan<br />

enabled us<br />

to make a much<br />

more complete<br />

diagnosis.<br />

Conclusion<br />

Three-dimensional CBCT offers a more complete view of<br />

dental anatomy and disease than traditional 2-D radiography<br />

alone. Using this technology allows the clinician to<br />

more accurately evaluate endodontic anatomy and better<br />

diagnose the true extent of dental disease. Having a more<br />

accurate diagnosis results in a more appropriate treatment<br />

plan and helps guide a patient’s treatment toward a successful<br />

outcome.<br />

For clinical questions, contact Dr. Daniel McEowen at drdan13106@gmail.com. For<br />

technical questions, contact Keith Bateman at kbateman@prexion.com.<br />

References<br />

1. Law J. The influence of focal spot size on image resolution. Br J Radiol. 1993<br />

May;66(785):441–46.<br />

2. Cesmeli E, Berry JL, Carr JJ. Tube focal spot size and power capability<br />

impact image quality in the evaluation of intracoronary stents. Proc. SPIE<br />

5745. 2005;676–84. doi:10.1117/12.596035.<br />

– Missed Diagnosis Using Conventional 2-D Radiography – 17


Implant Q&A:<br />

An Interview with Dr. Sascha Jovanovic<br />

Go online for<br />

in-depth content<br />

Interview of Sascha A. Jovanovic, DDS, MS<br />

by Bradley C. Bockhorst, DMD<br />

Dr. Sascha Jovanovic is<br />

founder and academic<br />

chairman of the Global Institute<br />

for <strong>Dental</strong> Education (gIDE) and<br />

course director of implant dentistry for<br />

UCLA Continuing <strong>Dental</strong> Education. A leading<br />

clinician and lecturer on implant surgery<br />

and soft tissue health and esthetics, he recently took<br />

time to share his thoughts on these subjects with Inclusive<br />

magazine at gIDE’s global headquarters in Los Angeles.<br />

18<br />

– www.inclusivemagazine.com –


Dr. Bradley Bockhorst: Before we get started with the interview,<br />

can you share with us a little bit of background information<br />

on gIDE and about the studio where we are right now?<br />

Dr. Sascha Jovanovic: Of course. First of all, it’s a pleasure<br />

to be part of this interview. gIDE was started as a training,<br />

education and research institute in 2003 based on utilizing<br />

today’s new digital technology to distribute information and<br />

knowledge efficiently and swiftly. We’re kind of shrinking<br />

the world of dentists, and we are able to give continuing<br />

education to our colleagues and friends very efficiently and<br />

on their time schedules. So it’s online streaming, it’s digital<br />

downloads, it’s utilizing learning tablets. And my favorite is<br />

the blended learning, which combines in-person training<br />

and online education.<br />

Now, to do this — we started about eight years ago, when<br />

gIDE was founded — we needed a recording studio. We’re<br />

very lucky to be here today in this building, which formerly<br />

was the studio of The Beach Boys. In this area where we<br />

are right now, one of their famous songs could have been<br />

created. So it’s fun for us to be here as dentists, as educators<br />

and as clinicians because we can give a little creative juice<br />

to the education we provide.<br />

BB: Very fun history. The first several questions I have for you<br />

are related to your thoughts and experiences with various<br />

implant and abutment designs. With that in mind, what is the<br />

influence of the implant surface on crestal bone stability?<br />

SJ: We know today that implant surfaces can affect bone<br />

and soft tissue positively. We like an implant to have a<br />

micro or moderately roughened surface, so the bone integration<br />

and stability in the full length of the implant can be<br />

maintained. We also know that a polished neck loses more<br />

crestal bone than an enhanced surface. So when I place an<br />

implant, I always choose an implant that has a roughened<br />

surface all the way up the neck of the implant.<br />

We like an implant to have a micro<br />

or moderately roughened surface,<br />

so the bone integration and stability<br />

in the full length of the implant can<br />

be maintained.<br />

BB: The next question is related to that collar design. You prefer<br />

to have it going all the way to the top of the implant?<br />

SJ: Right. When you look at the neck of the implant, which<br />

is the next point to think about, the most important bone<br />

from a standpoint of soft tissue is the crestal bone. So that’s<br />

why, when we evaluate patients over the long term, we<br />

always want to know what the crestal bone stability is. When<br />

you are evaluating an implant system, here also you want to<br />

know the crestal bone stability. In addition to surface characteristics,<br />

new research nicely shows that implants with a<br />

straight neck or a reverse-neck design are even better for<br />

crestal bone stability.<br />

Implants with a straight neck or a<br />

reverse-neck design are even better<br />

for crestal bone stability.<br />

There is a tendency to move away from implants with<br />

a countersink, like the traditional Brånemark System ®<br />

implants (Nobel Biocare; Yorba Linda, Calif.), in the esthetic<br />

zone — versus something that has more of a straight neck,<br />

such as NobelReplace ® (Nobel Biocare), the most widely<br />

used two-piece implant system. And, currently, implant<br />

designs are being introduced with a reverse-neck design.<br />

Those, again, seem to be better on maintaining the bone.<br />

These are promising results, and that’s definitely the direction<br />

the research is going.<br />

BB: Now, on top of the implant, what abutment materials have<br />

you found to be the most biocompatible?<br />

SJ: Abutment materials are a big topic of discussion because<br />

we have titanium, which we’ve had for the longest<br />

period of time. Later on we had alumina. Today we have<br />

zirconia. And, of course, we have the gold alloy abutments,<br />

like the UCLA-type abutments. Then we have temporary<br />

abutments — which many companies were using or are<br />

still using — which are made out of plastic or some form<br />

of acrylic.<br />

When we look at animal research, it’s very clear that there<br />

are only two materials that are stable for soft tissue, and<br />

those are titanium and zirconia. Now, of course, we can say<br />

animal research is not the same as human clinical data, but<br />

we try to follow the information that is available to us.<br />

– Implant Q&A: An Interview with Dr. Sascha Jovanovic – 19


There are only two materials that<br />

are stable for soft tissue, and those<br />

are titanium and zirconia.<br />

In my practice, I prefer to use titanium or zirconia in a case<br />

that is well planned with good implant position. But, sometimes<br />

you have the unusually complex case, and then we<br />

can still use gold alloy, with the knowledge that we might<br />

lose some crestal bone and soft tissue. Therefore, it’s better<br />

not to use this material in the esthetic zone.<br />

BB: There have been various transgingival designs for abutments<br />

— everything from convex to straight to concave designs.<br />

Which design have you found to best support peri-implant<br />

health and esthetics?<br />

SJ: Well, the tendency that’s been more and more supported<br />

in the last few years is that platform switching, or<br />

the use of abutments with reduced width in relation to the<br />

implant diameter, promotes better soft tissue stability and<br />

improves soft tissue health. Abutments are reduced or, as<br />

you mentioned, some even have a concave design, which is<br />

something we can do today with CAD/CAM. So, for me, it’s<br />

very important to use, at max, a diameter of an abutment<br />

that is the same size as the implant. I won’t use those divergent<br />

ones because divergence means mechanical stress to<br />

the tissues, and mechanical stress to the soft tissues means<br />

an increased risk of recession.<br />

Platform switching, or the use of<br />

abutments with reduced width in<br />

relation to the implant diameter,<br />

promotes better soft tissue stability<br />

and improves soft tissue health.<br />

BB: To make sure I understand, you prefer a straight emergence?<br />

And at what point, from a peri-implant standpoint, do<br />

you like to start having that emergence profile?<br />

SJ: This is very case dependent, as you can imagine. The<br />

best way I can explain it is: Imagine we’re looking at a tulip.<br />

(I’m Dutch, so I love tulips, of course.) Like a tulip, the<br />

stem, which is the abutment, should be really nice and narrow,<br />

and once we come close to the gingival margin, that’s<br />

where we can emerge out. So let’s say about 0.5 mm or so<br />

below the gingival margin is where the crown goes to its<br />

full emergence.<br />

BB: In clinical practice, there are some procedures in which<br />

you’re taking abutments on and off a lot. What impact does<br />

that have on the surrounding tissues?<br />

SJ: This is clear-cut because the research studies show that<br />

implant design is unrelated to bone loss or bone stability. As<br />

an example, if you use a two-stage or a two-piece implant<br />

versus a one-piece implant, the bone stays stable until we<br />

start to remove the abutments. So, as soon as we do impressions<br />

or some type of laboratory work or change — boom!<br />

We get a reaction. And the reaction is usually soft tissue inflammation.<br />

Soft tissue inflammation leads to inflammation<br />

in the bone, which leads to bone loss. Bone loss leads to<br />

potential risk for gingival recession.<br />

So it’s very crucial for any clinician to try to pick the final<br />

abutment as early as possible. A suggestion for clinical practice<br />

is that implant impressions be taken as early as possible.<br />

It could be at the time of implant placement or at<br />

the time of uncovering. And then we select an abutment<br />

that, if possible, is the permanent abutment for the case.<br />

Now, I realize that’s not always possible. You need to be<br />

well equipped and you need to plan the case well, but that<br />

would be the ideal.<br />

It’s very crucial for any clinician to<br />

try to pick the final abutment as<br />

early as possible.<br />

Another good clinical practice is to leave a stock abutment<br />

in for at least two to three months, so the soft tissues are<br />

stable, and then make one more abutment switch at that<br />

time. So you might have two abutment changes. But don’t<br />

do what we used to do in the old days, where we removed<br />

abutments frequently, as this sometimes creates a negative<br />

result which, of course, none of us want.<br />

BB: Back to implant placement. What do you find is the ideal<br />

interproximal space between the implant and the adjacent<br />

roots?<br />

SJ: Spacing between implants and any other anatomical<br />

structures is very important for preservation of the existing<br />

periodontal and bone tissue. We have information in the<br />

literature that suggests that between adjoining implants you<br />

20<br />

– www.inclusivemagazine.com –


need a minimum of 3 mm to 4 mm, which is a good, safe<br />

space. Between an implant and a natural tooth, you need<br />

2 mm or more. This will support the periodontal ligament,<br />

and the more bone we have, the better.<br />

Between adjoining implants you<br />

need a minimum of 3 mm to 4 mm<br />

... Between an implant and a natural<br />

tooth, you need 2 mm or more.<br />

So when you are planning a case, you probably want fewer<br />

implants in the anterior region because you want to have<br />

optimal soft tissue, and you also want to have smaller<br />

diameters. In my private practice, for example, I don’t place<br />

wide-platform implants in the anterior region because it<br />

compromises the soft tissue. I select regular and sometimes<br />

even narrow implants. In addition to this, think about cases<br />

where you have to place multiple implants next to each<br />

other. Often cases are better if you bring in a pontic, so you<br />

have more bone and soft tissue to work with. So, less is<br />

better, and increase the spacing between implants.<br />

BB: How do you handle the cases of, say you’re doing a single<br />

tooth — maybe it’s a narrow maxillary lateral incisor or lower<br />

incisor — and you just don’t have that 2 mm on either side?<br />

How are you handling those cases?<br />

SJ: Well, those are difficult cases. So my recommendation<br />

is: When you are dealing with difficult anatomical conditions,<br />

be very careful, because you are setting yourself<br />

