29.09.2014 Views

The Dangerous Music 2-Bus Manual

The Dangerous Music 2-Bus Manual

The Dangerous Music 2-Bus Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Dangerous</strong> <strong>Music</strong> 2-<strong>Bus</strong> <strong>Manual</strong><br />

Sometimes problems that sound like ground loops are caused by other situations. <strong>The</strong>se<br />

require trouble shooting beyond the scope of this section and a qualified technician may<br />

have to make a visit if help is needed.<br />

Expansion Inputs and Connector Pin-Outs<br />

<strong>The</strong> 2-<strong>Bus</strong> has an expansion input port that allows connecting other 2-<strong>Bus</strong>es and 2-<strong>Bus</strong><br />

LT’s, to increase the system size and capability. <strong>The</strong> 25-way ‘D’ connector on the rear<br />

panel labeled REM/EXP is used for this purpose. <strong>The</strong> REM/EXP port is wired according<br />

to the following chart. A pre wired expansion adapter for the 2-<strong>Bus</strong> is available when<br />

multiple units are bought or additional units are ordered for a facility already using one.<br />

Pin# function<br />

10 right +<br />

23 right –<br />

11 right shield<br />

24 left +<br />

12 left –<br />

25 left shield<br />

All the XLR connectors are pin 2 hot.<br />

Pin 1 shield<br />

Pin 2 + signal<br />

Pin 3 - signal<br />

So far, we have not seen Pin 1 hot (+), except after too many drinks…<br />

<strong>The</strong> AC Mains cable<br />

<strong>The</strong> mains cable uses a standard IEC connector. Please check the mains voltage<br />

selector (the little red window next to the IEC connector on the power supply) to<br />

make sure that it is correct for your location. <strong>The</strong> fuses for the voltage selection block<br />

are _ ampere, fast blow AGC type. PLEASE DON’T PUT A FUSE OF LARGER<br />

RATING IN THE BLOCK! Disconnect the mains cable before changing the voltage<br />

or replacing a fuse. If a fuse blows repeatedly, this is a sign from Mother Nature that<br />

something is wrong and the factory should be contacted for help at the link provided on<br />

the Specifications page.<br />

Please use pre-wired AC cables for this device unless a technically qualified person<br />

makes the connections to a mains plug. In this case, use only high quality mains plugs<br />

like Hubbel, Thomas & Betts, or similar. Remember, in America, Black is hot, White is<br />

neutral, and Green is ground. In Europe, Brown is hot, Blue is Neutral, and Green with a<br />

Yellow stripe is ground. It is critical to get this correct. Double check that it is!<br />