<strong>Sensors</strong> <strong>and</strong> <strong>Accessories</strong> (English)<br />

Product Data Sheet<br />

00813-0100-2654, Rev GB<br />

April 2010<br />

HOW TO DECIDE WHAT TO ORDER<br />

Start<br />

(Select One)<br />

Is a sensor <strong>and</strong> a<br />

thermowell needed?<br />

Is a sensor for an<br />

existing thermowell<br />

needed?<br />

Is a thermowell for an<br />

existing sensor<br />

needed?<br />

Yes<br />

Yes<br />

Yes<br />

Refer to Table 1. Do any<br />

st<strong>and</strong>ard lagging<br />

length/immersion length<br />

combinations meet the<br />

requirements?<br />

Select a sensor without a<br />

thermowell<br />

Select a thermowell<br />

Yes<br />

No<br />

Select a sensor with<br />

a thermowell<br />

combination<br />

1. Select a sensor<br />

without a thermowell<br />

combination<br />

2. Select a thermowell<br />

Finish<br />

If <strong>Rosemount</strong> sensor <strong>and</strong> model code is visible on the Sensor:<br />

1. If the thermowell is ordered separately (0078P23C30N060) 11th digit = ‘N’<br />

a. Start with immersion length - digits 12-14; 060 = 6.0 in.<br />

b. Add extension length - digits 9 & 10; 30 = 3.0 in. (3 + 6 = 9)<br />

Order the replacement sensor for the total length without connection heads (5th digit N) <strong>and</strong> extension (8th digit N) 0078N23N00N090<br />

2. If the thermowell is ordered integral to sensor (0078P23C30A060W40) 11th digit = not ‘N’<br />

a. Immersion length ‘U’ is defined by the 12-14th digits; 060 = 6.0 in.<br />

b. Look up ‘L’ length from the correct order chart for given ‘U’ length. This will be 4 inches for short sensors, or a whole number<br />

divisible by 3 for sensors longer than 4 inches (4, 6, 9, 12, 15, 18... inches);<br />

‘U’ 060 = 9 inches ‘L’<br />

c. Add extension length as defined by 9th <strong>and</strong> 10th digits; 30 = 3.0 in. to the ‘L’ length found in table.<br />

(9” + 3” = 12”, Length code 120)<br />

d. This will be the replacement sensor length ‘X’.<br />

Order sensor without connection head (5th digit N) or extension (8th digit N) 0078N23N00N120<br />