up for a dangerous situation, in which tissue can be lost.<br />

Unfortunately, I see many cases in my practice that are redo<br />

cases, and a loss of the periodontal ligament and papilla on<br />

a natural tooth.<br />

If you have, let’s say, less experience with implants, my recommendation<br />

would always be: Stay away from those cases;<br />

leave that up to colleagues who have more experience, who<br />

know what the pitfalls are. Because the worst you can do is<br />

try to do the best you can for your patient and, in the end,<br />

you get a negative result. So those are not good cases. Get<br />

enough tissue. Get enough space.<br />

BB: What is your ideal position for the top of the implant in<br />

relation to the crest of the bone?<br />

SJ: I published in 1997 a scientific paper describing my<br />

observations about the ideal relationship of the neck of the<br />

implant and the connection with the abutment to the soft<br />

tissue margin. And we concluded that everything is related to<br />

the biological width. The biological width around implants<br />

is approximately 3 mm, so that’s the soft tissue dimension<br />

around implants and around abutments. The goal today will<br />

always be to place the implant neck no deeper than 3 mm<br />

below your optimal gingival margin. And once you know<br />

what your optimal gingival margin is, which should come<br />

from your diagnosis and models, then you count back and<br />

you place the implant about 3 mm below that.<br />

We concluded that everything is<br />

related to the biological width.<br />

So, now, what does that mean in many clinical situations?<br />

When the crest has bone loss, there’s a part of the implant<br />

neck that is going to be exposed. And with that implant<br />

neck, now you need to make a decision. Should I do a grafting<br />

to bring that bone back, or should I maybe place the<br />

implant deeper and then accept that the crown is going to<br />

be longer and there is going to be gingival recession? This<br />

may be acceptable for some patients with a low lip line.<br />

The goal today will always be to<br />

place the implant neck no deeper<br />

than 3 mm below your optimal<br />

gingival margin.<br />

BB: Along the same line, if you decide you are going to do<br />

grafting, when do you determine that it is truly indicated and<br />

which procedures you should perform?<br />

SJ: Bone grating, of course, is extremely important. You can<br />

see how soft tissue is related to bone. Remember, we have<br />

this bone frame, which really sets up the soft tissue. The<br />

soft tissue dimension is stable; it’s 3 mm to 3.5 mm. So just<br />

always keep that in mind. We make a decision before we<br />

start the case, and that is: Should this case be grafted, so we<br />

can get into this good range of 3 mm to 3.5 mm of soft tissue?<br />

Or maybe the patient doesn’t want to do it; maybe they<br />

accept pink porcelain; maybe the patient accepts a longer<br />

crown. Then, of course, that is discussed with the patient.<br />

But, in principle, we graft most cases if we need optimal<br />

soft tissue dimensions.<br />

– Implant Q&A: An Interview with Dr. Sascha Jovanovic – 21


BB: Do you have a material of choice for grafting?<br />

SJ: The most used procedure, which is evidence-based<br />

in the literature — and we have been doing this now for<br />

20 years — is the GBR principle, which is the Guided Bone<br />

Regeneration principle. This is basically the principle where<br />

we use bone grafts based on particulate — some of it is autogenous,<br />

which is the gold standard, and some of it could<br />

be a biomaterial — and then we cover this with a barrier<br />

membrane, which could be resorbable or nonresorbable.<br />

This will, first of all, stabilize the bone graft for regeneration<br />

purposes and, secondly, exclude the soft tissue and bacteria<br />

from invading, so we don’t have a loss of that bone.<br />

BB: Another question along the line of bone grafting: If you<br />

are going to do a delayed case — say you’re going to extract a<br />

tooth and then place an implant later — would you typically<br />

graft that socket?<br />

SJ: Yes, socket grafting is something that is more of a norm<br />

today. So I would always recommend socket grafting to any<br />

clinician and to any colleague for sure in the single-rooted<br />

teeth — which basically means everything that is toward<br />

the anterior — because it will prevent collapse of the buccal<br />

plate, it will maintain more of the soft tissue, and it will<br />

improve the stability of the soft tissue dimension.<br />

I would always recommend socket<br />

grafting to any clinician and to any<br />

colleague for sure in the singlerooted<br />

teeth.<br />

Socket grafting is a very successful procedure, and various<br />

materials work. It could be a biomaterial; it could be<br />

a growth factor; it could be an autogenous bone graft.<br />

But, important as always, the extraction socket needs to<br />

be clean. The infection, which often was there with the<br />

tooth, needs to be cleaned out. So, sometimes you need<br />

to spend more time on extraction and cleaning it out than<br />

just on a grafting procedure. That’s very important because,<br />

unfortunately, I’ve seen a lot of socket grafting which came<br />

back, and the material is just laying around, and it didn’t do<br />

anything. So that is not a good idea.<br />

BB: Once you’ve cleaned out the socket and you’ve grafted,<br />

what do you typically like to cover it up with?<br />

SJ: Socket grafting, as you know, has different options. The<br />

first option, which of course most of us will look at, is to<br />

use a barrier membrane. This can be either a nonresorbable<br />

material — today there’s the dense PTFE material — or we<br />

can use a resorbable material. Then there are also some<br />

new materials. We have collagen grafts, which are thicker;<br />

they have a thickness of about 5 mm. These help us to, first<br />

of all, stabilize the soft tissue and the bone graft, and they<br />

also allow the soft tissue to creep in. And then we have a<br />

procedure that is called socket seal surgery. Socket seal surgery<br />

is a procedure that has been around for a long time.<br />

Cobi Landsberg published something on this, quite nicely,<br />

and he’s using a free gingival graft to stabilize the bone<br />

graft and the soft tissue.<br />

BB: We’ve talked a lot about hard tissue grafting. What’s the<br />

benefit of soft tissue grafting in implant cases?<br />

SJ: What you are focusing on, Brad, is really soft tissue<br />

esthetics and health. But you can see that there are a lot of<br />

things which are happening to soft tissue before we really<br />

get to it, when we are talking about bones, implants, abutments,<br />

etc.<br />

Why soft tissue grafting? Soft tissue grafting is important because<br />

whenever we remove teeth, or whenever we lose teeth,<br />

soft tissue dimension shrinks. So, we often go from gingival<br />

thickness to something thin. And implants, they don’t have<br />

that stability like a tooth has. What we try to do with soft<br />

tissue grafting is to actually increase the thickness. So we<br />

create a new gingival biotype, which is thicker. And what<br />

does that do? This could prevent recession again, improve<br />

esthetics because we won’t have that metal shadowing<br />

through, and give a more natural look. So it is resistance<br />

to recession, resistance to bone loss because the biological<br />

width is more stable, and also it gives better soft tissue<br />

esthetics and health.<br />

BB: Over the last couple of years, there have been a lot of<br />

lectures on connective tissue grafting, particularly in the<br />

esthetic zone. What’s coming across is that labial bone loss is<br />

inevitable, no matter what you do. Have you found that to be<br />

the case? And then do you have to use connective tissue grafting<br />

basically as a cosmetic Band-Aid? Or what’s been your experience<br />

as far as maintaining that labial bone?<br />

What we try to do with soft tissue<br />

grafting is to actually increase the<br />

thickness. So we create a new<br />

gingival biotype, which is thicker.<br />

22<br />

– www.inclusivemagazine.com –


SJ: Connective tissue grafting leads into or follows up on<br />

the question you just asked. Let me refer to a very nice<br />

study that we published in 2009, where we looked at vertical<br />

bone augmentation using the GBR principle. And what<br />

we saw there, when we did a combo — a bone graft and<br />

a connective tissue graft — is that we always had better<br />

crestal bone stability.<br />

So, you have to think about it. Soft tissue is very delicate,<br />

so when you don’t have enough soft tissue, bone has a<br />

tendency to shrink more, to lose a little bit more. What connective<br />

tissue does is it, first of all, thickens the soft tissue.<br />

It prevents bone from losing too much, so it kind of keeps<br />

it in a healthy range. And, of course, it improves again the<br />

end outcome, which is esthetics and health.<br />

BB: Very good. Then, for a final question, is a temporary restoration<br />

required for controlling the final soft tissue esthetics?<br />

SJ: Yes, absolutely. This is a tough one because, obviously,<br />

a lot of patients want to have a final restoration as fast as<br />

possible. I always say to my patients that a temporary is like<br />

a prototype. We need to shape and support the soft tissues<br />

in such a way that we know that they’re stable. We don’t<br />

want to have a situation where we now see recession. So,<br />

potentially, we have a final crown in place and the tissues<br />

are not there yet, the gingival papilla is not there yet, and<br />

then we have recession again.<br />

BB: To start wrapping things up, first I’d like to thank you for<br />

taking the time to talk with me. We went through a lot in a<br />

short period. If there are clinicians reading this who want to<br />

get more education and training on different types of hard and<br />

soft tissue grafting and esthetics, what would you recommend?<br />

SJ: Well, our field is full of needs for training and education.<br />

This is a great field. I’m very passionate about it. I love<br />

this area and have been involved in it, thankfully, for more<br />

than 20 years. If you want to get more involved with this<br />

and get more training in soft tissue grafting, choose the<br />

right partners for you. It could be one mentor whom you<br />

trust, it could be an institute that you trust, it could be a university,<br />

or it could be a mix of each. But go through training<br />

and education as much as you can. Think about it like this:<br />

For us, what’s most important is how much experience you<br />

have. Then of course there’s skill. What’s your skill level?<br />

Skill can improve and experience can improve. So, go for it;<br />

find the right partner and learn as much as you can. I’m still<br />

learning every single day.<br />

We need to shape and support the<br />

soft tissues in such a way that we<br />

know that they’re stable.<br />

So I would urge every single patient, especially in the<br />

esthetic zone, to go through a temporary phase. And, again,<br />

the same thing for the clinician; we need to have something<br />

which gives us a better result. And the better result<br />

definitely is there when we first do a prototype, create the<br />

abutment correctly, create the emergence correctly, and<br />

then let the soft tissue flow in. And this soft tissue growth<br />

and stabilization around abutments and around temporaries<br />

could go for more than 12 months. So make sure that you<br />

leave the spaces in. Make sure that you have the abrasion<br />

spaces into which soft tissues can flow. And don’t worry<br />

about the black triangles right then because we have the<br />

potential to regenerate soft tissues interproximally between<br />

3 mm to 5 mm. But you have to give it time to fill in, and<br />

that’s the temporary phase.<br />

– Implant Q&A: An Interview with Dr. Sascha Jovanovic – 23


– www.inclusivemagazine.com –


Three-Dimensional Treatment Planning<br />

with Surgical Guides and<br />

Mini Implant-Retained Dentures<br />

Go online for<br />

in-depth content<br />

by Paresh B. Patel, DDS<br />

At no time in the history of dentistry has the<br />

blending of new technologies and concepts<br />

given rise to the sheer number of exciting possibilities we<br />

face today. For example, implant dentistry has benefited<br />

tremendously from the incorporation of 3-D Cone Beam<br />

Computed Tomography (CBCT) and the ability to mill a surgical<br />

