<strong>Sensors</strong> <strong>and</strong> <strong>Accessories</strong> (English)<br />
Product Data Sheet<br />
00813-0100-2654, Rev GB<br />
April 2010<br />
Introduction<br />
OVERVIEW<br />
Emerson Process Management offers a wide variety of RTD <strong>and</strong><br />
thermocouple sensors that are available alone or as complete<br />
assemblies including connection heads, thermowells, <strong>and</strong><br />
extension fittings. In addition to complete assemblies, Emerson<br />
Process Management offers heads, coupling/nipple <strong>and</strong><br />
union/nipple extensions, compression fittings, <strong>and</strong> thermowells.<br />
Using this Product Data Sheet (PDS)<br />
Use this PDS to order complete temperature sensor assemblies,<br />
which include sensors, thermowells, extensions, <strong>and</strong> connection<br />
heads. These options can also be ordered separately. For<br />
example, you can order a thermowell, extension, or connection<br />
head for use with an existing sensor. In each case it is important to<br />
know <strong>and</strong> underst<strong>and</strong> the sections of this PDS when specifying the<br />
items.<br />
Threaded <strong>Sensors</strong> <strong>and</strong> Assemblies<br />
• Includes descriptions, specifications, <strong>and</strong> ordering information<br />
for Series 58C, 68, 68Q, <strong>and</strong> 78 RTDs, <strong>and</strong> the Series 183<br />
thermocouples.<br />
• Includes information for ordering sensors, connection heads,<br />
extensions, <strong>and</strong> thermowells as complete assemblies.<br />
Calibration<br />
• Includes characterization schedules <strong>and</strong> information for<br />
ordering calibrated Series 68, 68Q, <strong>and</strong> 78 RTD <strong>Sensors</strong>.<br />
• Includes information regarding the use of Callendar-Van<br />
Dusen constants to match specific Series 68, 68Q, <strong>and</strong> 78<br />
RTDs to <strong>Rosemount</strong> Smart <strong>Temperature</strong> Transmitters.<br />
Mounting <strong>Accessories</strong><br />
• Includes descriptions, specifications, <strong>and</strong> ordering information<br />
for temperature accessories such as thermowells, extensions,<br />
connection heads, mounting adapters, lead wire extensions,<br />
connectors, seals, <strong>and</strong> thermowells.<br />
Hazardous Area Approvals<br />
• Includes descriptions of the FM, CSA, SAA, <strong>and</strong> ATEX<br />
approvals for sensors <strong>and</strong> connection heads.<br />
Configuration Data Sheet<br />
• Provides a form used for thermowell application calculations.<br />
Series 58C, 68, 68Q, <strong>and</strong> 78 platinum RTD<br />
temperature sensors are primarily used when high accuracy,<br />
durability, <strong>and</strong> long-term stability are required. These sensors<br />
conform to international st<strong>and</strong>ards: IEC-751, EN 60751, <strong>and</strong> BS<br />
EN 60751. (1)<br />
Series 58C platinum RTD temperature sensors:<br />
• Combine an economical thin-film design with a sheath that<br />
can be shortened to any length with tubing cutter.<br />
Series 68Q Quick Response Sanitary RTD sensors:<br />
• Conform to 3–A Sanitary St<strong>and</strong>ards <strong>and</strong> feature product<br />
contact surfaces designed for CIP cleaning.<br />
Series 68 platinum RTD temperature sensors:<br />
• Provide high performance in an economical thin-film design.<br />
Series 78 platinum RTDs temperature sensors:<br />
• Use a wire-wound element which allows for a broader<br />
measurement range.<br />
Thermocouples<br />
Series 183 thermocouple temperature sensors conform to ASTM<br />
E-230, <strong>and</strong> are available in types J, K, E, <strong>and</strong> T.<br />
Series 183 thermocouple temperature sensors are available:<br />
• grounded or ungrounded<br />
• isolated or unisolated<br />
• with immersion lengths from 2 to 48 inches.<br />
(1) 100 ohms at 0 °C, = 0.00385 ohms/ohm/°C<br />