Solid State Relay<br />
................................... . . . . . . . . . . . .<br />
Reverser Relay<br />
SG/SV/SW Series - 3-Phase Without LED<br />
Cat. No. MOQ AC51<br />
2 2<br />
1 t(A S) Reversing Peak Operating Control MRP<br />
Rating Time Voltage Voltage Voltage Rs.<br />
SG969100* 3 6.6A 612 Adj.0.06s-4.0s 1200V AC 24-500V AC 12-30V DC<br />
SG969300* 3 8.5A 1500 Fixed 70ms 1600V AC 24-520V AC 12-30V DC<br />
SV969300* 3 8.5A 1500 Fixed 70ms 1600V AC 24-520V AC 12-30V DC<br />
SV969500* 1 16A 5000 Fixed 70ms 1600V AC 24-520V AC 12-30V DC<br />
SW960330* 3 4.5A 1500 Fixed 70ms 1600V AC 24-520V AC 12-30V DC<br />
SW961230* 3 8.5A 1500 Fixed 70ms 1600V AC 24-520V AC 12-30V DC<br />
*Non Sock Items. please allow 4-6 weeks delivery time<br />
Contact<br />
nearest<br />
sales<br />
office<br />
for<br />
Prices.<br />
MOQ - Minimum Order Qty.<br />
Common IP20<br />
Protective Cover for<br />
SC series SSR.<br />
Accessories for SSR<br />
Cat. No. MOQ Description MRP<br />
Rs.<br />
SC1K4600 20 IP20 Cover SC* 24<br />
SCHS6 DIN 20 Din Clip 105<br />
SCHS2200 5 Heat Sink 2.2K/W 660<br />
SCHS1100 5 Heat Sink 1.1 K/W 2140<br />
SCHS0900 5 Heat Sink 0.9 K/W 2535<br />
SCHS0300 5 Heat Sink 0.3K/W 3640<br />
*IP20 Protective Cover for complete SC range<br />
Refer to nearest branch office for heat sink selection<br />
Suggested Heat Sink Rth values<br />
(K/W) for load rating at diff.<br />
Ambient Temperature<br />
SSR 25°C 35°C 45°C 55°C<br />
Rating (A)<br />
12A 2.2 2.2 2.2 1.1<br />
25A 1.1 1.1 0.3 0.3<br />
40A 0.3 0.3 0.3 0.3<br />
50A 0.3 0.3 0.3 0.3<br />
75A 0.3 0.3 0.3 0.3<br />
95A 0.3 0.3 0.3 -<br />
125A 0.3 0.3 - -<br />
* For Heat Sink Selection of SO7 / SO8 / SO9 / SG4 / SG5<br />
ranges refer to nearest sales office<br />
Note: Apply heat sink compound between SSR base and external heat sink. In case of closely packed units<br />
the ambient temperature condition should be considered carefully. For proper protection, short-circuit<br />
protection device (SCPD) (having I 2 t rating lower than that of SSR I 2 t) must be used.<br />
Heat Sink - 65 mm<br />
Wide range of Heat<br />
sinks offers perfect<br />
coordination with all<br />
SSRs<br />
Contact nearest Branch Office for Price & technical details for<br />
following Special duty Solid State Relays<br />
SSR with AC Controls<br />
PCB Mounted SSR<br />
DC Relays<br />
Soft Starters<br />
SSR Integrated with heatsink-Softlife range<br />
SSR with spring terminals<br />
Celpac ® range - 22.5 & 45 mm pitch with system diagnostics<br />
SSR for transformer starting<br />
Three Phase Universal digital Proportional Controllers - SVTA - SWTA range<br />
24<br />
Effective from 29.09.2012