placement guide. It is now possible to take a CBCT<br />

scan and, from the resulting data, virtually place mini dental<br />

implants in such a way as to maximize the available bone,<br />

increase parallelism and avoid vital structures (Figs. 1a, 1b).<br />

Planning a case in this virtual environment also reduces surgical<br />

and healing time because it allows the doctor to safely<br />

utilize a flapless procedure during the actual placement.<br />

What’s more, this digital treatment plan can be performed<br />

without requiring the doctor to leave his office. With a<br />

PC and an Internet connection, he can work through all<br />

details of the proposed treatment plan with a skilled digital<br />

technician via Web conference. There is no learning curve<br />

required to operate the software, as the assisting technician<br />

handles this on the doctor’s behalf, repositioning implants<br />

as directed with just a few mouse clicks. Adding this kind<br />

of technology to your armamentarium will help ensure a<br />

smooth surgical outcome and increase patient acceptance<br />

of a prosthetically driven treatment plan.<br />

Figures 1a, 1b: Digital treatment plan demonstrating virtual placement of<br />

mini implants<br />

It is now possible to take a CBCT scan and, from the resulting data,<br />

virtually place mini dental implants in such a way as to maximize the<br />

available bone, increase parallelism and avoid vital structures.<br />

– Three-Dimensional Treatment Planning with Surgical Guides and Mini Implant-Retained Dentures – 25


Figures 2a, 2b: The patient’s edentulous maxilla and mandible<br />

Ridges for which mini implants<br />

are ideally suited often leaves<br />

them supported on both sides by<br />

high-density cortical plate.<br />

Figure 3: Preoperative panoramic X-ray revealing bilateral pneumatization of<br />

the maxillary sinus<br />

Mini implants have been used successfully to improve the<br />

retention of dentures. 1 With the average age of our population<br />

increasing as people continue to live longer, the need<br />

to improve patients’ lives with secure full dentures is growing.<br />

2 Many edentulous patients present with inadequate<br />

bone width for the placement of traditional implants, which<br />

can require 6 mm of bone or more in the buccal-lingual<br />

dimension. To reach the necessary bone width, these patients<br />

would have to undergo expensive, time-consuming<br />

bone grafting procedures. Even if grafting is not required,<br />

many elderly patients are dissuaded by the cost and trauma<br />

associated with implant surgery. A mini implant, however,<br />

can be placed in as little as 3 mm of buccal-lingual bone<br />

width. The single-stage placement protocol is simpler and<br />

less traumatic. Fewer office visits are required because mini<br />

implants allow for immediate loading in the presence of primary<br />

stability, which is facilitated by an auto-advancing design<br />

that compresses and condenses the surrounding bone<br />

rather than drilling it away. In addition, the narrow ridges<br />

for which mini implants are ideally suited often leaves them<br />

supported on both sides by high-density cortical plate. In<br />

terms of affordability, these smaller implants provide a costeffective<br />

solution that enables more patients to move forward<br />

with implant therapy, due to the reduced number of<br />

parts needed in the surgical and the laboratory phases. 3<br />

CASE REPORT<br />

The patient in this case, a 55-year-old female, had had all<br />

her remaining maxillary and mandibular teeth extracted 11<br />

months prior (Figs. 2a, 2b). At that time, she had received<br />

conventional maxillary and mandibular dentures. Her chief<br />

complaint was that these dentures were nonretentive and<br />

nonfunctional, becoming dislodged or falling out whenever<br />

she ate or spoke. Although the extractions were recent and<br />

she was not a denture wearer for a considerable amount of<br />

time, there was already excessive resorption noted in the<br />

mandible. Radiographically, bilateral pneumatization of the<br />

maxillary sinus was also noted (Fig. 3).<br />

Prior to obtaining a CT scan, reline impressions were taken<br />

with Impregum brand impression material (3M ESPE; St.<br />

Paul, Minn.), and the dentures were sent to <strong>Glidewell</strong> Laboratories<br />

(Newport Beach, Calif.) (Figs. 4a, 4b). From that set<br />

of impressions, upper and lower dual-scan appliances were<br />

fabricated (Figs. 5a, 5b). It is important to note here that the<br />

accuracy of each surgical guide depends greatly on the accuracy<br />

of the impression taken for each scan appliance. Any<br />

reduction in movement of the surgical guide will increase<br />

the accuracy and likely success of the final implant placement.<br />

Using the GXCB-500 powered by i-CAT ® (Gendex<br />

<strong>Dental</strong> Systems; Des Plaines, Ill.), three CT scans were taken<br />

— one of the patient with the scan appliances in the mouth,<br />

and one of each scan appliance by itself. From these scans,<br />

26<br />

– www.inclusivemagazine.com –


The accuracy of each surgical guide depends greatly on the<br />

accuracy of the impression taken for each scan appliance.<br />

Figures 4a, 4b: Maxillary and mandibular reline impressions<br />

Figures 5a, 5b: Upper and lower arch dual-scan appliances fabricated at<br />

<strong>Glidewell</strong> Laboratories<br />

the Inclusive ® Mini Implants (<strong>Glidewell</strong> Laboratories) selected<br />

for this procedure could be virtually placed utilizing Blue<br />

Sky Plan ® software (Blue Sky Bio; Grayslake, Ill.).<br />

Next, a Web conference was scheduled with the Inclusive<br />

Digital Treatment Planning team. At the time of the actual<br />

conference session, the restoratively driven treatment plan<br />

was mostly complete. Vital structures, placement paths and<br />

parallelism of the implants had already been identified. The<br />

Digital Treatment Planning team saves the doctor valuable<br />

time by completing most of the tedious tasks in advance. In<br />

this case, I confirmed the final implant positions and, with<br />

the approved plan, the surgical guides were milled.<br />

For the retention of a maxillary overdenture, it is recommended<br />

that six mini implants be placed in the premaxillary<br />

region. To retain a mandibular overdenture, no fewer<br />

than four mini implants should be placed anterior to the<br />

mental foramina. 4 The smaller number of implants required<br />

in the mandible is due to the increased bone density<br />

It is recommended that<br />

six mini implants be placed in<br />

the premaxillary region. To retain<br />

a mandibular overdenture,<br />

no fewer than four mini implants<br />

should be placed anterior to<br />

the mental foramina.<br />

– Three-Dimensional Treatment Planning with Surgical Guides and Mini Implant-Retained Dentures – 27


With a CT scan ... all of the patient’s anatomy and soft<br />

tissue anomalies can be factored into the digital treatment plan.<br />

Figure 6: Maxillary surgical guide in place<br />

Figure 8: First Inclusive Mini Implant hand-tightened into place<br />

Figure 7: A 1.5 mm diameter pilot drill used to depth<br />

Figure 9: Inclusive Mini Implants rotated to depth using the Inclusive Mini<br />

Implant Handpiece Driver<br />

compared to that found in the maxilla. In this case, it was<br />

decided that 1.5 mm diameter guide sleeves would be used<br />

for the 2.2 mm diameter Inclusive Mini Implants to be<br />

placed in the mandible. Due to the softer bone of the maxilla,<br />

it was decided that 1.5 mm sleeves would also be used<br />

for the thicker, 2.5 mm diameter Inclusive Mini Implants<br />

placed there. In denser bone, I would have asked for 1.7<br />

mm diameter sleeves for use in the maxilla.<br />

Even though the placement of mini dental implants is relatively<br />

simple and straightforward, a common argument<br />

against placing them is that the surgery is performed “blind.” 5<br />

Critics contend that by not raising a flap, as is the recommended<br />

protocol when placing mini implants, the doctor<br />

cannot accurately gauge the proper insertion path. With a<br />

CT scan, however, all of the patient’s anatomy and soft tissue<br />

anomalies can be factored into the digital treatment plan.<br />

This digital treatment plan is not merely a “best guess”; rather,<br />

it provides a true representation of the anticipated clinical<br />

outcome. The surgical guide used to translate the virtual<br />

outcome to a physical outcome is precisely fabricated by a<br />

computer-controlled milling station, and the guide sleeves<br />

are placed to tight tolerances. As a result, the opportunity for<br />

error during placement is significantly reduced.<br />

The patient was draped, and a clean operating environment<br />

was established. A preoperative rinse with Peridex <br />

(3M ESPE) was performed prior to local infiltration with<br />

28<br />

– www.inclusivemagazine.com –


Cook-Waite Lidocaine ® HCI 2% and Epinephrine 1:100,000<br />

(Kodak <strong>Dental</strong> Systems; Rochester, N.Y.). The upper surgical<br />

guide was inserted and stabilized by both the doctor<br />

and assistant (Fig. 6). Once a confirmed fit was verified, the<br />

1.5 mm diameter pilot drill was introduced into the guide<br />

sleeve (Fig. 7). The guide sleeve orients the pilot drill in the<br />

correct trajectory. The top of the sleeves are set at 9 mm<br />

from the top of the implant, and this vertical distance must<br />

be accounted for when determining proper drill depth. The<br />

recommended procedure for unguided site preparation is<br />

to drill to a depth that is approximately one-half the length<br />

of the implant, plus the tissue depth. In this case, the six<br />

mini implants to be placed in the maxilla were each 10 mm<br />

in length, so half of that length (5 mm) plus the tissue depth<br />

(approximately 2 mm) accounted for 7 mm of drill depth.<br />

Adding the 9 mm length for the guide sleeves necessitated<br />

an overall drill depth of 16 mm. Each Cortical Bone Drill<br />

included with the Inclusive Mini Implant System has depth<br />

markings at 10 mm, 13 mm and 15 mm, so drilling to 16 mm<br />

meant drilling just past the last mark on the drill.<br />

The drilling process was conducted at 1250 RPM under<br />

copious irrigation using the MD 20 Dual Motor System<br />

(Nouvag USA; Lake Hughes, Calif.). For the best chance of<br />

long-term implant success, it is important to minimize tissue<br />

damage and thermal trauma to the bone. 6 Because Inclusive<br />

Mini Implants are self-tapping, only a single pilot drill is<br />

required; no additional finishing bits or bone formers are<br />

needed. The implant will follow the path created by the<br />

pilot drill and compress and condense the bone to help<br />

achieve immediate primary stability. In certain cases, it is<br />

possible to engage both cortical plates for even greater stability.<br />

All six pilot holes were made following the same process,<br />

and the surgical guide was removed. A periodontal<br />

probe was used to confirm that all pilot holes in the cortical<br />

bone did not perforate in the buccal-lingual dimension.<br />

Figure 10: Pilot drill engaged in the mandibular surgical guide<br />

The implant will follow<br />

the path created by<br />

the pilot drill and<br />

compress and condense<br />

the bone to help<br />

achieve immediate<br />

primary stability.<br />

One at a time, the Inclusive Mini Implants were removed<br />

from their sterile packs and glass vials and hand-tightened<br />

with the attached carrier until they were difficult to turn<br />

(Fig. 8). The Handpiece Mini Implant Driver attachment<br />

was then used to gently rotate each mini implant to depth<br />

(Fig. 9). Final seating was verified at 35 Ncm using the<br />

Torque/Ratchet Wrench included in the Inclusive Surgical<br />

Instrumentation Kit.<br />

The same process was repeated for the mandible using the<br />

lower surgical guide (Fig. 10). In this case, the Inclusive Mini<br />

Implants were 13 mm in length, so the pilot drill was taken<br />

to a depth of approximately 18 mm, or almost to the hub.<br />

The overall length of the pilot drill from cutting tip to shank<br />

is approximately 20 mm. Once again, final seating was verified<br />

at 35 Ncm to ensure primary stability (Fig. 11).<br />

Figure 11: Final placement of four Inclusive Mini Implants in the mandible<br />

– Three-Dimensional Treatment Planning with Surgical Guides and Mini Implant-Retained Dentures – 29


