<strong>Sensors</strong> <strong>and</strong> <strong>Accessories</strong> (English)<br />

Product Data Sheet<br />

00813-0100-2654, Rev GB<br />

April 2010<br />

TABLE 4. Series 68 RTD Sensor Assemblies WITHOUT Thermowell<br />

★ The St<strong>and</strong>ard offering represents the most common options. The starred options (★) should be selected for best delivery.<br />

__The Exp<strong>and</strong>ed offering is subject to additional delivery lead time.<br />

Assemble to Options<br />

St<strong>and</strong>ard<br />

St<strong>and</strong>ard<br />

XA (9) Assemble connection head or transmitter to a sensor assembly ★<br />

(1) Capsule style available in 1-in. increments only, starting at 1-in. (i.e. 1, 2, 3-inches, etc.) See “Mounting Adapters for Series 58, 68, 78, <strong>and</strong> 183” on page 66.<br />

(2) This option must be used with Sensor Lead Wire Termination code N <strong>and</strong> is not available with assembly code XA or with Approval codes E1, E5, E6, <strong>and</strong> E7.<br />

(3) General-purpose sensors are only available in (L) lengths of 2.5-in. or greater.<br />

(4) Spring loaded sensors must be installed in a thermowell assembly to meet the requirements of explosion-proof approvals code E6.<br />

(5) Not available with Sensor Lead Wire Termination codes R, P, or C or with approval codes E1, E5, E6, or E7.<br />

(6) 1-in. length without extension is only available in capsule style.<br />

(7) SAA Flame-proof Approval is only applicable if installed with <strong>Rosemount</strong> 248, 644, or 3144P transmitters.<br />

(8) These options are not available with Sensor Lead Wire Termination codes R, P, or W.<br />

(9) If ordering code XA with a transmitter, specify the same option on the transmitter model code.<br />

Ordering Example<br />

Typical<br />

Model<br />

Number<br />

Model<br />

Lead Wire<br />

Termination<br />

Sensor Type<br />

Extension<br />

Type<br />

Extension<br />

Length<br />

Thermowell<br />

Material<br />

Immersion<br />

Length<br />

Additional<br />

Options<br />

0068 N 11 N 00 N 045 E5<br />