Following successful placement of all mini implants, Blu-<br />

Bite HP bite registration material (Henry Schein; Melville,<br />

N.Y.) was injected onto the intaglio surface of the dentures<br />

to help indicate where the dentures would need to be relieved<br />

to allow for passive fit over the mini implant heads<br />

(Figs. 12a, 12b). An NTI ® Universal Cutter pear-shaped bur<br />

(Axis <strong>Dental</strong>; Coppell, Texas) was used to help create the<br />

appropriate-shaped spaces (Figs. 13a–13d). The acrylic bur<br />

is 2.9 mm wide and cuts a hole that is just the right size<br />

for the O-ball head of the mini implant. With a few circular<br />

strokes, you can easily widen the hole to accommodate the<br />

full O-ring Housing, which is approximately 3.5 mm tall<br />

and 4.75 mm wide.<br />

Once the majority of acrylic was removed, Dr. Thompson’s<br />

Color Transfer Applicators (Great Plains <strong>Dental</strong> Products;<br />

Kingman, Kan.) were used to mark the tops of the O-balls.<br />

Any marks that transferred to the dentures indicated additional<br />

acrylic that had to be removed to ensure a completely<br />

passive fit (Figs. 14a, 14b).<br />

A soft reline was performed chairside using COE-SOFT reline<br />

material (GC America; Alsip, Ill.) to stabilize the existing<br />

denture during the healing phase. This gives the mini implants<br />

a chance to osseointegrate fully before more stressful<br />

loads are placed upon them. In a few weeks, a new set<br />

of Inclusive Mini Implant Overdentures will be fabricated,<br />

Figures 12a, 12b: Bite registration material injected onto the intaglio surface of the dentures<br />

Figures 13a–13d: Pear-shaped acrylic bur used to relieve the dentures<br />

30<br />

– www.inclusivemagazine.com –


with the O-ring Housings built in. Had the patient been satisfied<br />

with the esthetics of her existing mandibular denture,<br />

we could have performed a chairside pickup of the O-rings<br />

during the same visit, using a hard reline material like Triad<br />

DuaLine (Dentsply; York, Pa.). With regard to the maxillary<br />

denture, it is preferable to perform a soft reline in order to<br />

assure proper osseointegration. Even so, this should take a<br />

matter of weeks, rather than months, as in the case of most<br />

traditional implants.<br />

A postoperative CT scan was then taken. The cross-sectional<br />

slices demonstrate the implants in almost the exact positions<br />

proposed by our digital treatment plan. They confirm<br />

our preoperative goals of taking full advantage of the available<br />

bone while keeping the implants as parallel as possible<br />

(Fig. 15). Had we attempted this case without the use of a<br />

digitally milled surgical guide, these goals would have been<br />

far more difficult to achieve.<br />

Conclusion<br />

The Inclusive Mini Implant System, particularly when used<br />

in concert with Digital Treatment Planning services, represents<br />

an ideal opportunity for general practitioners to<br />

become involved in implant dentistry. In today’s repressed<br />

economy, offering this kind of valuable, inexpensive treatment<br />

enables cost-conscious patients to enjoy the many<br />

benefits of secure, retentive dentures. The use of CBCT, digital<br />

planning and surgical guides helps to reduce clinician<br />

stress, save chairtime and ensure a predictable outcome.<br />

The flapless technique allows for minimal patient discomfort<br />

and a greater chance for immediate loading — aspects<br />

that improve overall client satisfaction. These simplified<br />

protocols and conservative procedures are made possible<br />

by integrating advanced technology and new materials into<br />

everyday implant dentistry.<br />

Figures 14a, 14b: Color transfer process used to verify passive fit over the<br />

implant heads<br />

The use of CBCT, digital<br />

planning and surgical guides<br />

helps to reduce clinician stress,<br />

save chairtime and ensure a<br />

predictable outcome.<br />

References<br />

1. Misch K, Neiva R. Small-diameter implants for optimal stabilization of implantsupported<br />

overdentures. Pract Proced Aesthet Dent. 2007 Aug;19(7):428–31.<br />

2. U.S. Census Bureau, Population Division, Population Projections Branch.<br />

National population projections I: summary files. Total population by age, sex, race,<br />

and Hispanic origin. Available at: www.census.gov/population/www/projections/<br />

natsum-T3.html.<br />

3. Clinical Research Associates. Small-diameter ‘mini’ implants — user status report.<br />

CRA Newsletter. 2007;31:1–2.<br />

4. Bulard RA, Vance JB. Multi-clinic evaluation using mini-dental implants for<br />

long-term denture stabilization: a preliminary biometric evaluation. Compend Contin<br />

Educ Dent. 2005 Dec;26(12):892–97.<br />

5. Flanagan D. Flapless dental implant placement. J Oral Implantol. 2007;33(2):75–83.<br />

6. Sharawy M, Misch CE, Weller N, et al. Heat generation during implant drilling:<br />

significance of motor speed. I Oral Maxillofac Surg. 2002 Oct;60:1160–69.<br />

Figure 15: Postoperative CT scan showing parallelism of the maxillary and<br />

mandibular implants<br />

– Three-Dimensional Treatment Planning with Surgical Guides and Mini Implant-Retained Dentures – 31


Clinical Tip:<br />

<strong>Dental</strong> Photography<br />

as a Laboratory<br />

Communication Tool<br />

Go online for<br />

in-depth content<br />

by Bradley C. Bockhorst, DMD<br />

Patient photographs are one of the most useful tools available to a clinician when working up a case and<br />

communicating with the laboratory, and they can be especially helpful when treating edentulous cases. For a<br />

trial denture setup, tooth arrangement, shade, midline, vertical dimension of occlusion and closest speaking space can be<br />

evaluated. When deciding between an overdenture and a screw-retained denture, a trial denture without a labial flange can<br />

be used to evaluate the transition line in relation to the smile line and midface support. Including photographs with your<br />

lab prescription can prove invaluable in helping the technician achieve your desired treatment goals.<br />

The images that follow illustrate this technique. Like the old axiom states: A picture can say a thousand words!<br />

Figure 1a: With the patient’s lips closed, measure<br />

the vertical dimension of occlusion. Then ask the<br />

patient to swallow and let his or her lower jaw relax<br />

to evaluate the vertical dimension at rest.<br />

Figure 1b: With the patient’s lips slightly open, evaluate<br />

the incisal edge position and closest speaking<br />

space by asking the patient to pronounce “f,” “ch”<br />

and “s” sounds.<br />

A trial denture<br />

without a labial<br />

flange can<br />

be used to<br />

evaluate the<br />

transition line<br />

in relation to<br />

the smile line<br />

and midface<br />

support.<br />

Figure 2a: Smile line<br />

Figure 2b: High smile line<br />

32<br />

– www.inclusivemagazine.com –


Figure 3a: Smile line without prosthesis<br />

Figure 4a: Profile with labial flange<br />

Figure 3b: High smile line without prosthesis.<br />

NOTE: The maxillary ridge can be seen.<br />

Figure 4b: Profile without labial flange<br />

Including<br />

photographs<br />

with your lab<br />

prescription<br />

can prove<br />

invaluable in<br />

helping the<br />

technician<br />

achieve your<br />

desired<br />

treatment<br />

goals.<br />

Figure 5a: Evaluating the incisal horizontal plane<br />

in relation to the interpupillary line<br />

Figure 5b: Evaluating the midline<br />

– Clinical Tip: <strong>Dental</strong> Photography as a Laboratory Communication Tool – 33


800-854-0970


www.glidewellce.com


Welcome to the <strong>Glidewell</strong> International Technology Center.<br />

The opening of this educational center marks another milestone<br />

for <strong>Glidewell</strong> Laboratories. It signifies the efforts of so<br />

many, and highlights our continued evolution over more than<br />

40 years of growth.<br />

We have become a hybrid organization, crossing the traditional<br />

boundaries of dental technology with the digital manufacture<br />

of our restorations, while also fabricating the raw materials,<br />

components and systems that comprise those restorations.<br />

Whether you look at our development of intraoral scanners,<br />

the design and manufacture of implants, abutments and<br />

related components, or the various materials like BruxZir ® and<br />

our forthcoming product Obsidian , we seem to be blazing a<br />

new trail. Why? the others ask. Why won’t <strong>Glidewell</strong> just follow<br />

everyone else and stick to making standard restorations?<br />

Well, I could provide a number of reasons. Chief among them is the pursuit of knowledge. In our<br />

40-plus years, we have assimilated a wealth of it. You will find that we are unique. We understand<br />

the needs of both the patient and the clinician. We work with dentists every day to solve difficult<br />

cases that demand innovative restorative solutions. From that, we continue to develop a vast array<br />

of products that meet those needs.<br />

Our goal with this technology center is to emulate the efforts of world-class dental education facilities<br />

like the Pankey Institute and the Scottsdale Center, while focusing our offerings on practical,<br />

innovative solutions to everyday clinical challenges. This is not merely an implant sales facility, a<br />

materials-selling operation, or a means to highlight intraoral scanning and its digital progeny. Rather,<br />

it is our intent to share and advance the widespread knowledge of these and other advanced technologies<br />

and techniques for the fundamental purpose of making a positive difference in the lives of<br />

our patients and those of us who serve them.<br />

This center recognizes the extreme complexity of oral rehabilitation and the need for many different<br />

treatment modalities. It will have at its core an emphasis on all things digital: digital scanning, digital<br />

treatment planning, digitally processed surgical guides, digitally manufactured implant components<br />

and restorations, and the digital manufacture of final crown & bridge restorations — along with the<br />

digital compilation of all treatment data, with archive retrieval at one’s fingertips. This new digital era<br />

allows us to bring about more predictable results, increase the consistency and quality of restorations,<br />

and help improve the oral health of many who are now suffering.<br />

Whatever the direction these emerging technologies take, rest assured that we will be here to<br />

study them together. We may not have quite the square footage as some of the other well-known<br />

educational centers, but we intend to make every bit as big an impact on the industry. From this<br />

location, we aim to provide measurable, patient-related results that will do nothing less than change<br />

the direction of dentistry worldwide. We must believe that what we are doing is that important,<br />

because success starts with vision and requires a lot of hard work.<br />

James R. <strong>Glidewell</strong>, CDT<br />

President, CEO


GLIDEWELL<br />

INTERNATIONAL TECHNOLOGY CENTER<br />

Enjoy presentations on the most advanced dental technologies and techniques<br />

presented in multimedia format in our 40-seat interactive classroom auditorium.<br />

Observe live surgical and prosthetic procedures<br />

in our fully functional operatory and surgical<br />

suite featuring state-of-the-art dental equipment,<br />

including a PreXion 3D Cone Beam CT scanner.


Sign up for a course today!<br />

Take part in intensive hands-on<br />

surgical and prosthetic workshops<br />

exploring the latest techniques<br />

taught by experienced<br />

clinicians and technicians.<br />

Learn what’s new in virtual design and CAD/CAM technology, and<br />

how to smoothly integrate these innovations into your practice.


Date Course Name Instructor Course # Tuition<br />

August<br />

3 Ten Keys for Grafting Success Dr. Sascha Jovanovic B111-110803 $49<br />

4<br />

To See, or Not to See, That Is the Question:<br />

Exploring Relationships of CBCT Liability,<br />

Accurate Diagnosis and Image Resolution<br />

(sponsored by PreXion)<br />

Dr. Sanjay Mallya A116-110804 $49<br />

12 The Modern Restorative Practice Dr. Michael DiTolla C110-110812 $99<br />

19<br />

20<br />

15<br />

23<br />

9/30–10/1<br />

Rehabilitating the Atrophic Edentulous<br />

Patient Using Small-Diameter Implants<br />

Rehabilitating the Atrophic Edentulous<br />

Patient Using Small-Diameter Implants<br />

State-of-the-Art Impressions<br />

and Digital Restorative Dentistry<br />

Using the IOS FastScan ® System<br />

The Fundamentals of Oral<br />

Appliance Therapy for Sleep Apnea<br />

Medical Billing for the Comprehensive<br />

<strong>Dental</strong> and Surgical Practice<br />

September<br />

October<br />

Dr. Paresh Patel B112-110819 $395<br />

Dr. Paresh Patel B113-110820 $395<br />

Dr. Michael DiTolla A118-110915 $49<br />

Dr. Todd Morgan E110-110923 $299<br />

Dr. Olya Zahrebelny D111-110930 $900/$750<br />

7 The Modern Restorative Practice Dr. Michael DiTolla C111-111007 $99<br />

8<br />

The Use of CAD/CAM for<br />

Custom Abutments for Technicians<br />

Alec Di Lullo/<br />

Shawn Ramirez<br />

G110-111008 $99<br />

14–15<br />

Treating the Edentulous Patient: The Quest<br />

for Beauty and Functional Excellence (Part 1)<br />

Dr. Burton Melton C112-111014 $300<br />

19 Implant Surgery for the <strong>Dental</strong> Assistant TBD F110-111019 $49<br />

November<br />

3 PreXion (course specifics coming soon) TBD A119-111103 TBD<br />

10<br />

11–12<br />

State-of-the-Art Impressions<br />

and Digital Restorative Dentistry<br />

Using the IOS FastScan ® System<br />

Treating the Edentulous Patient: The Quest for<br />

Beauty and Functional Excellence (Part 2)<br />

Dr. Michael DiTolla A120-111110 $49<br />

Dr. Burton Melton C113-111111 $300<br />

18 Digital Implant Treatment Planning Workshop Dr. Bradley Bockhorst B114-111118 $49<br />

December<br />

2<br />

3<br />

Rehabilitating the Atrophic Edentulous<br />

Patient Using Small-Diameter Implants<br />

Rehabilitating the Atrophic Edentulous<br />

Patient Using Small-Diameter Implants<br />

Dr. Paresh Patel B115-111202 $395<br />

Dr. Paresh Patel B116-111203 $395<br />

Please visit www.glidewellce.com for the most up-to-date course details and to register.


A New Generation of Denture Teeth<br />

The Perfect Route to<br />

Esthetic and Functional Dentures<br />

PRODUCT<br />

SPOTLIGHT<br />

by Thorsten Michel, MDT<br />

Introduction<br />

When fabricating removable dentures, finding suitable anterior teeth that provide the<br />

superior esthetics very discerning patients demand can prove challenging. To meet the<br />

requirements of an individual case, prefabricated denture teeth must very often be modified<br />

to incorporate age- and indication-related characteristics. This challenge led me to look for<br />

a solution to this problem. The purpose of this article is to summarize my experience with,<br />

and provide insight into, the development process that led to the creation of SR Phonares ®<br />

denture teeth from Ivoclar Vivadent.<br />

Figures 1, 2: Outstanding overall esthetics of the anterior teeth<br />

36<br />

– www.inclusivemagazine.com –


Discussion<br />

Figure 3: Natural facial design<br />

Figure 4: Natural palatal design<br />

Starting the process involved modeling upper<br />

and lower tooth molds that were a reflection<br />

of their natural counterparts. These molds<br />

featured all the special characteristics missing<br />

from existing prefabricated denture teeth<br />

(Figs. 1, 2). It is the first impression, the overall<br />

esthetic appearance that is conveyed in the first<br />

few seconds in which a tooth is viewed, that<br />

counts. These first few seconds are of crucial<br />

importance because this is the time it takes<br />

someone to decide whether the tooth lives<br />

up to his or her expectations. In order to<br />

achieve a natural esthetic outcome, lifelike<br />

tooth molds with facial and palatal surfaces that<br />

feature a truly anatomical design and impart<br />

an impression of natural dentition are essential<br />

(Figs. 3–6).<br />

The objective in modeling esthetic tooth molds<br />

is to achieve a vibrant but not overly exaggerated<br />

facial texture and a practical palatal and<br />

lingual design, which supports clear speech and<br />

phonetics rather than hampering it. In addition,<br />

anterior teeth that have a harmonious, layered<br />

Figure 5: Example of a naturally designed palatal aspect<br />

Figure 6: Silver powder discloses details of the exemplary palatal design.<br />

In order to achieve a<br />

natural esthetic<br />

outcome, lifelike tooth<br />

molds with facial and<br />

palatal surfaces that<br />

feature a truly<br />

anatomical design and<br />

impart an impression<br />

of natural dentition<br />

are essential.<br />

– A New Generation of Denture Teeth: The Perfect Route to Esthetic and Functional Dentures – 37


Another important<br />

aspect is to have a<br />

comprehensive range<br />

of molds from which<br />

to choose … This led to<br />

the development of<br />

age-related tooth molds.<br />

design and selectively incorporated opalescent<br />

and translucent areas, which impart a lifelike<br />

appearance, are preferred (Figs. 7, 8).<br />

Figure 7: Example of a harmonious layering and a natural-looking opalescent<br />

effect<br />

Another important aspect is to have a comprehensive<br />

range of molds from which to choose.<br />

To meet this requirement, I incorporated several<br />

tooth characteristics that can also be found<br />

in nature. This led to the development of agerelated<br />

tooth molds, which take into account<br />

the needs of patients at different stages in life.<br />

This allows for the selection of tooth molds<br />

based on an individual patient’s age.<br />

There are three simple steps for choosing<br />

suitable tooth molds. First, the basic shape is<br />

selected, based on whether the teeth should<br />

have a more youthful or distinctive look. Then<br />

the desired degree of wear is chosen. In this<br />

respect, both the incisal and facial curvature are<br />

of importance. While teeth with more rounded<br />

incisal edges and a pronounced facial curvature<br />

are designed for use in young patients (Fig. 9),<br />

those with more heavily abraded incisal edges<br />

and a flatter facial curvature are suitable for patients<br />

in the more advanced age group (Fig. 10).<br />

These features are based on the natural aging<br />

process that occurs in the oral cavity over time.<br />

In the third and last step, the size or dimension<br />

of each tooth is determined using a diagnostic<br />

cast of the case. For this purpose, the teeth<br />

are classified into “small,” “medium” and “large”<br />

categories. Tooth molds for smaller and larger<br />

alveolar ridges are available.<br />

Figure 8: The vibrant facial texture meets the highest esthetic demands<br />

Figure 9: A rounded tooth shape and lighter shades for younger patients<br />

38<br />

– www.inclusivemagazine.com –


Removable dentures should<br />

provide optimum “white<br />

esthetics.” This is especially<br />

true for implant-borne<br />

removable dentures.<br />

Figure 10: More distinctive tooth molds and darker shades for patients in the<br />

more advanced age group<br />

In a time when the focus is on esthetic dentistry, removable<br />

dentures should provide optimum “white esthetics”<br />

(Fig. 11). This is especially true for implant-borne<br />

removable dentures because all parties involved (i.e., the<br />

patient, clinician and dental lab technician) place high<br />

expectations on the esthetic outcome and function of<br />

this complex and expensive type of restoration.<br />

In order to achieve ideal “white esthetics,” the interproximal<br />

contours of anterior teeth should allow for the teeth<br />

to be lined up very closely without creating the impression<br />

of a “white wall.” The proximal “Set & Fit” design<br />

of SR Phonares denture teeth allows teeth to be set up<br />

in diverse positions, without producing open gingival<br />

embrasures, or “black triangles,” that then need to be<br />

filled with denture base material. Even when dealing<br />

with highly rotated teeth, a natural-looking tooth setup<br />

can be accomplished (Fig. 12).<br />

Creating a soft transition between the clinical crown<br />

and the tooth neck section optimizes the esthetics, as it<br />

facilitates modeling of the gingival contours. Placing a<br />

wax layer that tapers toward the cervical portion of the<br />

clinical crown creates the impression of naturally grown<br />

gingival tissue.<br />

To effectively cover a frame and implant abutments, a<br />

cervical design that accommodates implant abutments<br />

with an emergence profile of approximately 5 mm in<br />

diameter was also created. In most cases, no adjustments<br />

with tooth-colored material are required in the proximal<br />

anterior regions.<br />

Figure 11: Unparalleled “white esthetics”<br />

The proximal “Set & Fit”<br />

design of SR Phonares<br />

denture teeth allows teeth<br />

to be set up in diverse<br />

positions, without producing<br />

open gingival embrasures,<br />

or “black triangles.”<br />

Figure 12: Ideal proximal closure due to “Set & Fit” design<br />

– A New Generation of Denture Teeth: The Perfect Route to Esthetic and Functional Dentures – 39


In addition to their advanced anterior tooth design, SR<br />

Phonares denture teeth are characterized by extraordinarily<br />

high wear resistance, thanks to their Nano Hybrid<br />

Composite (NHC) material composition. Due to the<br />

fact that implants are firmly anchored to the alveolar<br />

bone, materials of extremely high strength are required<br />

in the fabrication of implant-borne removable dentures.<br />

As these dentures are not supported by soft tissue,<br />

masticatory forces are transferred completely to the materials<br />

used in the restorative process, which exposes<br />

them to very high levels of stress. SR Phonares NHC<br />

anterior tooth molds are not exclusively indicated for<br />

implant-borne dentures, however. They are perfectly<br />

suited for complete and partial denture prosthetics.<br />

SR Phonares Denture Teeth<br />

Q&A<br />

Courtesy of Dr. Frank Lauciello, Ivoclar Vivadent<br />

SR Phonares denture<br />

teeth are characterized<br />

by extraordinarily high<br />

wear resistance, thanks<br />

to their Nano Hybrid<br />

Composite (NHC)<br />

material composition.<br />

Conclusion<br />

Ivoclar Vivadent’s SR Phonares denture teeth closely replicate<br />

the shape and surface texture of natural dentition.<br />

The teeth feature a harmonious four-layer design and<br />

exhibit natural opalescence and fluorescence. Their new<br />

NHC material has been proven to provide high durability<br />

and excellent resistance to wear and plaque accretion.<br />

SR Phonares denture teeth also feature a well-balanced<br />

labial and palatal design. Due to their specially designed<br />

interdental closures, a natural-looking appearance of the<br />

denture can be achieved with ease. These denture teeth<br />

allow the dental technician to achieve precise, highquality<br />

results with minimal effort or difficulty.<br />

Q: Why did Ivoclar develop SR<br />

Phonares denture teeth?<br />

A: SR Phonares NHC denture teeth were developed<br />

in response to market demands for higher<br />

esthetics and wear resistance in complete, partial<br />

and implant-retained denture prostheses.<br />

500<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

In vitro wear study of denture tooth materials<br />

Pin-on-block with steatite antagonist, after 120,000 cycles<br />

NHC material<br />

SR<br />

Phonares<br />

Isosit<br />

Highly crosslinked<br />

PMMA<br />

Cross-linked<br />

PMMA<br />

Source: Dr. Dipl. Ing. (FH) Martin Rosentritt, 08/2009, University of Regensburg.<br />

Q: What are the benefits of a<br />

composite tooth?<br />

A: Ivoclar Vivadent spent several years developing<br />

its Nano Hybrid Composite, a unique material<br />

that yields true-to-nature esthetics and<br />

increased wear resistance over conventional<br />

resin materials. This new technology provides<br />

the opportunity for clinicians and technologists<br />

to prescribe and create truly esthetic<br />

removable restorations with long-term results.<br />

40<br />

– www.inclusivemagazine.com –


SOFT<br />

PMMA Clusters<br />

BOLD<br />

YOUTHFUL<br />

UNIVERSAL<br />

Q: How does this new<br />

generation of Nano Hybrid<br />

Composite bond to resin<br />

denture base materials?<br />

A: The unique properties of the NHC material<br />

yield good bonding results. The<br />

NHC material has inclusions of PMMA<br />

(polymethylmethacrylate) material that<br />

promotes bond strength and durability.<br />

The highest bond strengths have been<br />

recorded when processed with the SR<br />

Ivocap Injection System.<br />

MATURE<br />

SR Phonares denture teeth are available<br />

as a premium option on all conventional<br />

dentures, partials, overdentures and<br />

screw-retained dentures from <strong>Glidewell</strong><br />

Laboratories (Newport Beach, Calif.).<br />

Q: How were the molds<br />

developed?<br />

A: Like the NHC material, the SR Phonares<br />

anterior molds were a new development.<br />

Each mold was artfully designed<br />

to express individual patient characteristics<br />

(“soft” or “bold”) and age (“youthful,”<br />

“universal” or “mature”).<br />

– A New Generation of Denture Teeth: The Perfect Route to Esthetic and Functional Dentures – 41


Ensuring a Successful Restorative Outcome<br />

Utilizing BioTemps ® Implant Provisionals<br />

Go online for<br />

in-depth content<br />

by Ara Nazarian DDS, DICOI<br />

Although widely utilized in conventional crown & bridge applications, provisional restorations have traditionally<br />

been underused in implant therapy. Time-intensive surgical procedures may make the dentist and<br />

patient reluctant to dedicate additional chairtime to the proper fabrication of a “mere temporary.” This unfortunate attitude<br />

often ends up costing even more time and expense at subsequent appointments, and can cause the overall quality of the<br />

final restoration to suffer. A properly planned provisional can serve a variety of functions critical to the long-term success<br />

of an implant case. With the convenience and affordability of provisional splinted crowns and full-arch bridges such as<br />

BioTemps ® Implant Provisionals (<strong>Glidewell</strong> Laboratories; Newport Beach, Calif.), clinicians owe it to their patients to<br />

educate them regarding the multiple benefits of incorporating a provisional solution in the overall treatment plan.<br />

Provisional restorations may be fixed or removable and are made from a variety of materials. The most common forms of<br />

temporary restorations are fixed bridges supported by retained natural teeth, resin-bonded bridges and removable temporary<br />

partials, or flippers. BioTemps represent a fixed solution because they can be cemented or screw-retained. The decision<br />

to use a provisional restoration and which type to use depends greatly on the patient’s specific needs and preferences. At<br />

its simplest, a provisional serves as the interim prosthesis while implants heal and a definitive restoration is fabricated. But<br />

if its effectiveness is maximized, a provisional restorative prosthesis provides four principal benefits:<br />

1. Protects the underlying implants or bone-grafted sites from direct occlusal loads<br />

The long-term success of any implant-borne restoration depends heavily on the integration of the supporting implant.<br />

A proper provisional must therefore protect the surgical site from occlusal forces during the healing process, preventing<br />

micro-movement of the implant and any associated bone grafts. BioTemps are designed to seat passively over healing areas,<br />

shielding them from stresses that might adversely affect osseointegration. When a pontic span exceeds three units, a cast-metal<br />

substructure is indicated, giving the provisional additional strength. Wire or Kevlar ® fiber reinforcement (DuPont; Wilmington,<br />

Del.) is also available.<br />

2. Protects the underlying gingival tissues<br />

Along with preserving bone health, a provisional must protect its underlying gingival tissues. BioTemps not only preserve<br />

tissue, but they can also be used to shape the associated soft tissue during the maturation phase. They have been shown to<br />

promote contoured healing for ovate pontics or anterior extractions, and can help shape the sulcus around implants. The<br />

ability to manage and sculpt the surrounding soft tissue leads to greater predictability in the seating of the final prosthesis.<br />

This is particularly helpful in the esthetic zone, where elements such as gingival margins and contours, papilla, and final<br />

emergence profile play a key role in replicating the proper morphology of natural dentition.<br />

3. Determines the future position, support, shape and shade of the final prosthesis<br />

Beyond helping to establish the health and shape of the supportive tissues, a provisional restoration can act as the<br />

blueprint for the final prosthesis. The restorative dentist is therefore able to obtain a hands-on feel for the eventual<br />

solution using a working prototype in the actual oral environment. Every aspect of form, fit and function can be<br />

evaluated. As an example, screw-retained BioTemps over implants can help create a predictable path of insertion, on<br />

which many other elements are based. And it’s not just the dentist who will appreciate this “trial run.” By experiencing his<br />

– Ensuring a Successful Restorative Outcome Utilizing BioTemps Implant Provisionals – 43


or her restoration on an interim basis, the patient is<br />

given a chance to assess it before undergoing placement<br />

of the definitive prosthesis. If either dentist or patient<br />

is dissatisfied with the provisional in any way, the<br />

appropriate adjustments can be made. Once approved,<br />

dimensions and morphology can be precisely transferred<br />

to the laboratory via impression for use in the fabrication<br />

of the final restoration, increasing the likelihood of patient<br />

acceptance during that final visit.<br />

4. Restores and enhances esthetics and phonetics<br />

Patient acceptance of any prosthesis is generally determined<br />

by both esthetics and function. If the prosthesis is<br />

unesthetic, inhibits accustomed phonetics, or otherwise<br />

fails to function in accordance with the patient’s expectations,<br />

then he or she is likely to experience dissatisfaction.<br />

There is little excuse for this in an implant case, where<br />

the restoration is designed “from the ground up” and is<br />

therefore less likely to face the constraints of preexisting<br />

structures. Natural or wear-related imperfections such as<br />

diastemas or limited vertical dimension can be corrected<br />

with the provisional just as they can with the final restoration.<br />

Using a provisional to test and determine acceptable<br />

morphology enables the dentist and patient to verify overall<br />

appearance and function. Once again, any required<br />

adjustments can easily be made chairside to the provisional<br />

and then reflected in the final restoration.<br />

With all that provisionals can contribute, the question becomes,<br />

why forego their inclusion in treatment planning<br />

dental implants? One reason is that provisional restorations<br />

are often left until the end of an appointment, when time<br />

is limited. But time spent in their construction is more than<br />

repaid in time saved doing additional procedures, adjustments<br />

and remakes in the future. This is especially true of a<br />

provisional like BioTemps, which can be prefabricated from<br />

an impression or preoperative model and delivered prior to<br />

surgery for a simple, efficient chairside reline.<br />

Another reason given for avoiding provisionals is the notion<br />

that they are merely a short-term solution; however, implant<br />

healing times can require weeks or months, particularly if<br />

bone grafts are prescribed. Does the patient really wish to<br />

tolerate inadequate esthetics or decreased function for this<br />

prolonged period?<br />

A third complaint is the associated expense of a provisional.<br />

Given the high costs of many implant procedures, customers<br />

may look to trim those costs wherever possible, and a<br />

“disposable” temporary may appear to be a good place to<br />

start. However, a patient concerned with the affordability of<br />

a provisional should consider the affordability of not using<br />

one. What are the possible costs of a treatment plan lacking<br />

a suitable provisional aspect? BioTemps over implants are<br />

reasonably priced and present an exceptional value to many<br />

patients, once they understand the overall manner in which<br />

these provisionals can contribute to the success of their case.<br />

To maximize their effectiveness, provisional restorations<br />

should be carefully planned prior to the surgical phase.<br />

Various techniques are available to achieve optimal protection<br />

and continued function without compromising<br />

esthetics. Working together, the restorative dentist and the<br />

laboratory should determine which techniques best fulfill<br />

the specific requirements of each case. Proper management<br />

will contribute to satisfying the patient’s expectations and<br />

help ensure a successful final solution.<br />

A well-designed provisional restoration is predicated upon<br />

four key factors:<br />

1. The ultimate restorative plan<br />

The objective of an implant-supported prosthesis is to provide<br />

a functional and cosmetically acceptable form of<br />

tooth replacement. Every aspect of a provisional prosthesis<br />

should contribute to the realization of this ultimate goal.<br />

Anything that might counteract, marginalize or degrade<br />

the quality of the definitive restoration should be avoided.<br />

2.The number and location of the dental implants<br />

Implants serve as the foundation for any implant-borne<br />

restorative solution. Thus, any provisional must properly<br />

consider the structural framework on which it will be laid.<br />

For example, it was mentioned earlier that wire, fiber or<br />

cast-metal reinforcement is recommended in BioTemps<br />

provisional restorations with a pontic span greater than<br />

three units. Occlusal forces and potential bone stress are<br />

also critical factors that are deeply affected by the underlying<br />

implant configuration.<br />

3. The bone quality and quantity<br />

Just as an implant-borne restoration is only as reliable<br />

as the implants on which it is placed, the success of those<br />

implants is only as reliable as the overall health of the<br />

surrounding osseous tissue. Bone lacking in quality or<br />

quantity may require special consideration such as severe<br />

implant angulation or grafting procedures, which may in<br />

turn dictate certain aspects of both the provisional and the<br />

definitive restoration.<br />

4. The needs and desires of the patient<br />

The success of a restorative prosthesis relies heavily on the<br />

perception of the receiving patient. An unhappy patient<br />

makes for an unhappy dentist. While it is the dentist’s<br />

responsibility to educate and advise the patient as to all<br />

options and considerations related to the case, the obligation<br />

to listen to and accept the patient’s stated goals and<br />

preferences remains. This applies to all aspects of the treatment<br />

plan, and the role of a provisional is no exception.<br />

44<br />

– www.inclusivemagazine.com –


CASE 1<br />

The following case depicts the utilization of BioTemps as a full maxillary implant-supported,<br />

screw-retained provisional restoration.<br />

Figure 1: Preoperative smile view depicting unattractive smile<br />

Figure 2: Preoperative occlusal view of maxillary arch<br />

Figure 3: Occlusal view of healed maxillary arch after extractions<br />

Figure 4: Atraumatic placement of eight dental implants<br />

Figure 5: Screw-retained maxillary BioTemps placed and access holes covered<br />

Figure 6: Postoperative smile using BioTemps Implant Provisionals<br />

– Ensuring a Successful Restorative Outcome Utilizing BioTemps Implant Provisionals – 45


CASE 2<br />

The following case depicts a cemented BioTemps provisional restoration.<br />

Figure 1: Preoperative view of patient with missing lateral incisors<br />

Figure 2: Implants prior to abutment preparation<br />

Figure 3: Prepared natural central incisors and lateral implant abutments<br />

Figure 4: Relined BioTemps provisional restoration in place<br />

Conclusion<br />

BioTemps Implant Provisionals can play a valuable role in managing clinical situations to ensure success with the final<br />

prosthesis. They can be used to evaluate esthetic, phonetic and occlusal function prior to delivery of the final implant restorations,<br />

while preserving or enhancing the condition of the peri-implant and gingival tissues. They provide patients with<br />

natural-looking temporaries at any stage of implant treatment, and serve as an excellent prototype by which to evaluate<br />

shade and contours, leading to greater patient acceptance and a superior definitive restoration. They are also useful as a<br />

communication tool between members of the treatment team, which in many cases consists of the restorative clinician,<br />

implant surgeons, dental laboratory technicians and the patient. Clinicians should be aware of the different types of provisional<br />

restorations and their indications for use when planning implant-retained restorations. If planned and fabricated<br />

properly, this temporary prosthesis can become an integral part of the overall restorative solution.<br />

46<br />

– www.inclusivemagazine.com –


Preserving the Integrity<br />

of Facial Structures with<br />

Implant-Retained Overdentures<br />

Go online for<br />

in-depth content<br />

by Timothy F. Kosinski, DDS, MAGD<br />

The Centers for Disease Control and Prevention<br />

(CDC) has reported that by age 50, Americans<br />

have lost an average of 12 teeth and, among adults aged<br />

65 to 74 years, 26 percent are completely edentulous. Care of<br />

the edentulous patient has been changed by the emergence of<br />

implant-supported restorations, which are a viable alternative<br />

to traditional denture fabrication. However, there are still many<br />

general practitioners who have not committed to making dental<br />

implant treatment a significant part of their practice. They may<br />

let potential drawbacks such as surgical or prosthetic training,<br />

perceived cost, concern about the profitability of implant cases,<br />

or lack of insurance coverage stand in their way of providing<br />

innovative and successful dental implant treatment services to<br />

their patients.<br />

Implant manufacturers and dental laboratories such as <strong>Glidewell</strong><br />

Laboratories (Newport Beach, Calif.) are presenting product<br />

innovations that have made implant dentistry simpler for dentists<br />

restoring implants and easier for patients receiving implant<br />

therapy. Implant placement and immediate implant function<br />

have become popular as long as there is an absence of infection,<br />

and adequate bone quantity and quality. These innovations<br />

make implant dentistry more attractive to both patients and the<br />

restorative dentist.<br />

As clinicians, it is imperative that we educate and counsel our<br />

patients as to the benefits of quality care irrespective of insurance<br />

benefits or financial limitations. A patient should be made<br />

aware of all available options without tailoring discussion solely<br />

to his or her dental insurance benefits. We should encourage<br />

the best overall care plan and provide alternatives to treatment<br />

in order of most effective to least effective, including no treatment<br />

at all.<br />

48<br />

– www.inclusivemagazine.com –


Many people are unaware of the relationship between their teeth and the bone that supports them. Along with<br />

the maxillary and mandibular bone, teeth provide the support for facial contours. Changes in these structures,<br />

then, will cause changes in facial features. The loss of teeth can result in wrinkles around the mouth and lips<br />

and the collapse of facial structures, causing an overall “caved-in” appearance. When teeth are absent over a<br />

prolonged period of time, the bone that supported these teeth will gradually resorb. <strong>Dental</strong> implants can preserve<br />

the integrity of facial structures by minimizing this bone resorption. The implants act like natural teeth in<br />

that they provide stress to the bone, which helps stimulate blood flow and maintain the existing bone contours.<br />

<strong>Dental</strong> implants are thus used to create a more stable foundation for replacement teeth, whether they are used<br />

under removable or fixed appliances.<br />

Maintaining the natural appearance of the face and smile can be challenging, but dental implants have proven<br />

to be an excellent starting point compared to conventional complete dentures. For one, the generation of baby<br />

boomers does not like to look and feel old. When the corners of the mouth droop, wrinkles appear around the<br />

lips and the distance between the nose and chin decreases, esthetics are compromised. Second, even well-fitting<br />

dentures result in a decrease in natural chewing function, which may in turn lead to digestive issues resulting in<br />

a myriad of potential health issues. Third, while conventional dentures do serve the basic purpose of replacing<br />

missing teeth and providing structural support to the lips, they may actually accelerate the resorption process<br />

by pressing down on the gingiva and underlying bone as the wearer eats. Regardless, the inevitable, continued<br />

bone loss will cause the facial structures to further collapse over time, necessitating prosthetic relines to compensate<br />

for the physical changes.<br />

This article aims to demonstrate just a few of the prosthetic options available today in restoring form and<br />

function using dental implant-retained overdentures. Our hope with these designs is to dramatically enhance<br />

our patients’ quality of life by achieving one or more of the following goals: to preserve the integrity of facial<br />

structures not only immediately but over time, restore the mouth area to as natural a state as possible, increase<br />

stability and the patient’s sense of security that his or her teeth will not become dislodged or fall out during<br />

basic activities (eating, laughing, sneezing, kissing), improve physical appearance, improve health by facilitating<br />

proper digestion and nutrition, improve the taste of food, eliminate the need for denture adhesives, and improve<br />

self-confidence and self-esteem.<br />

To reiterate, the advantages of conventional complete dentures is that they restore some basic tooth function<br />

in edentulous situations and provide lip support. Disadvantages include accelerated bone resorption, relatively<br />

frequent replacement or relines, and the inability to eat some foods properly, affecting digestion and overall<br />

health. <strong>Dental</strong> implant-supported overdentures, however, provide greater comfort and stability than conventional<br />

dentures, and they do a better job of restoring lip support, maintaining facial structures and minimizing<br />

bone resorption.<br />

The fabrication of any stable removable appliance begins with careful diagnosis and case planning. Regardless<br />

of the patient’s age, it is imperative that his or her concerns and desires be taken into account in order to<br />

make the final prosthesis acceptable. Improving form and function can be a difficult challenge in any complete<br />

denture situation. Fortunately, implants represent an outstanding treatment option for dramatically improving<br />

denture stability and increasing chewing ability. Endosseous implant designs have proven to offer an excellent<br />

prognosis and are reliable retainers for overdentures.<br />

<strong>Dental</strong> implant-supported overdentures …<br />

provide greater comfort and stability than<br />

conventional dentures, and they do a better<br />

job of restoring lip support, maintaining facial<br />

structures and minimizing bone resorption.<br />

– Preserving the Integrity of Facial Structures with Implant-Retained Overdentures – 49


Figure 1: Pre-op smile with conventional maxillary complete<br />

denture in position<br />

Case 1<br />

The first case demonstrated here involves a female patient who<br />

had worn a conventional maxillary complete denture for more<br />

than 20 years. Opposing the conventional maxillary denture<br />

was an implant-retained mandibular overdenture that had also<br />

been in place for many years. Having appreciated the stability<br />

and function of the mandibular overdenture, she had requested<br />

investigation of a similar prosthesis in the maxilla. This desire<br />

increased over time because her maxillary denture needed to<br />

be relined several times, and the form and function of her existing<br />

conventional denture diminished. The patient exhibited no<br />

significant medical concerns other than severe horizontal bone<br />

loss in the premaxillary area. Ridge augmentation had been discussed<br />

many times in the past, but the invasive procedure had<br />

always been declined.<br />

Current options were discussed with the patient, including fabrication<br />

of a new conventional denture and ridge augmentation<br />

procedures followed by dental implant therapy. The patient<br />

elected a simple approach in the surgical placement of four<br />

dental implants in the posterior maxilla. The surgical design<br />

was determined with CT diagnosis and placement using a CT<br />

surgical stent. The implant planning software was used to visualize<br />

the patient’s entire mouth anatomy in three dimensions.<br />

The computer software accurately simulated the placement of<br />

dental implants prior to ever touching the patient. We found adequate<br />

bone in the posterior maxilla, but not acceptable bone in<br />

the anterior maxilla. This implant planning and placement software<br />

provided a high level of comfort and safety for the patient,<br />

reducing surgical and restorative time by giving us an accurate<br />

3-D plan prior to implant placement.<br />

Figure 1 illustrates the closed vertical dimension of occlusion.<br />

Figure 2 illustrates the postoperative CT scan, showing proper<br />

positioning of the four dental implants. Conventional techniques<br />

Figure 2: Post-surgical CT scan illustrating final position of<br />

integrated dental implants<br />

Implant planning and placement<br />

software provided a high level<br />

of comfort and safety for the<br />

patient, reducing surgical and<br />

restorative time by giving us<br />

an accurate 3-D plan prior to<br />

implant placement.<br />

Figure 3: Conventional occlusal rim positioned to increase<br />

the vertical dimension of occlusion<br />

50<br />

– www.inclusivemagazine.com –


were used to visualize tooth position using stable record bases<br />

and occlusal rims. The intent was to increase the vertical dimension<br />

to give the patient a younger look (Fig. 3). Anterior teeth<br />

were set to the desired esthetics. Following integration of the<br />

implants, accurate impressions of the fixtures were taken intraorally<br />

using traditional impression copings splinted together<br />

with acrylic. The intent was to maximize the stability of the<br />

impression technique (Fig. 4). The stable record base with anterior<br />

teeth waxed into position was hollowed out (Fig. 5) and<br />

an impression made with polysiloxane materials (Fig. 6). The<br />

laboratory then created an extremely accurate master cast with<br />

tissue approximations (Fig. 7).<br />

In this case, Locator ® attachments (Zest Anchors; Escondido,<br />

Calif.) were used as the retentive devices for a maxillary, horseshoe-shaped<br />

overdenture. Because of the posterior position of<br />

the implants and the relatively porous quality of the bone in the<br />

area, I considered placing a cross-arch bar splint with attachments<br />

to retain the overdenture. However, a careful evaluation<br />

incorporating the esthetic concerns of the patient resulted in an<br />

inability to increase the vertical dimension of occlusion excessively.<br />

It was therefore determined that there was not enough<br />

intraocclusal space to provide for proper bar fabrication — not<br />

while maintaining the preferred esthetics. The use of Locator<br />

attachments eliminated my concern with intraocclusal distance<br />

and final esthetics (Fig. 8). These attachments resist wear and<br />

maintain satisfactory retention for up to 56,000 cycles of function.<br />

This system proved appropriate where occlusal clearance<br />

became an issue. The Locator attachments come in a variety<br />

of retention strengths, from extra light to heavy. This type of<br />

prosthesis allowed for excellent retention and stability for this<br />

patient. The attachments were positioned extracoronally to<br />

allow for good tissue adaptation and easy maintenance with a<br />

toothbrush or end-tufted brush.<br />

Figure 4: Splinted impression copings<br />

Figure 5: Hollowed-out record base used to pick up the<br />

splinted impression copings<br />

Figure 9 illustrates the underside of the palateless maxillary<br />

implant-retained overdenture with the Locator attachments. Note<br />

that a cast framework was incorporated to provide strength to<br />

the prosthesis and secondary splinting of the implants. Figure 10<br />

shows how the palate is exposed, allowing for better tasting of<br />

A cast framework was<br />

incorporated to provide<br />

strength to the prosthesis<br />

and secondary splinting<br />

of the implants.<br />

Figure 6: Final, accurate pickup impression using polysiloxane<br />

materials<br />

Figure 7: Accurate master cast<br />

– Preserving the Integrity of Facial Structures with Implant-Retained Overdentures – 51


food and elimination of the gag reflex, yet still providing outstanding<br />

stability and retention. Figure 11 illustrates our final<br />

smile design, which created a younger look for the patient. This<br />

patient exhibited a positive end result because of her understanding<br />

of the limiting factors involved in this case and her desire<br />

to limit more aggressive, invasive surgical procedures. However,<br />

she was made aware that bone loss was continuing in her maxilla<br />

and appreciated our attempt to minimize that bone loss in<br />

the future. Her chewing function was deemed more efficient,<br />

and her speaking was excellent. The patient no longer worried<br />

about her prosthesis slipping or loosening during function.<br />

Figure 8: Locator attachments seated intraorally<br />

Figure 9: Underside of palateless implant-retained maxillary<br />

overdenture with Locator attachments precisely positioned<br />

Figure 10: Intraoral occlusal view of palateless overdenture<br />

Case 2<br />

The second case demonstrated here involves a woman who had<br />

had conventional maxillary and mandibular complete dentures<br />

for many years. Because of the lack of horizontal bone thickness,<br />

conventional dental implant placement would be difficult.<br />

However, the patient’s quality of life was diminished because<br />

her conventional mandibular denture was unstable and had<br />

begun to create functional problems. Small-diameter implants<br />

were chosen to restore stability in a mandibular overdenture<br />

due to their size. Four small-diameter implants were surgically<br />

placed in the symphysis without complication. CT diagnosis<br />

and a CT surgical stent were used to ensure proper angulation<br />

and depth.<br />

Figure 12 illustrates the preoperative, narrow mandibular ridge<br />

responsible for the patient’s complaint. Figure 13 shows the<br />

parallel position of four small-diameter implants, which will<br />

be used to stabilize a new implant-retained overdenture. The<br />

I-Mini ® <strong>Dental</strong> Implant System (OCO Biomedical; Albuquerque,<br />

N.M.) used here incorporates a rather simple impression<br />

technique that utilizes plastic snap-on impression copings<br />

(Fig. 14). Vinyl polysiloxane impression material is injected<br />

around the pickup impression copings using a well-made custom<br />

tray (Fig. 15). Laboratory analogs are placed into the copings<br />

after removal from the mouth, to be used to fabricate an<br />

accurate master cast (Fig. 16). Simple O-ring attachments<br />

seated in metal housings serve as the retentive mechanism<br />

(Figs. 17a, 17b). Combining a new conventional maxillary complete<br />

denture with the patient’s very stable small-diameter<br />

mandibular implant overdenture improved her vertical dimension<br />

of occlusion and final esthetics (Fig. 18).<br />

Placing conventional-sized implants in this patient’s mandible<br />

would have been difficult, due to the minimal size of the alveolar<br />

crest. Small-diameter implants gave me an option to restore<br />

function and stability to the patient’s prosthesis. This treatment<br />

option represents a great service to a group of patients who<br />

may not otherwise experience the benefits of implant dentistry.<br />

Figure 11: Final smile design<br />

52<br />

– www.inclusivemagazine.com –


Figure 12: Severely resorbed mandibular ridge<br />

Figure 16: Laboratory analogs placed into the pickup copings<br />

for the fabrication of an accurate master cast<br />

Figure 13: Four small-diameter implants ideally positioned<br />

Figure 14: Impression pickup copings snapped into place<br />

Figures 17a, 17b: Conventional O-ring attachments provide<br />

retention for the overdenture<br />

Figure 15: Vinyl polysiloxane impression material used in an<br />

accurate custom tray to pick up the impression copings<br />

Figure 18: Final smile design with increased vertical dimension<br />

– Preserving the Integrity of Facial Structures with Implant-Retained Overdentures – 53


Case 3<br />

Our final case involves a completely edentulous patient who<br />

had never worn any type of prosthesis. Figure 19 illustrates<br />

the wrinkles present around the patient’s mouth and loss of<br />

lip support. Although in her forties, she looked and felt much<br />

older. Conventional dental implant surgical procedures were<br />

completed, with four implants placed in the edentulous mandible<br />

and five implants placed in the edentulous maxilla. At the<br />

time of surgery, it was determined that a sixth dental implant in<br />

the maxillary left cuspid area could not be predictably placed<br />

due to the thinness of the bone. A dental CT was not performed<br />

prior to this surgical intervention, so a typical flap procedure<br />

was used to allow for a more detailed visual examination of the<br />

subgingival structures during the placement procedure.<br />

A custom milled<br />

bar would be used,<br />

which would splint<br />

the maxillary implants<br />

and allow for<br />

fabrication of parallel<br />

attachments.<br />

After discussing prosthetic options with the patient, it was determined<br />

that removable implant-retained overdentures would<br />

provide her proper lip and tissue support, help maintain the<br />

quantity of bone in both arches over time and dramatically improve<br />

function. The patient had tried a conventional, full-palate<br />

maxillary complete denture, but was unable to tolerate it due<br />

to a severe gag reflex. This is another example of where it is<br />

imperative that we listen to the patient’s concerns and desires<br />

if we hope to make the final prosthesis acceptable. Doing so<br />

ensures the quality of life enhancement provided by dental implants<br />

will be rewarding to the dentist and gratifying to the<br />

patient.<br />

Following integration of the mandibular dental implants, a conventional<br />

impression was made by seating impression copings<br />

into the properly placed and parallel implants (Fig. 20) using a<br />

custom tray (Fig. 21). Due to the ideal positioning of the four<br />

mandibular implants, Locator attachments were used as the<br />

retentive mechanism for the overdenture. Because of their<br />

design, the patient is able to easily align and seat the overdenture<br />

into position. Figure 22 illustrates the four mandibular<br />

Locator attachments intraorally positioned. Figure 23 shows the<br />

intaglio surface of the overdenture with the four Locator housings<br />

and retentive male attachments. It was more difficult to<br />

parallel the five maxillary dental implants, and therefore it was<br />

determined that, rather than use single Locator attachments, a<br />

custom milled bar would be used (Fig. 24), which would splint<br />

the maxillary implants and allow for fabrication of parallel<br />

attachments to be built into the framework (Fig. 25). In<br />

the final analysis, we were able to predictably provide the<br />

patient dramatic improvement in esthetics, function and support<br />

for the facial soft tissue. Figure 26 illustrates the beaming smile<br />

of the very happy patient.<br />

54<br />

– www.inclusivemagazine.com –


Figure 19: Facial photograph of our third patient, who presented<br />

with complete edentulism<br />

Figure 23: Underside of the mandibular implant-retained<br />

overdenture showing the four Locator housings and retentive<br />

male attachments<br />

Figure 20: Impression copings placed intraorally<br />

Figure 24: Maxillary implant-retained custom milled bar<br />

Figure 21: Final impression with impression copings picked<br />

up using an open-tray technique<br />

Figure 25: Maxillary implant-retained overdenture<br />

Figure 22: Four mandibular Locator attachments ideally<br />

positioned<br />

Figure 26: Final esthetic result of maxillary and mandibular<br />

implant-retained overdentures<br />

– Preserving the Integrity of Facial Structures with Implant-Retained Overdentures – 55


Conclusion<br />

Follow-up care for implant-retained overdentures includes clinical<br />

assessment for abutment stability, mobility of the implants<br />

and plaque accumulation. Because the perimucosal seal is vital<br />

to protecting the underlying connective tissue, probing healthy<br />

implants is not advised. Radiographs should be taken yearly to<br />

determine bone position and contour. Metal scalers and ultrasonic<br />

instruments may damage the titanium abutment surface;<br />

therefore, plastic or graphite scalers are preferred.<br />

The general dentist has an obligation to provide patients with the<br />

most innovative and proven techniques available. CT scans and<br />

scanning software make surgical placement of implants rather<br />

routine. Anatomical anomalies are virtually determined before<br />

ever touching the patient. With good implant placement comes<br />

more routine and predictable prosthetic reconstruction. Because<br />

the general practitioner is the professional the patient consults<br />

with and trusts concerning their dental condition, all clinicians<br />

should educate themselves on the newest treatment modalities.<br />

56<br />

– www.inclusivemagazine.com –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!